10-1131-0322 H O O 2 Q D 2 W LL - C7?'C/IL SPLC;iriCAi;Oi ✓S GENERAL A. SEE SECTION 100 OF THE GENERAL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. B. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCE AMONG MECHANICAL, ELECTRICAL ARCHITECTURAL AND STRUCTURAL ITEMS. PROVIDE ALL NECESSARY OFFSETS AND FITTINGS IN CIRCUITRY AND OTHER ITEMS REQUIRED TO INSTALL THE WORK WITHOUT INTERFERENCES. C. ALL EQUIPMENT INSTALLED SHALL BE NOW AND SHALL CONFORM IN ALL RESPECTS TO THE LATEST APPROVED STANDARDS OF EFF., ANSI, NEMA AND UNDERWRITERS LABORATORIES, INC. UNLESS INDICATED OTHERWISE. SUBSTITUTIONS SHALL ONLY BE ACCOMPLISHED AT THE DISCRETION OF THE ENGINEER. D. SHOP DRAWINGS ARE TO BE SUBMITTED AND APPROVED BEFORE THE EQUIPMENT IS ORDERED SUBMIT SIX (6) COPIES OF SHOP DRAWINGS TO THE ENGINEER. E. UNLESS SPECIFICALLY INDICATED OTHERWISE, REMOVE ALL LIGHTING , SWITCHES, AND ASSOCIATED CIRCUITRY CIRCUITRY TO BE REMOVED SHALL BE ALL CONDUCTORS AND ANY EXPOSED RACEWAYS AND ALL RACEWAY THAT BECOMES EXPOSED UPON REMOVAL OF WALLS AND CEILINGS. NOT ALL DEVICES TO BE REMOVED ARE INDICATED. F. UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL CIRCUITRY, EQUIPMENT, DEVICES, ETC. NOT NOTED AS EXISTING TO REMAIN OR TO BE RELOCATED, SHALL BE NEW. CONTRACTOR MAY REUSE ALL EXISTING WALL RECEPTACLES, AND FLOOR BOXES AND OUTLETS WHICH THE ENGINEER DEEMS ARE IN REUSABLE CONDITION. REMOVE ALL DEVICES AND CIRCUITRY NOT BEING REUSED. CIRCUITRY TO BE REMOVED SHALL BE REMOVED BACK TO THE SOURCE AND ALL HOLES SHALL BE REPAIRED TO CONFORM TO FINISHED SURFACE. ALL CIRCUITS THAT ARE TO REMAIN IN SERVICE UPON COMPLETION OF THIS PROJECT WHICH ARE PRESENTLY FED MUST BE CONTINUED IN SERVICE. OUTAGES EXISTING CIRCUITS TO REMAIN SHALL BE COORDINATED WITH THE OWNER. G. PROJECT ADJACENT MATERIALS INDICATED TO REMAIN. INSTALL AND MAINTAIN DUST AND NOISE BARRIERS TO KEEP DIRT, DUST AND NOISE FROM BEING TRANSMITTED TO ADJACENT AREAS. REMOVE PROTECTION AND BARRIERS AFTER DEMOLITION OPERATIONS ARE COMPLETE. H. LOCATE, IDENTIFY AND PROTECT ELECTRICAL SERVICES PASSING THROUGH DEMOLITION AREA AND SERVING OTHER AREAS OUTSIDE THE DEMOLITION LIMITS. MAINTAIN SERVICES TO AREAS OUTSIDE DEMOLITION LIMITS. WHEN SERVICES MUST BE INTERRUPTED, INSTALL TEMPORARY SERVICES FOR AFFECTED AREAS. I. THE ENTIRE ELECTRICAL INSTALLATION SHALL CONFORM TO THE LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE AND ALL OTHER RULES AND REGULATIONS OF THE LOCAL ELECTRICAL AND BUILDING CODES, J. ALL ELECTRICAL _EQUIPMENT SHALL BEAR THE UNDERWRITER'S LABORATORIES LABEL. K. ALL EQUIPMENT TO BE PROVIDED BY THE CONTRACTOR SHALL BE MANUFACTURED BY GENERAL