09-1027-004\\
\\
\\
\ \
1
REMOVED
EXISTING / DEMOLITION FLOOR PLAN
1/411 = 1' -011
N
i \A\
`i of S N� 'DVF t
sovlo"`!
GeV'
cl� OLO T.
ISG
:4
DEMOLITION NOTES:
1. COMPLY WITH ALL PERTINENT REGULATIONS, GOVERNMENT AGENCIES AND
FEDERAL,STATE AND LOCAL ORDINANCES.
2. GENERAL CONTRACTOR SHALL EXAMINE THE SITE AND COME FAMILIAR WITH
CONDITIONS AFFECTING THE WORK BEFORE SUBMITTING THE BIDS.
3. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL RE-
QUIRED PERMITS AND PAYING FOR ALL PERMITS FEES.
4. BUILDING TO BE DEMOLISHED MUST BE VACATED PRIOR TO START OF WORK.
5. USE OF EXPLOSIVES WILL NOT BE PERMITTED.
6. OWNER SHALL SUBMIT AN ASBESTOS EVALUATION FINDINGS REPORT BY QUALIFIED
TESTING LABORATORY.
7. BURNING OF REMOVED MATERIALS FROM DEMOLISHED STRUCTURES WILL
NOT BE PERMITTED ON SITE.
8. ENSURE SAFE PASSAGE OF PERSONS AROUND AREA OF DEMOLITION.
CONDUCT OPERATIONS TO PREVENT INJURY TO PERSONS AND DAMAGE TO
ADJACENT STRUCTURES.
9. CONDUCT DEMOLITION OPERATIONS AND REMOVAL OF DEBRIS TO ENSURE MINIMUM
INTERFERENCE WITH ROADS, STREET WALKS, OTHER ADJACENT OCCUPIED SPACE OR
USED FACILITIES.
10. ITEMS OF SALVAGEABLE VALUE TO OWNER MAY BE REMOVED FROM STRUCTURE
AS WORK PROGRESSES SALVAGED ITEMS MUST BE STORED AN PROTECTED
AS THEY ARE REMOVED. COORDINATED WITH OWNER.
11. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN, KEEP IN SERVICE, PROTECT
AGAINST DAMAGE DURING DEMOLITION OPERATION.
12. DISCONNECT AND SEAL UTILITIES SERVING STRUCTURES TO BE DEMOLISHED,
ADJACENT FACILITIES TO REMAIN.
13. PROVIDE INTERIOR, EXTERIOR SHORING, BRACING, OR SUPPORT TO PREVENT
MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURES TO BE DEMOLISHED
ADJACENT FACILITIES TO REMAIN.
14. COORDINATE WITH STRUCTURAL ENGINEER PRIOR TO COMMENCEMENT WORK REMOVAL
OF ANY LOAD BEARING WALL OR STRUCTURAL ELEMENT.
15. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL STRUCTURAL DEMOLITION.
16. PROVIDE INTERIOR, EXTERIOR SHORING, BRACING, OR SUPPORT TO PREVENT
MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURES TO REMAIN.
NOTES
THE DEMOLITION PLAN IS SHOWN IN ITS ENTIRITY TO INDICATE THE EXTEND OF
DEMOLITION. THE CONTRACTOR SHALL COORDINATE WITH THE STUCTURAL
ENGINEER AND SEQUENCE THE DEMOLITION TO MANTAIN STABILITY OF THE
EXISTING STRUCTURE AND SAFETY.
NO MASONRY WALL OR PORTION THEREOF AND / OR BEARING PARTITION
WALL SHALL BE REMOVED BY THE CONTRACTOR PRIOR TO ISSUANCE OF
CITY, APPROVED REMEDIAL DETAILS.
SYMBOLS LEGEND
8" OR 12" EXISTING C.M.U. WALLS TO REMAIN
8" OR 12" EXISTING C.M.U. WALLS TO BE REMOVED
EXISTING INTERIOR WALLS TO REMAIN
EXISTING INTERIOR WALLS, DOORS & FIXTURES TO BE REMOVED
1
o
O
U
c
rn
M N
y
-
p
—
a
o 0_P
H ~
LL o.
I-
W
u- -0 0
o H o
O m r_
Oo
�
E
c
O .-
M
a
a
Q 2
o
Go ^,
o.
u
Lo
Z
a
C/)
o
;
Lo
0
n.
0
0
0
0
IL
sr
v
Z'o
Lil
O
O
O
O
U
LOU
Z
W
M
w ,
Q
~ r
W
U
E-
0 0
0
�ti
V
co
00
Lo
o
°
0
0
w
w
v
f- "'
w
D
F- ¢
Lu
N
v
0O
o
j
o
w
o
D
> LL
0
0
J
?� —
0
co
to
O
o
O
O
DATE:
10/20/2009
DRAWN BY:
ABA
CHECKED BY:
JLGP
REVISIONS:
PROJECT NUMBER:
2009 -08
SHEET: D -101
OF
0 Q COPYRIGHT 2009 °