09-1027-023HVAC NOTES 1. GENERAL A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code and with all applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the HVAC work. C. ARRANGE AND PAY for all permits licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. Compressors shall be guranteed for a period of five years. E. As built drawings shall be submitted to owner at the completion of project. 2. SHOP DRAWINGS: Contractors shall submit for approval, within 30 days after signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: fans, air conditioning units, air outlets. No work shall proceed without approval of these submittals. 3. DESIGN PARAMETERS: A. Outdoor design temperature (Summer): 917 DB and 797 WB B. Outdoor design temperature (Winter): 457 C. Indoor design temperature (Summer): 787 DB D. Indoor design temperature (Winter): 72•F DB 4. ALL THERMOSTATS SHALL have heating mode maximum setting of 75 F, and cooling mode minimum setting of 70 F. The thermostat shall be arranged to prevent the simultaneous operation of heating and cooling. 5. ELECTRICAL CONTROLS AND POWER WIRING: Under electrical contract. 6. EQUIPMENT SPECIFIED BY manufacturer's number shall include all accessories, controls, etc., listed in the catalog as standard with the equipment. Optional or additional accessories shall be furnished as specified. 7. MATERIALS: A. REFRIGERANT PIPING: Shall be type L soft drawn, copper tubing, dehydrated for refrigerant use. Sized as shown on drawings or as per air conditioning equipment manufacturer's recommendations. B. INSULATION: Refrigerant suction piping shall be insulated with 1/2" thick foamed plastic insulation, fire retardant type. Insulation shall be installed in piping before assembly. No split insulation will be acceptable. Seal joints with manufacturer's approved adhesive and grey tape. C. DUCTWORK: a. All supply air ductwork shall be fiberglass ductboard, fabricated and installed as per latest edition of SMACNA "Fibrous Glass Duct Manual ". 1 -1/2" thick R -6.0 in uncond. space. 1" thick R -4.2 in cond. space. b. All exhaust ductwork shall be galvanized sheet metal duct not lighter than 26 gage. C. All duct dimensions are clear inside dimensions. d. Flexible insulated ductwork with 1 1/2" thick fiberglass insulation with FRK vapor barrier, class I air duct, U.L. R -6.0 MIN. e. Dryer ductwork: 26 ga. min. golvinized steel, having a smooth interior surface with joints running in the direction of airflow and without sheet metal screws or other fastners in the air stream. Maximum length shall not exceed 25 feet. wall caps shall be provided with backdraft damper. 8. Provide metal round fittings with scoop at all flexible duct connection to supply duct. 9. TEST AND BALANCE: Contractor shall test and balance all ventilation and air conditioning systems. Submit four copies of Test and Balance Report to owner for approval. 10. CONTROLS: Air conditioning units shall be started and stopped thru individual thermostat. Individual thermostats shall start /stop supply fans and activate cooling /heating systems as selected. 11. Mechanical plans in general, are diagrammatic in nature, and are to be read in conjuction with arch. Plumbing, electrical and structural plans and shall be considered as one set of documents. Duct and piping offsets, bends and transitions will be required to provide and install a complete functional system and shall be provided by the contractor at no additional cost to the owner. 