13-748R-003IRREGULAR AREAS: ODD CURVES
N T.S
ELEC, ..............
(in pla:
GATE
(same
VACUi
(as sp,
WATE
SIN
ROVED CONTROL WIRE
11C CONTROLLER
IK II IN SENSOR
(install where rainfall is unrestricted)
- CONNECTION TO METER DETAIL
N.T.S
HMCIC
FINISH
P.V.C.1
Techline CENTER FEED LAYOUT
NT S
TYPICAL SOLENOID VALVE ASSEMBLY
N T.S.
LINE FLUSHING VALVE
PLUMBED TO PVC OR POLY
AREA PERIMETER
Techline LATERAL
TUBING
Techline START
CONNECTION
MALE ADAPTER
EXHAUST HEADER
Techline TEE
BLANK TUBING CENTERED
ON MOUND OR BERM
AIR/VACUUM RELIEF
VALVE (PLUMBED TO
Techline AT EACH
HIGH POINT)
SUPPLY HEADER
ZEMOTE CONTROL
/ALVE WITH DISC
v .:ILTER AND PRV
IRREGULAR AREAS: TRIANGULAR
NTS
PVC PIPING 12" x 18"
2" DISC
1 "SCH 80
Lr
(TYP) VALVE BOX
FILTER
UNION
LINE FLUSHING VALVE
PVC sleeves shall be Schedule
40 PVC (sized 2 sizes larger than the
Techline TEE SEE SPECS
'
_ _ _
RAINBIRD XF Series Drippedine
PLUMBED TO PVC OR POLY
LINE FLUSHING VALVE PLUMBED TO PVC
O
AirNaccum Relief Valves Kit (3/4" Air relief valve/
II
ARRANGE
Commercial High Flow Control Zone Kit
SEESPECS
' . FILTER FOR
1 CU FT PEA
DISASSEMBLY
GRAVEL SUMP
Techline START
LF AREA PERIMETER
Schedule 40 PVC
TUBING
ACCESS
(controller to be installed on wall
CONNECTION
I
MINI -Clik II Rain Sensor
Techline 3/4" ,
(locate in area of free rainfall)
RAINBIRD 2000 -PESP 2" Electromechanical
MALE ADAPTER 1"
Solenoid Control Valve
'
PVC TEE (SxSxT)
�
PVC PIPING � •
FINISH GRADE
Techline START CONNECTION
BRICK SUPPORT
(1 -EA CORNER)
PVC OR POLY EXHAUST HEADER
EXHAUST HEADER
VALVE BOX ,
SEE SPECS f SEE
(
Techline TEE
PVC OR POLY SUPPLY HEADER SPECS '
LINE FLUSHING
TechLine LATERAL TUBING I
VALVE TL050MFV -1
Techline START
I
AIRNACUUM RELIEF VALVE
CONNECTION ,
(PLUMBED TO Techline
SEE DETAIL 4 OF 4
ONE AT EACH HIGH POINT)
I
PVC REDUCER PVC LATERAL
ADAPTER (OR EXHAUST HEADER)
BLANK TUBING CENTERED
REMOTE CONTROL S X 1/2" FPT ,
O (SIZE AS REO'D)
ON MOUND OR BERM
VALVE WITH DISC
I
FILTER AND PRV
BRICK SUPPORTS
(THREE) '
AREA PERIMETER
I
IC MP
AR
(1 CUBIC FOOT)
BLANK Techhne TUBING M-61I
(CENTERED ON MOUND OR BERM) ddtWYdd�J1JJ
(CE
AR
Techline TUBING LATERAL '
SUPPLY HEADER I
-AIRNACUUM RELIEF
VALVE
REMOTE CONTROL VALVE WITH
DISC FILTER AND PRV
Techline LINE FLUSHING VALVE
PERIMETER LATERALS
I F
2" TO 4" FROM EDGE NTS
IRREGULAR AREAS: ODD CURVES
N T.S
ELEC, ..............
(in pla:
GATE
(same
VACUi
(as sp,
WATE
SIN
ROVED CONTROL WIRE
11C CONTROLLER
IK II IN SENSOR
(install where rainfall is unrestricted)
- CONNECTION TO METER DETAIL
N.T.S
HMCIC
FINISH
P.V.C.1
Techline CENTER FEED LAYOUT
NT S
TYPICAL SOLENOID VALVE ASSEMBLY
N T.S.
