14-1164-009ELECTRICAL NOTES ELECTRICAL LEGEND r,_ ALL WORK SHALL BE PERFORMED TO MEET THE REQUIREMENTS OF THE GOVERNING EDITION OF THE NATIONAL ELECTRICAL CODE (N.E.C), LOCAL AND STATE CODES AND ANY OTHER APPLICABLE CODES AND STANDARS. SWITCH (+48" CL, AFF UNLESS OTHERWISE NOTED.) BLANK = SINGLE POLE 2 = DOUBLE POLE 2- ALL WIRING SHALL BE COPPER (CU) THWN INSULATION. 3 = THREE-WAY 4 = FOUR-WAY D = DIMMER Mo= OCCUPANCY SENSOR 3- ALL CIRCUIT BREAKERS SHALL BE RATED AT MINIMUM OF 10,000 AIC. DUPLEX RECEPTACLE, WALL. (+18" CL, AFF UNLESS OTHERWISE NOTED.) 4- PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CHECK NAMEPLATE DATA OF ALL "GFI" GROUND FAULT TYPE, `WP- WEATHER PROOF. EQUIPMENT FOR REQUIRED VOLTAGES, MINIMUM CIRCUIT AMPACITY, AND OVER CURRENT DUPLEX RECEPTACLE, WALL. BOTTOM HALF SWITCHED. PROTECTION. (+18" CL, AFF UNLESS OTHERWISE NOTED.) 5- ELECTRICAL PLANS AND CALCULATIONS WERE BASED ON INFORMATION PROVIDED BY OWNER DUPLEX RECEPTACLE. (+48" CL, AFF UNLESS OTHERWISE NOTED.) AGENT. ELECTRICAL CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND ADJUST ACCORDINGLY, TWO DUPLEX RECEPTACLES IN TWO GANG OUTLET BOX "D" DESIGNATION CHANGES TO BE REFLECTED IN THE DRAWINGS. MEANSDEDICATED. (+18- CL, AFF UNLESS OTHERWISE NOTED.) 6- THE ELECTRICAL DESIGN IS BASED UPON THE AVAILABLE INFORMATION AT DESIGN TIME AND DUPLEX RECEPTACLE. FLOOR MOUNTED. THE CONTRACTOR SHALL REVIEW NAMEPLATE DATA AND MANUFACTURER SUPPLIED LITERATURE FOR ALL PIECES OF EQUIPMENT PRIOR TO ROUGH ELECTRICAL WIRING. THE CONTRACTOR SHALL CHECK SINGLE RECEPTACLE, WALL MOUNTED. ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE AND AMP RATING PRIOR TO INSTALLATION. THE (+18" CL, AFF UNLESS OTHERWISE NOTED.) CONTRACTOR SHALL CONTACT ENGINEER PRIOR TO ANY FIELD ADJUSTMENT. 7- ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. SPECIAL PURPOSE RECEPTACLE. NEMA CONFIGURATION AS NOTED, WALL MOUNTED. 8- ALL NEW CONDUCTORS SHALL BE RUN IN CONDUIT (METALLIC TYPE) UNLESS OTHER it TELEPHONE' OUTLET, WALL MOUNTED. SPECIFICATIONS APPLY AS PER NEC. AND LOCAL CODES DATA OUTLET, WALL MOUNTED. 9- IF PVC CONDUITS ARE USED FOR UNDERGROUND FEEDERS, AN EQUIPMENT GROUND COMB. DATA OUTLET-TELEPHONE OUTLET, WALL MOUNTED. CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250 - 122 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. 0 TV OUTLET, WALL MOUNTED. 10- TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED REFLECTING ALL Q JUNCTION BOX. CHANGES AND ADDITIONS. 0 LIGHTING FIXTURE TYPE DESIGNATION. 11- RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE CEILING MOUNTED FLUORESCENT LIGHTING FIXTURE. INSTALLATION. ELECTRICAL CONTRACTOR TO FIND BEST POSSIBLE ROUTE FOR ALL CIRCUITS. 12- THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL I e FLUORESCENT LIGHTING FIXTURE STRIP. CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 6�% CHANDELIER PENDANT LIGHT 13- CONTRACTOR TO VERIFY ADJUSTMENT FACTORS FOR MORE THAN THREE CURRENT-CARRYING W CONDUCTORS IN A CONDUIT ACCORDING TO TABLE 310-15(b)(2)(a) NEC. 0 CEILING MOUNTED (RECESSED) INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. 14- ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ARCHITECT TO FIELD VERIFY INSTALLATION FOR OUTLETS, LIGHTING FIXTURES AND ELECTRICAL EQUIPMENT. CEILING MOUNTED (SURFACE OR PENDANT) INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE, 15- DO NOT INSTALL SINGLE SMOKE DETECTORS CLOSER THAN 3 FEET FROM ANY HVAC AIR DIFFUSERS. (�H WALL MOUNTED INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. 16 - ALL NEW RECEPTACLES SPECIFIED IN NEC 210.8, 120 V. 15 OR 20 AMPS, SHALL HAVE 177 WALL MOUNTED STEP LIGHTS GROUND FAULT CIRCUIT INTERRUPTER PROTECTION (GFCl PROTECTION). JUNCTION BOX FOR LIGHTING FIXTURE AND 17 - ALL NEW 120 V, SINGLE PHASE 15 OR 20 AMPS BRANCH CIRCUITS FOR FAMILY ROOMS, FAN CEILING MOUNTED DINNING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS, SHALL BE PROTECTED BY AFCI BREAKERS. (NEC OUTDOOR FLOOD LIGHT 210.12 (B). 18 - ALL NEW RECEPTACLES SPECIFIED IN NEC 210.52, 120 V, 15 OR 20 AMPS, SHALL BE FAN MOTOR MOTOR CONNECTION. LISTED TAMPER- RESISTANT RECEPTACLES (NEC 406.11). o"= 19- NON-LOCKING RECEPTACLES IN DAMP AND WET LOCATIONS SHALL BE LISTED WEATHER c" DISCONNECT SWITCH. "= AMP. FUSE "F"=FUSIBLE. C=O NOT FUSED PHASE, "b"= AMP FRAME, RESISTANT TYPE WITH A WEATHER PROOF ENCLOSURE AS PER NEC 406.8 (A) & (8). 20- BOXES, CONDUIT BODIES, AND FITTINGS INSTALLED IN WET LOCATIONS SHALL BE LISTED FOR GROUND CONNECTION. USE IN WET LOCATIONS AS PER NEC 314.15(A) BRANCH CKT HOME RUN, LIGHTING NOTES DENOTE NUM. OF UNGROUNDED SERVICE WIRE DENOTE NEUTRAL WIRE 1- REFER TO ARCHITECTURAL CEILING PLAN FOR EXACT LOCATION OF ALL LIGHT FIXTURES. DENOTE GROUND WIRE 2- REFER TO ARCHITECTURAL ELEVATIONS FOR FINAL MOUNTING HEIGHTS OF ALL WALL MOUNTED rff'l ELECTRICAL METER LIGHT FIXTURES. UNLESS NOTED OTHERWISE, ARCHITECTURAL ELEVATIONS SHALL DICTATE MOUNTING HEIGHTS OF ALL FIXTURES. ELECTRICAL PANEL 3- COORDINATE FINAL PLACEMENT OF LIGHT FIXTURES IN ALL MECHANICAL SPACES WITH THE FINAL INSTALLED LOCATIONS OF ALL MECHANICAL DUCTWORK AND PIPING. SD SINGLE SMOKE DETECTOR. -SHALL BE 120V WITH BATTERY BACK UP, 4- CONTRACTOR TO VERIFY WITH OWNER ARCHITECT LIGHTING FIXTURE TYPE AND SPECIFICATIONS -ALL SMOKE DETECTOR WIRING SHALL BE MADE SO THAT WHEN ONE IS BEFORE INSTALLATION. ACTIVATED THE REST IN THE UNIT SHALL BE ACTIVIATED. -LOCATED 36" MINIMUM FROM ANY A/C SUPPLY GRILLE 5- ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE MANUFACTURER -LOCATED 36" MINIMUM FROM REGISTER, BATH OR KITCHEN DOOR FBC 905.2 CEILING, WALL OR POLE INSTALLATION SYSTEM. 6- RECESSED LUMINARIES INSTALLED IN THE RSIDENCE THERMAL ENVELOPE SHALL BE SEALED TO SINGLE-STATION CARBON MONOXIDE DETECTOR. LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. ALL RECESSED (INSTALL ACCORDING FBC-2010 R314) LUMINARIES SHALL BE is -RATED AND LABELED AS MEETING ASTMI E 283 (AIR TIGHT) AS PER FBQ FBC 313.4 REQUIRES CARBON MONOXIDE ALARMS WITHIN 10 FEET OF EACH EC 502.3.8 ROOM USED FOR SLEEPING PURPOSES 7- CONTRACTOR TO VERIFY FLUORESCENT LUMINARIES W/DOUBLE ENDED LAMPS TO BE PROVIDED ,W/INTERNAL DISCONNECTING MEANS TO DISCONNECT SIMULTANEOUSLY AL CONDUCTORS OF THE BALLAST, INCLUDING THE GROUNDED CONDUCTOR AS PER NEC 410.130 (!D 8- LUMINARIES SHALL NO BE USED AS RACEWAY FOR CIRCUIT CONDUCTOR UNLESS LISTED AND MARKED FOR USE AS A RACEWAY. 