02-830-016I
L,
U
-j
LL
�i
�n
C7�
�I)
L
r
r)
If )
if)
i ->
1
Lo=1:
U
N
G
LC)
Lo
CJ
rJ
`,
Ci
RECESSE JUNCTI N_I3OX-
MOUNTED ® 5' -0' A.F.F <"
SEE NOT #26. PA
PM 10
P - )
M 12
1/ » )/ IN )
1
!N
PM -12
PM -10
'M -10 Lo
I CPA -8 I -1
EXISTING GUTTER
0 BECRELOCATEDES
-Tf...
ZL CL -38,40 �2'- 21 "F.F,W.
1 A7 A6 A9 8 �I - VERIFY IN FIEL
C A-
- /'� _.,`
-_
I U
� �••.•• u u uwwux.
j'
U65 1 0 D63 1„ _ 0 06j 8 J U65 12 -0 U83 12 -0 L63 1L -0 U63 „12 - 0 V5V34 70 -U V5V34 2' 11 °'12' -6° M4A3 i?' -0" 3 z' -21 12 " -0" M4A3 12' M4A3 8' -U" MM,3 8' Y -� - I " " " " ""
3' -3- 3' -3- 3' -3- _ I !
F. F. W. F. F. Vd. F.F.W.�-
F. F W.
- 12' 0 "AFF as' -oT„ 70, 1„ 12' 0 "AFF„ �4 ° _l ......................
z
F. .W.
46'-021" 11T -8 EX'IS,,,.,,..
92' -8' 1 2' -0' A F" 1 9� 10" _n. '1 1 3, �„
i T. ;
CC -B -1 CC -A -7 CC -A -6 CC -C -23 CC -A -9 CC-A-8-1 RPA -8 I,MDP
CL -15 ( IGHTS) CL--7 (LIGHTS) CL -6 (LIGHTS) CL -23 (LIGHTS) CL -9 (LIGHTS) CL -8 (LIGHTS
PH -15 (FANS) PH -7 (FANS) PH -6 (FANS) PH -23 (FANS)- PH -9 (FANS) PH -35(F. & HTRS.) 3 32 WID I NEW PNL ` 'NEW PNL
PH -35 (HTRS) PH -37 (HTRS) C-4 a ROOF L PB" p- "RPA'°
< E - - -..:: o CC -A--2 L "J
JNIEW PNL ;NEW PNL
��g���:� - r,..,. ( i_..- - CL -2 (LIGHTS - --
EXISTING BALRTZ7T0 I I'; ( ) LC kESER � RPB"
PMA -1 0 - RECONNECTED TO NEW - _ - -i -- P;H -2 FANS o. 1 U II i
ELECTRICAL FOR EXIST.
i B � CKT. ON PNL "PM :) -,� 9n btnsn - - - r - = PM -33
W GFI EM -1 I AHU BEING RELOCATED
OA/ II ROOF TO BE DISCONNECTED
(PM -16) /
Y I AND RECONNECTED BY
i
o >< ELECTRICAL CONTRACTOR.
? a° ::�
C, v o O O O o I NOTE:
I RECONNECT EXISTING
12 0 AFF l G l 12' -0 "AFF ;;GFI I LIFT TO NEW CKT, IN
PUSH BUTTON II
MOUNTED 6 ° -0" A.F.F C C -29 2 2 N COORpIN TE '•WP -- ANEL "PM . VERIFY
WPI ®= 11 PH 29 (F s l` FINAL LOCATIONS EIv1 -13 �ELD. WITH WINN DIXIEPA 5
EM 13 _ PH 13 (H R- / 2 (TYPICAL
l (ROOF)
I
(ROOF)
AP 9 W IKIU I IPM -26 %
G M - PM -3, P 17 - 1(ROOF) �IN
w w ' MDP -12 Cc -c -25 PM -1 W KS
I CC -B -1 z CL -25 (LIG T ) f�flOF:
o CL -16 (LI HTS _ 1,G o {, S "
w'
o PH -16 AN 1z 1 0 29' / PH -25 (FA °>".' ...... ..............r;':;......i;',;
� � I ( ) �i � '_ PH -40 (HT S) i I I I : w � �� z�
.3'- 2 F'F•W �Y I /_ M z �a RECESSED JUNCTION BOX
U� N_ t PM -3
J MOUNTED ®5' -0" A.F.F.
U T RECPT C E - P SEE NOTE #26.
