14-946-031ILLUMINATION ELECTRICAL NOTES
1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION
OF LUMINAIRES (LIGHT FIXTURES).
2. ALL BRANCH CIRCUITS SHALL BE SIZED IN ACCORDANCE WITH N.E.0 -2008.
210 -19 REGARDLESS OF SIZES SHOWN ON PLANS OR PANEL SCHEDULES.
3. ALL EXIT SIGN AND EMERGENCY LIGHTING SHALL BE PROVIDED WITH RECHARGEABLE
BATTERY BACKUP AND CONNECTED AHEAD OF THE LOCAL LIGHTING (OCCUPANCY SWITCH)
COMPLY WITH NFPA - 101.7.9 & NEC - 700 -12 (E), NEC - 517.25 & NEC - 517.45.
4. MANUFACTURER AND CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER VENTILATION
AND TEMPERATURE CONDITIONS OF LUMINAIRES (LIGHT FIXTURES).
5. PRIOR TO ROUGH —IN OF ELECTRICAL DEVICES COORDINATE EXACT LOCATION AND MOUNTING
HEIGHTS.
6. ALL LIGHTING FIXTURES INSTALLATION AND CONTROLS SHALL BE INSTALLED PER
MANUFACTURER RECOMMENDATIONS BY LTG SUPPLIER SELECTED BY OWNER AND EC.
7. CONTRACTOR SHALL VERIFY CEILING CONSTRUCTION FOR EACH LUMINAIRE (LIGHT FIXTURE)
TYPE AND LOCATION.
8. ALL FLUORESCENT LUMINAIRES (LIGHT FIXTURE) WITH DOUBLE —ENDED LAMPS AND BALLAST
SHALL HAVE AN INTERNAL FACTORY INSTALLED DISCONNECTING MEANS IN COMPLIANCE
WITH NEC - 410.130 (G) (2008).
9. ALL OCCUPANCY SENSORS TO PROVIDE AUTOMATICALLY OFF— MANUAL ON.
CONTRACTOR TO VERIFY POSITION IN FIELD.
10. ALL OPEN WIRING ABOVE SUSPENDED CEILING SYSTEM SHALL BE RATED FOR USE IN A
RETURN AIR PLENUM. ALL CABLING SHALL COMPLY WITH N.F.P.A. STANDARDS.
11. SEE ARCHITECTURAL DWG FOR DIMENSIONS FOR WALL SCONCE PLACEMENT.
12. ALL FLUORESCENT LAMPS /BULBS TO BE WARM WHITE.
13. IN CASE OF GENERATOR MODE THE EMERGENCY LIGHT SWITCH SHALL TURN 100% ON ALL DIMED
LUMINAIRES
ADDITIONAL NOTES
FOR 120V 1— E. FANS : INSTALL 1P—TOGGLE SW MOTOR RATED IF FAN HAS INTERNAL THERMAL
PROTECTION. IF NO INTERNAL MOTOR STARTER W/ O.L. FURNISHED BY MECHANICAL CONTRACTOR
COORDINATE EXACT LOCATION WITH MECHANICAL DWGS. LOCATIONS SHOWN FOR MECHANICAL
UNITS ARE ONLY APPROXIMATE.
E.C. VERIFY THE CAPACITY REQUIREMENTS (FLA, MCA, AND MOCP), POLES AND VOLTAGE
FOR AHU EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO THE PURCHASE AND
INSTALLATION OF THE SAFETY SWITCHES, RACEWAYS, WIRING AND BRANCH CIRCUIT BREAKERS
* FUSED AS PER EQUIPMENT NAME PLATE
ACCESSIBLE JUNCTION BRANCH CIRCUIT FINISH SLAB
BOX
J--6
GRID SUPPORT
3/8" FLEXIBLE CONDUIT. NEXT TO FIXTURE
MAX 6FT. AS PER NEC 348.3
1918 L L ti rr I I U M 1116 rrl•• 'iii
LIGHTING FIXTURE, `— FINISHED CEILING
RECESSED FLORESCENT LT. FIXTURE CONNECTION DETAIL
N.T.S.
NOTES:
1.— ALL RECESSED LIGHT FIXTURES ARE TO BE CONNECTED AS DETAILED.
2.— ALL JUNCTION BOXES ARE TO BE READILY ACCESIBLE.
SWITCHING LABELS NOTES:
CONTRACTOR SHALL ARRANGE ALL SWITCHES AS NOTED AND
PROVIDE PERMANENT LABELS DENOTING SERVED AREAS.
COORDINATE WITH ARCHITECT AND ELECTRICAL CONTRACTOR
EXACT LOCATION ALL SWITCHES. AS PER NEC -404.8
LEGEND
(ae) — DENOTES SWITCH GROUP IDENTIFICATION— EMERGENCY POWER
(an) — DENOTES SWITCH GROUP IDENTIFICATION— NORMAL POWER
OE -1 — DENOTES CONNECT TO PANEL OE, CKT -1 OPTIONAL STANDBY
BA -1 — DENOTES CONNECT TO PANEL BA, CKT —I— NORMAL POWER
PE -1 — DENOTES CONNECT TO PANEL PE, CKT -1 EMERGENCY —POWER LOADS
LEGEND SYMBOL
`"J HALF— SHADED LIGHT FIXTURE DENOTES EMERGENCY TYPE
PROVIDED WITH A 1400 LUMENS EMERGENCY BATTERY UNIT TO
OPERATE ONE LAMP DURING POWER FAILURE. PROVIDE 'LED'
ANNUNCIATOR AND TEST SWITCH. (TYPICAL)
J OCCUPANCY SENSOR SENSOR— SWITCH
MANUAL —ON (SEMI —AUTO) (TYPICAL)
�! LOW VOLTAGE OCCUPANCY SENSOR CEILING MOUNTED
SENSOR— SWITCH. (TYPICAL)
OCCUPANCY SENSOR POWER —PACK SENSOR— SWITCH.
(TYPICAL)
1
1
C
aI�
18
V—)
We' *400OfflftKIM
SCALE: 3/16" = l'-O"
I Ems
101C
00601
AT
K
1
1 101E I
■
s�
ICJ
�.
.a.
L
10 7
A.F
I. s> Ellff '.'E s Gam �i - " ltmil "7 "o -�tmfg MTV
ON -SITE CODE,'
&...
:i
r
�a
wm
Eli _ o
C,_
rA = r..^,,, ®o O w a y
Zo�w
tad - Z
LLJ cz; a w W
zzFvw
-c 4° Z�
zcQ`Z�
'=w2 Q
7 50
.°.3
�_ rJ
y
�'0♦ wxw(nZw
®w °iQz
�3 S Y� - —wtJ
g'Zwz QZ
V] w J 2' z
z F
b Q� ®F'6�/k
Q
�wuJ�wo
Sw'UO
'^ ira
`- m�a -'
0 � F-SQe ICJ
M
I®
SEAL:
/z/
p °r No. 01
a
®
a
a
4
S4Rad
T OF FaF
,
• Z
Z
r(
0�a
4co
� W
o
pq
ON
u�
o
�-0!� +
o
rn
P--4
0
coo
4.)0 q
Tnm
on
E4
x
�a
1--1
0
eN
DATE
PERMIT SET
04/22/14
SHEET NO.
E -2.0