PL UMBING NO TES
1. DO NOT SCALE THE DRAWINGS CONSULT THE ARCHITECT'S AND
STRUCTURAL DRAWINGS FOR DIMENSIONS
2. CONSULT THE ARCHITECT'S DRAWINGS FOR ALL GRADE AND FINISH
FLOOR ELEVATIONS.
3, ALL GRAVITY LINES SIZED TO SLOPE 118" PER FOOT(1 14" FOR 2"
AND UNDER), UNLESS OTHERWISE NOTED.
4. ALL WORK SHALL COMPLY, WHETHER SO INDICATED ON THESE PLANS
OR NOT, WITH FBC PLUMBING , AS LOCALLY AMENDED.
5. POTABLE HOT AND COLD WATER PIPING SHALL BE COPPER OR CP✓C .
6, SANITARY WASTE, VENT, STORM DRAIN PIPING SHALL SEE SPECS.
PVC WITH SOLVENT WELDED JOINTS, WHERE PERMITTED BY CODE AND LANLORD, TENANT
NO PVC ALLOWED IN RETURN AIR CEILING., FOLLOW BUILDING STANDARDS.
7. CONFIRM SIZE, LOCATION AND ELEVATION OF ALL EXISTING
UTILITIES PRIOR TO INSTALLING ANY PIPE.
8. COORDINATE WITH ALL TRADES TO PREVENT ANY CONFLICTS.
9. ALL FLOOR DRAINS SHALL HAVE RESEAL FITTINGS.
PLUMBING LEGEND
SYMBOL DESCRIPTION
PLUMBING SPEUIFIUA LIONS
3.01 GENERAL.
A. SEE ARCHITECTURAL DRAWINGS FOR ANY ADDITIONAL REQUIREMENTS.
B. THE CONTRACTOR BEFORE COMMENCING ANY WORK, HALL VERIFY ALL GOVERNING DIMENSIONS
AT THE SITE AND EXAMINE ADJOINING WOK ON WHICH ITS WORK WILL BE DEPENDENT
REPORT ANY CONFLICTS OR DISCREPANCIES TO. THE ARCHITECT,
C. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WITH THE OWNER AT LEAST 48 HOURS IN
ADVANCE. SHUTDOWN TIME WILL BE KEPT TO A MINIMUM AND PERFORMED WHEN CONVENIENT
TO THE OWNED;'.
D. FURNISH THE OWNER'S REPRESENTATIVE WTTH A WRITTEN GUARANTEE STATING THAT ALL
MATERIALS AND INSTALLATION ARE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND
ARE FULLY GUARANTEED FOR ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE
WORK, AND THAT ALL WORK WHICH PROVES DEFECTIVE DURING THAT TIME SHALL BE
REPLACED AT NO COST TO THE OWNER.
E. WITHIN THIRTY (30) DAYS OF CONTRACT AWARD, THE CONTRACTOR SHALL SUBMIT FOR
REVIEW TO THE ARCHITECT ALL DEVICES TO BE USED IN THE WORK. SUBMITTALS SHALL
INCLUDE PIPE FITTINGS, HANGERS AND SUPPORTS, INSULATION, FIXTURES AND RELATED
EQUIPMENT
3.02 PRODUCT
A, PIPE AND F177-INGS
1. DOMESTIC COLD AND HOT WATER PIPING SHALL BE TYPE -L HARD DRAWN COPPER
TUBING FOR ASTM B -88 AND FEDERAL SPECIFICATION WWT -799. FITTINGS SHALL BE
SOLDER JOINT COPPER FITTINGS PER ANSI B76.18 OR B16.22. JOINTS SHALL BE MADE
WITH LEAD FREE SOLDER. 9515 SOLDER SILVER SOLDER OR PER PLUMBING NOTE 1'5.
2. WASTE PIPING SHALL BE TYPE DWV COPPER PER ASIT 6306 AND ANSI H23.6 OR
NO -HUB CAST IRON PER CISPI 3O1 AND 310. FITTINGS SHALL BE TYPE DWV SOLDER JOINT
PER ANSI B129 OR B16.23 OR NO -HUB CAST IRON FITTINGS PER CISPI 301 ABD 310.