ELECTRIC OR SQUARE -D COMPANY, ONLY ONE OF THE MANUFACTURE'S ABOVE SHALL BE PERMITTED TO BE SELECTED. L. PROVIDE TEMPORARY SERVICE AS DIRECTED FOR LIGHTING AND POWER EQUIPMENT (DRILLS, SAWS, ETC.) VERIFY TEMPORARY REQUIREMENTS WITH GENERAL CONTRACTOR, TEMPORARY LIGHTING AND POWER SHALL MEET OSHA REQUIREMENTS AND LOCAL CODES. TEMPORARY POWER SHALL BE 120V. M. ADVANCE NOTICE SHALL BE GIVEN TO OWNER BEFORE COMMENCEMENT OF WORK ON ANY ELECTRICAL CIRCUITRY, WHETHER OR NOT A OUTAGE IS REQUIRED. N. UNLESS SPECIFICALLY NOTED ON THE PLANS, ALL CIRCUITRY, EQUIPMENT DEVICES, ETC.. NOT NOTED "EXISTING TO REMAIN" OR "TO BE RELOCATED" SHALL BE NEW. 0. ALL FEEDER RACEWAYS, ELECTRICAL PANELS AND ALL MAJOR PIECES OF EQUIPMENT SHALL BE CLEARLY LABELED WITH MINIMUM I" HIGH LETTERS. P. ALL WORKMANSHIP, MATERIALS AND EQUIPMENT SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF AREA OF TENANT. Q. THE CONTRACTOR SHALL VISIT EXISTING SITE AND DETERMINE CONDITIONS WHICH MAY AFFECT HIS OR HER BID. S. THE CONTRACTOR SHALL RESTORE ALL AREAS AND SYSTEMS DISTURBED BY HIS WORK TO THE SATISFACTION OF THE PROJECT MANAGER. T. THE WORK SHALL CONFORM TO THE LATEST EDITION OF THE LOCAL UNIFORM STATEWIDE BUILDING CODE AND THE AUTHORITIES DESIGN MANUAL. A LICENSED QUALIFIED ELECTRICIAN SHALL BE ON THE JOB SITE AT ALL TIMES DURING THE EXECUTION OF ANY ELECTRICAL WORK, U. EXCEPT AS OTHERWISE NOTED, ALL EXISTING ELECTRICAL WORK WHICH WILL NOT BE RENDERED ABSOLUTE AND WHICH MAY BE DISTURBED DUE TO ANY CHANGES REQUIRED UNDER THIS CONTRACT SHALL BE RESTORED TO ITS ORIGINAL OPERATING CONDITION. V. FINAL TESTING AT THE TIME OF FINAL INSPECTION AND TESTS. ALL CONNECTIONS AT PANELBOARDS, DEVICES AND EQUIPMENT AND ALL SPLICES MUST BE COMPLETED. EACH BRANCH CIRCUIT AND ITS RESPECTIVE, CONNECTED EQUIPMENT MUST TEST FREE OF SHORT CIRCUITS. W. UPON COMPLETION OF THE WORK, CLEAN AND POLISH ALL EXPOSED SURFACES IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. JOB RESPONSIBILITY: A. PROVIDE ADEQUATE_ STORAGE FACILITIES FOR MATERIAL AND EQUIPMENT DURING THE PROCESS OF THE WORK. B. BE RESPONSIBLE FOR THE CONDITION OF ALL MATERIAL AND EQUIPMENT EMPLOYED IN THE ELECTRICAL INSTALLATION UNTIL FINAL ACCEPTANCE BY THE OWNER. PROJECT SAME FROM ANY CAUSE WHATSOEVER. C. BE RESPONSIBLE FOR THE REPLACEMENT OF ALL DAMAGED OR DEFECTIVE WORK, MATERIALS EQUIPMENT DO NOT INSTALL SENSITIVE OR DELICATE EQUIPMENT UNTIL MAJOR CONSTRUCTION WORK IS COMPLETED. D. OBSERVE AND CONFORM TO APPLICABLE SAFETY REGULATIONS, INCLUDING THOSE REQUIRED BY THE OWNER'S REPRESENTATIVES. E ERECT AND MAINTAIN SUITABLE BARRIERS, PROTECTIVE DEVICES, LIGHTS AND WARNING SIGNS FOR