14-1164-00616' -1" L FOUNDATION FLAN SCALE: 1/4" =1' -0" 0 r is FOOTING SCHEDULE MARK SIZE REINFORCEMENT COMMENTS WF -lh 16" CONT X 12" 20 S CONT PROVIDE 205 X 5' -0" BENT 30" EACH WAY CORNER BAR 6 CORNERS 4 INTERSECTIONS LON 45 VERT. IN BLOCK CELLS FILLED WITH CONG, GROUT, LUIS O. DE LA HOZ ' m _ SEE PLANS FOR LOCATION 8" CONC. BLOCK WITH S GAGE P E# 73932 JOINT REINF. 0 1Es" c/G (LADDER TYPE) 8857 NW 17BTH sr PROVIDE t 5" x 5" SAID -CUTS GLEAN -OUTS AT 4' -0" c/c EACH MIAMI, FL 3301 B VERT. BAR PHONE: (305) 903-8816 NOTES: 3 LODELAHOZQ4 YAHOO.E5 '/2" EXPANSION OINT MATERIAL. 4" CONC. SLAB DRILL 3/411-0 HOLES x 41/2 REINF. WITH DEEP 4 FILL WITH 1. PROVIDE 1 05 VERT. IN BLOCK CELL FILLED WITH CONC. GROUT 6 "xro "- W1.4xW1.4 Tlum. EPDXY GROUT Q EACH SIDE OF OPENING. TYPICAL GRADE. ;1 e.... .��. ... . 2: ALL MASONRY BLOCKS WALLS SHALL BE REINFORCED WITH 05 m 48" VERTICAL IN BLOCK CELLS FILLED WITH CONC. GROUT. TYPICAL, OR AS INDICATED ON PLANS, i I I! I I I� I =I I I- III = III =I I " SEE PLAN FOR LOCATION 1 04 DOWELS 31-0110 24" 3.- PROVIDE CLEAN -OUTS AT ALL WALL VERTICAL REINFORCEMENT I I I =I I I- I \ AT 4' -0" c/o. MAXIMUM. I� f wI l I111 . 4"" CON(. SLAB N — — EXISTING 4.- ADD 2 04 DIAGONAL x 4' -0" LONG AS SHOWN, TYPICAL VAPOR BARRIER 4.- AT ALL CORNERS. ;;; WELL SAW CUT EXISTING 4" LONG. SLAB 5.- PROVIDE 05 BOTTOM CORNERS BARS AT ALL CONT. FOOTING COMPACTED ,. FILL. INTERSECTIONS, EXTEND 30" INTO EACH FOOTINGS p :. WF -16, SEE 6: HOOK ALL VERTICAL REINFORCING INTO TIE BEAM ,a SCHEDULE • ... , ,4 ~ 1.- COORDINATE ALL 8 "x8" CONC. SILL WITH ARCHITECTURA DRAWINGS. FOR REINF. REINF. WITH 2 05 CONTINUOUS 4 EXTEND 6" INTO WALL EACH END. 8.- SEE SHEET 5-1 FOR GENERAL NOTES S.- CONTRACTOR MUST COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS, 10.- COORDINATE ALL SLAB DROPS AND DEPRESSIONS WITH SECTION ARCHITECTURAL AND MECHANICAL DRAWINGS. 11.- TOP OF SLAB ELEVATION - 0' -0" TYPICAL UNLESS SCALE; 3/4 "= 1' -0" � NOTED OTHERWISE ON PLAN AS THUS OL TOP OF SLAB EL, 12.- 4" CONC. SLAB OVER 6 MIL. VISQUEEN ON CLEAN FINE SAND SUPERVISED FILL COMPACTED IN 12" LAYERS TO 95% OF THE MODIFIED PROCTOR DENSITY TEST REINFORCED W/ 6x6 -W1.4 x W1.4 WELDED WIRE FABRIC PLACED 1 1/2" FROM TOP OF SLAB 13: CONTRACTOR MUST PROVIDE TERMITE TREATMENT 4 FUMIGATOR CERTIFICATION REPORT. TERMITE TREATMENT OF SOILS UNDER SLAB ON GRADE SHALL BE PERFORMED BEFORE POURING SLAB. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES 2 05 DOWELS x3' -0" OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED DRILL 3/44, HOLES x 41/2" AS A PREVENTIVE TREATMENT TO NEW CONSTRICTION DEEP 4 FILL W/ EPDXY NEW CON(. TB, SEE PLANS 14.- CONTRACTOR MUST NOTIFY ARCHITECT / ENGINEER PRIOR TO GROUT. PROCEEDING WITH THE WORK ANY CONDITION DIFFERENT FROM WHAT IS SHOWN IN THESE PLANS AS ENCOUNTERED IN THE FIELD 15.- DIMENSIONS SHOWN SHALL BE FIELD - VERIFIED. ANY DISCREPANCIES SHALL BE NOTED AND THE ENGINEER EXIST. CONC. TB. OF RECORD NOTIFIED BEFORE CONTINUING WITH THE WORK SOIL STATEMENT: IL IF +'3 DOWELS m 24" c%. BASED ON A VISUAL INSPECTION ON SITE, THE SOIL IS SAND, WITH AN ALLOWABLE BEARING CAPACITY OF 2000 P.S.F. AS PER F.5 G. 2001 BASED ON THIS, THE FOUNDATION HAS BEEN DESIGNED FOR A MAXIMUM NEW BLOCK WALL ALLOWABLE SOIL BEARING CAPACITY OF 2000 P.SF., AT THE TIME OF DRILL 1/2" 0 HOLES x 4" CONSTRUCTION A LICENSED ARCHITECT OR PROFESSIONAL ENGINEER DEEP 4 FILL W/ EPDXY SUBMIT TO THE BUILDING OFFICIAL A LETTER ATTESTING THAT THE SITE GROUT. HAS BEEN OBSERVED AND THE FOUNDATIONS CONDITIONS ARE SIMILAR TO — THOSE .UPON WHICH THE DESIGN IS BASED SC -1, SEE SCHEDULE CONCRETE MASONRY NOTE: EXIST BLOCK -WALL ALL CONCRETE MANOORY UNITS (CMU) SHALL CONFORM -7 TO ASTM C SO "STANDARD SPECIFICATIONS FOR 2 05 DOWELS x V -0" HOLLOW LOAD BEARING CONCRETE MASONRY UNITS, WHIT A NET AREA COMPRESSIVE STRENGTH OF MASONRY OF 1900 P.S.I. DRILL 3/4"0 HOLES x 41/2 NEW CONC. FTG., DEEP 4 FILL WITH SEE PLANS -1 EPDXY GROUT EXIST, CONC. FTG. NEW FTG. EXIST. FTG. DETAIL SCALE; 3/4 "z 1' -0"