12. Contractor shall verify job conditions prior to ordering, fabrication or installation of materials or equipment. Notify architect /engineer of any conflicts before fabrication. HANGER WIRE 12 GAUGE (MIN.) SUSPENDED CEILING (SEE ARCH. DRAWING SLAB SCREWS FASTENERS. DUCT SHEET METAL CHANNEL NOTE: DUCT HANGER DETAIL N.T.S. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR - X FIRE DAMPER(S) - X SMOKE DAMPER(S) - X FIRE RATED ENCLOSURE - X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - X FIRE STOPPING - X SMOKE CONTROL - X SPLIT AC UNIT SCHEDULE UNIT DESIGNATION FCU -1 AREA SERVED SEE DWG LOCATION A/C CLOSET OPERATING WEIGHT, LBS 110 DESIGN MANUFACTURER TRANE XL15i MODEL NUMBER 4TEE3F37B1000 SEER MIN. 15.25 REFRIGERANT TYPE R -410 Z TOTAL AIR, CFM 1010 # CFM VENT AIR, CFM SUPPLY AIR N EXTERNAL STATIC PRESSURE, IN OF WATER 0.50 AIR FAN MOTOR HP. (NON- OVERLOAD) 1/2 TITUS 250 -AA DIMENSIONS 21 "X22 "X35" __J FACE VELOCITY - FPM TITUS 4FL O U DESIGN AIR ACROSS COIL, CFM. 1010 EXHAUST FAN GRAN TOTAL CAPACITY, BTU /HR 29,000 SERVICE SWITCH TOTAL SENSIBLE CAPACITY, BTU /HR 20,950 NO ENTERING AIR TEMP., DB WB 80/67 CONSTRUCTION TYPE & THICKNESS 1 CLEANABLE J QUANTITY AND SIZE BIRDSCREEN NO FACE VELOCITY FPM. MAX. NO THERMOSTAT CONTROL NO FACTORY FABRICATED CURB MODEL NO. NO HEAT COIL TYPE ELECTRIC W ELECTRICAL SERVICE AVAILABLE 240 -1 -60 UJAUXILIARY ELECTRIC HEAT, KW 5.0 = STAGES & KW PER STAGE 1 5.0 F- MIN. CIRC. AMP 32.3 W MAX. CIRC. PROT. 45 O UNIT DESIGNATION CU -1 CL TYPE OF FAN PROPELLER 0 NO. OF FANS AND HP 1 .33 AMBIENT AIR TEMP. -F DB 95 =Z CONDENSING TEMP. 'F DB U NO. OF COMPRESSORS TYPE 1/SCROLL ? COMPRESSORS F.L.A. L.R.A. EACH 11.1/63 z CAPACITY REDUCTION. 0 -100% o MIN. CIRC. AMP 17 Z MAX. CIRC. PROT. 25 ELECTRICAL SERVICE AVAILABLE 240/1/60 w OPERATING WEIGHT, LBS 223 o DESIGN MANUFACTURER TRANE XL15i MODEL NUMBER 4TTX503OAl000A Q REFRIGERANT PIPE SIZE, SUCTION (IN. OD) 3/4" REFRIGERANT PIPE SIZE, LIQUID (IN. OD ) 3/8" NOTES: 1. ALL THERMOSTATS SHALL BE PROGRAMMABLE. 2. ALL FAN COIL UNITS SHALL BE PROVIDED WITH FACTORY INSTALLED CIRCUIT BREAKER. HVAC KEY NOTES: 1. 4" ROOF JACK WITH BIRDSCREEN. 2. THERMOSTAT 3. FULL LOUVERED DOOR. 4. FULL SIZE SA PLENUMN. 5. 3/4" CD TRAP AND 2" CD LINE U/G TO FRENCH CONDENSATE DRY WELL. 6. TIE EXISTING 3/4" CD LINE INTO NEW 1 -1/4" CD LINE U /G. 7. EXISTING 4" DRYER EXH. CAP TO BE REMOVED. 8. NEW REF LINES. U/G VERIFY DIMENSIONS ON SITE WITH EXISTING CU AND FCU. 9. NEW REF LINES. U /G. 10. NEW 4"0 DRYER EXH. DUCT UP TO ROOF CAP WITH BACK DRAFT DAMPER. FIBROUS GLASS DUCT. 22 Ga. SHEET METAL POCKET LOCK 1 "X1 "X1 " GLASS FABRIC AND AND MASTIC (GFM) CLOSURE OVER POCKECT LOCK AND DUCT BOARD. FAN COIL UNIT SURFACE. #10 X 1 -1/4" SHEET METAL SCREWS 12" MAX. O.C. MIN. 2 PER SIDE. FAN COIL UNIT CONNECTION DETAIL N.T.S. AIR DISTRIBUTION SCHEDULE SYMBOL USE TYPE ACCESSORIES MFG. & MODEL NO. 17 SUPPLY WALL ELBOW W/ TURNING VALVES REF. S &R O TOTAL AIR, CFM CEILING EXHAUST FAN O.B.D. TITUS 272 FS OT AIR REGISTER X: AIR DEVICE TYPE # X O # CFM SUPPLY SUPPLY AIR SA SUPPLY AIR LI AIR DIFFUSER O.B.D. TITUS 250 -AA © RETURN CEILING /WALL O.B.D. TITUS 4FL FCU AIR GRILLE EXHAUST FAN UC�_ NOTE: 1. ALL AIR DISTRIBUTION DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION. 2. COORDINATE COLOR FINISH WITH ARCHITECT, WHITE BAKED ENAMEL STANDARD. 