THE PROTECTION OF NEGLIGENCE, STRIKES, VIOLENCE OR THEFT UP TO THE TIME OF FINAL ACCEPTANCE BY THE OWNER. G. BE RESPONSIBLE FOR ANY LOSS OR INJURY TO PERSONS OR PROPERTY RESULTING FORM NEGLECT OR ANY OTHER CAUSES ON THE PAINT OF THE EMPLOYEES. H. DO NOT LEAVE ANY ELECTRICAL WORK IN HAZARDOUS CONDITION, EVEN TEMPORARY. L ERECT, MAINTAIN AND FINALLY REMOVE ALL SCAFFOLDS, STAGING, FORMS, PLATFORMS AND LADDERS REQUIRED FOR THE ELECTRICAL INSTALLATION. J. DO NOT INSTALL WORK FOR WHICH AN EXTRA CHARGE IS TO BE MADE WITHOUT WRITTEN APPROVAL FROM THE OWNER'S REPRESENTATIVE AND THE OWNER. A WRITTEN REQUEST FOR EXTRA WORK SHALL STATE_ THE NATURE OF THE WORK, BY WHOM REQUESTED AND THE PRICE TO BE CHARGED. LEGEND: ® EXIT LIGHT WITH BATTERY EXIT BACK -UP -90 MIN. DUPLEX RECEPTACLE. SINGLE OUTLET SPECIAL OUTLET NEW WIRING HOT WIRE /,_ NEUTRAL WIRE HOME RUN TO PANELBOARD GROUND WIRE SIZED AS PER NEC ART. 250 EXIT LIGHT /EMERG. COMBO WITH BATTERY BACK -UP -90 MIN. EMER. LIGHT WITH BATTERY BACK -UP -90 MIN. EF. EXHAUST FAN A TELEPHONE OUTLET DATA NOTE: COORDINATE WITH OWNER REPRESENTATIVE- FOR NUMBER AND LOCATION OF TELEPHONE OUTLETS AND PROVIDE THEM ACCORDINGLY WITH ALL ASSOCIATED RUNS TO TELEPHONE BD. IN TEL. ROOM. RACEWAYS, BOXES, CONDUITS. 1. WIRING METHODS: a. EXPOSED CONDUIT b. CONCEALED CONDUIT OR AS APPROVED ARMOR -CLAD (MC) CABLE. 2. ALL CIRCUITRY IN FINISHED AREAS SHALL BE RUN CONCEALED. MINIMUM SIZES CONDUIT SHALL BE 112 "' J. CONDUIT CONNECTIONS AND COUPLINGS SHALL BE OF THE ALL -STEEL COMPRESSION TYPE WITH INSULATED THROAT. 4. EXPOSED AND CONCEALED CIRCUITRY (WHETHER CONDUIT AND WIRE OR CABLE) SHALL BE RUN TIGHT TO CEILING SLAB (AS HIGH AS POSSIBLE TO MAXIMIZE HEADROOM) IN A NEAT, WORKMANLIKE MANNER ALL RUNS SHALL BE PARALLEL OR PERPENDICULAR TO BUILDING WALLS. 5. ALL CIRCUITRY RUNS INDICATED ARE DIAGRAMMATIC. THE CONTRACTOR SHALL DETERMINE IN THE FIELD THE MOST SUITABLE ROUTES. 6. ALL EMPTY RACEWAYS SHALL CONTAIN A DRAG WIRE. EMPTY RACEWAYS 2" OR LARGER IN SIZE SHALL HAVE A MAXIMUM OF 3 -90 DEGREE BENDS. PROVIDE 314" EMT FROM EACH TELEPHONE OR COMMUNICATIONS OUTLET DEVICES TO CEILING SPACE FOR ALL INSULATED WALLS. 7. OUTLET BOXES SHALL BE A MINIMUM OF 4" SQUARE WITH THE APPROPRIATE PLASTER RING OR TILE COVER. 8. WHERE EXISTING WALLS ARE FURRED OUT AND DEVICES ARE NOT NOTED TO BE REMOVED PROVIDE EXTENSION BOXES TO BRING FACE OF DEVICES FLUSH WITH NEW FINISH SURFACE AND CONTINUE IN SERVICE. 9. FINAL CONNECTION TO ALL MOTORS OR VIBRATING EQUIPMENT SHALL BE WITH FLEXIBLE CONDUIT. 10. PROVIDE PULL. JUNCTION, OUTLET AND FLOOR BOXES WHERE SHOWN AND REQUIRED. SIZE AS REQUIRED BY THE NEC AND OTHER APPLICABLE STATE AND LOCAL CODES. 