Li
T 6 A.F.F. ABOVE BEER
I X STING COLUM S; OAFS�S (TYP. = I A4
12 0' AFFC C -28 jOB�E WRAP I H ) NEW AND EXISTING EXISTING
TO ENr+WL S 12' -o "A COOLER
- CL 28 (LIG S� E' ELECTRICAL PANELS I PRODUCE
O UIT. (TYPIC L
SEE RISE
H
i R SHT. E -602
... 28 FAN
1 CL -14 PH -4 FANS
O
I
I >n i CL -4 L GHTS I
I
N I
m
I
.. PRINKING
- r
CC A 4
-PMA 21
y FOUNTAIN
a o GFI
i
a o_� F 0 AL CASE
w P / V R FY REQUI'R M NTS __�_ L___.' CC
�-
o� - A S B I
D TU A _
U QC TION
3
CL 3 LIGHTS
-__� l 3 ( 2 W TH CASE S PH -33 (FANS) )
�N
PH -22 (HTRS)
o,/ r� o o O o 0 ° p I
7
CC -B -17 n l 000 CL -17 (LIGHTS) PM,_ ) FOOD F EEZER PM -8 / < _ _ U z 7' I 1 s' 2" P 17 F i -
H ALAS i - PM 28 FA I ( ° EM 13
939 LAW CC -C 30 j CC -C- PLN -21 5 PM -6
TI o CL -30 (LIGH ) / CL -26 ( &IG T) �PFI
EXISTI �+ GFI i o
PH -32 FANS U' I -PH -30 (FANS % i l PH -26 (FAL S 0' Fi RTU 2T Q - 0
° PH -14 (HTRS ( ( DP -11 0 0 J O
PH 42
CC -32 - - PM -14 ,
.......... ..... . 1
-� � � HTS
� if) � p
WP
I
_ (ROOF)' I I O _o�„ n l
,z' o° F ,
I
I
l L___J _.._.i _ -r - z o PM 17
- -- L
CC -C -27 EXISTING UNDER FLOOR O
CC -A -3 w
J PM -39 (HEATERS)1 DUCT JUNCTION BOX
GFI ';; • 1 CL -27 (LIGHTS) CL -3(LIG TS)
WP - PM -8 l I PH -27 (FANS) VERIFY LOCATION IN FIELD PH -3 (F S) 3 -
- I A
................••......,,,
• .: PH -39 (HTRS) b
B B ;` - O O
I� EXISTING UNDER FLOOR DUCT o ,� O
E v o O
MOUNTED AT .............. - ...........
o �... - ..
�O O�
o -- SYSTEM- COMMUNICATIONS ',•r.,
- - - L❑ cn CEILING CL- -39,41 I„ %-
� NO 120V POWER EXISTING CHECKSTA / ,
B- B ! CP,4 tO / 3-A -1 i
��% 3 -31 ` -, EXISTING EXHAUST \
TO REMAIN. TYPICF �� \ <� _ - -.% FAN TO BE REPLACED
CC B -18 J 12 ° -0 "AFF 12' -O "AFF \� CL IGHTS) _ WITH NEW RECONNECT
- CS,1 CS,2 CS,3 CS,4 CS,5 CS.6 CS,7�
1( S)
- - - - -- - - ` ' TO NEWTILIGHTSWITCAHND
I - - -n I I CATION IN /
PICA
2- 1 -C � I I
VERIFY D FIEL � PM -19
o ,e ns s ,o .a e Hess ( _. EF
I .f
O
ffffI -I I
I ' BACK R00 Lll�1 = EM -3 ' fi i �' D 3\
c H J
I �
PH -18 (FAN - -- - - - -.I N Al
TIME CLOCK COORD.� RT -3 I I
;..„
L :: - - -- - - - -- - -X S71NG UNDER FLOOR DUCT CO
f l W.
FINAL LOC ION _ - WP (R60F) WP I ..... ...,.. C B -7 O O�
DAIRY COOLER I r_ -- (ROOF) b YSTE'M'�'150WER'' PMA -26
i
Wllr�_W[N1�T DIXIE r I CPB -1 CPB -2 CPB- -3 CPB -4 CPB -5 CPB -6 cc -A- %
- - - -� - -� �` l i� PA -7 G = 00 O/ -42 Q ; - = -I --
18 �J u' I PMA -20 PMA -20 PMA -22 PMA -22 PMA -24 PMA -24 CPB -26 O CL -t2 B ITS O O �I -21
O i 1.
