13-720-0110) IN o1 ll 0 W H Z 4 F d W co W v w NORTH ELEVATION HOOD SECTION MAKE-UP AIR 1/4" = 1' -0" ;TORE: ZOOF JOISTS FALLS f 22' -4" 1M.11 I , ree-IF!, 10 FT. MIN. RADIUS TO SUPPLY INLETS CLEAN OUT 40" MIN HEF -1 13x13 EQUIPMEK RAILS WOO, CMU WALL 8' -2" HOOD SECTION EXHAUST AIR 1/4" = V -0" SHEET CEILING 42" HIGH GUARD RAIL 13 x 13 PITCH UP MIN. 1/4' PER FT. CLEAN OUT 13x13 ROOF STRUCTURE: BUILT UP ROOF 18" MIN. MINERAL WOOL OVER 2x8 WOOD CEILING ANELS JOISTS 24" O.C. -- WOOD -- , �t 8" MINERAL WOOL PANELS �) H SQEN OR i _.. — WOOD STUD WALLS MINERAL WOOL WALL PANELS 80" 6" MIN. W APPLVNM SP V2�PSYSTE INSTALLED [N ACC WITH APPROVED BY L • ` • 1) SUPPLY AND EXHAUST FANS ARE INTERCONNECTED WITH A PILOT LIGHT IN THE KITCHEN AREA. 2) FIRE MODE REQUIRES THAT THE EXHAUST FAN CONTINUES TO OPERATE AND THE SUPPLY FAN STOPS AND ACTIVATES THE BUILDING FIRE ALARM SYSTEM. 3) HOOD EXHAUST FAN SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IS ACTIVATED. 4) FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEMS. COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE AREA. EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON DUCT. 5) FIRE SYSTEM SHALL BE CONNECTED TO THE BUILDING FIRE ALARM, IF ONE EXISTS. 6) FIRE SYSTEM PERMIT AND INSTALLATION BY OTHERS. 7) EXHAUST FAN MOTOR REQUIRES EXTERNAL OVERLOAD PROTECTION OR THE MOTOR WARRANTY IS VOID. 8) EXHAUST AND MAKE -UP AIR FANS SHALL BE PROVIDED WITH EXTERNAL DISCONNECT SWITCHES. 9) EXHAUST DUCTS SHALL BE 16 GAUGE GALVANIZED STEEL, ALL WELDED, AIR VELOCITY 1500 TO 2500 FPM, CLEAN OUTS AT 20 FOOT INTERVALS ON HORIZONTAL DUCTS, EXHAUST DUCT ELBOWS SHALL BE RADIUSED. 10) MAKE -UP AIR ` DUCT SHALL BE GALVANIZED STEEL, 24 GAUGE PITTSBURGH LOCK OR 26 GAUGE SNAPLOCK, AIR VELOCITY 1200 TO 1800 FPM. 11) GREASE EXHAUST FAN SHALL BE PROVIDED WITH A HINGING KIT, CHAIN STOP AND GREASE COLLECTION TROUGH. 12) FAN CURBS SHALL BE 18 GAUGE GALVANIZED STEEL, ALL WELDED. GREASE FAN EXHAUST CURBS SHALL BE A MINIMUM OF 18" HIGH. 13) MAKE -UP AIR FAN INTAKE SHALL BE A MINIMUM OF 10 FEET FROM SOURCES OF CONTAMINATED AIR, EXHAUST FANS, PLUMBING VENT STACKS, ETC. 14) EXHAUST FAN TERMINATIONS SHALL HAVE A 10 FOOT MINIMUM CLEARANCE FROM THE OUTLET TO ADJACENT BUILDINGS, PROPERTY LINES, GRADE LEVEL, COMBUSTIBLE CONSTRUCTION, OPERABLE DOORS AND WINDOWS, ELECTRICAL EQUIPMENT AND LINES AND ALL SUPPLY AIR INLETS. 15) ROOFTOP FANS SHALL BE LOCATED A MINIMUM OF 10 FEET FROM THE EDGE OF THE BUILDING OR A 42" HIGH GUARD SHALL BE INSTALLED. 16) PRIOR TO THE FINAL INSPECTION, THE RESTAURANT OWNER SHALL HAVE A PERFORMANCE TEST DONE SHOWING THE RATE OF AIR FLOW OF THE HOOD SYSTEM(S). 17) TYPE I AND II HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR, BY HEAT SENSORS OR OTHER APPROVED METHODS. FLORIDA MECHANICAL CODE: 507.2.1.1 & FUEL GAS CODE 505.1.1 18) A CAPTURE AND CONTAINMENT TEST SHALL BE PERFORMED BY THE PERMIT HOLDER. HOOD MAKEUP AIR, EXHAUST AIR, AND ALL AIR CONDITIONING FOR THE SPACE SHALL BE IN OPERATION. THE TEST SHALL BE VERIFIED VISUALLY BY OBSERVING SMOKE OR STEAM. 19) THESE MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING, FABRICATION OR INSTALLATION OF THE EQUIPMENT. 20) MIAMI -DADE MECHANICAL CODE COMPLIANCE NO LONGER REQUIRES WIND LOAD CALCULATIONS FOR ROOFTOP HOOD FANS, HURRICANE STRAPPING ON THE FANS OR A NOTICE OF ACCEPTANCE FOR THE FANS. THE DRAWING ONLY NEEDS TO SHOW AN ACCEPTABLE FASTENING METHOD FOR THE FANS TO WITHSTAND 170 MPH HURRICANE FORCE WINDS. INSTALLATION SHALL COMPLY WITH THE FLORIDA MECHANICAL CODE -2010 AND THE NATIONAL FIRE PROTECTION ASSOCIATION STANDARD 96 -2008. EXHAUST DUCT AIR VELOCITY CALCULATION: EXHAUST DUCT: 13x13 = 1.17 SQ. FT., FACE AREA. 2200 CFM / 1.17 = 1880 FPM. FLORIDA MECHANICAL CODE 2010 506.3.4 "AIR VELOCITY" 1500 TO 2500 FPM. HVAC DESIGN: (FOR HOOD SYSTEM) YES NO Duct Smoke Detector Q 0% a7 � ( Fire Damper(s) N o � o Smoke Damper(s) Z � Q V l Q � r-+ W � � Fire Rated Enclosure 0 U_ 0 U w Q Fire Rated Roof /Floor Ceiling Assembly .6ZZa ~ W z OLL ■ Q U U w m F- w Fire Stopping IL J � Smoke Control U M U o T lY) ■ N N N U Ol Z ° t11 Q 0% a7 � ( �/ X E Z �� N o � o 0 Z M a Zd' O o �' Z � Q V l Q � r-+ W � � Z 0 U_ 0 U w Q -j .6ZZa ~ W z OLL ■ Q U U w m F- w LU Z 2 Lu Q IL J � W Z U U M U o T lY) -, V w g� a � D Q� w � SEAL FY�F �' •ff�) d a. • T �ra � �'� ..iS F� tlillti`i W C.� LU Z H L O o� J � Q H z z� oC UP) m d- O 00 Cl- Ln W F__q (l F- U W 0 W CL MECHANICAL PLAN REVISIONS NUM DATE DESCRIPTION 2010 BUCHANAN P.E. CONSULTING. All information, drawings,and designs are not to be copied, reproduced, changed, transferred, or disclosed to any third party in any form or manner what so ever without the express written permission from Buchanan P.E. Consulting,Inc. PROJECT No.: DATE: 04 -01 -13 SCALE: DRAWN BY: RAB CHECKED BY: RAB SHEET 2 OF 5