11. ALL JUNCTION BOXES SHALL BE OF CODE GAUGE AND OF THE SIZE REQUIRED TO ACCOMMODATE CONDUCTORS SHOWN. WIRE AND CABLE: 1. ALL CONDUCTORS SHALL BE COPPER, MINIMUM #12 (EXCEPT CONTROL CONDUCTORS AND LIGHTING TIPS AS PERMITTED BY NEC, CONDUCTORS FOR SWITCHING LIGHTS SHALL NOT BE CONSIDERED CONTROL CONDUCTORS) WITH 600 VOLT TYPE "THHN -THWN" INSULATION. CONDUCTORS #10 AND LARGER SHALL BE STRANDED. 2. WHERE APPROVED BY THE AUTHORITIES HAVING JURISDICTION AND THE OWNER 'MC" CABLE MAY BE UTILIZED FOR INTERIOR BRANCH CIRCUITS. J. ALL 'MC " CABLE SHALL HAVE A GREEN INSULATED GROUND WIRE IN ADDITION TO THE BONDING WIRE 4. ALL 120 VOLT CIRCUIT HOMERUNS WHICH ARE OVER 100 LINEAR FEET SHALL BE #10 CONDUCTORS MINIMUM. 5. RUN MULTIPLE HOMERUNS TO ALTERNATELY NUMBERED PANELBOARD CIRCUITS (LE. 1,3,5) 6. ALL CIRCUITRY RUNS ARE DIAGRAMMATIC. THE CONTRACTOR SHALL DETERMINE IN THE FIELD THE MOST SUITABLE ROUTES. ALL RECEPTACLES, LIGHTING FIXTURES, MOTORS, ETC. SHALL BE GROUNDED PER NEC. 7 (ALL RECEPTACLE CIRCUITS SHALL CONTAIN A #12 INSULATED GROUND CONDUCTOR.) 8. THE CONTRACTOR'S RESPONSIBILITY TO BALANCE ALL PHASES IN THE PANEL. (BOARD LOAD) 9. ALL MOTOR CONNECTIONS OUTSIDE SHALL BE DONE WITH FLEXIBLE SEALITE CONDUIT. 10. ALL WIRING AND EQUIPMENT FOR "PLACES OF ASSEMBLY" SHALL COMPLY WITH ARTICLE 318 OF THE NEC. CIRCUIT NUMBERS SHOWN ARE FOR IDENTIFICATION ONLY. 11. WIRE AND CABLE SHALL BE AS MANUFACTURED BY ANACONDA, WALKER, GENERAL CABLE, GENERAL ELECTRIC OR SIMPLEX AND SHALL BE COPPER, MINIMUM CONDUCTIVITY OF 987.. WIRING DEVICES, SWITCHES, RECEPTACLES AND TELEPHONE OUTLETS 1. THE LOCATION OF ALL WIRING DEVICES AND TELEPHONE OUTLETS SHALL BE VERIFIED BEFORE INSTALLATION WITH THE ARCHITECT. THE ARCHITECT MAY, AT HIS OPTION, RELOCATE ANY DEVICES 5 FEET AT NO CHARGE TO THE OWNER. 2. WHERE TWO OR MORE DEVICES ARE SHOWN TOGETHER ON THE PLANS. A MULTI -GANG BOX AND PLATE SHALL BE USED. DEVICES OF DIFFERENT VOLTAGES SHALL BE SEPARATED BE PERMANENTLY INSTALLED BOX PARTITIONS. J. ALL OUTLETS SHOWN ON A WALL BACK TO BACK SHALL BE OFFSET A MINIMUM OF 6" HORIZONTALLY, 2' -0" IN RATED WALLS, 4. WALL MOUNTED WIRING DEVICES SHALL BE IVORY IN COLOR EQUAL TO THE FOLLOWING: a. SINGLE POLE SWITCH: HUBBELL 1221 b. DUPLEX RECEPTACLE: HUBBELL 5,352 c. DUPLEX RECEPTACLE - HUBBELL 5352- ORANGE COLOR FOR COMPUTER CIRCUITS, IDENTIFY CIRCUITS ON DEVICE PLATE 5. DEVICE PLATES AS DIRECTED BY THE ARCHITECT 6. COORDINATE LIGHT SWITCHES SHOWN ON DRAWING WITH DOOR SWINGS. LOCATE LIGHT SWITCH ON LOCK SIDE OF DOOR, 7. COORDINATE WALL MOUNTED TELEPHONE OUTLET LOCATION WITH THE ARCHITECT. TELEPHON /DATA CONDUCTORS WILL BE INSTALLED BY OTHERS. PROVIDE FOR COMPLETE INSTALLATION OF FLOOR DEVICES INCLUDING ALL ACCESSORIES. 