12-104-001
STEEL BAR JOIST --� AM CLAMP W1 LOCK NUT FOR 1" TO 4" PIPE kLL THREAD ROD FOR 1" TO 4" PIPE RING HANGER BAR JOIST HANGER DETAIL PIPE 1 TO 4" NOT TO SCALE IF DUCT OR MECHANICAL EQUIPMENT GREATER THAN 40' CREATES AN OBSTRUCTION TO SPRINKLER DISTRIBUTION THE OBSTRUCTION SHALL HAVE A SPRINKLER INSTALL BENEATH AS SHOWY BELOW d a a as 1' TO 12' SPRINKLER HEAD SEE HEAD LEGEND BRANCHLINE PIPING OBSTRUCTION 48' OR GREATER TO 6' 155 °F BRASS UPRIGHT OR EQUAL TO OVERHEAD SPRINKLER TEMP. 1' -0' MAX NOTE: WHERE SPRINKLERS ARE INSTALLED BELOW 7'- O'AF.F HEAD GUARDS HANGER AS REQUIRED SHALL BE INSTALLED P' A� r E QTY SPRINKLER HEAD LEGEND NEW SYM DESCRIPTION MANUR PART# REMARKS 2 ' /," 155° 5.6K BRASS UPRIGHTS - STANDARD RESPONSE Viking 1006 BRASS 2 SUBTOTAL 2 TOTAL SPRINKLERS ON DRAWING NEW SPRINKLERS INSTALLED WILL HAVE HEAD BOARDS 2 1 0 4 8 SCALE 1/411 =11 -011 FIRE PROTECTION NOTES: SCOPE OF WORK: MODIFY EXISTING FIRE SPRINKLER SYSTEM YO COMPLY 1 WITH FIRE MARSHALS COMMENTS -ADD ADDITIONAL FIRE- SPRINKLER PROTECTION UNDER DUCT WORK 6" OS &Y CONTROL VALVE WITH TAMPER SWITCH AND WATER FLOW SWITCH IS EXISTING AND IS TIED INTO FIRE ALARM COMPONENTS. ALL FIRE PROTECTION WORK DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13, 2002. FLORIDA BUILDING CODE, PROJECT SPECIFICATIONS AND THE AUTHORITY HAVING JURISDICTION. ALL HANGING METHODS TO CONFORM TO NFPA 13, 2002 STANDARDS. EXISTING PIPE & FITTINGS IN THIS AREA ARE THREADABLE THINWALL PIPE WITH CAST IRON SCREW FITTINGS. MATERIAL: PIES!' PIPING AND FITTINGS SHALL BE UL LISTED AND APPROVED 1" THREADEDABLE THINWALL (BLT) w! THREADED CAST IRON FITTINGS ES NEW SPRINKLER SPACING BASED ON OCCUPANCY LIGHT HAZARD 225 SQ.FT. MAXIMUM SPRINKLER SPACING ALL SPRINKLERS ARE STANDARD RESPONSE OWNER IS RESPONSIBLE FOR MAINTAINING 18" CLEARANCE FROM TOP OF STORAGE TO SPRINKLER DEFLECTORS ALL PIPE PENETRATING FIRE RATED WALL AND FLOOR ASSEMBLIES SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE MANUFACTURES REQUIRED MATERIALS AND METHOD SPECIFICATIONS. ADD ADDITIONAL SPRINKLERS OF THE SAME TYPE USED IN THIS RENOVATION TO THE EXISTING SPARE HEAD BOX SYMBOL LEGEND 0 o G O 0 0 0 KEY PLAN NOT TO SCALE 0 0 WATER FLOW TEST � o �O O 0 � o � EXISTING PIPING: NEW PIPE & FITTINGS =mow= DENOTES NEW HANGER 0 — NEW SPRINKLER • — EXISTING SPRINKLER TO REMAIN © — NEW SPRINKLER AREA OF' WORK INSPECTOR AS PER NFPA 13 2002 EDITION SECTION 18.2.1.6 MOPFICATIONS THAT CANNOT BE ISOLATED, SUCH AS RELOCATED DROPS SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE APPROVE[.' M M -DADE COUNTY FIRE DEPARTMENT BLDG. PERMIT FIRE ALARM_ FIRE SUPPRESSION WATER MAIN EXT._ DATE: l /d//1. 'l aV6 /I/ Iz% ADVANCED SYSTEMS, INC. FIRE PROTECTION CONTRACTOR 1415 SOUTH 30th AVENUE, HOLLYWOOD, FLORIDA PHONE: 954 - 921 -2224 FAX: 954- 921 -2348 EMAIL: info®asifire.com Fire Protection Winn Dixie #285 DATE 01118112 5850 SW 73rd Street ' I MARTINEZ `E 1141nah ■ 1 Foot South Miami, Fl a • 'J r' ' 4 a . µ P r� 4 � � 0 0