12-1163-007PB BOXES & FITTINGS ( COUNG MOUNTED JUNCTION BOX CB 3P 100 WALL MOUNTED JUNCTION BOX , 18' A.F.F. A.F.F. OR AS OTHERWISE NOTED. C.B. CEIUNG MOUNTED JUNCTION BOX, 12'Xi2'X6' a DEEP UNLESS OTHERWISE INDICATED. FOR COND. OR C. DISTRIBUTION OF TO- PHONE PB PULLBOX, SIZED AS INDICATED OR AS 50 REQUIRED BY N.E.C. CB 3P 100 SYMBOL SUFFIXES A.F.F. ABOVE FINISHED FLOOR C.B. CIRCUIT BREAKER CKT. CIRCUIT COND. OR C. CONDUIT E EXISTING EC. EMPTY CONDUIT E.W.C. ELECTRIC WATER COOLER E.W.H. ELECTRIC WATER HEATER ENCL ENCLOSURE FA FIRE ALARM CA GROUND FAULT INTERRUPTER. GND GROUND HID HIGH INTENSITY DISCHARGE PNL PANEL SW. SWITCH U.O.N. UNLESS OTHERWISE NOTED WP INDICATES WEATHERPROOF NEMA 3R EQUIPMENT MTD. MOUNTED -a FUSE AS PER MANUFACTURER'S = RECOMMENDATION MVD MANUAL VOLUME DAMPER An ARC FAULT INTERRUPTER NC NON - CONCURRENT PANELBOARDS Z Z POWER, LIGHTING OR DISTRIBUTION - PANELBOARD. (NEW) Q TRANSFORMER WALL OR FLOOR MOUNTED; SIZE Q AND MOUNTING AS INDICATED ON DWGS. v___Q FIRE ALARM SD CEILING MOUNTED SMOKE DETECTOR. SD ER CEILING MOUNTED SMOKE DETECTOR, 'ER' DENOTES ELEVATOR RECALL FUNCTION. DD DUCT MOUNTED SMOKE DETECTOR. � (PROVIDE W/ SHUT DOWN RELAY) HJ COUNG MOUNTED HEAT DETECTOR. 0 MANUAL ARE ALARM PULL STATION. 42' A.F.F. ELECTRICAL SYMBOL LEGEND FIRE ALARM WIRE LEGEND FIRE ALARM TINGE' 80' A.F.F. 50 IUD CD CB 3P 100 ARE ALARM SPEAKER, & STROBE LIGHT 80' A.F.F. OA MINIMUM 75 CD RATING a TAMPER SWITCH. a FLOW SWITCH. ® SINGLE STATION SMOKE DETECTOR, 12OV, WITH BATTERY BACK -UP SS SAME AS ABOVE WITH BATTERY BACK -UP FOR 90 MIN. ® SHUT DOWN RELAY. FAAP ARE ALARM ANNUNCIATOR PANEL FACP ARE ALARM CONTROL PANEL ® SINGLE STATION ANNUNCIATOR PANEL M ANNUNCIATE PER FLOOR. Cn ARE ALARM ANNUNCIATOR PANEL m LCD DISPLAY & SILENCIING CAPABILITIES DH MAGNETIC DOOR HOLDER ® AUTO DIALER ELECTRICAL SYMBOL LEGEND FIRE ALARM WIRE LEGEND FGAP-1 GENERATOR ANNUNCIATOR PANEL AS PER NFPA 101 DTELEPHONE OUTLET , 18' A.F.F. ROUTE 3/4" EMPTY CONDUIT UP TO COLING COMBINATION TR PHONE/ DATA OUTLET. ROUTE 3/4" E.C. UP TO CEILING <9> LIGHTNING PROTECTION NR TERMINAL, 24'H 'El ADA PUSH- BUITON, WEATHER PROOF M MOTORIZED DAMPER ® ARE SMOKE DAMPER V® VARIABLE AIR VOLUME BOX RECEPTACLES E)= 12OV.,1 PHASE, 60 HZ., 20 AMP. DUPLEX RECEPTACLE MTD.. 24' A.F.F., SAME AS ABOVE EXCEPT MID. AT 6' ABOVE COUNTER MOUNT RECEPTACLE HORIZONTALLY 120V.,1 PHASE, 60 hz., 20 AMP. DUAL DUPLEX RECEPTACLE MTD. 24' A.F.F. 0= SPECIAL PURPOSE RECEPTACLE 2P -30 2P. DENOTES POLES, 30 DENOTES AMPERAGE RATING SWITCHES SINGLE POLE TOGGLE SWITCH, 20A., S a 120/277 VAC. MOUNTED 42' A.F.F. a ' SWITCH LEG. S S c THREE -WAY AND FOUR WAY TOGGLE SWITCHES 3 4 120/277 VAC. MOUNTED 42' A.F.F. DIMMER SWITCH, 1000 WATTS MINIMUM UNLESS S D OTHERWISE NOTED. 