Loading...
13-720-002r c� 3 0 rm ch N v w m C9 N N C3 M .0 v' Y N �4 n > L W x o:i =a T m X a J rn Q o U Z 4 JN "It W z z, 0-, U a Z Co T C L) U) CO W 1/2" Quik Seal grease Duct or Hood (Adapter Body) kExternal Surface) 1 1/8" - 1 1/4" Diameter Hole 0 Resistance VULCAN, CAL -STAY Temperature 1E269 (OR EQUAL) Detector 1/2" Quik Seal (Gasket) 1/2" Quik Seal (Nut) 1/2" Quik Seal (Lock Washer) HOOD HEAT SENSOR INSTALLATION 6 GAUGE EXHAUST )UCT ALL WELDED ELD DUCT ) BRACKET - 1/2 "x1- 1 -1/2" 1/8" STL ANGLE, kLL WELDED CRETE ANCHORS `--\/ `-' --CMU (BLOCK) WALL DUCT SUPPORT DETAIL NTS GUARD RAIL (PAINT TO MATCH EXITING STUCCO COLOR) 42" MIN. 1/4- TAPCONS W/ FENDER WASHER, • > AT EACH UPRIGHT. EXISTING • CONCRETE TIE -BEAM EXTEND RAILING A ►,. MINIMUM OF 30' BEYOND ;., EQUIPMENT, EACH SIDE. EXISTING EXTERIOR C.M.U. BLOCK WALL SAFETY GUARD DETAIL N T S EXHAUST FAN GENERAL NOTES: FMC: 507.2.1.1 OPERATION, AND GAS CODE: 505.1.1 TYPE I & II HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR. THE ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES, BY MEANS OF HEAT SENSORS OR BY MEANS OF OTHER APPROVED METHODS. UPON ACTIVATION OF THE FIRE SYSTEM: A. MAKE -UP AIR FAN(S) MUST SHUT DOWN. B. ALL ELECTRIC APPLIANCES AND OUTLETS UNDER THE HOOD MUST SHUT DOWN. C. EXHAUST FAN MUST CONTINUE TO RUN, OR TURN ON IF THE HOOD FAN SWITCH IS IN THE OFF POSITION. D. ALARM DEVICE (HORN & STROBE) MUST ACTIVATE. E. BUILDING FIRE ALARM (IF PRESENT) MUST ACTIVATE. ELECTRICAL: 1. (1) CONTACTOR, 1 PHASE, 20 AMP, 120 VOLT, WITH 120 VOLT COILS. 2. MAKE -UP AIR MOTOR, 0.75 HP, 115/1/60, 11.0 AMPS. 3. (2) CONTACTORS, 1 PHASE, 20 AMP, 240 VOLT, WITH 120 VOLT COILS. 4. EXHAUST MOTOR, 1.5 HP, 208/1/60, 10.2 AMPS 5. ALL WIRE THHN. HORN & STROBE THERMOSTAT IN EXHAUST HOOD SET ® 85' NEUTRAL ROOF STRUCTURE, BUILT -UP ROOF OVER WOOD DECK WITH 2x10 JOISTS 14x 1 xJ- STEEL ANGLE 5/16" BOLT & FENDER WASHER 1/2" DOUBLE NUTS 1/2" THREADED ROD FACTORY WELDED BRACKET HOOD 3/8" LAG BOLTS INTO JOISTS WOOD DECK r/9P 1 SAFETY GUARD DETAIL N T S MAKE -UP AIR FAN i CURB - 18GA GALV STL ALL WELDED, 4 CURB FLANGE / BUILT -UP ROOF' OVER (4) 5/16' BOLTS (3) #12 SMS J \, (AT CORNERS) EACH SIDE I ALTERNATE: MIN (4) 318 "x 4" LAG 580 LB SHEAR BOLTS INTO WOOD TRUSSES STRENGTH EA. CURB AND FAN MOUNTING DETAIL N T S 3/8' BOLTS THRU DECK 2 PER SIDE 830 LB - SHEAR STRENGTH EA. ALTERNATE: MIN (4) 3 /8 "x 4" LAG BOLTS INTO WOOD TRUSSES WOOD DECK 3' RAIL FLANGE SCREW ANGLE T❑ JOIST CLEAN OUT LL"1 40" MIN GREASE HEIGHT VARIES VIBRATI ❑N ISOLAT ❑RS 14 GA. GALV. STEEL EQP'T RAIL 'i" x 1j" STEEL ANGLE OR HEAVY DUTY UNISTRUT RAIL AND FAN MOUNTING DETAIL UTILITY VENT SET N T S COMBUSTIBLE MATERIAL ►�1 1 :ICI 1 -IN. NONCOMBUSTIBLE \ SPACER 22 GA SHEET,/ METAL WIRE MESH 1 -IN. MINERAL WOOL BAT. OR CERAMIC FIBER BLANKET ' f 319 ` 3" ' I REDUCTION OF CLEARANCE TO COMBUSTIBLES N T S N.F.P.A. 96 FIGURE A.4.2(g) WOOD DECK - - - -- WOOD JOIST : -- - - - --- - - -" 1 1/2 X 1 1/2 X 3/;6-- - - - -- STEEL ANGLE u ITm NAIMM ANMZ yr MA. ALL TNEAD NO CDOELTO TO MW .MDST 7NRMMi1 AICUMM MGM Neu ur WA WAVY DUTY MR AM VASHM - OE AMOK AND of KLOV HAN®m AMME ROD. M , AND VAS E" TO K VJ-PLM RT TNSTALLDRI mRRACTM NANGDR ANGLE Dt PRE-FLICH[D AT FACTORY HOOD HANGER INSTALLATION N T S AIR BALANCE SCHEDULE: HEF -1 - 2200 CFM HSF -1 + 2000 CFM NET - 200 CFM 1. Slight negative pressure to retain smoke and odors. 