Loading...
14-1164-010Plumbing Floor Plan Scale: 3/8" : V -0" 5GOi=E OF WOR<: - REPLACE ALL PLUMBING= FIXTURES -NEW WATER SUf= ='LY LINES -NEW INSTANT WATER HEATER -ALL EX15TING SANITARY LINES ARE EXI5TING TO REMAIN PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION B. DRAWINGS: Refer to all drawings for coordination of the EXISTING SANITARY LINE plumbing work. SANITARY LINE — — — — — VENT LINE GW GREASE WASTE LINE —�-- —�- SAFEWASTE LINE CD CONDENSATE LINE — COLD WATER LINE -- HOT WATER LINE labor. GATE VALVE FCO FLUSH CLEAN OUT per foot minimum for 3" and larger and at 1/4" slope FLOOR PENETRATION for 2 1/2" pipes and smaller. MECHANICAL SHOCK ARRESTOR F. ALL materials shall be new, free of defects and correctly 7. VALVES: Domestic water valves shall be of bronze body, WCO WALL CLEANOUT VTR VENT THRU ROOF COOG CLEANOUT ON GRADE HB HOSE BIBB heaters, and plumbing fixtures. No work shall proceed without SHUT OFF VALVE ON RISER the approval of these submittals. FLOOR DRAIN W/ 3. PLUMBING FIXTURES: Fixtures shall be as selected by owner TRAP RESEAL GENERAL PLUMBING NOTES: 1. A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code and with all applicable regulations. F. Condensate drain: DWV Copper pipe & fittings. B. DRAWINGS: Refer to all drawings for coordination of the G. Domestic water supply assembly. Chrome finish tubing with angle off valves. plumbing work. VENT C. ARRANGE AND PAY for all permits, licenses, inspections 5. ALL AUTOMATIC ELECTRIC water heaters shall meet the and tests. Obtain the required certificates and present standards of the latest energy efficiency code. to owner. 6. PIPING TEST AND DISINFECTIONS: D. GUARANTEE: The completed installation shall be fully A. Test: All sanitary and domestic water supply piping shall guaranteed against defective materials and /or improper be tested for leaks before piping is concealed or connected workmanship for a minimum of one year for material and to equipment and plumbing fixtures. labor. B. Disinfection: All domestic water piping shall be E. ALL HORIZONTAL SANITARY PIPING shall slope at 1/8 inch disinfected by introducing a solution of calcium per foot minimum for 3" and larger and at 1/4" slope hypochlorite of 50 parts per million of chloride and as for 2 1/2" pipes and smaller. per AWWA Standards. F. ALL materials shall be new, free of defects and correctly 7. VALVES: Domestic water valves shall be of bronze body, labeled with their appropriate listing agency. sweat ends. 2. SHOP DRAWINGS: Contractor shall submit for approval, within 8. HOSE BIBBS: Shall be 3/4 inch. rough brass construction with 30 days of signing contract, a minimum of five copies of fully shut off valve and vacuum breaker. descriptive literature, including but not limited to: water 1/2" heaters, and plumbing fixtures. No work shall proceed without 9. ALL OUTDOORS FLOOR clean outs shall be terminated up to grade the approval of these submittals. and shall be marked. 3. PLUMBING FIXTURES: Fixtures shall be as selected by owner 10. CONTRACTOR SHALL COORDINATE exact location of all plumbing system piping before starting any work. Notify and shall be furnished and installed by this contractor. Fixtures shall be complete with drains, traps, supplies and any other Architect /Engineer of any deviations from design drawings. accessory required. Fixtures and faucets shall comply with the 11. CONTRACTOR SHALL provide all necessary labor and materials FBC Water saving standards. for a complete "turn -key" plumbing system. 