LINE FLUSHING VALVE
PLUMBED TO PVC OR POLY
AREA PERIMETER
Techline LATERAL
TUBING
Techline START
CONNECTION
MALE ADAPTER
EXHAUST HEADER
Techline TEE
BLANK TUBING CENTERED
ON MOUND OR BERM
AIR/VACUUM RELIEF
VALVE (PLUMBED TO
Techline AT EACH
HIGH POINT)
SUPPLY HEADER
ZEMOTE CONTROL
/ALVE WITH DISC
v .:ILTER AND PRV
IRREGULAR AREAS: TRIANGULAR
NTS
PVC PIPING 12" x 18"
2" DISC
1 "SCH 80
(TYP) VALVE BOX
FILTER
UNION
FINISH GRADE
PVC sleeves shall be Schedule
40 PVC (sized 2 sizes larger than the
Techline TEE SEE SPECS
'
_ _ _
RAINBIRD XF Series Drippedine
Techline TUBING
X F D- 09 -12- 500/250/100
O
AirNaccum Relief Valves Kit (3/4" Air relief valve/
II
ARRANGE
Commercial High Flow Control Zone Kit
SEESPECS
' . FILTER FOR
1 CU FT PEA
DISASSEMBLY
GRAVEL SUMP
BLANK Techline
& MAINTENANCE
Schedule 40 PVC
TUBING
ACCESS
(controller to be installed on wall
in domestic pump room)
MINI -Clik II Rain Sensor
Techline 3/4" ,
(locate in area of free rainfall)
RAINBIRD 2000 -PESP 2" Electromechanical
MALE ADAPTER
Solenoid Control Valve
'
PVC TEE (SxSxT)
�
PVC PIPING � •
BRICK SUPPORT
(1 -EA CORNER)
2" DISC FILTER Techline START CONNECTION
N T.S N T S.
REMOTE CONTROL
VALVE WITH DISC
FILTER AND PRV
PVC OR POLY SUPPLY HEADER
Techline START
CONNECTION
MALE ADAPTER
Techline TUBING LATERAL
AREA PERIMETER
AIR/VACUUM RELIEF
VALVE (PLUMBED TO
Techline AT EACH
HIGH POINT
BLANK Techline TUBING
(CENTERED ON MOUND OR
BERM)
PVC OR POLY EXHAUST HEADER
PERIMETER LATERALS
2" TO 4" FROM EDGE
PLUMBED TO PVC OR POLY
LINE FLUSHING VALVE
Techline "END FEED" LAYOUT
Techline END FEED LAYOUT
NTS
FINISH GRAf'�
6" ROUND
VALVE BOX
AIR / V
RELIEF
112" PVC COUI
(TXT)
1/2" SCH 80 RI:
(LENGTH AS R
BRICK SUPPC
(THREE)
3/4" CRUSHEr
GRAVELSUM.
PVC PIPING
AND FITTINGS
Techline AIRNACUUM RELIEF
NTS
IRRIGATION MATERIALS LIST
KEY
ITEM
PVC laterals & mains shall be schedule
O
W
40 PVC (sized as shown on plans)
—
PVC sleeves shall be Schedule
40 PVC (sized 2 sizes larger than the
pipe running through it)
_ _ _
RAINBIRD XF Series Drippedine
X F D- 09 -12- 500/250/100
AirNaccum Relief Valves Kit (3/4" Air relief valve/
(0
Easy Fit Compression Tee/ and Flush Cap)
Commercial High Flow Control Zone Kit
(XCZ- 150 -COM) (15-40 gpm)
(1 1/2" PESB Valve /1" Basket Filters x2/ 40psi
Pressure Regulators x2)
Galvanized Tie -Down Stakes (For Drippedine)
�dTV
PVC Supply Hearder for dripplerline
Schedule 40 PVC
RAINBIRD RC- Series multi- station Controller
(controller to be installed on wall
in domestic pump room)
MINI -Clik II Rain Sensor
(locate in area of free rainfall)
RAINBIRD 2000 -PESP 2" Electromechanical
Solenoid Control Valve
.... . ;..
Irrigation Control Wire
GENERAL NOTES:
1. SCOPE OF WORK: The Contractor shall furnish all labor,
machinery, tools, supplies, and equipment as necessary to construct
and provide an operating system, as indicated in the Plans. ThN ;
work shall include, but not be limited to, furnishing materials (pipe,
valves, sprinkler heads, fittings, controllers, electrical, wire and
fittings, primer, glue, etc.), layout, protection to the public,
excavation, assembly, installation, backfilling, compaction, repair of
road or pavement surfaces, controller and low voltage feed to the
valves, clean -up, maintenance and guarantee, and as -built plans.
2. Contractor shall coordinate with General Contractor or other
pertinent Contractors on the job to insure that sleeves are provided
and installed under hard surfaces to allow access to all areas to be
irrigated. All sleeves shall be constructed of Schedule 40 PVC.
Bury all sleeves a minimum of 24" below the surface. Sleeve to be 2
times the size if the pipe running through it. Sleeve shall extend 24"
past the edge of pavement into the area to be irrigated.
3. GUARANTEE: The irrigation system shall be guaranteed for a
minimum of one calendar year from the time of final acceptance.
4. REPAIR UTILITIES: The Contractor shall be responsible to verify
the location of all utilities by hand excavation or other appropriate
measures before performing any work that may result in damage to
utilities structures, or property. The Contractor shall take immediate
steps to repair, replace, or restore all services to any utilities which
are disrupted due to his operations. All costs involved in disruption
of service and repairs due to negligence on part of the Contractor
shall be his responsibility.
