Loading...
13-720-014�:x --1 P yra. mow'• Chem Pyro -Chem Kitchen Knight 11 KITCHEN Pipe volumes KNIGHT II Volume Chart 1/4 in. pipe = 20.5 mis. /ft. ��. 3/8 in. pipe = 37.5 mis. /ft. 1/2 in. pipe = 59.8 mis. /ft. 3/4 in. pipe = 105.0 mis. /ft. Tank Chart General Piping Requirements 1. Split piping and straight piping are both allowed on a PCL -160, PCL -300 and PCL -460 system. 2. PCL -600 systems must use split piping only, with no nozzle located before the split, and with a maximum of 14 flow points per side. 1/2 in. mini- mum piping must be used up to the first split. 3. Maximum volume for 1/4 in. pipe between a nozzle and the preceding tee is 410 mis. 4. Maximum flow numbers for 1/4 in. pipe is 6. 5. Maximum number of elbows between a nozzle and the preceding tee is 5. 6. Maximum of 25 elbows are allowed in the total piping system. 7. Maximum difference in elevation between the tank outlet and any nozzle, or the tank outlet and the highest or lowest horizontal pipe run, Is 10 ft. (3.1 m). 8. No traps are allowed in the piping network. 9. Pipe lengths are measured from center to center of fittings. 10. The internal equivalent length volume of fittings does not have to be considered as part of the total pipe volume. 11. When utilizing different size pipe in the system, the largest size must start first and the additional pipe must decrease as it approaches the nozzle. 12. Elbow(s) or swivel adaptors located at the nozzles do not have to be counted in the 25 elbow maxi- mum requirement. 13. Reducing bushings are allowed when reducing to a smaller pipe size. 14. Additional piping requirements when protecting a range, wok, or a fryer. • PCL -160 - Minimum of 239 ml and one (1) flow number required in total system. Of that mini- mum, 180 ml must be utilized at or before the range, wok, or fryer. • PCL -300 - Minimum of 300 ml and four (4) flow numbers required In total system. Of that mini - mum, 239 ml and two (2) flow numbers must be utilized at or before the range, wok, or fryer. • PCL -460 - Minimum of 660 ml and ten (10) flow numbers required in total system. Of that mini - mum, 180 ml and two (2) flow numbers must be utilized at or before the range, wok, or fryer. • PCL -600 - Minimum of 960 ml and fourteen (14) flow numbers required in total system. Of that minimum, 120 ml and 2 flow numbers must be utilized at or before the range, wok, or fryer. Minimum Pipe Volumes for a Fryer, Range, and Wok Cylinder Size Entire System Maximum PCL 160 239 ml - 1 Flow Pt 180 ml - 1 Flow Pt Volume Allowed 300 ml - 4 Flow Pis 239 ml - 2 Flow Pis Maximum Between First 180 ml - 2 Flow Pts Maximum Pipe Nozzle and Tank Flow Volume Last Nozzle Size Numbers (milliliters) (milliliters) 1.6 Gallon 5 1500 600 PCL -160 48 1 2 3.0 Gallon 10 1910 1125 PCL -300 DEEP FAT FRYER - DRIP PAN (VAT 19 1/2 "x19" MAX.) 2H 2L 2 4.6 Gallon 14 3400 3000 PCL -460 W DEEP" FAT FRYER (LAW PROXIM" - DRIP PAN (VAT 19 1/2 "x19" MAX.) 13 4.6 Gallon 15 2600 2000 PCL -460 1 12 28 6.0 Gallon 19 4215 1688 PCL -600 13 24 per side 6.0 Gallon 20 3465 1313 PCL -600 28 24 per side Minimum Pipe Volumes for a Fryer, Range, and Wok Cylinder Size Entire System At or before appliance PCL 160 239 ml - 1 Flow Pt 180 ml - 1 Flow Pt PCL 300 300 ml - 4 Flow Pis 239 ml - 2 Flow Pis PCL 460 660 