Loading...
10-1131-042a Q 2 F- O 2 Q D 2 (!J W LL I \ V. I \ / 2 / r \ r \ \ GREASE INTERCEPTOR I /' CONNECT TO EXISTING 2" VENT/ VTR (FIELD VERIFY EXACT LOCATION) l v' 2 "V. / AV \ \ I \ \ SEE PLAN FOR SPECS 1 / / 3" LAV RUN @45' G• FLOW FITTING WITH I" VENT TERMINATE PER MFGR. N S NOTE.- RIM OF MOP RECEPTOR SHALL 2 '@ BE A MIN, OF 2" BELOW BOTTOM OF �4 3 COMP, SINK. C.Q r @1�8 11dF� NOTE: CONTRACTOR SHALL LOCATE EXISTING SANITARY LINE AND VERIFY SIZE. EXACT LOCATION, DIRECTION OF FLOW, REQUIRED INVERT ELEVATION FOR NEW CONNECTION BEFORE ANY WORK IS DONE. WORK DONE WITHOUT VERIFICATION SHALL BE THE SOLE RESPONSIBILITY OF THE PLUMBING CONTRACTOR AND CONTRACTOR SHALL NOT BE COMPENSATED FOR ANY MODIFICATION REQUIRED DUE TO FAILURE OF NOT HAVING DONE FIELD VERIFICATION OF REQUIRED CONNECTION POINTS (THIS IS TYPICAL OF ALL UTILITIES) �kIST�N SAN PROVIDE P —TRAP RE —SEAL FOR ALL F.D. 'S AND F.S. WITHOUT I.W. DISCHARGE. I I SANITARY PIPING DIAGRAM 1,2„ NO SCALE / I i LA V � O WC ' �Q PROVIDE NEW AMTROL ST -5 2 GAL. THERM— X —TROL RESTOR k /2'° jC�VS EXPANSION TANK H.S. JI NOTE. - TITAN SCR -2 N -120 �`�, 3��'' �'/ ALL EQUIPMENT WITH CWS TANKLESS WATER HEATER \ I ' — �� SHALL BE FED VIA BACKFLOW PREVENTER I PROVIDE TEMPERING N��JS WA TER PIPING DlA GRA M VALVE & SET FOR 110'F. FOR H. S. & LA V. \ i l H eFP �1 I I I / N \� 2N 3, CQMp sk NOTE, 3 —COMP. SK. & M.R. ARE TO BE PROVIDED WITH I40'F. HWS NO SCALE I. L.A. L. Leo Goi�si A, 1X521" � )INIAN i aona�11ff t .phoflff 12 -1 -10 project # 1070.00 Lebo `Assoc; Inc. 33187 au , t , o ";,��_: sT 9 14 seal: Ismael Leon` %E., L #'40168 8000 NW 7 Street, Suite 101 Miami, Florida 33126 T. 3 0 5— 7 4 0— 0 1 5 0 F_ 3 0 5— 7 4 0— 0 1 5 8 e —mail_ tag— dbiatagdbi.com corporate license AAC 002228 Copyright Notice: These drawings, designs and ideas are the property of The Architects Group, Inc. and are protected under the copyright laws of Florida: No part thereof shall be copied, or used in connection with any work other than for the specific project for which they have been prepared without written consent of The Architects Group, Inc. J J ■■ U) ) O W W�Ww <2 Q <lrc� rJ w L T� << LL U) DAZE: 1 1 / 17/ 10 JOB NO: 1018 -01 DRAWN: JI CHECKED: P 17 REVISIONS: Pedro P. Ramos, A.I.A. FL. Lic. 10590 S —I EET TITLE: PLUMBING RISERS SHEET NUMKR: P -2 W W�Ww z rJ r L << LL U) L) D Z DAZE: 1 1 / 17/ 10 JOB NO: 1018 -01 DRAWN: JI CHECKED: P 17 REVISIONS: Pedro P. Ramos, A.I.A. FL. Lic. 10590 S —I EET TITLE: PLUMBING RISERS SHEET NUMKR: P -2 W D .00 ILL Z U) W 0 0 �-- W D r U— `C u \0 F— O z tl ZV z �= W" r O C W = P _ z ) U) DAZE: 1 1 / 17/ 10 JOB NO: 1018 -01 DRAWN: JI CHECKED: P 17 REVISIONS: Pedro P. Ramos, A.I.A. FL. Lic. 10590 S —I EET TITLE: PLUMBING RISERS SHEET NUMKR: P -2