EM -16,18 CPB -1 1 PH -12 (FANS)) f :: PM
--
�_ EM -15 3�4 "C. T� 2s' -1," N:' HD
1 1/4"C WITH PULL T L. BKB 2' 32 "F.F.w
-I - - -- - i w i- - - -J STRING TO TELEPHONE /4'C 3/410 t2' -0 "AF
- P NEL CPB
I_ -. ,.-L.T., , .Tr , h., .,,�,,,.,•,.......,......,..,., r �n J ® PANEL IN MACHINE J AD J J AD
...,.,,,.,, 1 _�L.I,.,.....,,,,,...0......E rIL . ..... .................. _ nzfa
„• . ............... ... •,•, •,,, , ...................... .............,,,•,,, ,.,,.,,,, - -
O o
W � u
'- � � -- �� ._. _. ... -_.., �. .. ...........• iunuiliiiiliiiliiiii� iii
' 11ii
WP O `_ -- - \ 2 1 1 1 ❑ t_: GFI RUN WIRING WP 1
(2) 2» TO MDP I CONCEALED TO
DOOR OPERATOR :Ir;.;;;•;1;:,,:,,,.,
PMA -13 I NEW I IN DOOR HEADER
,
-I._,,...- . -.. L ...........-....rt..- .2..•r,-., .- , , ,,.,..,,.,,.••,..,,,,.,,,•_,,_ , , _. -�., = , .. .- ,�
- ,.,,,•,,,,,,..,,•„ „„„..,.,.,...,-.,.....
. .,..,,.,..,.,,,,,•.,,,.,,,.,,.. ,..... ...,•° „,.,,.,.,.,.,._ .
GFI AUTO DOOR OUTLET
VE CEILING CTY
P,) - -- ICI P-
MA -15,17 2
PMA -19
... ....• .. ............. ....... ...... ,... " ... ..............
LOCATED IN FTIC
J -BOX
-Q.•
O
MOUNTED
IN WALL V -4"A F
CONTINUE TO J. OX NEW UNDER FLOOR
IN ATTIC. DUCT JUNCTION J -
BOX (TYPICAL) - - - FLOOR I- L,A
SCALE 3 2" = V_0"
E -1 REMODELING NOTES
1. ALTERATIONS TO EXISTING WORK BEING OF SUCH NATURE THAT ALL
FACETS OF THE WORK BEING IMPOSSIBLE TO DETAIL AND SPECIFY, IT IS
THEREFORE THE RESP❑NSIBILTY OF THE CONTRACTOR TO CAREFULLY
EXAMINE THE BUILDING AND FAMILARIZE HIMSELF WITH THE
CONDITIONS AND RELATE THESE CONDITIONS TO THE SCOPE OF THE
PROPOSED WORK.
2. ALL DIMENSIONS ON THIS DRAWING ARE CUMULATIVE AND ARE TAKEN
FROM FINISHED FACE OF WALL, EXCEPT AS NOTED TO CL OF COLUMNS
3, CONTRACTOR SHALL FURNISH WINN -DIXIE WITH DRAWINGS INDICATING
ANY PROPOSED MODIFICATION TO ELECTRICAL SERVICE PRIOR TO
STARTING WORK,
4. CONTRACTOR SHALL CONSULT WITH WINN -DIXIE REGIONAL
SUPERINTENDENT BEFORE STARTING ANY WORK- CALL PETE ONORATI
AT (954)783 -2836
5, ANY ELECTRICAL WORK WHICH SHALL INTERFERE WITH WINN - DIXIE'S
NORMAL OPERATIOS SHALL BE DONE AFTER STORE HOURS.
6, ALL ELECTRICAL WORK SHALL CONFORM TO NATIONAL, STATE AND
LOCAL CODES,
7, WHEN TWO OR MORE REFRIG CASES ARE ON THE SAME CIRCUIT,
INTERCASE WIRING SHALT_ BE RUN IN CASE RUNWAY,
8. CONTRACTOR TO FIELD CONFIRM LOCATION AND USE OF CIRCUITS IN REVISED
PANELS, PROVIDE NEW TYPED DIRECTORIES IN REVISED PANELS, PR ❑VIDE
IDENTIFICATION ON ALL NEW DISCONNECT SWITCHES, CONTACTORS, ETC,
DYM❑ TYPE "STICK ON" LABELS ARE NOT ACCEPTABLE,
9. ALL DEVICES, EQUIPMENT, ETC, WHETHER SHOWN OR NOT ARE TO BE
LEFT PROPERLY CONNECTED ELECTRICALLY, UNLESS SPECIFICALLY
NOTED TO BE REMOVED,
10 ALL EXISTING STUB -UPS, OUTLETS AND CONDUIT, ETC , NOT TO BE RE -USED
AND EXPOSED SHALL BE REMOVED BY THE CONTRACTOR.