ml - 10 Flow Pis 180 ml - 2 Flow Pts PCL 600 1960 ml - 14 Flow Pts 1120 ml - 2 Flow Pts PYROCHEM PCL160- PCL300- PCL460- PCL600 NOZZLE COVERAGE SUMMARY SHEET APPLIANCE NOZZLE TYPE FLOW POINTS WIDTH LENGTH MIN HEIGHT (IN) MAX HEIGHT (IN) NUMBER OF NOZZLES NUMBER OF FLOW POINTS DEEP FAT FRYER - VAT 2H 2L 2 19 1 / 2 19 24 48 U U.J �(a 0 DEEP FAT FRYER (LOW PROXIMITY) - VAT 13 24 W Z DEEP FAT FRYER - DRIP PAN (VAT 18 "X18" MAX.) 2H 2L 2 27 3/4 500(18) 1 24 48 1 2 DEEP FAT FRYER (LOW PROXIMITY) - DRIP (VAT 18 "08° MAX) 13 1 24 PERIMETER STROBE DEEP FAT FRYER - DRIP PAN (VAT 19 1/2 "x19" MAX.) 2H 2L 2 25 3/8 495(18) 24 48 W DEEP" FAT FRYER (LAW PROXIM" - DRIP PAN (VAT 19 1/2 "x19" MAX.) 13 24 ® TWO BURNER RANGE 1H 1L 1 12 28 40 50 1 1 TWO BURNER RANGE (LOW PROXIMITY) 13 24 --------- - - - - -- ----- - - - - TWO BURNER RANGE W/ BACKSHELF (LOW MOUNT NOZZLE) 2L 2 12 28 24 35 2.5' FOUR BURNER RANGE 2L 2 28 28 34 48 EMT W SMALL WOK 1H 1L 1 24" dia. 6" depth 24 48 SMALL WOK (LOW PROXIMITY) 13 24 REVISIONS NUM LARGE WOK 2H 2L 2 30" dia. 8° depth 24 48 LARGE WOK (LOW PROXIMITY) 13 24 300 SMALL GRIDDLE 1H 1 36 1080(30) 24 48 1 1 SMALL GRIDDLE (LOW PROXIMITY) 1L 10 24 any third party in any form or manner BROILER SMALL GRIDDLE - ALTERNATE PROTECTION (HIGH PROXIMITY) 2H 2L 2 36 1080(30) 24 48 1L 3607 SMALL GRIDDLE - ALTERNATE PROTECTION (LOW PROXIMITY) . 13 24 5 OF 5 LARGE GRIDDLE 2L 2 48 1440(30) 24 48 GRIDDLE RANGE LARGE GRIDDLE (LOW PROXIMITY) 14 24 GAS RADIANT CHAR - BROILER 1H 1L 1 26 624 ( 24 ) 24 48 4I GAS RADIANT CHAR - BROILER (LOW PROXIMITY) 13 24 (NO COVERAGE) LARGE RADIANT CHAR - BROILER 2H 2L 2 36 24 36 48 CLASS LARGE RADIANT CHAR BROILER (LOW PROXIMITY) 13 36 LAVA ROCK CHAR - BROILER 2L 2 26 624(24) 15 35 NATURAL CHARCOAL CHAR - BROILER (MAX. FUEL DEPTH 6") 1H 1L 1 24 480(20) 24 48 NATURAL CHARCOAL CHAR - BROILER (LOW PROXIMITY) 15 24 MESQUITE CHAR - BROILER (MAX. FUEL DEPTH 6-) 1H 1L 1 24 480(20) 24 35 suRFACE MESQUITE CHAR - BROILER (LOW PROXIMITY) 15 24 MAXIMUM FROM HOOD UPRIGHT /SALAMANDER BROILER 1L 1 36 W 28 D Front edge: Above the grate 1 1 CHAIN BROILER (INTERNAL CHAMBER) 1L 1 36 W 28 D Front edge: 1 -3" above the chain TILT SKILLET /BRAJSING PAN Coverage limitations are based on fryer sizes including the drip boards. Exception: Tilt Skillets and Braising Pans may exceed maximum of 6 sq. ft. PLENUM NOZZLE TYPE FLOW POINTS WIDTH FT LENGTH FT°a1 NowAs placement (nee for more details NTS SINGLE BANK/V BANK 1H 1 4 10 0" - 6" from end of plenum 1 DUCT NOZZLE TYPE FLOW POINTS DIAGONAL (IN) DIAMETER (IN) LENGTH (IN) RECTANGULAR /CIRCULAR 1L 1 r37.7375 50 16 UNLIMITED RECTANGULAR /CIRCULAR 2D 2 100 31 7/8 UNLIMITED 1 2 RECTANGULAR /CIRCULAR (2) 2D 4 51 150 47 1/2 UNLIMITED CYLINDERS TOTAL FLOW POINTS 8 No. 1 TOTAL gypE MAX FLOW POINTS FLOW PTS USED PCL160 5 PCL300 10 8 PCL460 15 PCL600 20 8 I i i i PCL 300 CYLINDER "QUIK 360 DEGREE SYSTEM COMPONENTS TO LINK N cn Z CD SHOWN HERE FOR CLARITY STATIONS 1/2" EMT , 8' -0" H F- 0000 Ua o v 00 Z Imn ALL PIPING Z W E -j OawUO U U.J �(a 0 3/8" BLACK 2D ■ < (D U LU Q_ U m f- rj W Z ��rr L LU ¢ LL IRON Z U� U DUCT 13x13 HORN & 0 o ` ",IIIIIfffff D 2: .5 52 PERIMETER STROBE '1 w , . KU o o ri y W (D U-1 ® It C.5, Oo n F-11 1 H 1 1 1 LU H Z V) --------- - - - - -- ----- - - - - -- - -- - 1/2" EMT