42' A.F.F. SINGLE POLE TOGGLE SWITCH 20 A 120/277 VOLT S K WITH LOCKING COVER - HUBBEL CAT 196061DCH MTD. 42' A.F.F. SINGLE POLE LKGTTED HANDLE TOGGLE SWITCH. S P 20 A, 120/277 VAC. MOUNTED 42' A.F.F. MANUAL MOTOR STARTER TOGGLE SWITCH S M WITH OVERLOADS. 42' A.F.F. 3P 60 INNTIATING - SHOLDED PAIR - EQUAL TO WP 975 FPLP, 118 T.S.P. AWG. 50 AUDIOVISUAL #12 THHN CB 3P 100 LIGHTING OA LIGHTING FIXTURE TYPE SEE LTG. FIXTURE 1� SCHEDULE THIS SHEET 02a DOWNUGHT /PARKING LOT ON NORMAL CIRCUIT A-113.5 2 IS CIRCUIT N0; • SAME AS ABOVE WITH BATTERY BACK -UP FOR 90 MIN. ® SURFACE OR PENDANT MOUNTED FLUORESCENT FIXTURE m SURFACE OR PENDANT MOUNTED FLUORESCENT FIXTURE WITH BATTERY BACK -UP FOR 90 MIN. M FLUORESCENT RECESSED OR LAY -IN Cn FIXTURE, NORMAL. BRANCH CIRCUIT m FLUORESCENT RECESSED OR LAY -IN FIXTURE, WITH BATTERY BACK -UP FOR 90 MIN. ca SURFACE MOUNTED SINGLE FACE EXIT LIGHT W FIXTURE WITH ARROWS AS INDICATED, z_ WITH BATTERY BACK -UP FOR 90 MIN. WALL MOUNTED EXIT LIGHT FIXTURE WITH ARROWS AS -� INDICATED,WNH BATTERY BACK -UP FOR 90 MIN. SURFACE MOUNTED DOUBLE FACE EXIT LIGHT Ir FIXTURE WITH ARROWS AS INDICATED, -a WITH BATTERY BACK -UP FOR 90 MIN. I 0 (Z7 WALL MOUNTED DOUBLE FACE EXIT LIGHT FIXTURE W1ARROWS AS INDICATED. -� WITH BA BACK -UP FOR 90 MIN. 1�­! PENDANT MITI. STRIP FLUORESCENT FIXTURE ON NORMAL BRANCH CIRCUIT PENDANT MID. STRIP FLUORMff FIXTURE Z Z WITH BATTERY BACK -UP FOR 90 MIN. W COMBINATION EXIT BATTERY BACK -UP LIGHT FOR 90 MIN. MISCELLANEOUS Q GROUND ROD BOX (BROOKS #36) v___Q ELECTRICAL ROOM GROUND BAR ASSEMBLY FGAP-1 GENERATOR ANNUNCIATOR PANEL AS PER NFPA 101 DTELEPHONE OUTLET , 18' A.F.F. ROUTE 3/4" EMPTY CONDUIT UP TO COLING COMBINATION TR PHONE/ DATA OUTLET. ROUTE 3/4" E.C. UP TO CEILING <9> LIGHTNING PROTECTION NR TERMINAL, 24'H 'El ADA PUSH- BUITON, WEATHER PROOF M MOTORIZED DAMPER ® ARE SMOKE DAMPER V® VARIABLE AIR VOLUME BOX RECEPTACLES E)= 12OV.,1 PHASE, 60 HZ., 20 AMP. DUPLEX RECEPTACLE MTD.. 24' A.F.F., SAME AS ABOVE EXCEPT MID. AT 6' ABOVE COUNTER MOUNT RECEPTACLE HORIZONTALLY 120V.,1 PHASE, 60 hz., 20 AMP. DUAL DUPLEX RECEPTACLE MTD. 24' A.F.F. 0= SPECIAL PURPOSE RECEPTACLE 2P -30 2P. DENOTES POLES, 30 DENOTES AMPERAGE RATING SWITCHES SINGLE POLE TOGGLE SWITCH, 20A., S a 120/277 VAC. MOUNTED 42' A.F.F. a ' SWITCH LEG. S S c THREE -WAY AND FOUR WAY TOGGLE SWITCHES 3 4 120/277 VAC. MOUNTED 42' A.F.F. DIMMER SWITCH, 1000 WATTS MINIMUM UNLESS S D OTHERWISE NOTED. 