3
B. VALVES
1, GATE VALVES SHALL BE MILWAUKEE FIGURE 1149, 125 PSI, SWEAT CONNECTION"
2. BALL VALVE 125 LB.. AS MANUFACTURED BY JOMAR, MILWALKEE, OR WATTS.
C. PIPE INSULATION SHALL BE 1 -1/2 ° LB DENSITY FIBERGLASS R ASTM C335 WITH
ALL SERVICE JACKET INSULATION SHALL COMPLY WITH NFPA 255 AND ASTM E84 WITH A
MAXIMUM FLAME SPREAD OF 25 AND MAXIMUM SMOKE DEVELOPED OF 50. PROVIDED PRE -
MOLDED FITTINGS COVERS EQUAL TO STARR DAVIS. INSULATION MANUFACTURER SHALL BE
MANVILLE, CERTIFIED OR OWENS- CORINING
D. FLOOR DRAINS, CLEAN OUTS, TRAP PRIMERS, HOSE BIBBS AND BACK FLOW PREVENTERS.- SEE
SCHEDULE THIS DRAWING.
E. AIR ADMITTANCE VALVE.- MAGIC VENT MICRO MODEL NO. 97400
3,03 EXECUTION
A. PROVIDE ALL WORK, EQUIPMENT AND MATERIALS INDICATED
B. ALL PIPE SHALL BE INSTALLED ABOVE CEILINGS, INSIDE WALLS OR IN CONCEALED SPACES,
C. DISINFECTING OF POTABLE WATER SHALL BE PERFORMED IN ACCORDANCE WITH THE LOCAL
AUTHORITY HAVING JURISDICTION.
D. TEST WASTE AND WATER UNDER ACTUAL OPERATING CONDITIONS. REPAIR LEADS AND
RETURN TO SERVICE. TEST WASTE PIPING AT 15 FEET OF HFAD FOR 24 HOURS. TEST WATER
Pl "1G AT 125 PSI FOR 2 HOURS. MAKE REPAIRS WITH NEW MATERIALS. REPLACE LEAK /NC
MATERIALS, DO NOT REPAIR BY PATCHING.
E. PROVIDE DOMESTIC WATER BACK FLOW PREVENTERS AT ALL BEVERAGE DISPENSER, ICE MAKERS
OR DEVICES REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. BACK FLOW PREVENTERS
SHALL BE APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
G. PROVIDE DIELECTRIC COUPLINGS AT ALL FERROUS TO NONFERROUS PIPE CONNECTIONS
AND FL4AIC'r UNION ISOLATING JOINTS TO PREVENT ANY ELECTRONIC ACTION BETWEEN
DISSIMILAR METALS.
-
COLD WATER PIPING
EQUIPMENT
..__
ABBREVIA,1 NS
LOCATION
A. F, F.
ABOVE FINISHED FLOOR
LOCATE FLOOR DRAINS WHERE SHOWN ON DIMENSIONED ARCHITEC-
B.T.U. ' '
BRITISH THERMAL UNITS
TURAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR DRAIN,
C.B.
CATCH BAS/N..
MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE
C.O.
CLEAN OUT '
TRAFFIC.
CONC,
CONCRETE '
r
CONN.
CONNECT OR CONNECTION;
r <,
C. V
:CHECK VALVE.. , ..
TG SET DRAIN BODY IN PLACE AND POUR AROUND IT RECESS TOP OF
C. W.
COLD 'WA'TER
FLOOR DRAIN 1/2"' BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT.
DN..
DOWN ,
WALL _ _.... - -- FLOW TO
._.- - ".
COLD WATER SUPPLY _ FIXTURE
ELEV, -
ELEVATION
KARP
EXIST,
EXISTING
ACCESS
F.C.O.
FLOOR CLEAN OUT
I BACK FLOW PREVENTS
F.D.
FLOOR DRAIN
SD
F.H.
FIRE HYDRANT
F.S.
FLOOR SINK
FS.
FLOW SWITCH
G.
GAS (L P.: t� pR NATURAL
{ C ��4' 9 ��
�-
eP1Y
T° L G. W° H. TANK LESS `iGAS - WATEf . HEATER
BREAKER
G. V.
GATE VALVE
. - -.. -- PROVIDE WYE SPUTTER WALL
H.B.
'HOSE BIBB
WITH DISTRIBUTOR FOR FLOOR SINK OR DRAIN SEE
H. W.
;HOT "WATER
MULTIPLE TRAP PRIMER / PLUMBING FIXTURE
H. W R,
HOT WATER RETURN PIPING
APPLICATION. FOLLOW i SCHEDULE FOR SPEC.
H. W. S.
HOT WATER SUPPLY PIPING-
s
H. W C,
HANDICAP WATER CLOSET
H. W R
HOT WATER RETURN
INV
IIVI%ER,,
NG COLLAR AND
ING CO LAC AND
SEEPAGE
LAV,
LAVATORY pp t
HOSE BIBB WIVACUUM BREAKER
L, P.
