11-1227-002EXISTING FIXED GLASS CAT. II SAFETY 'V'&r,0m,,,.1. (4 LIFE SAFETY PLAN SCALE : 1/4"= 1' CLASS B INTERIOR FINISH. FLAMESPREAD 26 -75, SMOKE DEVELOPED 0 -450. CLASS C INTERIOR FINISH. FLAMESPREAD 76 -200, SMOKE DEVELOPE 0 -450. NOTE: CORRIDORS AND LOBBIES. LIFE SAFETY NOTES: ALL CONSTRUCTION TO BE IN COMPLIANCE WITH F.B.C. 418 DOOR CLOSURE: — Any Exit door designed to be normally closed shall be kept closed and shall comply with F.B.C. 705. 1.3.2.3. (418.4) SMOKE DETECTOR: — Provide (1) smoke detector per room min., (2) at ea. main space (max. coverage: 900 S.Q. F.T., ea., max spacing:30 F.T. Tie to outside horn. FIRE EXTINGUISHERS: — Fire Extinguishers to be installed ® 48" A.F.F. (Top ® 5' A.F.F. Max) w/ max travel distance to reach of 75' -0" FIRE SAFETY NOTES: 1. EXIT AND EMERGENCY LIGHTS SHALL HAVE A BATTERY BACK —UP 2. ALL EXIT DOORS SHALL HAVE A THUMBLATCH. 3. ADDRESS SHALL BE AT FRONT + REAR IN 6" NUMBERS. 4. ONE 2 A/0 BC EXT. AND 40 BC SHALL BE INSTALLED AT REAR. FLA. ACCESS REQ.: 1. MAX. DIFFERENCE IN FLOOR LEVEL SHALL BE 1/2" NOTE: THIS BUILDING DOES NOT HAVE FIRE SPRINKLER & NOT HAVE ALARM SYSTEMS AEWM -DARE COUNTY "r FM DEPARTMENT LEGEND FE FIRE EXTINGUISHER SD SMOKE DETECTOR EMERGENCY LIGHTS (W /BATTERY PACK) EXIT SIGN ILLUMINATED (W /BATTERY PACK) FIRE EXTINGUISHER: FIRE EXTINGUISHER: PROVIDE ONE CERTIFIED 2A -108C FIRE EXTINGUISHER FOR EACH 2,500 S.F. BY LARSEN'S CABINET: ARCHITECTURAL SERIES BY LARSEN'S MODEL #SS2409 -5R SEMI RECESSED SQUARE TRIM WITH 1 -1/2" PROJECTION. VERTICAL DUO DOOR: TO FIT WITHIN 4" PARTITION WALL. #8 POLISHED FINISH. PROVIDE WALL MOUNTED FIRE EXTINGUISHER AT 42" ABOVE FINISHED FLOOR TO LATCH. TRAVEL DISTANCE MUST NOT EXCEED 75 FEET INSTALATION AND MARKING MUST CORRESPOND WITH OSHA 1910.157, NFPA 10 AND HANDBOOKS MS 54 AND 56. WHEREVER A FIRE EXTINGUISHER IS INSTALLED IN A FIRE RATED PARTITION, THE FIRE RATING MUST NOT BE DISRUPTED. USE FLAME — SHIELD OPTION FOR FIRE —RATED AND DRAFT PARTITIONS ONLY. LOCATION TO BE DETERMINED IN THE FIELD. OCCUPANT LOAD USE AREA PER OCCUPANT (SQ. FT.) BUSSINE USE 1 PERSON /100 GROSS S.F. 1144.75 SQ. FT. /100 = 11 PERSON NUMBER OF OCCUPANTS REQUIRED EGRESS WIDTH (.2 / OCCUPANT) IN EXIT WIDTH PROVIDED (IN) SPA I TOTAL = 11 PERSONS LIFE SAFETY EXIT CALCULATION SMOKE COMPARTMENT AREA SQ. FT. OCCUPANT TYPE /LOAD FACTOR SO. FT. OCCUPANT) NUMBER OF OCCUPANTS REQUIRED EGRESS WIDTH (.2 / OCCUPANT) IN EXIT WIDTH PROVIDED (IN) SPA 1,144.78 100 11 2.2 72 TYPE OF CONSTRUCTION: V. ASSUMED (NO CHANGE) EXISTING BUILDING HEIGHT / AREA: NO CHANGE PROJECT AREA: 1144.78 SQ. FT. CHAPTER 3 -304 classification of occupancy BUSINESS AN OCCUPANCY USED FOR THE MINIMUM LOT WIDTH SPA LEGEND FE FIRE EXTINGUISHERS CAP. 40 LB CODE REQUIREMENTS FOR RENOV. PROJECTI APPLICABLE CODES: O FLORIDA BUILDING CODE 2007 O FLORIDA MECHANICAL CODE 2007 • FLORIDA PLUMBING CODE 2007 • INTERNATIONAL FIRE CODE 2003 O FLORIDA EXISTING BUILDING CODE 2007 O FLORIDA ENERGY CONSERVATION CODE 2007 ZONING ZONING DISTRICT — USE TYPE SR MINIMUM LOT WIDTH NO SPECIFIC REQUIREMENT MINIMUM LOT SIZE NO MIN. LOT SIZE REQUIRED SETBACKS NOT APPLICABLE BUILDING OCCUPANCY CLASSIFICATION BUSINESS GROUP B PERMITTED USES (SPA) MESSAGE THERAPIST TYPE OF CONSTRUCTION: V. ASSUMED (NO CHANGE) EXISTING BUILDING HEIGHT / AREA: NO CHANGE PROJECT AREA: 1144.78 SQ. FT. FIRE SUPPRESSION SYSTEM NO TABLE 503: ALLOWABLE HEIGHT /AREA 2 / 9,000 CLASSIFICATION OF WORK (F.B.C. /E— CHAPTER 4) ALTERATION — LEVEL 2 SEISMIC REQUIREMENTS SEISMIC USE GROUP NOT APPLICABLE SEISMIC DESIGN CATEGORY NOT APPLICABLE CORRIDOR WIDTH: CORRIDOR ACCESS (MIN) 44 INCHES ALLOWABLE DEAD END CORRIDOR: 20 FEET TRAVEL DISTANCE: MAX. ALLOW. TRAVEL DISTANCE 150 FEET (NON— SPRINKLERED) COMMON PATH OF TRAVEL 100 FEET OCCUPANT LOAD BY TABLE 1004.1.1 (F.B.C.) 11 PERSONS ACTUAL OCCUPANT LOAD WITHIN WORK AREA NOT APPLICABLE (MIN.) NO. OF EXITS REQUIRED WITHIN WORK AREA 2 REQUIRED (< 500 OCCUPANTS) (MINIMUM) DOOR AND CORRIDOR WIDTH REQUIRED WITHIN WORK AREA (BUSINESS) 11 OCCUPANTS X 0.2 2.2" MINIMUM DOOR WIDTH 32" CORRIDOR FIRE — RESISTANCE RATING EXIT: WITH OCCUPANT LOAD GREATER THAN 30 1 PARKING REQUIRED: PARKING provided 1144.78 SO. FT./ 200 - 6 PARKING COMMUNE PARKING !1 l:l el LE AVA INAWN, 150 LOA THESE DRAWING do SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF JORGE ALBA WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO JORGE ALBA F w w x V) Z Q J W LL U) W ILL J a 111 1 i , JORGE ALBA PROFESSIONAL ENGINEER P.E. 63967 409 PHIPPEN ROAD DANIA BEACH, FL. 33004 (954) 483 5031 DATE 11/26/11 DRAWN BY. M. GUILLEN CHECKED BY. JA SCALE: AS SHOW F -1 I SHEET NUMBER: 4 0 T b W N_ J Q 0 0 rn V N UM) W M J W Cn cn m � O [L— U J (� Z W W W 0 Q ° W Z LU CL O n" (n 0 0 0 Z O U) Z 0 F W � �Z W 0 Z a_ 0 O F w w x V) Z Q J W LL U) W ILL J a 111 1 i , JORGE ALBA PROFESSIONAL ENGINEER P.E. 63967 409 PHIPPEN ROAD DANIA BEACH, FL. 33004 (954) 483 5031 DATE 11/26/11 DRAWN BY. M. GUILLEN CHECKED BY. JA SCALE: AS SHOW F -1 I SHEET NUMBER: 4 0 T b