8. MOUNTING HEIGHT FOR RECEPTACLES AND TELEPHONE OUTLETS SHALL BE PER PLANS OR AS REQUIRED BY THE LOCAL JURISDICTION REQUIREMENTS. IF NOT NOTED PROVIDE AT 18" A.F.F. BY THE LOCAL JURISDICTION REQUIREMENTS. 9. MOUNTING HEIGHT FOR SINGLE POLE TOGGLE SWITCHES SHALL BE 48" A.F.F. OR AS REQUIRED 10. THE TELEPHONE SYSTEM OUTLET LOCATIONS SHALL BE AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY THE TELEPHONE COMPANY FOR INSTALLATION THE ELECTRICAL CONTRACTOR SHALL FURNISH DEVICE RING AND 114" NYLON PULL CORD FOR EACH LOCATION TO FACILITATE THE PULLING OF CABLES IN THE FUTURE. PROVIDE BLANK DEVICE PLACES 11. EACH RECEPTACLE AND OUTLET SHALL BE LABELED TO INDICATE PANEL AND CIRCUIT BREAKER'S) SUPPLYING THE RECEPTACLE OR OUTLET PROVIDE PRESSURE SENSITIVE, LAMINATED LABEL WITH BLACK LETTERS ON WHITE BACKGROUND. LETTERING HEIGHT IS 118" DISCONNECTS 1. PROVIDE SAFETY SWITCHES INDICATED AND AS REQUIRED BY CODE WITH RATINGS AS REQUIRED BY THE SYSTEM VOLTAGE, PHASE AND LOAD SERVED. 2, PROVIDE NON -FUSED SAFETY SWITCHES UNLESS SPECIFICALLY NOTED FUSED AND NEMA 1 ENCLOSURES UNLESS NOTED OTHERWISE, PROVIDE NEMA 3R ENCLOSURES IN ALL EXTERIOR OR DAMP LOCATIONS AND NEMA 4 ENCLOSURES IN ALL WET LOCATIONS STARTING SHALL HAVE OVERLOAD PROTECTION IN EACH PHASE FOR MOTORS 11,3WP OR LARGER. J. LOCATE DISCONNECT SWITCH FOR MECHANICAL EQUIPMENT TO PERMIT SERVICING OF EQUIPMENT PROVIDE FUSES IF REQUIRED BY MANUFACTURER OF EQUIPMENT FOR U.L. APPROVAL CHECK MOTORS FOR PROPER ROTATION. CONNECT CONDUCTORS AS REQUIRED BY MANUFACTURER. 4. EACH SAFETY SWITCH SHALL BE LABELED TO INDICATE THE EQUIPMENT SERVED AND TO INDICATE THE PANEL AND CIRCUIT BREAKER(S) SUPPLYING THE SAFETY SWITCHES MOUNTED INDOORS SHALL BE LABELED WITH LAMINATE PRESSURE SENSITIVE LABELS WITH BLACK LETTERS ON WHITE BACKGROUND. LETTER HEIGHT IS 1/8 SAFETY SWITCHES MOUNTED OUTDOORS SHALL BE LABELED WITH ENGRAVED BAKELITE WITH WHITE LETTERS ON BLACK BACKGROUND. LETTER HEIGHT IS 114" PANEL BOARD 1. BEFORE ORDERING CIRCUIT BREAKER, COORDINATE ALL CIRCUIT BREAKER TRIPS WITH MECHANICAL EQUIPMENT MANUFACTURER'S REQUIREMENTS. COORDINATE CONDUCTOR SIZE WITH ACTUAL MOTORS ANC OTHER MECHANICAL AND ARCHITECTURAL EQUIPMENT FURNISHED BEFORE INSTALLING CIRCUITRY. 2, PANEL BOARD BUS SHALL BE COPPER. J. PANEL BOARD SHALL BE EQUAL TO SQUARE D, TYPE NEHB OR NQOO UNLESS INDICATED OTHERWISE. 4. ALL PANELBORDS SHALL BE EQUIPPED WITH COMMON KEYED LOCKS, PROVIDE A MINIMUM OF TWO KEYS PER PANEL. PANEL BOARDS SHALL BE COMPETE WITH COVERS AND TRIMS AND SHALL CONTAIN.. GROUND BUS. 5. IN PANLEBOARDS, 'EQUIPPED SPACE" OR 'SPACE" IS DEFINED TO INCLUDE ALL NECESSARY BUS, DEVICE SUPPORTS AND CONNECTIONS FOR INSERTION OF A FURTHER DEVICE. 