10-1131-035MINIMUM REQUIRED (U.N.O.) RETURN AIR DUCT SIZES RETURN AIR DUCT (N SIDE WALL GRILLES 80 CFM TRANSFER GRILLS SUPPLY DUCT DIAMETER AR EA OF SUPPLY DUCT IN SQ. INCHES AR EA OF SUPPLY DUCTX 1.5 R /ADUC>• DIAMETER WITHOUT 1" UNDERCUT DOOR R /ADUCT DIAMETER WITHOUT UNDER CUT DOOR 110 CFM ROOM SUPPLY CFM SQ. INS FREE AREA REQUIRED PLUS UC DOOR SQ.INS FREE AREA REQUIRED PLUS UC DOOR 4 13 20 5 8 i ", 3.` , 40 20 14X10 5 _ 20 30 7 9 360 CFM 60 30 14X10 6 28 42 8 10'. 18X12 100 50 14X10 7 38 57 9 11 LL 150 75 12X12 8 50 75 10 12 z 250 125 14X12 9 64 96 12 13 �� 300 150 14X12 10 78 117 13 14 350 175 14X12 11 95 143 14 15 0 250 14X14 12 113 170 15 16 600 300 16X14 12 133 200 16 18'. 7501 375 16X16 14 231 18 19. 9001 450 16X16 15 _154 177 266 19 20�.{ 1100 550 18X18 16 201 302 20 21 1250 625 18X18 17 227 341 21 22 1500 750 20X18 18 _ 254 381 23 23 _a 1700 850 20X18 19 283 425 24 25 Q , , ,' 2000 1 000 22X20 201 314 471 25 26 2250 1125 22X26 CEILING DIFFUSER CAPACITY (N SIDE WALL GRILLES 80 CFM W 6X6 NE ' -170 CFM I 12X6 110 CFM FL. Lic. 10590 6X8,:'' W 240 CFM LL 12X8 150 CFM V 8X8 300 CFM z 12X10 200 CFM 8X10;, W 360 CFM cn LLJ L�J LiJ 12X12 250 CFM 10X10 I'M CFM w 18X12 370 CFM O 12X12 800 CFM 18X18 500 CFM LL 14X14 , .,', 700 CFM LL 24X12 LL_ z 1100 CFM U W 24X18 UI J_ IX� Ci 1400 CFM 24X24 SUPPLY DUCT 1 -112" GALV.- n 4' -0" 0 1C. ANGLE UNDER NOTE• R/A BALANCE ACHIEVED BY INCREASING R/A DUCT TO MIN. 1.5 x S/A PER FBC (M) 601.4 EXEPTION #1 :X. UL 181 CT DUCT CONNECTIONS TO CEILING DIFFUSERS DETAIL LJ _ SPRING ISOLATORS R/A FILTER SECTION A.H. U. HANGER DETAILS SCALE. N.T.S. NEOPRENE VIBRATION PADS UNION (TM) CAP � 1- 5/8'X1 - 5/8"X12 CHANNEL SUPPORT P- TRAP (3" WATER SEAL) I H.P. - HANGER SUPPORT DET 314" MIN, AUX. DRAIN — NTS TERMINATE ABOVE SK. NOTE AUXILIARY DRAIN INSULATE DRAIN PAN WITH 112" THICK PAN (GALVANIZED FIBERGLASS BLANKET WITH VAPOR SHEET j8 E,V BARRIER OR SHEET FOAMED PLASTIC 1 -1/2 U. x i" MIN. LARGER INSULATION WITH APPROVED FIRE 0.0276' AHU. SIZE. R477NG ON OUTSIDE SURFACE ONLY WILEV G ET TOR MIL. W /LEI�EL DETECTOR FOR AUTOMATIC SHUT DOWN IF UNABLE TO DRAIN TO SAFE LOCA77ON A/C UNIT DRAIN PAN AND CONDENSATE TRAP DETAIL NTS CO. PLUG Tcc- i — I A.H.U. �\ IN CONN. TYP. AHU CONDENSATE DRAIN CONNECTION DETAIL SCALE N. TS. SET DAMPER FOR 100 CFM 0/A INTAKE SUPPORT FROM STRUCTURE FRAMING LE CONNECTION S/A DUCT 112-0 THREADED RODS 0 EACH CORNER CONC. SLAB NEW AHU #2 TWO 2" WIDE 20 GAUGE HURRICANE GALVANIZED METAL STRAPS ANCHORED TO UNIT AND FRAME TO WITHSTAND 146 MPH WINDS AND TO COMPLY WITH F£MA DAVE COUNTY APPROVED C. U. STANp N.O.A. # 07- 0516.04 3/8" WEDGE C. U. MOUNTING DET NO SCALE MMM AIR COOLED AIRDYNE GLYCO —PACK CHILLER UNIT NOTE.' SET NEW C. U. ON DADE ... ..... . .......... . .... ...... COUNTY APPROVED META __........ .., __ _ __._.. STAND, ANCHORED TO CONC. SLAB I NEW C. U. #2 I MIN. , NEW TOILET EXHAUST o WALL CAP WITH SCREEN - i & BACKDRAFT DAMPER am 1 -118" CHILLED WATER SUPPLY & RETURN (LINES TO BE INSULATED) NOTE: 44 r R/A BALANCE ACHIEVED Tt'_ BY INCREASING R/A DUCT TO MIN. 1.5 x S/A 7 .. He PER FBC (M) 601.4 EXEMPTION #1 12x1._.__ 2---4W 350 1 CFM Ni)RTI i FLOOR PLAN OUTSIDE AIR CALCULATIONS CALCULATIONS ARE BASE ON ASHRAE 62.1 -2004 DEFAULT VALUES DINING AREA = 30 PERSONS (30 x 10 = 300 CFM MINIMUM) PROVIDED EXISTNG AHU — 200 CFM NEW AHU — 100 CFM TOTAL = 300 CFM AS REQUIRED KEY LEGEND: (D EXISTING C. U. MODEL # GIBSON JSBA -042 TO REMAIN Q EXISTING AHU MODEL # GIBSON ( -042) TO REMAIN ( VERIFY CONDITION ) 1400 CFM CAPACITY 5 KW HEATER — SUBJECT TO FIELD VERIFICATION 5 KW HEATER — SUBJECT TO FIELD VERIFICATION 42,000 BTU /hr TOTAL CAPACITY Q EXISTING S/A DUCTWORK TO REMAIN ® EXISTING CEILING DIFFUSER ( 350 CFM ) TO REMAIN EXISTING CEILING DIFFUSER ( 350 CFM ) TO RELOCATED © EXISTING E.F. AND RELATED DUCTWORK TO BE REMOVED 0 EXISTING S/W RETURN AIR REGISTER TO BE REMOVED. ® PROVIDE NEW 24x24 CEILING R/A GRILLE MODULE WITH NEW R/A DUCT AND CONNECT TO EXISTING, REFER TO ITEM # 7 ABOVE ® EXISTING 314" C.D. TO DRYWELL REMAINS y 0 CONNECT TO EXISTING 314" C.D. WITH NEW THE ENTIRE LINE TO BE INSULATED WITH 314" ARMAFLEX 11 NEW AHU AND DUCT WORK EXTEND CONDENSER WATER S & R TO SOFT SERVE MACHINES DROP IN PARTITION 8000 NW 7 Street, Suite 101 Miami, Florida 33126 T. 3 0 5- 7 4 0- 0 1 5 0 F. 305- 740 -01 58 e —mail: tag— dbiOtagdbi.com corporate license AAC 002228 Copyright Notice: These drawings, designs and ideas are the property of The Architects Group, Inc. and are protected under the copyright laws of Florida. No part thereof shall be copied, or used in connection with any work other than for the specific project for which they have been prepared without written consent of The Architects Group, Inc. -r— (N I.L.A. project # 1070.00 W W I z z I I. Leon & Assoc., Inc. FL. Lic. 10590 W W HEFT - FATE: LL MIAMI, FLORIDA 33187 V CA # 6577 z z r_ I LLJ nLn cn cn W W cn LLJ L�J LiJ z z c� I' >: " "` :c u- w _L1 O O ry DATE: I I/ I _// 10 JOB NO: 1018 -01 DRAWN: JI CHECKED: PR REVISIONS: 12 -1 -10 I.L.A. project # 1070.00 Lu ' I z =� Pedro P. Ramos, A.I.A. I. Leon & Assoc., Inc. FL. Lic. 10590 00 Consulting Engineers HEFT - FATE: LL MIAMI, FLORIDA 33187 V CA # 6577 z cry W x 0 ' O� I' >: " "` W ry LL lJ L.L. o LL LL_ z U W W UI J_ IX� Ci DATE: I I/ I _// 10 JOB NO: 1018 -01 DRAWN: JI CHECKED: PR REVISIONS: 12 -1 -10 I.L.A. project # 1070.00 I Pedro P. Ramos, A.I.A. I. Leon & Assoc., Inc. FL. Lic. 10590 -- - - Consulting Engineers HEFT - FATE: 15521 SW 149th. COURT MIAMI, FLORIDA 33187 MECHANICAL CA # 6577 ileonandassoc@bcllsouth.net phone # 305 232 0031 n PLAN x seal: Ismael Lean, P.E., # 40168 I' >: " "`