11, ALL NEW CIRCUITS SHALL BE CONNECTED TO EXISTING PANELS WHERE
POSSIBLE, IF A NEW PANEL IS REQUIRED, IT IS TO BE FURNISHED AND
INSTALLED BY THIS CONTRACTOR,
12, ALL CONDUCTORS SHALL BE RUN IN HEAVY WALL THREADED
GALVANIZED STEEL CONDUIT WITH TAPED THREAD JOINTS WHERE SAID
CONDUITS ARE RUN UNDERGROUND.
13, ALL CONTACT ❑RS SHALL BE ELECTRICALLY HELD,
14, GENERAL CONTRACTOR IS TO SAW CUT EXISTING FLOOR SLAB TO MAKE
TRENCHES AS REQUIRED. RUN NEW REFRIGERATI ❑N TUBING, PLUMBING
LINES AND ELECTRICAL CONDUIT IN THESE TRENCHES, THE GENERAL
CONTRACTOR IS TO COORDINATE ALL TRADES AND SEE THAT ALL WORK
IS PLACED INSIDE THOSE CUTS AND THEN RESPONSIBLE FOR REPAIRING ALL
CUTS, PREPARING CONCRETE TO RECEIVE NEW FLOOR FINISH
15. ALL WIRING FOR CIRCUITS TREMINATING 75' OR MORE FROM PANEL
SHALL BE SIZED NOT LESS THAN 410 AWG, THIS NOTE TAKES PRIORITY
OVER ANY SIZING SHOWN ON PANEL SCHEDULES,
16, ALL ELECTRICAL EQUIPMENT AND RECEPTACLES SHALL HAVE
GROUNDED TYPE SERVICES,
17. ALL CONDUIT RUN IN FLOOR SHALL BE 3/4" MIN,
18, ALL CONDUCTORS SHALL BE 98% CLIPPER,
19 ALL TELEPHONE RUNS IN SLAB MUST BE IN CONDUIT BY CONTRACTOR,
CONTRACTOR TO CHECK WITH LOCAL TELEPHONE COMPANY FOR
REQUIREMENTS.
20, ANY A/C WIRING TO BE DONE BY ELECTRICAL CONTRACTOR,
21, ALL CONDUCTORS FOR CASH REGISTERS AND COMPUTER CIRCUITS TO BE
STRANDED,
22 ALL CONDUCTORS ABOVE SIZE #6 SHALL BE THW,
23, THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS WITH THE DRAWINGS
BEFORE PROCEEDING WITH ANY WORK, IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO ESTABLISH DIMENSIONAL CONTROL LINES FOR THE
SUBCONTRACTORS TO CHECK THEIR LAYOUT WORK RELATIVE TO FUTURE WALLS AND
THE WORK OF OTHER SUBCONTRACTORS. THE CONTRACTOR SHALL REPORT ANY
PLAN CONFLICTS OR DISCREPANCIES TO ARCHITECT FOR CLARIFICATION. ANY
REMEDIAL WORK REQUIRED AS A RESULT ❑F NOT FOLLOWING THESE PROCEDURES
SHALL NOT ENTITLE THE CONTRACTOR OR SUBCONTRACTOR TO ANY ADDITIONAL
COMPENSATI ❑N.
24. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE REFRIGERATED CASE
MANUFACTURER TO VERIFY ALL ELECTRICAL REQUIREMENTS(SEE REFRIGERATI ❑N
SCHEDULE ON DWG E -605, VERIFY NUMBER OF CIRCUITS, WIRES, AND CONDUITS
PRI ❑R TO ANY INSTALLATION, ALL WORK REQUIRED TO COMPLETELY INSTALL ALL
CASES SHALL BE INCLUDED IN THE BASE BID, WHETHER OR NOT SUCH
REQUIREMENTS VARY FROM THOSE SHOWN IN THESE CONSTRUCTION
DOCUMENTS,
25, IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY ALL
CASE ROUGH -IN DIMENSIONS WITH THE CASE MANUFACTURER, CONTRACTOR
SHALL LAYOUT ALL ROUGH -INS FOR APPROVAL BY WINN -DIXIE
PRIOR TO ANY WORK. DIMENSIONS SHOWN MAY OR MAY
NOT BE ACCURATE FOR THE SPECIFIC CASES TO BE SUPPLIED ON
THIS PROJECT.
