12-780-0111. THE PROJECT IS "REMODELING ". THE CONTRACTOR SHALL VISIT THE JOB SITE TO DETERMINE THE EXTENT OF WORK INVOLVED WITH THESE DOCUMENTS AS SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND ALLOW FOR ANY CHANGES THAT MAY BE MADE DURING THE COMPLETION OF THE JOB. ANY ELECTRICAL WORK THAT MAY HAVE TO BE DONE TO COMPLETE ANY ALTERATIONS SHOWN ON ANY PLAN SHALL BE INCLUDE IN THIS CONTRACT WITH NO ADDITIONAL CHARGES TO THE OWNER AFTER THE CONTRACTS ARE LET. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE ELECTRICAL CODE (N.E.C.), AND ALL OTHER CODES AND ORDINANCES IN EFFECT AT THIS LOCATION. 3. THE CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS AND EQUIPMENT REQUIRED FOR A COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS 4. CONTRACTOR SHALL REVIEW AND UNDERSTAND THE CONTENT OF THESE DRAWINGS, VISIT THE SITE AND THOROUGHLY REVIEW EXISTING CONDITIONS PRIOR TO BID. NO ALLOWANCE WILL BE MADE FOR ANY EXISTING CONDITION THE CONTRACTOR DID NOT BECOME AWARE OF OR UNDERSTOOD. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL COMPONENTS, INCLUDING REQUIRED CONNECTORS, FITTINGS, LUGS, CONTACTORS AND OTHER HARDWARE REQUIRED TO MAKE THE SYSTEM OPERATIONAL. THIS ALSO INCLUDES THE COORDINATION OF RECEPTACLES TO EQUIPMENT PLUGS AND CONNECTORS. 6. REQUEST FOR SUBSTITUTION OF SPECIFIED EQUIPMENT, COMPONENTS AND MATERIALS SHALL BE APPROVED BY THE ARCHITECT AND THE ENGINEER OF RECORD AT LEAST TEN (10) DAYS PRIOR TO BID. 7. THE ELECTRICAL CONTRACTOR SHALL INSURE THAT ALL DRAWINGS REQUIREMENTS ARE MET AND NO CHANGES ARE MADE WITHOUT THE PREVIOUS APPROVAL OF THE ARCHITECT AND ELECTRICAL ENGINEER OF RECORD; AND THE PROPER APPLICABLE AUTHORITIES. 8. THE ARCHITECT AND ELECTRICAL ENGINEER OF RECORD SHALL BE N011FIED OF ANY CONDITION NOT CONSISTENT WITH THE ELECTRICAL DEFINITION PROVIDED, CURRENT NEC EDITION, OR APPLICABLE BUILDING CODES; WHICH WILL NOT BE REMEDIED AS A RESULT OF THIS WORK. 9. THE ELECTRICAL CONTRACTOR SHALL OBTAIN THE NECESSARY PERMITS, COORDINATE THE NECESSARY INSPECTIONS, AND COORDINATE WITH THE APPLICABLE UTILITY COMPANIES, THE IMPLEMENTATION OF THIS WORK. 10. ELECTRICAL DRAWINGS ARE NOT TO SCALE. THE CONTRACTOR SHALL REFER TO ARCHI- TECTURAL, CEILING GRID AND OTHER DRAWINGS FOR EXACT LOCATION OF EQUIPMENT, FIXTURES OUTLETS, SWITCHES AND OTHER ELECTRICAL COMPONENTS AND CONFIRM WITH ARCHITECT PRIOR TO START WORK. ANY POTENTIAL CONFLICT WITH OTHER EQUIPMENT, COMPONENT, OR STRUCTURAL MEMBER MUST BE REFERRED TO THE ARCHITECT PRIOR TO START IMPLEMENTING