14-1164-002i- -Area of work
it I(
n -05 ii
t I II 1 1
EXISTING
BEDROOM I'
I IIII
IIII
n -01 illl
IIII
(
I a n -07
�Jj I
C i iI I� ,
I
t t
L - -- ---------- - - - - -�
n-03! - - - - - - n -03
(TYPICAL)
Floor Plan I Existing
Scale: 1/4": 1' -0"
—/ AREA of We
FiRE DAMAGED AREA OF WORK LOH
existing top m n
of roof _ n m_ LUIS 0. DE LA H o z
,9' -2 " -a
PEA' 73932
8857 NW 17BTH ST
MIAMI, FL 33018
PHONE: (305) 903-8816
LODELAHOZ @YAHOO.E5
••••`S`. k 8 000 ••
existing finish •.•! "Zi ..... y�1 •••
floor elev 4•OP•.•• N S '••.• ;
01 -011 • :Ws
LU
A .•' ••
•• IQ • -
• • ••••�•• Q� ••
. I1 -I�• �r„stwe�o� '
Luis 0. de la Hoz, PE
Lic# 73932
East Elevations Existing
Scale: 1/4,,: 1' -0"
cxisl.ing area no work
East Elevations Existing
Scale: 1/4": 1' -0"
North Elevations Existin
L------ - - - - - -- - - - -- --- -- ------ - - - -J
Roof Plan I Existing
Scale: 1/4": 1' -0"
FIRE I) AMAGE RE FA i R SCOFF OF: WORK
ARC: HITECTURAL STRUCTURAL
Provide new foundation and exterior conc. block wall
due fire damage of existing bearing wall.
l: Existing window fire damaged to be replaced. Existing roof framing to be replaced.
2: Existing interior partition fire damaged to be replaced. LECTRiCAL
Existing exterior bldg shell to be removed. New cone. block wall J 9
be provide. All existing electrical fixtures, wires and panels to be replaced.
3: Existing plumbing fixtures to be replaced. New electrical service for this area.
4; kitchen counter top and cabinets to be replaced. PLUMBING
5: All existing doors to be replaced. Existing drainage pipes and water supplies lines are existing to
Interior furring and insulation to be replaced. remain, no fire damage for this items.
7: Existing roof to be replaced. MECHANiCAL
g: All interior finishes to be replaced. Existing wall mounted A/C unit to be replaced.
9: Existing roofing to be replaced.
10: Existing floor tiles to be replaced.
ID EMOL. i T i ON LEGEND
Gypsum board partition to be removed
r�
�E Door to be removed
Existing concrete Block wall to remain
Alteration level -2 and Repair
(FB.0 Existing 2010) (Existing building)
Asbestos Notes
This notice is provided for information only. Asbestos
abatement is not covered under the scope of services
provided and is not addressed in these drawings.
Services relating to asbestos abatement, demolition,
removal, abatement planning, etc. shall be by others and
shall be coordinated between the Owner and Owner
retained specialist.
I )EMOI_ITION NOTES:
N- 01:AII existing exterior wall to be removed due fire damage
New cone. block wall to be provided.
N- 02Existing kitchen counter and cabinets to be replaced.
N- 03Existing exterior windows and doors to be replaced.
N- 04Ex1sting plumbing fixtures to be replaced.
N- 05Existing floor the to be replaced.
N- 06Existing roof framing and roofing system to be replaced due
fire damage
N- OiExisting wall mounted ac unit to be replaced.
existing top
of roof
-
91- 2" qu
existing finish
floor elev
0' -0"
Area of work
L•�.�
I. Neither the owner, nor the Professional, shall be responsible for
damages resulting from the Contractor's work
2. Contractor is responsible for coordination of access to site and
acceptable times of work schedule with building management prior to
commencement of work
3. Under no circumstances shall the Contractor leave excavated
trenches, or parts of, exposed or open at the end of the working day,
weekends, holidays, or other times when the contractor is not
Present on site.
4. All debris from demolition work shall be disposed off site.
5. Contractor to comply with all OSHA, Federal, State, County, and City
ordinances and Safety requirements.
6. Contractor to verify location, elevation and condition of all existing
utilities prior to the start of demolition work
-1. Contractor to cap all plumbing lines as required.
a. Contractor to label all cut or disconnected electrical lines to identify
circuit on existing electrical panel.
S. Contractor to have approved Demolition permit prior to
commencement of demolition work
10. Contractor /Owner to have service disconnect letter from all required
utility companies prior to commencement of work
11. Contractor is solely responsible for complying with all Federal, State,
County, and Clty regulations for securing site.
12. Contractor "it be responsible for visiting the site prior to bidding
and familiarizing himself with all existing conditions affecting the work,
including but not limited to private and public utilities and other
support facilities.
13. Contractor shall comply with all applicable local, state and federal
building codes. Permit shall be posted in a visible place at all times.
14. Contractor shall avoid interference with the normal work flow and
proper functioning of all surrounding properties.
15. if the normal work flow of an area must be interrupted In order to
proceed with the schedule, proper notice must be given the adjacent
property owners being affected by such work, 3 days in advance, and
permission to be obtained prior to commencement of such work
16. Contractor to shore as required during demolition. Notify
Architect/Engineer of any problems and /or discrepancies or
inconsistencies immediately.
1 -7. Contractor shall be responsible for removing debris and
construction material from the site. Contractor shall also be
responsible for properly cleaning all areas both on a daily basis
and prior to final acceptance by the Owner.
Ia. items indicated by the Owner to be relocated and /or stored
must be carefully removed and stored to avoid damage.
IS. Contractor is responsible for including in his bid, work and
material costs for any change or alteration of adjacent areas to
be disturbed during demolition and constructions.
20. Contractor must notify immediately of any un- expected or
unknown conditions, any discrepancies with the drawings and /or
contract documents and any errors and omissions on the drawings
prior to bidding and proceeding with work
21. Contractor to inform t of discovery of any mold found.
Contractor to provide remediation options to Owner.
22. Contractor to inform of discovery of any asbestos found.
Contractor to provide abatement options to Owner.
W
a4:
Z4a.�.�
a w N i,
14
u,
0 CO) 4
tiQ��
CO 00
W
Project Number
issue Date
Revisions
Drawing Title
Demolition
Cad File Name
Sheet Number
0