LIgU/F q, PROPANE
M.B.H,
'MILLION "'°BT0"PER "1WR
& SHUT-OFF VALVE
M.H.
MAN HOLE
CLEAN OUT
MTD.
MOUNTED
UNION
0.S & Y.
OUTSIDE SCREW AND YOKE ";VALVE
P &T ` ;
; PRESSURE, AND TEMPERATURE
P.I V
POST, !NDICA "TING VALVE
(SEE FLOOR PLANS). - - - - --
�'�- --
PRESSURE & TEMPERATURE RELIEF VALVE
P.R V
PRESSURE, REDUCING VALVE
' R. D.
ROOF' DRAIN
PIPING DOWN
R. W,
RAIN, WATER LEADER
S.D.
STORM DRAIN
PIPING UP
` S. S.
SANITARY SEWER
SK
SINK
TS -
TAMPER SWITCH
UR.
'URINAL , °
V.
VENT °
VB,
VACUUM . BREAKER:
V.B.
VALVE BOX
VTR.
VENT . THRU ROOF '
WATER CLOSET
W. M.
WATER METER
PLUMBING LEGEND
SYMBOL DESCRIPTION
PLUMBING SPEUIFIUA LIONS
3.01 GENERAL.
A. SEE ARCHITECTURAL DRAWINGS FOR ANY ADDITIONAL REQUIREMENTS.
B. THE CONTRACTOR BEFORE COMMENCING ANY WORK, HALL VERIFY ALL GOVERNING DIMENSIONS
AT THE SITE AND EXAMINE ADJOINING WOK ON WHICH ITS WORK WILL BE DEPENDENT
REPORT ANY CONFLICTS OR DISCREPANCIES TO. THE ARCHITECT,
C. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WITH THE OWNER AT LEAST 48 HOURS IN
ADVANCE. SHUTDOWN TIME WILL BE KEPT TO A MINIMUM AND PERFORMED WHEN CONVENIENT
TO THE OWNED;'.
D. FURNISH THE OWNER'S REPRESENTATIVE WTTH A WRITTEN GUARANTEE STATING THAT ALL
MATERIALS AND INSTALLATION ARE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND
ARE FULLY GUARANTEED FOR ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE
WORK, AND THAT ALL WORK WHICH PROVES DEFECTIVE DURING THAT TIME SHALL BE
REPLACED AT NO COST TO THE OWNER.
E. WITHIN THIRTY (30) DAYS OF CONTRACT AWARD, THE CONTRACTOR SHALL SUBMIT FOR
REVIEW TO THE ARCHITECT ALL DEVICES TO BE USED IN THE WORK. SUBMITTALS SHALL
INCLUDE PIPE FITTINGS, HANGERS AND SUPPORTS, INSULATION, FIXTURES AND RELATED
EQUIPMENT
3.02 PRODUCT
A, PIPE AND F177-INGS
1. DOMESTIC COLD AND HOT WATER PIPING SHALL BE TYPE -L HARD DRAWN COPPER
TUBING FOR ASTM B -88 AND FEDERAL SPECIFICATION WWT -799. FITTINGS SHALL BE
SOLDER JOINT COPPER FITTINGS PER ANSI B76.18 OR B16.22. JOINTS SHALL BE MADE
WITH LEAD FREE SOLDER. 9515 SOLDER SILVER SOLDER OR PER PLUMBING NOTE 1'5.
2. WASTE PIPING SHALL BE TYPE DWV COPPER PER ASIT 6306 AND ANSI H23.6 OR
NO -HUB CAST IRON PER CISPI 3O1 AND 310. FITTINGS SHALL BE TYPE DWV SOLDER JOINT
PER ANSI B129 OR B16.23 OR NO -HUB CAST IRON FITTINGS PER CISPI 301 ABD 310.
3
B. VALVES
1, GATE VALVES SHALL BE MILWAUKEE FIGURE 1149, 125 PSI, SWEAT CONNECTION"
2. BALL VALVE 125 LB.. AS MANUFACTURED BY JOMAR, MILWALKEE, OR WATTS.
C. PIPE INSULATION SHALL BE 1 -1/2 ° LB DENSITY FIBERGLASS R ASTM C335 WITH
ALL SERVICE JACKET INSULATION SHALL COMPLY WITH NFPA 255 AND ASTM E84 WITH A
MAXIMUM FLAME SPREAD OF 25 AND MAXIMUM SMOKE DEVELOPED OF 50. PROVIDED PRE -
MOLDED FITTINGS COVERS EQUAL TO STARR DAVIS. INSULATION MANUFACTURER SHALL BE
MANVILLE, CERTIFIED OR OWENS- CORINING
D. FLOOR DRAINS, CLEAN OUTS, TRAP PRIMERS, HOSE BIBBS AND BACK FLOW PREVENTERS.- SEE
SCHEDULE THIS DRAWING.
