14-946-032
CONVENIENCE TILT O r , � r � ' • � r r � SCALE: 3/16" = 1' -0" Q FIRE ALARM NOTES: 0 PROVIDE SMOKE DUCT DETECTORS FOR HVAC UNITS AS REQUIRED. COORDINATE THE INSTALLANTION OF ALL REQUIRED RELAYS AND CONTROL MODULES FOR THE HVAC EQUIPMENT. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION AND QUANTITY. 2 PROVIDE A SIGN INDICATING WHERE THE FIRE ALARM CONTROL PANEL LOCATION (FIRST FLOOR MAIN ELECTRICAL ROOM) s❑ SHUT DOWN THE AUDIO SYSTEM IN CASE OF ALARM COORDINATE IN FIELD ® DUCT SMOKE DETECTORS SHAL BE UL LISTED AND INSTALLED ACCORDING TO NFPA 72- 5.16.4.2 FIRE ALARM CONTRACTOR SHALL VERIFY AIR FLOWING SYSTEMS HAVING A CAPACITY GREATER 2000 CFM. SEE MECHANICAL DWGS. PROVIDE REMOTE TEST STATION FOR THOSE CONCEALED AC UNITS. FIRE ALARM SHOP DRAWINGS, SIGNED AND SEALED, AS REQUIRED BY THE JURISDICTION HAVING AUTHORITY ® THE SYSTEM TO BE INSTALLED IN ACCORDANCE WITH : F.B.C. 2010, N.F.PA 72 N.F.PA -101 AND N.E.C. ARTICLES 250, 300 AND 760. REFER TO FIRE ALARM DRAWINGS FOR CONCEPTUAL FIRE ALARM DESIGN. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR PERMIT. FOR ELEVATOR RECALL. DETAILS REFER TO THE FlRE ALARM DRAWINGS. SOUND SYSTEM NOTES 1. COORDINATE WITH OWNER FOR SCOPE OF AUDIO SYSTEM WORK FOR A COMPLETE INSTALLATION OF AUDIO EQUIPMENT, SPEAKERS, WIRING AND CONTROL. 2. PRIOR TO ROUGH -IN OF AUDIO DEVICES COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS WITH AUDIO SYSTEM DESIGN AND ARCHITECTURAL DWGS. 3. COORDINATE REQUIREMENTS WITH SOUND SYSTEM CONTRACTOR. (TYPICAL). 4. G.C. TO COORDINATE W /OWNER AREAS TO BE CONTROLLED BY EACH VOLUME CONTROLLER. :a• �1 1 � 1 a: «•� • 1 LEGEND FOR CONDUIT FOR SOUND SYSTEM SOUND 1 aNI�9 E� �� a (1) 3/4' EMPTY CONDUIT. STUBBED 6- INTO CLG. SPACE T- i COORDINATE LOCATION AND M k Q VOWUE CONTROL (TYP). IN IT ROOM 129 COORDINATE / AND QUhNTITIES © SOUND SYSTEM CABLE BY SOUND ADDRESSABLE SMOKE DETECTOR. CONTRACTOR REFER TO FIRE ALARM PLANS FOR VISUAL LAMPS CANDELA RATINGS (TYP.) cm �? C%2 'z o� c� W oa ^„moo -a %li map l0 `^enrSz CD ozo, -r c°o �+% ®Vw "15- Ley* Ww ;. a W d oNi^ 4rv�Z� 'xZoo z-O« e•� <w C o aa�-F_ 'Z' 'z , Cc J �rf Ci Z J O o7 C� wxw�ZW e'' Yir -�Ww �Zw °Z � °4 ®JZV, O w,JvwQ rrtW agog Lo xd a O w a m w L Q� t-24_ crO NUm LEGEND FOR CONDUIT FOR SOUND SYSTEM Q (1) 3/4' EMPTY CONDUIT. STUBBED 6- INTO CLG. SPACE M FOR SOUND SYSTEM WIRING BY SOUND CONTRACTOR Q p (TYP). IN IT ROOM 129 TO AUDIO RACK BY SOUND CONTRACTOR (TYP.) IN IT ROOM 129 +11111 2� i REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND QUANTITIES (TYP.) z 0 r- U lu z Z TO FIRE MARM o CONTROL