11-1227-002EXISTING
FIXED GLASS
CAT. II SAFETY
'V'&r,0m,,,.1.
(4
LIFE SAFETY PLAN
SCALE : 1/4"= 1'
CLASS B INTERIOR FINISH.
FLAMESPREAD 26 -75, SMOKE
DEVELOPED 0 -450.
CLASS C INTERIOR FINISH.
FLAMESPREAD 76 -200, SMOKE
DEVELOPE 0 -450.
NOTE:
CORRIDORS AND LOBBIES.
LIFE SAFETY NOTES:
ALL CONSTRUCTION TO BE IN COMPLIANCE WITH F.B.C. 418
DOOR CLOSURE:
— Any Exit door designed to be normally closed shall be kept
closed and shall comply with F.B.C. 705. 1.3.2.3. (418.4)
SMOKE DETECTOR:
— Provide (1) smoke detector per room min., (2) at ea. main
space (max. coverage: 900 S.Q. F.T., ea., max spacing:30 F.T.
Tie to outside horn.
FIRE EXTINGUISHERS:
— Fire Extinguishers to be installed ® 48" A.F.F. (Top ® 5'
A.F.F. Max) w/ max travel distance to reach of 75' -0"
FIRE SAFETY NOTES:
1. EXIT AND EMERGENCY LIGHTS SHALL HAVE
A BATTERY BACK —UP
2. ALL EXIT DOORS SHALL HAVE A THUMBLATCH.
3. ADDRESS SHALL BE AT FRONT + REAR
IN 6" NUMBERS.
4. ONE 2 A/0 BC EXT. AND 40 BC SHALL BE
INSTALLED AT REAR.
FLA. ACCESS REQ.:
1. MAX. DIFFERENCE IN FLOOR LEVEL SHALL BE 1/2"
NOTE:
THIS BUILDING DOES NOT HAVE FIRE
SPRINKLER & NOT HAVE ALARM SYSTEMS
AEWM -DARE COUNTY
"r FM DEPARTMENT
LEGEND
FE FIRE EXTINGUISHER
SD SMOKE DETECTOR
EMERGENCY LIGHTS (W /BATTERY PACK)
EXIT SIGN ILLUMINATED (W /BATTERY PACK)
FIRE EXTINGUISHER:
FIRE EXTINGUISHER: PROVIDE ONE CERTIFIED 2A -108C FIRE
EXTINGUISHER FOR EACH 2,500 S.F. BY LARSEN'S
CABINET: ARCHITECTURAL SERIES BY LARSEN'S MODEL #SS2409 -5R
SEMI RECESSED SQUARE TRIM WITH 1 -1/2" PROJECTION.
VERTICAL DUO DOOR: TO FIT WITHIN 4" PARTITION WALL. #8 POLISHED
FINISH. PROVIDE WALL MOUNTED FIRE EXTINGUISHER AT 42" ABOVE
FINISHED FLOOR TO LATCH. TRAVEL DISTANCE MUST NOT EXCEED
75 FEET INSTALATION AND MARKING MUST CORRESPOND WITH OSHA
1910.157, NFPA 10 AND HANDBOOKS MS 54 AND 56. WHEREVER A
FIRE EXTINGUISHER IS INSTALLED IN A FIRE RATED PARTITION, THE
FIRE RATING MUST NOT BE DISRUPTED. USE FLAME — SHIELD OPTION
FOR FIRE —RATED AND DRAFT PARTITIONS ONLY. LOCATION TO BE
DETERMINED IN THE FIELD.
OCCUPANT LOAD
USE AREA PER OCCUPANT (SQ. FT.)
BUSSINE USE
1 PERSON /100 GROSS S.F. 1144.75 SQ. FT. /100 = 11 PERSON
NUMBER OF
OCCUPANTS
REQUIRED EGRESS WIDTH
(.2 / OCCUPANT) IN
EXIT WIDTH
PROVIDED (IN)
SPA
I TOTAL = 11 PERSONS
LIFE SAFETY EXIT CALCULATION
SMOKE
COMPARTMENT
AREA
SQ. FT.
