10-1131-011U_ ■1 ■���I r_ F- 0 U) 2 Q D H H E I 0 0 a� a� s V) s a� 0 0 I LL_ CIDI 0 I 0 a� 'o 2 a U_ CL n 0 ..- U L Ql NONBEARING WALL RATINGS: 2 HR 1. FLOOR AND CEILING RUNNERS -- (NOT SHOWN) — CHANNEL SHAPED, 3 -1/2 IN. (HIN) DEEP, WITH MIN 1 -1/4 IN. LONG LEGS, FABRICATED FROM MIN 25 MSG CORROSION- PROTECTED STEEL, ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24 IN. OC MAX. 2. STEEL STUDS -- CHANNEL SHAPED, MIN 3 -1/2 IN. DEEP, 1 -1/4 IN. FLANGES AND 3/16 IN. RETURNS, FABRICATED FROM MIN 25 MSG CORROSION- PROTECTED STEEL, SPACED A MAX OF 24 IN. OC. STUDS TO BE CUT 5/8 IN. LESS THAN ASSEMBLY HEIGHT AND FRICTION -FIT IN PLACE. 3. BATTS AND BLANKETS* -- (OPTIONAL) PLACED IN STUD CAVITIES, ANY GLASS FIBER OR MINERAL WOOL INSULATION BEARING THE UL CLASSIFICATION MARKING AS TO SURFACE BURNING CHARACTERISTICS AND /OR FIRE RESISTANCE. SEE BATTS AND BLANKETS (BKNV OR BZJZ) CATEGORIES FOR NAMES OF CLASSIFIED COMPANIES. 4. GYPSUM BOARD* -- GYPSUM PANELS WITH BEVELED, SQUARE OR TAPERED EDGES, BASE LAYER APPLIED VERTICALLY OR HORIZONTALLY ON BOTH SIDES OF THE STUDS, WITH VERTICAL JOINTS CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. HORIZONTAL EDGE JOINTS (WHEN APPLIED HORIZONTALLY) AND HORIZONTAL BUTT JOINTS (WHEN APPLIED VERTICALLY) ON OPPOSITE SIDES OF STUDS NEED NOT BE STAGGERED OR BACKED. BASE LAYER PANELS ATTACHED TO STUDS WITH 1 IN. LONG TYPE S CREWS SPACED 8 IN. OC WHEN APPLIED HORIZONTALLY, OR 8 IN. OC ALONG THE VERTICAL EDGES AND 12 IN. OC IN THE FIELD WHEN APPLIED VERTICALLY. REMAINING TWO LAYERS APPLIED VERTICALLY OR HORIZONTALLY ON ONE SIDE OF THE WALL. HORIZONTAL BUTT JOINTS STAGGERED A MIN OF 6 IN. ON ADJACENT LAYERS. FIRST OF THESE TWO LAYERS ATTACHED TO STUDS WITH 1 -5/8 IN. LONG TYPE S SCREWS SPACED 12 IN. OC. FACE LAYER ATTACHED TO STUDS WITH 2 -3/8 IN. TYPE S SCREWS SPACED 8 IN. OC WHEN APPLIED HORIZONTALLY, OR 8 IN. OC ALONG THE VERTICAL EDGES AND 12 IN. OC IN THE FIELD WHEN APPLIED VERTICALLY. WHEN USED IN WIDTHS OTHER THAN 48 IN., GYPSUM PANELS TO BE INSTALLED HORIZONTALLY. CANADIAN GYPSUM COMPANY -- 5/8 IN. THICK TYPE AR, C, IP -AR, IP -X1, IP -X2, IPC -AR, SCX, SHX, WRX OR WRC. UNITED STATES GYPSUM CO -- 5/8 IN. THICK TYPE AR, C. FRX -G, IP -AR, IP -X1, IP -X2, IPC -AR, SCX, SHX, WRX OR WRC. USG MEXICO S A DE C V -- 5/8 IN. THICK TYPE AR, C, IP -AR, IP -X1, IP -X2, IPC -AR, SCX, SHX, WRX, WRC. 5. JOINT TAPE AND COMPOUND -- VINYL OR CASON, DRY OR PREMIXED JOINT COMPOUND APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS OF OUTER LAYERS. PAPER TAPE, NOM 2 IN. WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS OF OUTER LAYER PANELS. WHEN SQUARE -EDGE GYPSUM BOARD IS USED, TREATMENT OF JOINTS IS OPTIONAL. 