E. AIR ADMITTANCE VALVE.- MAGIC VENT MICRO MODEL NO. 97400
3,03 EXECUTION
A. PROVIDE ALL WORK, EQUIPMENT AND MATERIALS INDICATED
B. ALL PIPE SHALL BE INSTALLED ABOVE CEILINGS, INSIDE WALLS OR IN CONCEALED SPACES,
C. DISINFECTING OF POTABLE WATER SHALL BE PERFORMED IN ACCORDANCE WITH THE LOCAL
AUTHORITY HAVING JURISDICTION.
D. TEST WASTE AND WATER UNDER ACTUAL OPERATING CONDITIONS. REPAIR LEADS AND
RETURN TO SERVICE. TEST WASTE PIPING AT 15 FEET OF HFAD FOR 24 HOURS. TEST WATER
Pl "1G AT 125 PSI FOR 2 HOURS. MAKE REPAIRS WITH NEW MATERIALS. REPLACE LEAK /NC
MATERIALS, DO NOT REPAIR BY PATCHING.
E. PROVIDE DOMESTIC WATER BACK FLOW PREVENTERS AT ALL BEVERAGE DISPENSER, ICE MAKERS
OR DEVICES REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. BACK FLOW PREVENTERS
SHALL BE APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
G. PROVIDE DIELECTRIC COUPLINGS AT ALL FERROUS TO NONFERROUS PIPE CONNECTIONS
AND FL4AIC'r UNION ISOLATING JOINTS TO PREVENT ANY ELECTRONIC ACTION BETWEEN
DISSIMILAR METALS.
-
COLD WATER PIPING
EQUIPMENT
- - - - - -
HOT WATER PIPING
LOCATION
FD
FLOOR DRAIN
LOCATE FLOOR DRAINS WHERE SHOWN ON DIMENSIONED ARCHITEC-
WITH TRAP PRIMER
TOILETS /WORK AREAS
TURAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR DRAIN,
e -mail: tag- dbi0togdbi.com
MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE
FS
TRAFFIC.
G
GAS PIPING
SHFLOOR S1LAB ON GRADE PROVIDE BACKFILL PER PECIFICATIONS•
CD
CONDENSATE DRAIN PIPING
IF CONCRETE FLOOR 1S NOT EXISTING, SET DRAIN IN PLACE AND POUR
AROUND IT. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL
S.S. COVE AND SCREW
INTERIOR
TG SET DRAIN BODY IN PLACE AND POUR AROUND IT RECESS TOP OF
PT
PRESSURE & TEMPERATURE RELIEF PIPING
FLOOR DRAIN 1/2"' BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT.
EXTERIOR
SANITARY WASTE & SOIL PIPING
WALL _ _.... - -- FLOW TO
._.- - ".
COLD WATER SUPPLY _ FIXTURE
ZURN MODEL Z -1022
INSTALL WITH ACCESS
KARP
- - - - - - -
VENT PIPING
ACCESS
AUTOMATIC TRAP DOOR
I BACK FLOW PREVENTS
WATTS NO 9BD
PRIMER VALVE. SIOUX
SD
STORM DRAIN PIPING
CHIEF 695 SERIES. -- CHROME
ESCUTCHEON
PLATE
VACUUM
�-
GATE VALVE
BREAKER
. - -.. -- PROVIDE WYE SPUTTER WALL
CHECK VALVE
WITH DISTRIBUTOR FOR FLOOR SINK OR DRAIN SEE
MULTIPLE TRAP PRIMER / PLUMBING FIXTURE
APPLICATION. FOLLOW i SCHEDULE FOR SPEC.
AUTOMATIC GAS VALVE
MANUFACTURES CONCRETE FLOOR
INSTRUCTIONS. ,
MANUAL GAS VALVE
DIRT LEG
NG COLLAR AND
ING CO LAC AND
SEEPAGE
PAN
-
HOSE BIBB WIVACUUM BREAKER
MAXIMUM TAILPIECE
LENGTH IS 2 FEET
& SHUT-OFF VALVE
CLEAN OUT
UNION
UNLIMITED DISTANCE WHERE ENLARGED WASTE
LINE IS USED AN A COMBINATION DRAIN AND
VENT SYSTEM PER FBC PLUMBING 2004
SECTION 912. OTHERWISE VENT PER CHAPTER 9.