26. LOCATION FOR EXISTING ELECTRICAL STUB -UPS, J- BOXES, CONDUITS,
CIRCUITS, EQUIPMENT AND SWITCHGEAR ARE BASED UPON PARTIAL ORIGINAL
CONSTRUCTION DOCUMENTS SUPPLIED BY WINN - DIXIE. CONTRACTOR SHALL
REMOVED ANY DEVICES TO BE ABANDONED, WHETHER SHOWN ❑N DRAWINGS
OR NOT, TO ABOVE CEILINGS OR INSIDE WALLS, CONTRACTOR SHALL MODIFY
LAYOUT AS REQUIRED DUE TO ANY ENCOUNTERED DEVIATIONS, TO PROVIDE
COMPLETE WIRING, CONDUITS, ROUGH -IN AND HOOK- --UP OF ALL EQUIPMENT
AND DEVICES, AT NO ADDITIONAL COSTS TO WINN - DIXIE,
27, CIRCUITS "PH" AND "CC" FOR COOLERS /FREEZERS SHALL BE RUN OVERHEAD,
UNLESS OTHERWISE NOTED, AFTER EQUIPMENT IS SET IN PLACE.
28, CONTRACTOR TO FURNISH AND INSTALL CORDS ON ALL APPLIANCES TYPE
FIXTURES WHEN CORDS ARE NOT FURNISHED WITH THE FIXTURES,
29, DIMENSIONS INDICATED FROM REAR SALES AREA PARTITI ❑N WALL ARE TAKEN
FROM FINISHED FACE OF WALL ON SALES AREA SIDE.
30. NOT USED
31, RECEPTACLES AND OUTLETS IN MEAT CUTTING ROOM, DELICATESSEN /BAKERY,
BAKERY PREP, SERVICE MEATS, AND SEAFOOD PREP AREAS SHALL BE MOUNTED
+42" A,F,F AND SHALL HAVE STAINLESS STEEL COVERS AND
GROUND FAULT PROTECTION
32. SEE STUB -UP DETAILS AND CONNECTION REQUIREMENTS FOR CASES ON
DETAIL SHEET,
33, MEAT CUTTING ROOM, DELICATESSEN, BAKERY, SEAFOOD, PRODUCE,
AND SERVICE MEAT AREA SCALES SHALL HAVE ENGRAVED COVER PLATES
ON SCALE RECPTACLES READING "SCALES ONLY
EXISTING EXHAUST
I FAN TO BE REPLACED
�(� EF (� WITH NEW RECONNECT
•••.•. • • TO EXISTING CKTS, AND
r.... ? TO NEW LIGHT SWITCH. _
P
EXISTING
PAYPHONES
«..... nr>)• • .............................TO REMAIN
0
c0
N
W
EXISTING - P
WATER HEATER NEW EMERGENCY GENERATOR 60 KW
TO REMAIN 120/208V, 30, 4W.
MANUF. BY: ONAN MODEL 60ENA 60HZ
EM -19 OR EQUAL MUST BE APPROVED BY "W.D." d
GFI GFI PROVIDE REQUIRED TRANSFER SWITCH AND
ALL ASSOCIATED HARDWARE REQUIRED, AS r r� O
NEW -PM- RECOMMENDED BY MANUFACTURER. dddl r
AUTOMATIC CO I-
TRANSFER O W O
S
W
SWIT
CHE WP � O O
COMPRESSOR A � �
PM -2 MDP -1
GFI r I
Q 00
LO
Lo
PACKAGE
COMPRESSOR "E" N
LJ
RPA -2
WP O U v In
O
® O z
l o
J
WP C) COMPRESSOR T" PACKAGE
' " F
" I � Q -�
.RPA -7 -
� W
Ln ♦-
EXISTING l: SE
A� �f
EXISTING MEZZANINE MACHINE ROOM
SCALE 3/32" = 1'-0" `b4.