42' A.F.F. SINGLE POLE TOGGLE SWITCH 20 A 120/277 VOLT S K WITH LOCKING COVER - HUBBEL CAT 196061DCH MTD. 42' A.F.F. SINGLE POLE LKGTTED HANDLE TOGGLE SWITCH. S P 20 A, 120/277 VAC. MOUNTED 42' A.F.F. MANUAL MOTOR STARTER TOGGLE SWITCH S M WITH OVERLOADS. 42' A.F.F. 3P 60 SAFETY SWITCH, 3P = NO. OF POLES. 50 60 = SWITCH SIZE, 50 = FUSE SIZE. CB 3P 100 ENCLOSE) CIRCUIT BREAKER,3P = NO. OF POLES 70 100 = FRAME SIZE & 70 = TRIP RATING. 1� WIRING W HOMERUN TO PANEL A'.1 -3-5 ARE A-113.5 CIRCItTT NO'S. TICKS ARE NO. OF CONDUCTORS �- (,/)INDICATES GROUND WIRE SIZED AS PER cn N.E.C. ART. 250. INDICATES A EXISTING CONDUIT RUN CONCEALED IN A CEILING OR WAIL. INDICATES A CONDUIT RUN CONCEALED IN - - FLOOR. EMBEDDED IN CONCRETE OR UNDERGROUND. - - - -- INDICATES AN DOSTING CONDUIT RUN. ] INDICATES A CAPPED CONDUIT. INDICATES A FLEXIBLE METAL CONDUIT CONNECTION. USE LIQUID TIGHT CONDUIT IN WET, DAMP OR OILY LOCATIONS. \AAAAAA FLEXIBLE EQUIPMENT CONNECTION. GROUNDING SYSTD,1 CONDUCTOR, BARE COPPER -G -G- CONDUCTOR OR INSULATED CONDUCTOR IN CONDUIT AS INDICATED. ♦ CONDUIT RUN TURNED DOWN. - -o CONDUIT RUN TURNED UP. x CONDUIT EXPANSION JOINT T LIGHTNING PROTECTION CLASS I WIRING /AIR TERMINAL MOTORS & CONTROLS 5 MOTOR, 5 = 5 H.P. OR AS OTHERWISE INDICATED. ® MOTOR MAGNETIC STARTER. Lz MOTOR COMBINATION STARTER AND DISCONNECT. ®S DUCT MOUNTED FIRESTAT. LED= DUCT HEATER WITH CONTACTOR AND SAFETY DISCONNECT. OT THERMOSTAT ELECTRICAL NOTES: 1. MATERIALS AND INSTALLATION, AS A MINIMUM, ARE TO CONFORM WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE, N.F.P.A., LOCAL CODES, ORDINANCES, INCLUDING ALL AMENDMENTS TO THE N.E.C. EQUIPMENT WHERE APPLICABLE, WILL BE LISTED WITH THE UNDERWRITER'S LABORATORIES, INC. QUALITY AND WORKMANSHIP ESTABLISHED BY DRAWINGS AND SPECIFICATIONS ARE NOT TO BE REDUCED BY THE ABOVE MENTIONED CODES. 2. BIDDERS ARE TO VISIT THE SITE AND FAMILIARZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORSEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. 3. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST -CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM IS TO BE FULLY OPERABLE AND ACCEPTANCE OF THIS SYSTEM BY THE ENGINEER MUST BE A CONDITION OF THE SUB CONTRACT. 4. ALL WORK TO BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 5. CONTRACTOR TO GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. 