(SEE FLOOR PLANS). - - - - --
�'�- --
PRESSURE & TEMPERATURE RELIEF VALVE
SLOPE WASTE IN ACCORDANCE WITH
TABLE 704.1 F8CP 2004- (CHART, THIS SHEET). -
(-
PIPING DOWN
F.D. & TRAP RESEAL DETAIL
NO SCALE
-
PIPING UP
PRIME TRAP PRIMER,
YR. SMITH, OR EQUAL
JA SHALL BE AN
ACCEPTABLE TRAP PRIMER ALTERNATIVE.
DRAIN SCHEDULE
MARK
EQUIPMENT
MANUFACTURER AND MODEL
REMARKS
LOCATION
FD
FLOOR DRAIN
ZURN MODEL Z -415 'B" STRAINS
WITH TRAP PRIMER
TOILETS /WORK AREAS
e -mail: tag- dbi0togdbi.com
,
FS
FLOOR SINK
ZURN MODEL Z- 1820 -1 LESS GR
091SE LIP 1 " A. F. F.
WORK AREAS
CD -1
CLEAN OUT
ZURN MODEL ZS -1400
S.S. COVE AND SCREW
INTERIOR
CD -2
CLEAN OUT
ZURN MODEL Z -1440
PLUG TYPE
EXTERIOR
TP
TRAP PRIMER
ZURN MODEL Z -1022
INSTALL WITH ACCESS
TOILETS /WORK AREAS
written consent of The Architects Group, Inc.
BFP
I BACK FLOW PREVENTS
WATTS NO 9BD
ITEMS 81 9,10,11 OF SPECS
SODA AREA
NOTE- ALL FIXTUREC SHALL i IFET HANDICAP REQUIREMENTS
MAIL) 8T H 1.7. rl rl✓ 3 vFr't.H-
SIHOUK ARRESTOR SCHEDULE
P.D.I. DESIGNATION MANUF. & MODEL FIXTURE UNITS CONNECTION
A SIOUX CHIEF 652 -A 1 -11 112"
B SIOUX CHIEF 653 -B 12 -32 314"
C SIOUX CHIEF 654 -C 33 -60 1 "
SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO
ACCESS DOOR REQUIRED, CONFORMS TO ANSI /ASSE 1010 STANDARDS.
DRAINAGE PIPE MIN. SLOPE
SIZE (inches) MINIMUM SLOPE (inch per foot)
2 -112 or less 114
3 to 6 1/8
8 or larger 1116
TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2007
PL UMBING FIXTURE NOTES
FIXTURES SHALL BE PER FBCP 604.4 - MIAMI -DADE ORD. SEC. 8 -31
WATER FLOW RESTRICTIONS ADOPTED BY MIAMI -DADE COUNTY WATER AND SEWER.
4.1 PLUMBING FIXTURES
4.1.1 TOILETS INSTALLED SHALL BE HIGH EFFICIENCY TOILET (HET) MODELS RATED AND
TESTED AT A MAXIMUM AVERAGE FLUSH VOLUME OF 1.28 GALLONS PER FLUSH (GPF) AND BE
CERTIFIED BY UNITED STATES
4.1.2 URINALS INSTALLED SHALL BE ZERO WATER CONSUMPTION (WATERLESS URINAL) OR HAVE
A MAXIMUM RATED FLOW OF 0.5 GPF OR LESS
4.1.3 LAVATORY FAUCETS
4,1.3.1 THE MAXIMUM FLOW RATE OF THE LAVATORY FAUCET SHALL NOT EXCEED 0.5 GPM AT
60 PSI AT THE INLET, WHEN WATER? IS FLOWING.
4.1.3.2 MECHANICAL METER AND OR ELECTRONIC SENSOR CONTROLS SHALL BE INSTALLED ON
HAND WASHING FAUCETS IN PUBLIC RESTROOMS.
'.4
8000 NW 7 Street, Suite 101
Miami, Florida 33126'
T. 3 0 5- 7 4 0- 0 1 5
F. 305 - 740 -01 58,.
e -mail: tag- dbi0togdbi.com
,
corporate license AAC 002228
Copyright Notice: These drawings, designs and
ideas are the property of The Architects Group, Inc, ,
and are protected under the copyright laws' ,
... rg.
Florida. No part thereof shall be copied, or used in
connection with any work other than for the specific
project for which they have been prepared without
written consent of The Architects Group, Inc.