3. ARROWS INDICATE DIRECTION OF AIR DISTRIBUTION. CEILIr DRAIN NE ❑PR ANGLE SUPP❑ DIAL ❑I '--24" FRENCH CONDENSATE DRY WELL UPPLY AIR DUCT IN ATTIC EE C❑NNECTI ❑N DETAIL ❑MM ❑N WALL FAN SECTI ❑N FRIGERANT PIPES -ROM COND. UNIT ❑IL SECTI ❑N OAT SWITH. SWITH SHALL STOP FAN JIT IF INDICATED. -ILTER FAN COIL UNIT MOUNTING DETAIL N.T.S. HVAC SYMBOL LEGEND SYMBOL DESCRIPTION ® SUPPLY DUCT TOILET RETURN /EXHAUST DUCT 17 FLEXIBLE DUCT CEILING ELBOW W/ TURNING VALVES REF. S &R REFRIGERANT SUCTION & LIQUID LINES TOTAL AIR, CFM CEILING EXHAUST FAN DRIVE TYPE EXHAUST REGISTER OT COOLING THERMOSTAT A X B B. X: AIR DEVICE TYPE # X O # CFM TOTAL STATIC PRESSURE, IN OF WATER AXB: NECK SIZE SA SUPPLY AIR RA RETURN AIR EA EXHAUST AIR CU CONDENSING UNIT AFF ABOVE FINISH FLOOR CFM CUBIC FEET PER MINUTE FCU FAN COIL UNIT EF EXHAUST FAN UC�_ DOOR UNDERCUT, 1" MIN. CONDENSING UNIT 6" MIN. FASTEN C.U. TO CONCRETE PAD USING (4) 1/4" CONCRETE SCREWS WITH 1.5" EMBEDMENT MINIMUM AS PER MFG. CERTIFIED DATA. PROVIDE (4) 1/2" ISOMODE PADS AT EACH SCREW CONCRETE BASE W/ 6X6- 10 /10WWF 6 "MIN. SEAL ENTRANCE OF REFRIGERANT LINES INTO P.V.C. PIPE W/ IMPERMEABLE, RESILIENT MATERIAL NOTE: CONCRETE CREWS SHALL BE RATED FOR 500 LBS. MIN. PULL -OUT CAPACITY. VENTILATION FAN SCHEDULE UNIT DESIGNATION EF -1 AREA SERVED TOILET OPERATING WEIGHT, LBS 17 LOCATION CEILING FAN TYPE CLG. BLOWER Z TOTAL AIR, CFM 80 DRIVE TYPE DIRECT FAN WHEEL TYPE CENTRIFUGAL FAN TIP SPEED, FPM MAX. - -- FAN SPEED, RPM - -- TOTAL STATIC PRESSURE, IN OF WATER 0.1 FAN MOTOR HP. (NON- OVERLOAD) 0.2 AMPS FAN MOTOR STARTER TYPE WALL SWITCH STARTER FURNISHED BY MC ELECTRICAL SERVICE AVAILABLE 120 -1 -60 MASONARY OPENING REQUIRED - -- o ~ ZONE RAITING 0.3 DESIGN MANUFACTURER PANASONIC MODEL NUMBER FV -08VQ3 w SERVICE SWITCH YES SMOKE DETECTOR ( U.L. APPROVED) NO FIRE DAMPER - -- CONSTRUCTION ALUM /PLASTIC 0 0 V) w U a MULTIBLADE BACKDRAFT DAMPER YES BIRDSCREEN NO SOLID STATE SPEED CONTROL NO THERMOSTAT CONTROL NO FACTORY FABRICATED CURB MODEL NO. NO FACTORY ENCLOSURE W /MESH SCREEN NO POWER & CONTROL CONNECTIONS >� 6" MIN. 4" MIN. CONDENSING UNIT MOUNTING DETAIL N.T.S. AIR DUCT (SEE PLAN VIEW) BRANCH TAKE -OFF METAL ROUND FITTING <:_�n AIR FLOW SEAL JOINT W/ DUCT SEALER AND 6' MAX. TAPE AIR nFLOW V LIQUID LINE W/O INSULATION INSULATED FLEX. DUCT SEAL JOINT WITH DUCT SEALER AND TAPE DIFFUSER W/ OPPOSED BLADE DAMPER ADAPTOR ROUND TO SQUARE IF REQUIRED NSULATED DIFFUSER TOPS FLEXIBLE DUCT CONNECTION DETAIL N.T.S. JOB NO. 09 -090 PVC SCH.40 PIPE SIZED 2" LARGER THAN THE PIPE AND INSULATION ENCASED. (4 "0 1A MIN.) - SUCTION LINE W/ 1/2" ARMAFLEX INSULATION & VAPOR BARRIER 0 0 LU - U) = _ co -� M rn o N EE Q o ~ � o Q CD rm o�-a U) d' � x a O rn o ti v° 0 x E C o 5o a o 2� M � W tp a U cc")) a, °- ¢ IL Q Q .. �(D O04ZZ LJ Z 2 ¢` > O = v O � 1.;; F- L0 W O CL 0 0 0 0 ��,qt4 ►a17,; ,n �, in ON Cn G, •• C7 F l a Co L, � w o � o 0 0 U Z 9 W w Cl) M x Cl) p. J W � Q w ti 06 r- LO 0 0 0 0 w wT M' F_ ` � UJ aN ^o 0 0 ; 0 o W Z. LL 0 H i ¢ U� r` 00 LO 0 0 0 0 DATE: 10/19/09 DRAWN BY: A.PENA / T.V. l E.C. CHECKED BY: R.P.J. REVISIONS: PROJECT NUMBER: 2009-08 SHEET: M -101 OF 0 © COPYRIGHT 2009 0 O. .