2. Negative pressure shall not exceed 0.02 inch water column. 3. The outside air from the air conditioning units shall be adjusted to compensate for other restaurant exhaust fans to maintain kitchen negative pressure between 0.0 and -0.02. WOOD JOIST YPSUM WALLBOARD I. AIR T❑ HOOD ERAL WOOL 2 GA. SHEET /IRE MESH N- COMBUST- SPACERS STUD WALL REDUCTION OF CLEARANCE TO COMBUSTIBLES N T S GA. GALV. -L ONTINUOUS EXTERNAL QUID TIGHT WELD. " FLANGE DUCT JOINT DETAIL NFPA 96 -08, 7.5.5.1 (c) N T S J " N , 0) Z ° Ln HOOD LIGHTS HEF -1 00 M L� NEUTRAL (71 00 O M � d' r o c p t- Ln ma MOTOR LL 3: E U= CU J z Z Q LU Z ~ = O In U CL m F- rj r---------- - - - -IJIGRD 1.5 HP o z W > Q ro HOOD W �LL ¢ w UL CONTACTOR BOX I 208/11/60 10.2 A SEAL A,� LIGHT CONTACTOR #1, 230V ELECTRIC PANEL tttttTtf7tt4��♦ LU SWITCH -� �, LL O C) H LU H z� Q L --J 00 W H 1-- 1-- U W I Ix CL COIL 1 PLAN REVISIONS NUM DATE PROVIDE 2 IN #12 Cu & 1 #12 Cu Grd 1/2" EMT CONDUIT VOLTS AC , MAKE -UP AIR FAN I 11120 JII I LL — — — -- J �... 20 AMP, 1 P BREAKER 0 2010 BUCHANAN P.E. CONSULTING. All Information, drawings,and designs are not to be copied, reproduced, changed, transferred, or disclosed to any third party In any form or manner what so ever without the express I I Buchanan P.E. Consuldng,Inc. PROJECT No.: DATE: 04 -01 -13 115 VOLT DRAWN BY: RAB CHECKED BY: RAB SHEET M -3 3 OF 5 PROVIDE 2 #12 Cu & 1 #12 Cu Grd CONTACTOR #2, 230V , EX aUff AIR FAN IN 1/2- EMT CONDUIT _ —�— rr ,� I FAN I L1 iT1 EXHAUST 20 AMP, 2P BREAKER I I COIL 2 208 VOLT , 1120 VOLTS AC I I L2 T2 FIRE SYSTEM Yr = -I I L — — — ._ J L --� MICRO- SWITCH c a� r -- I o HOOD FAN I SWITCH & I w CONTACTOR #3, 230V w CONTROL NC COMMON C — — — JPILOT LIGHT I w �- a" 2 � EXHAUST JUMPER — — — r� - - - -,� a- � w 15 AMP, 1P BREAKER I L1 T1 , 120 VOLT ' PROVIDE 2 #12 Cu L —NO II COIL 3 & 1 "# 12 N 1/2 EMT Cu Grd NORMN CONDUIT I 120 VOL"T2 II L2 I I L---------- - - - --J GENERAL NOTES: FMC: 507.2.1.1 OPERATION, AND GAS CODE: 505.1.1 TYPE I & II HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR. THE ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES, BY MEANS OF HEAT SENSORS OR BY MEANS OF OTHER APPROVED METHODS. UPON ACTIVATION OF THE FIRE SYSTEM: A. MAKE -UP AIR FAN(S) MUST SHUT DOWN. B. ALL ELECTRIC APPLIANCES AND OUTLETS UNDER THE HOOD MUST SHUT DOWN. C. EXHAUST FAN MUST CONTINUE TO RUN, OR TURN ON IF THE HOOD FAN SWITCH IS IN THE OFF POSITION. D. ALARM DEVICE (HORN & STROBE) MUST ACTIVATE. E. BUILDING FIRE ALARM (IF PRESENT) MUST ACTIVATE. ELECTRICAL: 1. (1) CONTACTOR, 1 PHASE, 20 AMP, 120 VOLT, WITH 120 VOLT COILS. 