9- A MINIMUM OF 50% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. (FBC 404.1) /4 PI PrTPIrAl - r_PKIPPAI KIOTP(Z Ar1r1pr_x/iAT10KI (zvurzoi 4z &Kin I i=r_i;:Kin SCALE- NTS FPL SERVICE 120/208V, 3PH 4WIRE EXTERIOR STUDIO METER SCHEDULE 'A' A.R. Date 1 OOA Scale AS SHOW MAINS M.C.B. 100 AMP 1 ODA 10,000 A.I.C. BUS M.C.B. OF SHEETS VOLTAGE 120/24OV- 1 PH,4W DESCRIPTION WIRE & LOAD POL CKT. CKT. POL�-' LOAD BONDING DESCRIPTION COND. SIZE (V.A.) tR 11P No- A 8 No. TRIP (V.A.) COND. SIZE SMALL APPL. # 12-1/2" 1,500 1 TERMINATION 2 _),,--20 1,500 #12-1/2" WALL AC :.0 DEVICE(NE 3 4 2 8,500 #8-3/4- 250,94) MICROWAVE #12-1/2"_ 1,200 1 20 5 6 40 HEATER REFRIGERATOR #12-1/2" 1,200 1 7 8 1 1,500 #12-1/2- BATH RECEPT SPACE 9 10 1,000 #14-1/2" GENERAL LIGHTS WIRING LEGEND 11 2 H, 1,000 4 14-1 /2- LIGHTS (D WEATHER HEAD CONNECTION LOAD CALCULATION PANEL 3-#4 THWN CU IN 2-GALVANIZED COLD WATER 11 RIGID CONDUIT. PIPE 3 3-#4 THWN CU IN 1 1/4C" (2) 5/8- X 10' DRIVEN GROUND RODS, COPPERCLAD, BUILDING STEEL a 1 - #8 CU IN GROUND. TO BE SEPARATED 6'-0" FOUNDATION REMAINDER 0 40% = (16,400-10,000) X 0.4 = 2,560 VA MINIMUM Q 1-#6 THWN CU GROUND. r-2 ELECTRICAL - RISER DIAGRAM P J TOTAL AMPS = 55 AMPS PER PHASE 11 � Sca1z. NM K-4 _'� ELECTRICAL - FLOOR PLAN E-1/ T-1 /47=- 1 1-0 1 ELECTRICAL PANEL SCHEDULE 'A' A.R. Date TYPE : LOAD CENTER Scale AS SHOW MAINS M.C.B. 100 AMP MOUNTING : FLUSH 10,000 A.I.C. BUS RATING 100 AMP OF SHEETS VOLTAGE 120/24OV- 1 PHASE-3WIRE DESCRIPTION WIRE & LOAD POL CKT. CKT. POL�-' LOAD WIRE & DESCRIPTION COND. SIZE (V.A.) tR 11P No- A 8 No. TRIP (V.A.) COND. SIZE SMALL APPL. # 12-1/2" 1,500 1 1 2 _),,--20 1,500 #12-1/2" WALL AC SMALL APPL. #12 -1/2" 1,500 1 3 4 2 8,500 #8-3/4- TANK LESS WATER MICROWAVE #12-1/2"_ 1,200 1 20 5 6 40 HEATER REFRIGERATOR #12-1/2" 1,200 1 7 8 1 1,500 #12-1/2- BATH RECEPT SPACE 9 10 1,000 #14-1/2" GENERAL LIGHTS SPACE T I 11 2 H, 1,000 4 14-1 /2- LIGHTS AFCI TYPE BREAKER LOAD CALCULATION PANEL TOTAL CONNECTED LOAD = 18,900 VA A/C LOAD = 1,500 VA VA CONNECT LOAD-A/C LOAD= 16,400 VA FIRST 10KVA 0 100% = 10,000 VA REMAINDER 0 40% = (16,400-10,000) X 0.4 = 2,560 VA DEMAND = 10,000 + 2,560 + 1,500 = 13,000 VA TOTAL AMPS = 55 AMPS PER PHASE r3_ ELECTRICAL - PANEL SCHEDULE E-1 J SQqL- NTS N N N 11 Eiigineedng Design, Inc. C.A. #: 29235 2102 NW 17th ST D,306 Miami, Fl 33125 Email: Uengineering@yahoo.com ceff. 786-144-6712 06666000 .••off *OD s I G • N • :6 %r • C 110 FLO 0 0 L I 0009-Es,sk 009050 ANTONIO RODRIGUEZ P.E. #:70746 Ir REVISIONS No Description t5 V) I- uj -q j-Z Lu CN 1% * Lu !R IM (D cf) Co CO LO X uj 0 �11 'Drawn A.R. Checked A.R. Date 10-02-14 Scale AS SHOW Jon NO- TL-14-150 Sheet E-1 OF SHEETS