vI 1/2' 2.5' 1H 1H 2H H PYRO U EMT W C C CHEM MECHANICAL PLAN REVISIONS NUM DATE DESCRIPTION PCL REMOTE PULL STATION 300 SALAMANDER AT PATH OF EGRESS 2010 BUCHANAN P.E. CONSULTING. All information, drawings,and designs are not to be copied, reproduced, changed, transferred, or disclosed to any third party in any form or manner BROILER so ever without the express written permission from Buchanan P.E. Consulting,Inc. (SEE PLAN) DATE: 04 -01 -13 SCALE: ALVE 1L 3607 SHEET ' 0 5 OF 5 REFRIGERATED CHEF BASE GRIDDLE RANGE FRYER 48x30 24x24 12x28 1404 4I K (NO COVERAGE) CLASS DIMENSIONS K CLASS FIRE REPRESENT THE COOKING EXTINGUISHER 30 FEET suRFACE MAXIMUM FROM HOOD (SEE PLAN) FRONT ELEVATION NTS . • 1 . i 8" HIGH STEEL BAFFLE PLATE (NFPA 96, 2008, 12.1.2.5) 80" FIRE EXTINGUISHER >TRUCTIONS, LESS 30' FROM HOOD IFY LOCATION) P i P 300. GENERAL NOTES: 1. Systems comply with UL 300. -► 2. Systems comply with NFPA 17, 17A and 96 -2008. 3. All pipe run in black iron. 4. All changes in direction of conduit shall be be made with corner pulleys. 5. Upon activation of the fire system: A. Make -up air fan(s) must shut down. B. All electric appliances and outlets under the hood must shut down. C. Exhaust fan must continue to run, or turn on if control switch is in the off position. D. Alarm device (horn & strobe) must activate. F. Gas supply must shut off. 6. "K" Class fire extinguisher located less than 30 feet from hood. 7. There is no building fire alarm. SYSTEM COMPLIANCE NOTES NFPA 17A 2009 EDITION 4.5.2 All piping and fittings are black iron. 5.1.5 If applicable, two or more hazards protected by same system or simultaneously operated systems. 5.2.1.6 Manual actuator provided. 5.2.1.7 All operating devices protected. 5.2.1.8 Audible and /or visual indicator provided. 5.2.1.10-Manual pull located at path of egress. 5.4.5 Tanks accessible for service. 5.6.1.7 All penetrations sealed by UL listed device. 6.1.1.(2)- Installation conforms to NFPA 17A -2009. 6.1.1.(3)-All equipment listed by manufacturer. 6.1.1.(4)- Auxiliary devices acceptable to AHJ and manufacturer. 6.1.1.(5)- Balloon test per manufacturer. 6.1.1.(6) - Hazard protected (see plan). 6.3.1 Plans suitably dimensioned. 6.3.2 Plans detailed (see plan). 6.3.3 See piping allowances. 6.3.4 See floor plan. PIPING SCHEMATIC All piping is 3/8" black iron. Total pipe volume allowed is 1910 ml. Total pipe volume used is 24.5'x 37.5 ml per ft = 919 ml. Total pipe volume allowed first to last nozzle = 1125 ml. Total pipe volume first to last nozzle 21'x 37.5 ml = 788 ml. ■ N N U N cn Z CD U1 lf1 , X E Z u H F- 0000 Ua o v 00 Z Imn r ^ i in Z W E -j OawUO U U.J �(a Z Z W Z ~ =O ■ < (D U LU Q_ U m f- rj W Z ��rr L LU ¢ LL J � Z U� U U o U T Z M i -A U W -i t a lw- Cal O a CO ` ",IIIIIfffff D 2: •�} r `` -Yt. a •e C:) 1i^� '1 w , . KU ri y W (D U-1 Z Oo n F-11 LU H Z V) vI M .1-0 00 M CL 1-n LU (H� H U W C C MECHANICAL PLAN REVISIONS NUM DATE DESCRIPTION 2010 BUCHANAN P.E. CONSULTING. All information, drawings,and designs are not to be copied, reproduced, changed, transferred, or disclosed to any third party in any form or manner what so ever without the express written permission from Buchanan P.E. Consulting,Inc. PROJECT No.: DATE: 04 -01 -13 SCALE: DRAWN BY: RAB CHECKED BY: RAB SHEET M-5 5 OF 5