PANEL. WITH z ' TO UNLOCK DOOR (IF REQUIRE) SEE DOOR HARDWARE DETAILS. AND SECURITY CONTRACTOR FOR INFORMATION ONLY N.T.S. I llllq� 11 I ii 111111i 1 FIRE ALARM DEVICES INTEGRATED TO THE BUILDING FIRE ALARM SYSTEM. THESE DRAWINGS ARE ONLY MINIMUM REQUIREMENTS. CONTRACTOR SHALL VERIFY THE EXISTING FIRE ALARM SYSTEM HAS ENOUGH CAPACITY IN ADDRESSING, LOADING, POWERING AND BATTER! TO ACCEPT NEW POWER BOOSTER AND ALL NEW DEVICES . PRIOR TO ORDERING, FINAL BIDS SHALL PRIOR TO FINAL BIDS AND /OR INITIAL JOB CONSTRUCTION. SHALL VISIT THE JOB SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS. NOTIFY THE ARCHITECT OR ENGINEER OF ANY DISCREPANCIES. SHUT DOWN THE AUDIO SYSTEM IN CASE OF ALARM PROVIDE NEW FIRE ALARM DEVICES TO MATCH EXISTING BUILDING STANDARD PRIOR TO BIDDING CONSULT FIRE ALARM MAINTENANCE COMPANY CONTRACTOR IS RESPONSIBLE FOR PROVIDING SIGNED do SEALED FIRE ALARM PERMIT DRAWINGS BY A FLORIDA REGISTERED ENGINEER. JMM CONSULTING ENGINEERS LLC IS NOT RESPONSIBLE FOR F/A PERMIT DWGS. FOR SECURITY SYSTEM CAMERA COORDINATE REQUIREMENTS WITH OWNER PRIOR TO ORDERING AND FINAL BID. FIRE ALARM LEGEND FIRE M ALARM STROBE LIGHT. Q p ADDRESSABLE FIRE ALARM PULL STATION. COMBINATION FIRE ALARM HORN /STROBE. CU? p ADDRESSABLE SMOKE DETECTOR. ODD TOR ADDRESSABLE SMOKE DUCT DETECTOR FIRE WARM CONTROL PANEL PB FIRE HARM POWER BOOSTER 011S " SOUND SYSTEM CABLE BY AUDIO / SYSTEM DESIGN VOLUME CONTROL BY AUDIO SYSTEM DESIGN z 0 r- U lu z Z TO FIRE MARM o CONTROL PANEL. WITH z ' TO UNLOCK DOOR (IF REQUIRE) SEE DOOR HARDWARE DETAILS. AND SECURITY CONTRACTOR FOR INFORMATION ONLY N.T.S. I llllq� 11 I ii 111111i 1 FIRE ALARM DEVICES INTEGRATED TO THE BUILDING FIRE ALARM SYSTEM. THESE DRAWINGS ARE ONLY MINIMUM REQUIREMENTS. CONTRACTOR SHALL VERIFY THE EXISTING FIRE ALARM SYSTEM HAS ENOUGH CAPACITY IN ADDRESSING, LOADING, POWERING AND BATTER! TO ACCEPT NEW POWER BOOSTER AND ALL NEW DEVICES . PRIOR TO ORDERING, FINAL BIDS SHALL PRIOR TO FINAL BIDS AND /OR INITIAL JOB CONSTRUCTION. SHALL VISIT THE JOB SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS. NOTIFY THE ARCHITECT OR ENGINEER OF ANY DISCREPANCIES. SHUT DOWN THE AUDIO SYSTEM IN CASE OF ALARM PROVIDE NEW FIRE ALARM DEVICES TO MATCH EXISTING BUILDING STANDARD PRIOR TO BIDDING CONSULT FIRE ALARM MAINTENANCE COMPANY CONTRACTOR IS RESPONSIBLE FOR PROVIDING SIGNED do SEALED FIRE ALARM PERMIT DRAWINGS BY A FLORIDA REGISTERED ENGINEER. JMM CONSULTING ENGINEERS LLC IS NOT RESPONSIBLE FOR F/A PERMIT DWGS. FOR SECURITY SYSTEM CAMERA COORDINATE REQUIREMENTS WITH OWNER PRIOR TO ORDERING AND FINAL BID.