09-602-010f 4 t r I FIRE PROTECTION GENERAL NOTES 1. FIRE PROTECTION SYSTEM TO COMPLY WITH NFPA 13, AND ALL APPLICABLE.STATE ` AND LOCAL CODES. 2. ADHERE TO AND OBTAIN ALL PERMITS, LICENSES AND GOVERNMENT REQUIREMENTS. F 3. FINAL INSPECTION AND APPROVAL BY LOCAL FIRE DEPARTMENT, AND ARCHITECT /ENGINEER. 5. CUTTING OF STRUCTURAL AND /OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE ARCHITECT. 6. PIPE ROUTING SHOWN SHALL BE USED AND ANY ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPE=R INSTALLATION, COORDINATION WITH OTHER TRADES, AND /OR TO MAINTAIN PROPER CLEARANCES SHALL BE PROVIDED. VERIFY EXISTING STRUCTURAL, MECHANICAL, ELECTRICAL INSTALLATIONS AND AVOID ANY /ALL OBSTRUCTIONS OR INTERFERENCES WITH FIRE PROTECTION PIPE ROUTING. 7. FIRE STOP ALL PENETRATIONS OF SMOKE /FIRE WALLS, CEILINGS, FLOORS, ROOFS, ETC. FLASH AND COUNTERFLASH ROOF PENETRATIONS. (SEE FIRE RATED PIPE PENETRATION DETAIL). 8. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON - ACCESSIBLE CEILINGS AND CHASES. 9. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL EXISTING /NEW DIFFUSERS, SPEAKERS, LIGHTING FIXTURES AND CEILING SYSTEMS. 10. METHODS OF HANGING PIPES, HEADERS AND BRANCHES SHALL BE IN ACCORDANCE WITH N.F.P.A. 13. 11. AUTOMATIC SPRINKLER TEMPERATURE RATINGS OF FUSIBLE ELEMENTS TO BE IN ACCORDANCE WITH N.F.P.A. 13. 12. ALL VALVES FOR FIRE SERVICE SHALL BE LISTED BY THE UNDERWRITER'S LABORATORIES, INC. AND THE FACTORY MUTUAL LABORATORIES. VALVES SHALL BE FACTORY MARKED "UL" AND "FM ", 175 WORKING PRESSURE. 13. ALL VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY SUPERVISED. TYPE AND EXACT LOCATION OF FLOW, PRESSURE AND SUPERVISORY SWITCHES SHALL FACTORY MARKED "UL" AND "FM ", 175 WORKING PRESSURE. 14. ALL POWER WIRING SHALL BE ACCOMPLISHED UNDER THE ELECTRICAL DIVISION. ALL CONTROL AND INTERLOCK WIRING SHALL BE ACCOMPLISHED UNDER THIS SECTION OF THE SPECIFICATIONS IN ACCORDANCE WITH THE REQUIREMENTS IN THE ELECTRICAL DIVISION. COORDINATE ALL ELECTRICAL ITEMS WITH ELECTRICAL CONTRACTOR AND INSURE PROPER COORDINATION. 15. SPRINKLERS SHALL COVER THE ENTIRE AREA OF THE ROOM INCLUDING ALCOVES. SPRAY SHALL NOT BE BLOCKED BY WALLS OR PARTITIONS. 16. ALL SPRINKLER HEADS MOUNTED IN CEILING SHALL BE LOCATED A MINIMUM OF 4" AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER VERTICAL INTERSECTING SURFACE. 17. PIPE SHALL BE REAMED AND CLEANED BEFORE ASSEMBLY. 18, MAINTAIN A MINIMUM OF It INCHES FROM THE BOTTOM OF THE SPRINKLER DEFLECTOR TO THE TOP OF STORAGE/FILE STORAGE. 19. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK 4 FEET OR WIDER. 20, FIRE SPRINKLER SYSTEM TO BE MONITORED BY FIRE ALARM SYSTEM BY OTHERS. 21. 0 INDICATES HYDRAULIC REFERENCE NODES (1) - - - - o- -- ••r• ... . e �...• r•• • a r • e � �r•rr • r• • • e v r r ••r c•• • • e •••• • • • I r •• r • I • r r • • • • • • • • • • I • r r • • r• • • •• • r Ilrr re •• r •• I I I I I I I i I i I I I I 1 I I I i I E D.1 D C ICI B A I 1 No. I Date 1 2/9/2 2 4/14, 1/4" TAP 2 1/2" TAP WATER FLOW SWITCH PRESSURE GAUGE -I TO SPRINKLER Fire Sprinkler Piping Plan SCALE: 1/8"44" 1 " DRAIN FOR 1 CONTROL VALVE'` ,« DRAIN /TEST ASSEMBLY 11/ DRAIN FOR 2% " CONTROL VALVE a 1/2" RISER PIPE RISER CLAMP al -LINE MODEL 13373CTC OR EQUAL) MIN L' THICK MEDIUM DENSITY NEOPRENE 3XEEL P STEEL PLATES CONCR. FLOOR (CLUE TOGETHER WITH NEOPRENE PAD TO FORM ONE UNIT. USE CONTACT • • CEMENT). ELEVATI ❑N SEE FIRESTOP DETAIL 1 1/4" DRAIN r 3. LAB PLAN VIEW 3' NOTES PROVIDE RISER CLAMP IENI STRAPS AT EVERY OTHER FLOOR FIRE S P R 1 N K L E R CONTROL VALVE ASSEMBLY DETAIL MAXIMUM DISTANCE BETWEEN HANGERS HAN{ER WAR. {ROP -IN ANCHOR wa 312* R•{ OWFUNG SIZE (in.) 3/4' 3//1' ALL T�HFAO RN 1 -1/4" 1 -1/2" RN{ (T4RI bR 2 -1/2" 3" (ALGMN. ORRAAN�E{) 4" 5" G" /" STEEL PIPE EXCEPT N/A 12 -0 12 -0 TYPICAL HANGER DETAIL 15 -0 15 -0 N.T,9. 