THIS WORK. 11: EXCEPT AS OTHERWISE INDICATED, ALL CONDUCTORS SHALL BE COPPER. USE TYPE THWN STRANDED CABLE FOR CONDUCTORS IN THE SIZES No 8 AND LARGE. PROVIDE COLOR CODING PER N.E.C. FOR 120/240 VOLT SYSTEMS. CABLE SIZES No 3/0 AND LARGER SHALL BE TERMINATED WITH PRESSURE CRIMP CONNECTORS. USE FLEXIBLE METAL CONDUIT FOR CONNECTION TO LIGHT FIXTURES AND TRANSFORMERS. USE LIQUID TIGHT CONNECTIONS IN DAMP OR WET LOCATIONS. 12. ALL CONDUCTORS SHALL BE COPPER WITH THW /THWN INSULATION FOR SIZE #10 AND SMALLER. CONDUCTORS LARGER THAN #10 SHALL HAVE THW /THWN INSULATION. ALL CONDUCTORS #10 AND SMALLER MAY BE SOLID. ALL CONDUCTORS #8 AND LARGER SHALL BE STRANDED TYPE. 13. ALL MATERIALS SHALL BE NEW AND SHALL BEAR THE UL LABEL WHEN APPLICABLE 14. ALL ELECTRICAL COMPONENTS INSTALLED IN THIS WORK SHALL BE NEW, UNLESS NOTED OTHERWISE. AS APPLICABLE, ALL COMPONENTS SHALL BEAR THE APPROPRIATE LABELS LISTING AND MARKINGS. 15. ALL CONDUCTORS SHALL BE IN CONDUIT. ALL SECTIONS OF METALLIC CONDUIT SYSTEM SHALL BE GROUNDED AND ELECTRICALLY CONTINUOUS. USE ELECTRICAL METALLIC TUBING ( EMT ) FOR INTERIOR CONCEALED WIRING. 16. PANEL BOARDS ARE CIRCUIT BREAKER TYPE. VERIFY NUMBER AND SIZES OF BREAKERS AVAILABLE TO PERFORM THIS INSTALLATION. CONTRACTOR SHALL VERIFY ACTUAL DISCONNECT AND LOAD REQUIREMENTS OF ALL THE EQUIPMENT PRIOR TO INSTALLATION AND REPORT TO ARCHITECT AND ENGINEER OF ANY DISCREPANCY. 17. AH CIRCUITS SHALL BE CLEARLY IDENTIFIED AND SHOWN ON PANEL DIRECTORIES. CONTRACTOR SHALL IDENTIFY FEEDERS, • BOXES AND OUTLETS AND PROVIDE A TYPEWRITTEN DIRECTORY IN EACH PANEL BOARD. CONTRACTOR MAY CHANGE CIRCUIT ARRANGEMENT SHOWN ON DRAWINGS. SHOWN 19. CIRCUITS ON # DETERMINE LOAD DATA AND PANEL CONTRACTOR SHALL PROVIDE r ROUTING OF # i TO SUIT JOB CONDITIONS, AND BALANCE THE JOB THROUGH-OUT 20. ALL WRING DEVICES SHALL BE i HUBBEL OR APPROVED EQUAL WRING DEVICES PLATES IN FINISHED AREAS SHALL BE AS PER OWNER'S RECOMMENDATION. 21. CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEM FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENTS OF THE FIXTURE. COORDINATE REQUIREMENTS WITH ARCHITECT. 22. PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 23. PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 24. FURNISH AND INSTALL LIGHTING FIXTURES AND LAMPS AS CALLED FOR ON PLANS. 25. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250 OF THE NEC. ALL RACEWAYS TO HAVE EQUIPMENT GROUND CONDUCTORS, AND WHEN CROSSING BUILDING EXPANSION JOINTS, EXPANSION FITTINGS WITH BONDING JUMPERS SHALL BE USED. 