2. MAKE -UP AIR MOTOR, 0.75 HP, 115/1/60, 11.0 AMPS. 3. (2) CONTACTORS, 1 PHASE, 20 AMP, 240 VOLT, WITH 120 VOLT COILS. 4. EXHAUST MOTOR, 1.5 HP, 208/1/60, 10.2 AMPS 5. ALL WIRE THHN. HORN & STROBE THERMOSTAT IN EXHAUST HOOD SET ® 85' NEUTRAL ROOF STRUCTURE, BUILT -UP ROOF OVER WOOD DECK WITH 2x10 JOISTS 14x 1 xJ- STEEL ANGLE 5/16" BOLT & FENDER WASHER 1/2" DOUBLE NUTS 1/2" THREADED ROD FACTORY WELDED BRACKET HOOD 3/8" LAG BOLTS INTO JOISTS WOOD DECK r/9P 1 SAFETY GUARD DETAIL N T S MAKE -UP AIR FAN i CURB - 18GA GALV STL ALL WELDED, 4 CURB FLANGE / BUILT -UP ROOF' OVER (4) 5/16' BOLTS (3) #12 SMS J \, (AT CORNERS) EACH SIDE I ALTERNATE: MIN (4) 318 "x 4" LAG 580 LB SHEAR BOLTS INTO WOOD TRUSSES STRENGTH EA. CURB AND FAN MOUNTING DETAIL N T S 3/8' BOLTS THRU DECK 2 PER SIDE 830 LB - SHEAR STRENGTH EA. ALTERNATE: MIN (4) 3 /8 "x 4" LAG BOLTS INTO WOOD TRUSSES WOOD DECK 3' RAIL FLANGE SCREW ANGLE T❑ JOIST CLEAN OUT LL"1 40" MIN GREASE HEIGHT VARIES VIBRATI ❑N ISOLAT ❑RS 14 GA. GALV. STEEL EQP'T RAIL 'i" x 1j" STEEL ANGLE OR HEAVY DUTY UNISTRUT RAIL AND FAN MOUNTING DETAIL UTILITY VENT SET N T S COMBUSTIBLE MATERIAL ►�1 1 :ICI 1 -IN. NONCOMBUSTIBLE \ SPACER 22 GA SHEET,/ METAL WIRE MESH 1 -IN. MINERAL WOOL BAT. OR CERAMIC FIBER BLANKET ' f 319 ` 3" ' I REDUCTION OF CLEARANCE TO COMBUSTIBLES N T S N.F.P.A. 96 FIGURE A.4.2(g) WOOD DECK - - - -- WOOD JOIST : -- - - - --- - - -" 1 1/2 X 1 1/2 X 3/;6-- - - - -- STEEL ANGLE u ITm NAIMM ANMZ yr MA. ALL TNEAD NO CDOELTO TO MW .MDST 7NRMMi1 AICUMM MGM Neu ur WA WAVY DUTY MR AM VASHM - OE AMOK AND of KLOV HAN®m AMME ROD. M , AND VAS E" TO K VJ-PLM RT TNSTALLDRI mRRACTM NANGDR ANGLE Dt PRE-FLICH[D AT FACTORY HOOD HANGER INSTALLATION N T S AIR BALANCE SCHEDULE: HEF -1 - 2200 CFM HSF -1 + 2000 CFM NET - 200 CFM 1. Slight negative pressure to retain smoke and odors. 2. Negative pressure shall not exceed 0.02 inch water column. 3. The outside air from the air conditioning units shall be adjusted to compensate for other restaurant exhaust fans to maintain kitchen negative pressure between 0.0 and -0.02. WOOD JOIST YPSUM WALLBOARD I. AIR T❑ HOOD ERAL WOOL 2 GA. SHEET /IRE MESH N- COMBUST- SPACERS STUD WALL REDUCTION OF CLEARANCE TO COMBUSTIBLES N T S GA. GALV. -L ONTINUOUS EXTERNAL QUID TIGHT WELD. " FLANGE DUCT JOINT DETAIL NFPA 96 -08, 7.5.5.1 (c) N T S J " N , 0) Z ° Ln I�1 J r m Ch (V � = X E Z b L2 8 00 M L� .-� 4:1: o am (71 00 O M � d' r o c p t- Ln ma N �E Z w L- a. rn 0 LL 3: E U= CU J z Z Q LU Z ~ = O In U CL m F- rj W Z Q 2: LU Z [� G J � o z W > Q ro U Mr -i zM W �LL ¢ w M c' W °i a k SEAL A,� 4. w •-J= tttttTtf7tt4��♦ LU LU Z > -� LL O C) H LU H z� Q M 'Cr" O 00 W H 1-- 1-- U W I Ix CL MECHANICAL PLAN REVISIONS NUM DATE DESCRIPTION 2010 BUCHANAN P.E. CONSULTING. All Information, drawings,and designs are not to be copied, reproduced, changed, transferred, or disclosed to any third party In any form or manner what so ever without the express written permission from Buchanan P.E. Consuldng,Inc. PROJECT No.: DATE: 04 -01 -13 SCALE: DRAWN BY: RAB CHECKED BY: RAB SHEET M -3 3 OF 5