6. CORRECTION OF ANY DEFECTS TO BE COMPLETED WITHOUT ADDITIONAL CHARGE AND TO INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 7. ALL REQUIRED INSURANCE TO BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABIUTY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 8. CONTRACTOR TO PAY FOR ALL PERMITS, FEES INSPECTIONS AND TESTINGS. 9. ELECTRICAL INSTALLATION TO MEET ALL STANDARD REQUIREMENTS OF LOCAL POWER AND TELEPHONE COMPANIES. ELECTRICAL CONTRACTOR SHALL CONTACT LOCAL POWER AND TELEPHONE COMPANIES PRIOR TO START OF CONSTRUCTION. 10. ALL WIRING SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED, MINIMUM WIRE SIZE SHALL BE 114 AWG. EXCLUDING CONTROL WIRING. ALL CONDUCTORS SHALL BE COPPER WITH THWN/THHN INSULATION. CONDUCTORS #10 AND SMALLER MAY BE SOLID; ALL THOSE #8 AND LARGER TO BE STRANDED. 11. ALL UNDERGROUND RACEWAYS SHALL BE MINIMUM 3/4 °, SCHEDULE 40 PVC. ALL OTHER RACEWAYS TO COMPLY WITH GOVERNING CODES. WHERE RIGID STEEL IS USED, IT SHALL BE COMPLETELY COATED WITH AN ALKALI AND RUST RESISTANT BITUMASTIC PAINT, COPPER NO. 50, AND THREADS SHALL BE COATED WITH ZINC CHROMATE. RIGID STEEL SHALL ALSO BE USED WHEN CONDUIT IS EXPOSED TO EXTERIOR ENVIRONMENT SUCH AS EXTERIOR OF BUILDING OR WHERE IT IS EXPOSED AND SUBJECT TO DAMAGE, INSIDE OF BUILDING. 12. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS, AND BE OF SPECIAL CONSTRUCTION FOR OTHER CLASSIFIED AREAS. ALL BOXES SHALL BE RECESSED (FLUSH) IN WALLS OR CEILINGS WHENEVER POSSIBLE. 13. DISCONNECT SWITCHES SHALL BE H.P. RATED, GENERAL DUTY, QUICK -MAKE, QUICK -BREAK TYPE. ENCLOSURES SHALL BE AS REQUIRED BY N.E.C. AND LOCATION (WEATHERPROOF, EXPLOSION PROOF, ETC.). ENGRAVED LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND INSTALLED ON ALL DISCONNECT SWITCHES, CONTACTORS AND STARTERS. 14. ALL FUSES FOR SAFETY SWITCHES SHALL BE DUAL ELEMENT, CARTRIDGE TYPE. FUSES SHALL BE THOSE MANUFACTURED BY EITHER BUSSMAN OR UTTLEFUSE. THE CONTRACTOR SHALL FURNISH TO THE OWNER ONE SPARE FUSE FOR EACH SIZE AND TYPE OF FUSE INSTALLED. FUSES 600 AMPS. OR LESS SHALL BE CLASS RK1, TYPICAL UNLESS OTHERWISE NOTED. FUSES OVER 600 AMPS. SHALL BE CLASS L. 15. ALL GENERAL PURPOSE SWITCHES AND RECEPTACLES SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER. 16. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM, AND PROVIDE ALL NECESSARY DEVICES AND COMPONENTS FOR EQUIPMENT BE PLACED IN PROPER WORKING ORDER. 