15 -0 PRE SIZE FOP SIZE TYPE OF YIN. 'e MAX. 'C' FASftit {IN, aim, 3/4' J / {• 1 -3/9' X 1.17/32* DROP-IN ANCHOR 1' i/c 1 -3/4' 1_1/4, 13/16' 1 -7/11' 12 -0 12 -0 12 -0 2' 1 -3/14 2 -3 /9' 2 -1/2' 1/2' 1 -1/2' X 2 -1/32' {11•r -N ANCHOR 1 -7/t4' 2 -3/4- 3' 1 -3/4' 3 -1/4' 4' 1 -6 /4' X 2- 16/32' DROP-IN ANCHOR 2 -1/4' COPPER TUBE 2 -3/4' 4-3/4• {' 3/4' 1 -3/4' X 3 -1/4', DRP. -N ANC. 3 -6/14' 5 -1/2' {' N/A I N/A N/A N/A No. I Date 1 2/9/2 2 4/14, 1/4" TAP 2 1/2" TAP WATER FLOW SWITCH PRESSURE GAUGE -I TO SPRINKLER Fire Sprinkler Piping Plan SCALE: 1/8"44" 1 " DRAIN FOR 1 CONTROL VALVE'` ,« DRAIN /TEST ASSEMBLY 11/ DRAIN FOR 2% " CONTROL VALVE a 1/2" RISER PIPE RISER CLAMP al -LINE MODEL 13373CTC OR EQUAL) MIN L' THICK MEDIUM DENSITY NEOPRENE 3XEEL P STEEL PLATES CONCR. FLOOR (CLUE TOGETHER WITH NEOPRENE PAD TO FORM ONE UNIT. USE CONTACT • • CEMENT). ELEVATI ❑N SEE FIRESTOP DETAIL 1 1/4" DRAIN r 3. LAB PLAN VIEW 3' NOTES PROVIDE RISER CLAMP IENI STRAPS AT EVERY OTHER FLOOR FIRE S P R 1 N K L E R CONTROL VALVE ASSEMBLY DETAIL MAXIMUM DISTANCE BETWEEN HANGERS NOMINAL PIPE SIZE (in.) 3/4' 1" 1 -1/4" 1 -1/2" 2" 2 -1/2" 3" 3 -1/2" 4" 5" G" /" STEEL PIPE EXCEPT N/A 12 -0 12 -0 15 -0 15 -0 15 -0 15 -0 15 -0 15 -0 15 -0 15 -0 15 -0 THREADED LIGHTWALL THREADED LIGHTWALL N/A 12 -0 12 -0 12 -0 12 -0 12 -0 12 -0 N/A N/A N/A N/A N/A STEEL PIPE COPPER TUBE 9-0 8-0 10 -0 10 -0 12 -0 12 -0 12 -0 15 -0 15 -0 1 15 -0 15 -0 15 -0 CPVC 5 -6 6-0 6 -6 7 -0 2 -0 1 9 -0 12 -0 N/A N/A N/A N/A N/A POLYBUTYLENE (IPS) N/A 3 -9 4 -7 5 -0 5 -11 N/A N/A N/A N/A N/A N/A N/A POLYRUTYLENE (CTS) 2 -11 3 , 4� R3 -11 4 -5 5 -5 N/A N/A N/A N/A N/A N/A N/A rProject Revisions B y Water Supply Information Design Criteria Sprinklers/ Spacing SUBMIT FOR APPROVAL JRGN Static Pressure 55 PSI System No. Symbol, Qty Size K Temp Description SINS MERSEY CHARTER SCHOOL PER CITY COMMENTS JRGN Residual Pressure 53 PSI Design Area Area #1 Area #2 0 9 1/2" 5.6 155 TYCO -QUICK RESPONSE WHITE TY -FRB SEMI REC PENDENT TY -3231 , .� x1 l •.�• 5876 SW 68 ST g y Fire st ���} Pitot Reading 42 Density 10 GPM SQ.FT 10 GPM SQ.FT Mi Flow In G.p.m. 1860 Design Area S.f. 225 225 .'73 1 U mi, Florida 33143 Date Of Test 2/9/09 Psi Req'd m City Main 54.93 54.5 P R I N *T �„ anfc� ^wlnf fi Time Of Test 12:15 Gpm Req'd •City Main 306.7 250.3 �+ or Test Taken By LT M FERNANDEZ Gpm Req'd 0 Dasr 50.06 39.72 4 sy.t.R1 Mr.'1 Date: 2/9/20A9 /; T' Drawn Iy: scale: " , " - No. Spkr. In Dsgn. Area 9 9 All Fire Sprinklers 1/f1= 1 -0 Ch{ck{r ty: AHJ: i Hydrant Location 5876 SW 68 ST Elev. 0 Highest Spkr 10 20' 7492 N.W. 8nd Street All Fire Sprinklers Authority Hovin Jurisdiction Medley,Florida 33126 Ti1i1 Ads' 244 � _ Domestic /outside Hose 100 100 , TEL:(305) 403 -4455 FAX:(305) 403 -44118 Contract No. Total This Sheet State Certification # 56528000012005 09_ P-3 Of 3 r