OCCUPANT TYPE /LOAD FACTOR
SO. FT. OCCUPANT)
NUMBER OF
OCCUPANTS
REQUIRED EGRESS WIDTH
(.2 / OCCUPANT) IN
EXIT WIDTH
PROVIDED (IN)
SPA
1,144.78
100
11
2.2
72
TYPE OF CONSTRUCTION:
V. ASSUMED (NO CHANGE)
EXISTING BUILDING HEIGHT / AREA:
NO CHANGE
PROJECT AREA:
1144.78 SQ. FT.
CHAPTER 3 -304
classification of occupancy
BUSINESS
AN OCCUPANCY USED FOR THE
MINIMUM LOT WIDTH
SPA
LEGEND
FE FIRE EXTINGUISHERS CAP. 40 LB
CODE REQUIREMENTS FOR RENOV. PROJECTI
APPLICABLE CODES:
O FLORIDA BUILDING CODE 2007
O FLORIDA MECHANICAL CODE 2007
• FLORIDA PLUMBING CODE 2007
• INTERNATIONAL FIRE CODE 2003
O FLORIDA EXISTING BUILDING CODE 2007
O FLORIDA ENERGY CONSERVATION CODE 2007
ZONING
ZONING DISTRICT — USE TYPE SR
MINIMUM LOT WIDTH
NO SPECIFIC REQUIREMENT
MINIMUM LOT SIZE
NO MIN. LOT SIZE REQUIRED
SETBACKS
NOT APPLICABLE
BUILDING OCCUPANCY CLASSIFICATION
BUSINESS GROUP B
PERMITTED USES
(SPA) MESSAGE THERAPIST
TYPE OF CONSTRUCTION:
V. ASSUMED (NO CHANGE)
EXISTING BUILDING HEIGHT / AREA:
NO CHANGE
PROJECT AREA:
1144.78 SQ. FT.
FIRE SUPPRESSION SYSTEM
NO
TABLE 503: ALLOWABLE HEIGHT /AREA
2 / 9,000
CLASSIFICATION OF WORK (F.B.C. /E— CHAPTER 4)
ALTERATION — LEVEL 2
SEISMIC REQUIREMENTS SEISMIC USE GROUP
NOT APPLICABLE
SEISMIC DESIGN CATEGORY
NOT APPLICABLE
CORRIDOR WIDTH: CORRIDOR ACCESS (MIN)
44 INCHES
ALLOWABLE DEAD END CORRIDOR:
20 FEET
TRAVEL DISTANCE: MAX. ALLOW. TRAVEL DISTANCE
150 FEET (NON— SPRINKLERED)
COMMON PATH OF TRAVEL
100 FEET
OCCUPANT LOAD BY TABLE 1004.1.1 (F.B.C.)
11 PERSONS
ACTUAL OCCUPANT LOAD WITHIN WORK AREA
NOT APPLICABLE
(MIN.) NO. OF EXITS REQUIRED WITHIN WORK AREA
2 REQUIRED (< 500 OCCUPANTS)
(MINIMUM) DOOR AND CORRIDOR WIDTH REQUIRED
WITHIN WORK AREA
(BUSINESS) 11 OCCUPANTS X 0.2 2.2"
MINIMUM DOOR WIDTH 32"
CORRIDOR FIRE — RESISTANCE RATING EXIT: WITH
OCCUPANT LOAD GREATER THAN 30
1
PARKING REQUIRED:
PARKING provided
1144.78 SO. FT./ 200 - 6 PARKING
COMMUNE PARKING
!1
l:l
el LE AVA INAWN, 150 LOA
THESE DRAWING do SPECIFICATIONS
ARE INSTRUMENTS OF SERVICE AND
SHALL REMAIN THE PROPERTY OF
JORGE ALBA WHETHER THE PROJECT
FOR WHICH THEY WERE PREPARED
IS EXECUTED OR NOT, THEY ARE NOT
TO BE USED IN ANY MANNER ON OTHER
PROJECTS OR EXTENSIONS TO THIS
PROJECT EXCEPT BY AGREEMENT IN
WRITING AND WITH THE APPROPRIATE
COMPENSATION TO JORGE ALBA
F
w
w
x
V)
Z
Q
J
W
LL
U)
W
ILL
J
a 111 1 i ,
JORGE ALBA
PROFESSIONAL ENGINEER
P.E. 63967
409 PHIPPEN ROAD
DANIA BEACH, FL. 33004
(954) 483 5031
DATE 11/26/11
DRAWN BY. M. GUILLEN
CHECKED BY. JA
SCALE: AS SHOW
F -1
I SHEET NUMBER: 4 0 T b
W
N_
J
Q
0
0
rn
V
N
UM)
W
M
J
W
Cn
cn
m
�
O
[L—
U
J
(�
Z
W W
W
0
Q
°
W
Z
LU
CL
O
n"
(n
0
0
0
Z
O
U)
Z
0
F
W
�
�Z
W
0
Z
a_
0
O
F
w
w
x
V)
Z
Q
J
W
LL
U)
W
ILL
J
a 111 1 i ,
JORGE ALBA
PROFESSIONAL ENGINEER
P.E. 63967
409 PHIPPEN ROAD
DANIA BEACH, FL. 33004
(954) 483 5031
DATE 11/26/11
DRAWN BY. M. GUILLEN
CHECKED BY. JA
SCALE: AS SHOW
F -1
I SHEET NUMBER: 4 0 T b