17. A SEPERATE, GREEN TYPE THWN COPPER GROUND CONDUCTOR SHALL BE RUN FROM GROUND LUG OF EACH GROUNDED RECEPTACLE TO AN APPROVED CONNECTION INSIDE THE ENCLOSING STEEL OUTLET BOX. DEVICE MOUNTING SCREWS SHALL NOT BE CONSIDERED AN APPROVED GROUND. A SEPERATE GROUND CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT AND RACEWAY AND SECURELY BONDED IN AN APPROVED GROUNDING TERMINAL AT BOTH ENDS OF THE RUN. THE GROUNDING CONDUCTOR SHALL BE SIZED IN ACCORDANCE WITH TABLE 250 -95 OF THE N.E.C. CONTRACTOR SHALL SIZE CONDUIT TO ACCOMMODATE ADDITIONAL CONDUCTOR. 18. LOAD DATA IS BASED ON INFORMATION GIVEN TO THE ENGINEER AT THE TIME OF DESIGN. VERIFY ALL EQUIPMENT NAMEPLATE RATINGS BEFORE ORDERING. 19. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR IS TO PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDITIONS. 20. FURNISH AND INSTALL DISCONNECT SWITCHES, WIRING, AND CONNECTIONS ON AIR CONDITIONING SYSTEM AS SHOWN ON PLANS. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE WITH MECHANICAL CONTRACTOR REGARDING SUPPLY AND INSTALLATION OF ALL REQUIRED CONTROLS. 21. ALL FLUORESCENT LIGHT FIXTURES SHALL HAVE IN LINE FUSING AND ENERGY SAVING BALLASTS. (ONLY REQUIRED IN MIAMI DADE COUNTY) 22. ALL SWITCHGEAR, PANELS, STARTERS, CONTACTORS ETC., SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER, THE SYSTEM DESIGN IS BASED ON SQUARE 'D'; HOWEVER, COMPARABLE EQUIPMENT BY G.E. & SIEMENS WILL BE ACCEPTABLE. TANDEM AND HALF -SPACE CIRCUIT BREAKERS SHALL NOT BE USED. 23. TYPEWRITTEN CIRCUIT INDEX SHALL BE AFFIXED TO INSIDE SURFACE OF EACH PANELBOARD DOOR, CLEARLY INDICATING AREA AND TYPE OF LOAD SERVED BY EACH BRANCH CIRCUIT PROTECTIVE DEVICE, INCLUDING SPARES. HAND PRINTED WILL NOT BE ACCEPTED. 24. ENGRAVED, LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND INSTALLED ON ALL PANELS AND SWITCHGEAR. PLATES SHALL BE AFFIXED TO FRONT OF PANELS, INDICATING PANEL NAME, VOLTAGE AND AMPERAGE. 25. ALL UNDERGROUND PVC CONDUIT RUNS SHALL HAVE RIGID STEEL ELBOWS AND RIGID STEEL SECTIONS AT SLAB PENETRATIONS WHERE SUBJECT TO POSSIBLE DAMAGE. WHERE RIGID STEEL IS USED, IT SHALL BE COMPLETELY COATED WITH AN ALKALI AND RUST - RESISTANT BITUMASTIC PAINT, COPPER NO. 50, AND THREADS SHALL BE COATED WITH ZINC CHROMATE. 26. THE ELECTRICAL CONTRACTOR SHALL MEET AND COORDINATE WITH THE LOCAL POWER COMPANY AT THE SITE PRIOR TO CONTRUCTION. AT THAT TIME, THE CONTRACTOR SHALL COORDINATE ALL RELATED WORK WITH THE UTILTTY COMPANY'S RESPONSIBILITIES TO MEET THE OWNER'S SCHEDULE. 