6. PROVIDE A TYPED CIRCUIT DIRECTORY FOR EACH PANEL BOARD INSTALLED UNIT THIS CONTRACT, IN PLASTIC SLEEVE ATTACHED TO DOOR, WITH COPY OF DIRECTORY TO TENANT 7. PANEL BOARD CIRCUITING SHALL MATCH THE DRAWINGS. CIRCUITINC CHANGES MUST BE APPROVED BY THE ENGINEER. B. CIRCUIT BREAKERS: MOLDED CASE CIRCUIT BREAKER: FRAME SIZE, TRIP RATING, NUMBER OR POLES, AND AUXILIARY DEVICES A INDICATED; INTERRUPTING CAPACITY RATING TO MEET AVAILABLE FAULT CURRENT. 10,000 SYMMETRICAL BUS AMPERES MINIMUM; WITH APPROPRIATE APPLICATION LISTING WHEN USED FOR SWITCHING FLUORESCENT LIGHTING LOAD OR HEATING, AIR CONDITIONING, AND REFRIGERATION EQUIPMENT. FIRE ALARM SYSTEMS 1. FIRE ALARM SYSTEMS: EXTEND THE EXISTING FIRE ALARM SYSTEM TO INCORPORATE ALL CHANGES RESULTING FROM THE NEW WORK. INCLUDE ALL WIRING, RACEWAYS, PULL BOXES, TERMINAL CABINETS, MOUNTING BOXES AND ALL MISCELLANEOUS ITEMS REQUIRED FOR A COMPLETE OPERATION. LIGHTING FIXTURES 1. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE TYPES, QUANTITIES AND LOCATIONS. SEE ENGINEERING PLANS FOR CIRCUITING. 2. PROVIDE FINISHING FRAMES FOR ALL RECESSED LIGHTING FIXTURES. TYPE TO BE COMPATIBLE WITH CEILING. COORDINATE ALL FIXTURE TYPES WITH CEILING SYSTEM BEFORE ORDERING FIXTURE PROVIDE ALL MOUNTING ATTACHMENT'S FOR A COMPLETE INSTALLATION 3. PROVIDE A COMPLETE AND OPERABLE LIGHTING SYSTEM, WHICH SHALL INCLUDE IN PART FLORESCENT LIGHTING FIXTURES, BALLAST, LAMPS, LENSES, SUPPORTS, CANOPIES, FRAMES HARDWARE AND ANY OTHER NECESSARY APPURTENANCES AS MAY BE REQUIRED. 4. PROVIDE ALL NECESSARY ACCESSORY FITTINGS, HANGERS, CLAMPS, BRACKETS, YOKES, PLASTER FLANGES AND MISCELLANEOUS DEVICES AS REQUIRED FOR A COMPLETE INSTALLATION 5. PROVIDE LAMPS FOR EACH TYPE OF LIGHTING FIXTURE IN ACCORDANCE WITH THE FIXTURE MANUFACTURERS LAMP REQUIREMENTS AND RECOMMENDATIONS, UNLESS INDICATED OTHERWISE. ALL TRACK AND ACCENT LAMPS TO BE INSTALLED AT FOR THE TYPE REQUIRED 6. FLORESCENT LIGHTING BALLAST SHALL BE HIGH POWER FACTOR TYPE. CLASS P, ENERGY SAVING, CBM AND ETL CERTIFIED AND RATED FOR SYSTEM VOLTAGE AND FREQUENCY WITH THE QUIETEST SOUND LEVEL RATING AVAILABLE FOR THE TYPE REQUIRED. 7. COLOR OF LIGHTING FIXTURES SHALL BE AS SELECTED BY THE ARCHITECT. 8. OUTLET BOXES SERVING LIGHTING FIXTURES SHALL BE LABELED ON THE COVER PLATE TO SHOW THE PANEL AND CIRCUIT BREAKER(S) SUPPLYING THE FIXTURE(S). OUTLET BOXES LOCATED ABOVE SUSPENDED CEILINGS. IN MECHANICAL OR ELECTRICAL ROOMS OR OTHER SPACES NOT EXPOSED TO GENERAL VIEW MAY BE MARKED WITH INDELIBLE MARKING PEN. OUTLET BOXES EXPOSED TO GENERAL VIEW SHALL BE LABELED AS SPECIFIED FOR RECEPTACLES, EXECUTION A. PROVIDE ALL WORK, EQUIPMENT AND MATERIALS INDICATED B. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH NEC REQUIREMENTS AND ANY ADDITIONAL LOCAL CODES, C. ELECTRICAL IDENTIFICATION 1. PROVIDE COLOR CODING FOR FEEDERS AND BRANCH CIRCUIT CONDUCTORS AS FOLLOWS 2081120 VOLTS PHASE 4801277 VOLTS BLACK A BROWN RED B ORANGE BLUE C YELLOW WHITE NEUTRAL GRAY GREEN GROUND GREEN 2. APPLY CIRCUIT DESIGNATION LABELS OF ENGRAVED PLASTIC LAMINATED FOR DISCONNECT SWITCHES, BREAKERS, PUSHBUTTONS, PLOT LIGHTS, AND SIMILAR ITEMS FOR POWER DISTRIBUTION AND CONTROL COMPONENTS ABOVE. D. GROUNDING 1. GROUNDING ELECTRICAL SYSTEMS AND EQUIPMENT IN ACCORDANCE WITH NEC EXCEPT WHERE GROUNDING IN EXCESS OF NEC REQUIREMENTS IS INDICATED. 2. ALL CIRCUITS SHALL CONTAIN AN INSULATED GROUNDING CONDUCTOR. THIS SHALL APPLY WHETHER INDICATED ON THE DRAWINGS OR NOT. J. SEPARATELY DERIVED SYSTEMS REQUIRED BY NEC TO BE GROUNDED SHALL BE GROUNDED AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. E LIGHTING 1- COORDINATE LIGHTING FIXTURES WITH MECHANICAL EQUIPMENT AND ARCHITECTURAL CEILING PLAN GRID LAYOUT INDICATED IS APPROXIMATE. FINAL LOCATION OF LIGHTING FIXTURES SHALL BE AS DIRECTED IN THE FIELD BY THE ARCHITECT 12 -1 -10 I.L.A. project # 1070.00 NP I - - /,11"114 trng engineers. �¢I16521 149th" COURT IttiI FLORIDA'33187r-0 , #leopard. far, @bellsouth.net W ... p one' X305 x232. 0 3,1 CSI r C`y f seal: Ismael` Leon,' P.E., # 40168 8000 NW 7 Street, Suite 101 Miarni, Florida 33126 T. 3 0 5- 7 4 0- C 1 5 0 F. 3 0 5- 7 4 0- 0 1 5 8 e -mail: tag - dbiCNtagdbi.com corporate license AAC 002228 Copyright Notice: These drawings, designs and ideas are the property of The Architects Group, Inc. and are protected under the copyright laws of Florida, No port thereof shall be copied, or used in connection with any work other than for the specific project for which they have been prepared without written consent of The Architects Group, Inc. V J T M Cn0 U) LJ N �- c i W�ww LLI rr G L CD LL C� � S M� ry =w -W L <t 1 � v 00 s LLI � vr�LL_ U) LJ N �- c i W�ww LLI rr G L CD LL C� � S DATE: 11/17/10 JOB NO: 101 B -01 DRAWN: JI CHECKED: PR REVISIONS: Pedro P. Ramos, A.I.A. FL. Lic, 10590 SI -IEET TITLE: ELECRICAL NOTES SHEET NUMBER: E -3 ry -W L 00 L t..1 z cn J < W O �- LLJ L.L ry �,r LL LL � w OC_ (7) z °L I- w }. w z Z_ <r. Z� Ldv J O Z - � 0 CL - cr) o �r cr) DATE: 11/17/10 JOB NO: 101 B -01 DRAWN: JI CHECKED: PR REVISIONS: Pedro P. Ramos, A.I.A. FL. Lic, 10590 SI -IEET TITLE: ELECRICAL NOTES SHEET NUMBER: E -3