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING ASSOCIATED WITH HIS /HER INSTALLATION. CONTRACTOR SHALL DO HIS OWN CUTTING OF FLOORS WHEN REQUIRED AND GENERAL CONTRACTOR WILL DO ALL PATCHING. OBTAIN APPROVAL OF GENERAL CONTRACTOR BEFORE DOING ANY CUTTING. REPAIR ANY DAMAGE DONE TO OTHER EQUIPMENT OF MATERIAL. 27. COORDINATE ALL BOX LOCATION WITH BUILDING ARCHITECTURAL FEATURES. 28. CONTRACTOR SHALL INSTALL ALL REQUIRED CONDUCTORS TO THE APPROPRIATE SERVICE TIE -IN POINTS. 29. ALL MOUNTING HARDWARE SHALL BE BY ELECTRICAL CONTRACTOR. 30. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES EQUIPMENT INSTALLATION REQUI- REMENTS AND PROVIDE ALL NECESSARY CONNECTIONS, WRING AND INSTALLATION OF REQUIRED MOTOR STARTERS, EQUIPMENT CONTROLS AND SPECIAL PLUGS AND WIRING. 31. CONTRACTOR SHALL PROVIDE 6 SETS OF SHOP DRAWINGS SUBMITTAL FOR ALL MATERIAL AND EQUIPMENT TO BE USED FOR APPROVAL BY THE ARCHITECT AND ENGINEER OF RECORD. 32. ALL EQUIPMENT INSTALLATIONS, AND INTERFACE WITH OTHER SYSTEM AND CONTROLS, SHALL BE PERFORMED IN ACCORDANCE WITH EQUIPMENT MANUFACTURER'S SPECIFICA- TIONS, THE REQUIREMENTS OF THESE DRAWINGS, THE LATEST NEC EDITION AND APPLICABLE LOCAL CODES. THIS INCLUDES APPLICABLE GROUNDING AND BONDING OF METAL PARTS. 33. CONTRACTOR SHALL MAINTAIN A SET OF REPRODUCIBLE DRAWINGS SHOWING AS BUILT CONDITIONS AS THEY OCCUR. A COMPLETE SET OF AS -BUILT REPRODUCIBLE DRAWINGS SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ARCHITECT AND ENGINEER OF RECORD PRIOR TO FINAL ACCEPTANCE OF INSTALLATION. THESE DRAWINGS SHALL HAVE ALL INSTALLATIONS REFERENCED BY DIMENSIONS TO A SET OF REFERENCE POINT OR POINTS. 34. CONTRACTOR SHALL FURNISH THE OWNER WITH ALL OPERATING MANUALS AND MAINTE- NANCE INSTRUCTIONS FOR EQUIPMENT INSTALLED. MANUALS SHALL BE BOUNDED IN THREE RING LOOSE LEAVE BINDERS AND INDEX BY PRODUCT TYPE, ALSO A SECTION WITHIN THE MANUAL SHALL BE INDEXED WITH NAME, TELEPHONE NUMBER AND ADDRESS OF ALL LOCAL SUPPLIERS OF ALL MATERIAL AND EQUIPMENT INSTALLED TOGETHER WITH NAME, TELEPHONE AND ADDRESS OF ALL CONTRACTORS OF THE PROJECT. PROVIDE 3 SETS TO BE APPROVED BY ENGINEER OF RECORD. 35. THE ELECTRICAL CONTRACTOR SHALL INSURE THAT WORK IS PERFORMED BY PROPERLY CERTIFIED AND LICENSE PERSONNEL; OR UNDER IMMEDIATE DIRECT SUPERVISION, IF APPLICABLE. 36. CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM THE DEFECTIVE WORKMANSHIP AND MATERIALS, USUAL WEAR EXPECTED, AND SHOULD ANY SUCH DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY THE OWNER. SUCH CONTRACTOR SHALL REPAIR AND /OR REPLACE ANY DEFECTIVE ITEMS AND ALL DAMAGE RESULTING FROM SUCH FAILURE, AT NO EXPENSE WHAT SO EVER TO THE OWNER. 