5. AS -BUILT DRAWINGS: Prints of the plans will be supplied to the
Contractor for recording "as- built" information. Immediately upon
installation of any work which deviates from what is shown on the
Plans, the Contractor shall clearly indicate such changes in red
pencil on the prints. Such changes shall include, but not be limited
to, changes in (1) materials; (2) sizes of material; (3) location; and
(4) quantities.
6. The entire installation shall fully comply with all applicable local
and state codes and ordinances. The Contractor shall take out all
required plumbing and electrical applications and permits, arrange
for all necessary inspections and shall pay all fees and expenses in
connection with same as part of work under the contract.
7. UNIT PRICES: The successful bidder shall furnish, to the Owner,
a unit price breakdown for all materials. The Owner may at his own
discretion, add to or delete from the materials, using the unit price
breakdown submitted to and accepted by the Owner.
8. MAINTENANCE PERIOD: The irrigation system shall be
maintained for a period of 90 days after final acceptance of
installation. Maintenance shall include checking of the system 2
times per week. Contractor shall be responsible to replace/repair
any broken or malfunctioning parts of the system including those
damaged by accidents or vandalism. Repairs shall be made
immediately at the time of inspection or when notified by the
Landscape Architect.
9. The irrigation system shall provide 100% coverage with a
QTY minimum of 100% overlap of water spray.
as required
10. The system is design to provide sprinkler precipitation rates that
are nearly equal in each zone. Mixing of sprinklers with widely
as required varying precipitation rates in a zone will not be accepted.
11. All pipe shall be made of Schedule 40 PVC, except flexible PVC
as required (or Toro funny pipe) for flexible swing joint and Schedule 80
;el pipe for all above ground fittings. Pipe locations
ted in the field. When laying out mains and laterals,
ar edges of pavement or against buildings wherever
low space for plant rootballs. Coordinate pipe
plantings. Bury all mains 18" below surface and
)epth shall be measured to top of pipe.
up sprinkler heads a minimum of 8" from edges of
I curbing, and heads on risers a minimum of 18 ", or as
e pans.
located in shrub or groundcover beds shall be installed
liar details in the plans. All other heads shall be
swing joint as per details in the plans.
ation control wire in conduit in the same trench as
ter the main. ASI wire shall be #14 or larger solid
proved underground direct burial cable and shall be
th no splices from controller to solenoid valve.
tions are schematic and shall be adjusted in the field.
all be in a separate valve box (10" x 16 ") min.). When
boxes in grass or groundcover areas, set boxes a
?" apart to allow grass or groundcover to grow between
)ossible, hide valve boxes in shrub beds, a minimum
ge of beds. Set all valve boxes, concrete or plastic, in
ever flush with finish grade, and level, with a minimum
•avel at the bottom of the box, with at least 2" of
n the bottom of the valve to the top of the gravel.
Notify the Landscape Architect in writing when testing
:ted. Conduct test in the presence of the Landscape
ar all PVC assembly is completed the lines shall be
are that no rocks, sand, or other foreign debris remains
'he mains shall be filled with water and all outlets shall
9 plugged. The main shall be pressurized to 100 PSI
I of one hour. No section of the main will be approved
drops more than 5 PSI at the end of the one hour
shall be repaired immediately and the system shall be
found satisfactory by the Landscape Architect.
IRRIGATION PLAN (on top of garage and streetscape)
SCALE: 1/16" = 1' -0"
NORTH
�1
1767n W 78th Ave., -Suite E14
MIAMI, FLORIDA 33015
PHONE. 305 - 392 -1016
'-V,5 IL: Info &osenberagardner.com
- (,ORPURATE #: LC0000236
- -- LLt �-
F-
0
W
I—
U
"~
OU
Q Z }F
W Z w=
n- Z U
Q Q oa
U J U) Lu
U) aa
I� wUVi
Z Z 2 UJI
Q Q W¢�
1 Uv
(�ryZ
�WCD
LIJ Z
��
M
W
WQ�
O�
0�
J
LL
L1
Q
U
O
W
�O
J
�V
V
Q
LU
LLI
0
(0
L 3:
G CD
41
N
a)
Z C/)
C: CU
(u -45
0- 0
C: -0
O C
CU
CU
•L
L
`,c
J
Bill Rosenberg
Ken Gardner FL I b T569 -
DATE
11.30.12
REVISIONS
04.01.13
05.29.13
07.03.13
10.21.13
02.13.14
09.26.14
SCALE
1/1611 = 11 -011
SHEET LA -3
�lie *+rra
�M.
a+�l
r
„ ,y.True
a '
,,.*Co -
r
.�e
CV
N
,0-
�, V
d
-..2_�_ 6" PEA GRAVEL
ell