{,
ENGINEERS
_ 00
N (\J .-
r___) w
�v
W a w
Lam. w O
J w r,- n
CD E
a 5
o0
z o
U
REVISIONS:
A \ (RED LILACS /CLI�RIEIG�TIONS)
(8-2/-W) O
COMMEI'ITS FROM CI -IY
O FIRE
L) E P'I N OV. 1 0, 02
ONEW H.C. BATHROOMS
JANUARY 2003
UN- EDITED
WHENEVER POSSIBLE, UTILIZE EXISTING NEARBY STUB -UPS, EVEN
IF NEW STUB -UPS ARE SHOWN ON THESE DRAWINGS, IF THAT
IS NOT POSSIBLE, THEN INSTALL NEW STUB -UPS WHERE SHOWN
AND CONNECT TO NEARBY STUB -UPS TO MINIMIZE FLOOR CUTTING,
AVOID AS MUCH AS POSSIBLE TRENCHING FLOOR TO RUN CONDUITS
BACK TO RESPECTIVE PANELS, N❑ EXISTING AS -BUILT DRAWINGS
WERE AVAILABLE DURING THE COURSE OF DESIGN, CONTRACTOR WILL
NEED TO FIELD VERIFY ALL EXISTING CONDITIONS PRI ❑R TO BIDDING,
34, ELECTRICAL CONTRACTOR TO FURNISH TELEPHONE CABLE AND CONDUIT,
FROM THE TELEPHONE BOARD TO PHONE JACK AT EACH LOCATION SHOWN,
SEE DETAIL ON DETAIL SHEET,
35, CONTRACTOR SHALL VERIFY LOADS WITH ACTUAL NAMEPLATE RATINGS OF ALL
TENANT FURNISHED EQUIPMENT, WHERE CONFLICTS OCCUR, NOTIFY ARCHITECT
AND WINN -DIXIE MAINTENANCE /CONSTRUCTION SUPERVISOR,
36, WHERE NEW CASES ARE BEING INSTALLED IN THE SAME L ❑CATION AS EXISTING
CASES, THE CONTRACTOR SHALL ATTEMPT TO UTILIZE THE EXISTING WIRE AND
CONDUIT BEFORE DIGGING UP THE FLOOR TO INSTALL NEW LINES,
37, CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL SEVICE TO REFRIGERATI ❑N
COMPRESSORS AND ALL OTHER AREAS OF WORK AS NECESSARY,
38 ELECTRICAL CONTRACTOR SHALL VERIFY COMPRESSOR NAMEPLATE RATINGS
WITH WINN -DIXIE MAINTENANCE SUPERVISOR BEFORE ORDERING AND BREAKERS
OR RDP PANEL,
39, ALL NEW DELI AND BAKERY EQUIPMENT SHALL BE CONNECTED WITH FLEXIBLE
GREASE RESISTANT CORD AND CAP,
40. ELECTRICAL CONTRACTOR SHALL DISCONNECT EXTG, AMPLIFIER AND TURN OVER
TO WINN- DIXIE. RE- CONNECT EXISTING 200 WATT AMPLIFIER PROVIDED BY W /D.
41. CONTRACTOR TO RE- CONNECT AIDPHONE SYSTEM THROUGHOUT THE THE STORE,
AS NOTED ON THE PLANS,
42. ALL CIRCUITS FOR EQUIPMENT IN MEAT CUTTING ROOM SHALL
BE RUN OVERHEAD UNLESS NOTED OR INDICATED OTHERWISE,
43, CONTRACTOR TO FURNISH AND INSTALL SMOKE DETECTOR
IN THE OFFICE AND COMPUTER ROOM AS MANUFACTURED
BY ADT MODEL ESL521,
44, IN OFFICE WHERE COUNTERS ARE PRESENT, RECEPTACLES SHALL
BE MOUNTED 6" ABOVE COUNTERTOP ISOLATED GROUND
RECEPTACLES SHALL BE MOUNTED G" BELOW COUNTERTOP,
45. CONTRACTOR SHALL FURNISH AND INSTALL (2) 1 -112" CONDUITS WITH
PULL STRING FROM JUNCTI ❑N BOX IN ELECTRCAIL ROOM TO JUNCTION BOX IN
ATTIC AT FUTURE BANK AREA,
PLANS WERE PREPARED FROM EXISTING DRAWINGS
BY F. EARL LEGGET ARCHITECT - TAMPA (UNDATED)
GLASSER ASSOC. ARCH. DATED 6/30/72
IT IS CONTRACTOR RESPONSABILITY TO VERITY AND
COORDINATE ALL EXISTING CONDITIONS IN FIELD AND
ADJUST OR PROVIDE NEW AS REQUIRED.
a
I
e
a
I
IG
Z
w
� I
t
LC ■■
W �
z
l
C�
a
a
i
w <
LL°
0 N OI I
0 W LL
Q
0 W
Ld
D
0� W
z o
Z Lo
Lo O
DRAWING NO.
E -101 OF -
SHEET NO.
OF