37. "ELECTRICAL INSTALLATIONS" SHALL CONFORM TO REQUIREMENTS OF N.E.C.110 -26 (a) "CLEARANCES" AND N.E.C.408 -18 "DEDICATED SPACES" FOR SWITCHBOARDS AND PANEL BOARDS INCLUDING SPACES ABOVE THE EQUIPMENT. 38. "PRIOR TO INSTALLATION OF ROUGH ELECTRIC WIRING" CHECK NAMEPLATE DATA OF A/C EQUIPMENT AND OTHER EQUIPMENT TO OBTAIN CORRECT WIRE SIZES AND OVERCURRENT PROTECTION AT NO COST TO OWNER. 39. INTERRUPTING CAPACITY RATING OF ELECTRICAL SYSTEMS AND SERVICE EQUIPMENT SHALL CONFORM AS SET FORTH IN N.E.C. ARTICLES 110 -9. 40. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING HIS BID IN ORDER THAT HE MAY BECOME AWARE OF EXISTING CONDITIONS. NO ALLOWANCES WILL BE MADE FOR ANY EXISTING CONDITION OF WHICH THIS CONTRACTOR WAS NOT AWARE. 41. ELECTRONIC FILES - SUBMITTAL PROCEDURES: A. GENERAL: IF REQUESTED BY OWNER OR CONTRACTOR, ELECTRONIC COPIES OF CAD FILES OF THE CONTRACT DRAWINGS WILL BE PROVIDED BY ENGINEER FOR CONTRACTOR'S USE IN PREPARING SUBMITTALS. A STIPULATED SUM WILL BE CHARGED TO THE REQUESTING PARTY FOR THIS SERVICE. B. THE FOLLOWING CHARGES WILL APPLY FOR PROVIDING ELECTRONIC FILES: 1. $50.00 PER ELECTRONIC DRAWING FILE PREPARED 2. $350.00 PER ORDER FOR ADMINISTRATIVE PROCESS. SINGLE POLE LIGHT SWITCH, QUIET TYPE, 120 VOLTS, 20 AMPS �3 3 WAY LIGHT SWITCH, QUIET TYPE, 120 VOLTS, 20 AMPS 6 RECEPTACLE OUTLET. INSTALL 18" A.F.F. UNLESS OTHERWISE INDICATED EXHAUST FAN MOTOR A.F.F. ABOVE FINISHED FLOOR FITTING ROOM LGT PLAN EXISrM PANEL. 'I3' YOLTAGE:120 /208VOLTS MAIN: 200AMPS PHASE: 3 PHASES, 4 WIRES NEUTRAL: 200AMPS MOUNTING: SURFACE BREAKER SIZE: 200AMPS PHASES COND. WIRE DESC. LOAD POLES BR CKT A BICrKTI X L A C. WI ND. ii EXISTING SPARE 3 10C 1 x 1 1 2 EXISTING SPACE 3 xI 1 4 EXISTING SPACE 5 IxI 6 EXISTING SPACE =4 3-#6 EXISTING CU(*), 17280 3 60 7 x 1 8 20 1 1000 EXISTING FRON LIGH S 2-J12 1/2- 9 x 110 35 1 3200 NEW WATER HEATER 2-#8 3/4- 11 x 12 20 1 700 NEW LIGHTS 2 - 12 1 3- EXISTING AHU * 16163 3 60 13 x 14 20 1 1300 NEW LIGHTS 2- 12 1 2 E34 15 x 16 20 1 150 NEW LIGHTS 2-#12 1 2 17 x 18 0 1 300 EXISTING EXI IGH S -#12 1 2 2- 8 EXISTING FCU * 9152 2 50 19 x 20 21 x 22 3 4 3-#8 EXISTING CU(*) 10440 3 40 23 x 24 I 126E :4xl 1XI 128 EXISTING SPArF 29 1 IxI 30 ( *) NON CONCURRENT LOAD TOTAL DEMAND= 1.25 *(LIGHTS +HICHEST MOTOR +OTHERS 0100% =39553 VA =110 AMPS HEATI t t r a .t I i t t i E i i s i i i s i i i t t i i 4ATER -- M NOTES REED VEHIFY ALL DIMi SiONS t R16WTJiANSIRUCT10k 0 0 i REV DATE DESCRIPTION COPYRIGHT NOTICE THE USE OF THESE DESIGNS, DRAWINGS, SPECIFICATIONS, AND / OR CALCULATIONS ARE RESTRICTED TO THE ORIGINAL PURPOSE FOR WHICH THEY WERE PREPARED, PUBLICATION IS EXPRESSLY LIMITED TO SUCH USE. OWNERSHIP OF THESE DOCUMENTS AND ALL INFORMATION OR DESIGNS CONTAINED HEREIN REMAINS WITH AMERICAN APPAREL RETAIL, INC. REUSE OR OTHER PUBLICATION BY ANY METHOD IS PROHIBITED EXCEPT WITH THE WRITTEN PERMISSION OFAMERICAN APPAREL RETAIL, INC. THESE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE COPYRIGHT OF THE AMERICAN APPAREL RETAIL, INC. NO PART THEREOF SHALL BE REPRODUCED OR COPIED, WITHOUT THE PRIOR CONSENT OF AMERICAN APPAREL RETAIL INC. VISUAL CONTACT WITH THESE DOCUMENTS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. CONSULTANT SEAL /4' MANUEL E.LAUREDD, PE. STATE OF FLORIDA PE 012964 CONSULTANT ADDRESS LAUREDD ENGINEERING COMPANY MECHANICAL & ELECTRICALENGINEERS 1941 SW 18TH AVE. MIAMI, FLORIDA 33145 (305) 445 -9725 enaltt met2tec717.com American Apparel" LOCATION LV3 Premium Outlets ADDRESS 805 Grand Central Parkway Suite 1945 as Vegas, NV 89106 SCALE AS NOTED TITLE ELECTRICAL DRAWN BY MB 07/24/12 CHECKED BY MEL Alm r._.. .. ...... „,. ...�.. .,._. µ_ .. i . • 0 LL.• X Lo ii REV DATE DESCRIPTION COPYRIGHT NOTICE THE USE OF THESE DESIGNS, DRAWINGS, SPECIFICATIONS, AND / OR CALCULATIONS ARE RESTRICTED TO THE ORIGINAL PURPOSE FOR WHICH THEY WERE PREPARED, PUBLICATION IS EXPRESSLY LIMITED TO SUCH USE. OWNERSHIP OF THESE DOCUMENTS AND ALL INFORMATION OR DESIGNS CONTAINED HEREIN REMAINS WITH AMERICAN APPAREL RETAIL, INC. REUSE OR OTHER PUBLICATION BY ANY METHOD IS PROHIBITED EXCEPT WITH THE WRITTEN PERMISSION OFAMERICAN APPAREL RETAIL, INC. THESE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE COPYRIGHT OF THE AMERICAN APPAREL RETAIL, INC. NO PART THEREOF SHALL BE REPRODUCED OR COPIED, WITHOUT THE PRIOR CONSENT OF AMERICAN APPAREL RETAIL INC. VISUAL CONTACT WITH THESE DOCUMENTS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. CONSULTANT SEAL /4' MANUEL E.LAUREDD, PE. STATE OF FLORIDA PE 012964 CONSULTANT ADDRESS LAUREDD ENGINEERING COMPANY MECHANICAL & ELECTRICALENGINEERS 1941 SW 18TH AVE. MIAMI, FLORIDA 33145 (305) 445 -9725 enaltt met2tec717.com American Apparel" LOCATION LV3 Premium Outlets ADDRESS 805 Grand Central Parkway Suite 1945 as Vegas, NV 89106 SCALE AS NOTED TITLE ELECTRICAL DRAWN BY MB 07/24/12 CHECKED BY MEL Alm r._.. .. ...... „,. ...�.. .,._. µ_ ..