27. ALL ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN AN APPROVED RACEWAY, EMT, IMC, RIGID GALVANIZED CONDUIT OR SCEDULE 40 PVC MAXIMUM NUMBER OF 120V CIRCUITS ALLOWED IN A COMMON CONDUIT SHALL BE SIX (6). THE CONTRACTOR SHALL STRICTLY CONFORM TO THE N.E.C. REQUIREMENTS OF DERATING FOR CONDUCTOR AMPACITY AND CONDUIT FILL. 28. CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: 208V SYSTEM NEUTRAL - WHITE PHASE A - BLACK PHASE B - RED PHASE C - BLUE GRD.CON - GREEN 29. CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL CONDUIT PENETRATIONS MADE THROUGH FIRE RATED WALLS, CEILINGS, SLABS, ETC. PENETRATION SEALS SHALL BE PER U.L. ASSEMBLY STANDARDS. 30. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF CONTRACT DRAWINGS AT JOB SITE WITH COLORED MARKINGS INDICATING PROGRESS OF WORK. THIS SET OF CONTRACT DRAWINGS IS TO BE SEPERATE FROM AND IN ADDITION TO CONTRACTOR'S CONSTRUCTION SET. EVERY UNIT OF EQUIPMENT, DEVICE, CONDUIT AND WIRE IS TO BE MARKED WHEN INSTALLED. USE GREEN TO INDICATE INSTALLATION AS SHOWN ON RAWINGS AND USE RED TO INDICATE FIELD CHANGES. UPON COMPLETION OF WORK, THIS SET OF CONTRACT DRAWINGS IS TO BE TURNED OVER TO, AND BECOME PROPERTY OF THE ELECTRICAL ENGINEER. 31. IF ELECTRICAL CONTRACTOR HAS QIUESTIONS, OR IN THEIR OPINION FINDS OMISSIONS OR ERRORS ON ELECTRICAL DOCUMENTS, IT IS THEIR RESPONSIBILITY TO BRING THIS TO THE ATTENTION OF THE ELECTRICAL ENGINEER IMMEDIATELY. IF ELECTRICAL CONTRACTOR PROCEEDS WITH ANY CHANGES TO THE CONTRACT DOCUMENTS, WITHOUT WRITTEN PRIOR APPROVAL FROM THE ELECTRICAL ENGINEER, CONTRACTOR WILL NOT BE COMPENSATED. t� TE; OF � e OS'10 PJAI+ VIDAL & ASSOCIATES INC. CONSULTING ENGINEERS 2234 N.E. 2ND. AVENUE MIAMI, FL. 33137 HENRY VIDAL P.E., PE# 56204 CERTIFICATION OF AUTHORIZATION #9056 PHONE: (305) 571 -1860 FAX: (305) 571 -1861 E -MAIL: WIDAL @VIDALDSN.COM COPYRIGHT© U^ ZN ch C9 Ch O w O D E m M fN 1.1.., E U ? G L U W moo= IE = U cd u., U 2 'ni Q 0 U) (3j vi Qv o ° cm co c (-- a a ci F- W H 2 U Q 0 w ¢ ° U ° c o 0 o z ° ac w r ¢Wi-' = CD,~ ] 2 O co= S°CC cc oZ° U o¢¢oowc Q C/) W wcna a=v�� Q csn- z U3 U w o ¢ ¢ LL U ° _U Lu Z O �- O W U m =W�osr -a N� =moo °oo °o I SEAL ou ca Z N c0 0 Z 1� W Q CID �- cn z M QU) Cn Lu _j m F- 0 ca 0 W z_ W �! Ilr Ir CY] m Z Z W W C) z cl) Cy) W OZLJL � W _ 0 O 2 o- Z m w C> o! 0 t1 0 I SEAL W a O LL O U w oN ¢r o_ E -1.0 SHEET ou ca Z m Z 1� W Q CID �- cn M QU) Cn Lu _j m F- ca 0 W z_ W �! Ilr Ir CY] Z Z W W C) z cl) Cy) W OZLJL � W _ 0 O 2 If) Q m L) W a O LL O U w oN ¢r o_ E -1.0 SHEET ou ca W Z 1� W Q CID Z W O W Lu _j m W ca 0 y z_ Q W a O LL O U w oN ¢r o_ E -1.0 SHEET