4. MATERIALS: PIPING 12. CONTRACTOR SHALL keep accurate as -built dwgs on the field and A Drainage and Vent piping (Below Grade): shall be hub and spigot service weight provide them to owner once job is complete. cast iron with gasketed push -on joints. Polyvinyl Chloride (PVC) plastic pipe ((TYPE 13. CONTRACTOR SHALL familiarize himself with job site and with all DWV) ASTM D 2665, ASTM D 2949, CSA B181.2) is acceptable. construction documents including architectural, electrical. HVAC, and B. Drainage and vEnt piping (Above Grade): shall be hubless service weight cast iron structural dwgs, prior to bidding. Adjustments in the plumbing system to with neoprene gaskets and stainless steel band joints. Polyvinyl Chloride (PVC) accomodate other disciplines should be expected, and shall not represent plastic pipe ((TYPE DWV) ASTM D 2665, ASTM D 2949, ASTM F 1488, CSA B181.2) additional costs to owner. Notify Architect /Enigneer of any discrepancies is acceptable. prior to commencement of work. C. Water piping (Below Grade): shall be copper type "K" ASTM B -88 with wrought 14. Provide wall cleanouts at the base of every stack. copper fittings and 95 -5 soldered joints. Paint with bitumastic when installed in 15. CONTRACTOR SHALL obtain insuranceto protet against public liability grade, and property damage for the duration of work. Water piping (Above Grade): shall be copper type "L" ASTM B -88 with wrought 16. CONTRACTOR SHALL use dimensions in architectural drawings to copper fittings and 95 -5 soldered joints. CPVC (Chlorinated Polyvinyl Chloride) ASTM rough -in plumbing work. D 2846 pipe and tubing with CPVC plastic fittings ASTM F 437 is acceptable. D. All piping in return plenum shall not be PVC or CPVC, only metallic material will be use within the plenum Area E. Insulated all hot water and condensate drain piping. LOH LUIS O. DE LA HOz PE# 73932 ._,. BB57 NW 17BTH ST MIAMI, FL 33018 PHONE: (305) 903 -BB 16 LODELAHOZ @YAHOO.Es - • ,ft t� ••• N •; i �O; 2 :CL: �: �� • u.! Vii• � '• ....•� �Q,' �s` S1O��. •#$less Luis 0. de la Hoz, PE Lie# 73932 W PLUMBING FIXTURE CONNECTION SCHEDULE NO. DESCRIPTION WASTE VENT WATER REMARKS COLD HOT WG WATER CLOSET 3" 2" 1/2" FLUSH VALVE TYPE TANK, 1.28 GPF, FLOOR MOUNTED. LAV LAVATORY 1 1/2" 1 1/2" 1/2" AS SELECTED BY OWNER. PROVIDE 1.0 GPM FAUCET yyM CLOTHES WASHER 3" 2" 1/2" 1/2" RECESSED BOX GUY GREYPT200 OR EQUAL SH SHOWER [1] 2" 2" 1/2" 1/2" PROVIDE 1.5 PM SHOWERHEAD LSK LAUNDRY SINK 2" 2" 1/2" 1/2" AS SELECTED BY OWNER. PROVIDE 1.0 GPM FAUCET KSK KITCHEN SINK 2" 2" 1/2" 1/2" AS SELECTED BY OWNER. PROVIDE 1.0 GPM FAUCET [1] PROVIDE ANTI —SCALD VALVE. NOTES: 1.— All exposed trim, such as P— traps, angle stops, and supplies shall be chrome plated. 2.— All fixtures shall comply with Reference Standards as per FBC 2007 Plumbing 406 through 421. 3.— All Plumbing Fixtures to be specified by Architect. Please see Architectural Drawing for further information. LOH LUIS O. DE LA HOz PE# 73932 ._,. BB57 NW 17BTH ST MIAMI, FL 33018 PHONE: (305) 903 -BB 16 LODELAHOZ @YAHOO.Es - • ,ft t� ••• N •; i �O; 2 :CL: �: �� • u.! Vii• � '• ....•� �Q,' �s` S1O��. •#$less Luis 0. de la Hoz, PE Lie# 73932 W