6. CAULKING AND SEALANTS* -- (OPTIONAL, NOT SHOWN) - A BEAD OF ACOUSTICAL SEALANT APPLIED AROUND THE PARTITION PERIMETER FOR SOUND CONTROL. UNITED STATES GYPSUM CO -- TYPE AS 10 *BEARING THE UL CLASSIFICATION MARK FIRE RESISTANCE RATINGS - ANSI /UL 263 NONBEARING WALL RATINGS: 1, 2, 3 OR 4 HOURS (SEE ITEMS 3 AND 4) ONE HOUR DETAILED BELOW (2 THROUGH 4 HOUR RATINGS NOT APPLICABLE TO THIS CONTRACT) 1. FLOOR AND CEILING RUNNERS: (NOT SHOWN) CHANEL SHAPED, FABRICATED FROM MIN. 25 MSG CORROSION - PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STUD SIZE, WITH MIN. 1 IN. LONG LESS, ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24 IN. O.C. MAX. 2. STEEL STUDS: CHANNEL SHAPED, FABRICATED FROM MIN. 25 MSG CORROSION - PROTECTED STEEL, MIN. WIDTH AS INDICATED UNDER ITEM 4, MIN. 14- IN. RETURN, SPACED A MAX. OF 24" O.0 STUDS TO BE CUT %" TO -Y4" IN. LESS THAN ASSEMBLY HEIGHT. 3. BATTS AND BLANKETS* - (OPTIONAL)- MINERAL WOOLBATTS, FRICTION FITED BETWEEN STUDS AND RUNNERS. MIN. NOM. THICKNESS AS INDICATED UNDER ITEM 4. SEE BATTS AND BLANKETS (BKNV OR BZJZ) CATEGORIES FOR NAMES OF CLASSIFIED COMPANIES. 3A. BATTS AND BLANKETS: (OPTIONAL). PLACED IN STUD CAVITIES, ANY GLASS FIBER OR MINERAL WOOL INSULATION BEARING THE UL CERTIFICATION MARKING AS TO SURFACE BURNING CHARACTERISTICS AND /OR FIRE RESISTANCE. SEE BATTS AND BLANKETS (BKNV OR BZJZ) CATEGORIES FOR NAMES OF CLASSIFIED COMPANIES. 4. GYPSUM BOARD *: GYPSUM PANELS WITH BEVELED, SQUARE OR 'TAPERED EDGES, APPLIED VERTICALLY OR HORIZONTALLY. VERTICAL JOINTS CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. VERTICAL JOINTS IN ADJACENT LAYER (MULTILAYER SYSTEMS) STAGGERED ONE STUD CAVITY. HORIZONTAL JOINTS NEED NOT BE BACKED BY STEEL FRAMING. HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT JOINTS ON OPPOSITE SIDES OF STUDS NEED NOT BE STAGGERED. HORIZONTAL EDGE JOINTS AND BUTT JOINTS IN ADJACENT LAYERS (MULTILAYER SYSTEMS) STAGGERED A MIN. OF 12 IN. THE THICKNESS AND NUMBER OF LAYERS FOR THE 1 HR IS % ". 5. FASTENERS -(NOT SHOWN) -TYPE S OR S -12 STEEL SCREWS USED TO ATTACH PANELS TO STUDS (ITEM 2) OR FURRING CHANNELS (ITEM 6). SINGLE LAYER SYSTEMS: 1 IN. LONG FOR Y2 AND 5/8 IN. THICK PANELS OR 1 4 IN. LONG FOR 3/4 IN. THICK PANELS, SPACED 8 IN. O.C. WHEN PANELS ARE APPLIED HORIZONTALLY, OR 8 IN. O.C. ALONG VERTICAL AND BOTTOM EDGES AND 12 IN. O.C. IN THE FILED WHNE PANELS ARE APPLIED VERTICALLY. 7. JOINT TAPE AND COMPOUND: VINYL OR CASEIN, DRY OR PREMIXED JOINT COMPOUND APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS OF OUTER LAYERS. PAPER TAPE, NOM 21N. WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS OF OUTER LAYER PANELS. PAPER TAPE AND JOINT COMPOUND MAY BE OMITTED WHEN GYPSUM PANELS ARE SUPPLIED WITH SQUERE EDGE. 8. CAULKING AND SEALANTS * - (OPTIONAL, NOT SHOWN) -A BEAD OF ACCOUSTICAL SEALANT APPLIED AROUND THE PARTITION PERIMETER FOR SOUND CONTROL. NEW 2x4 FLUORESCENT LIGHT FIXTURE NEW 2x2 AIR SUPPLY GRILLE EXISTING AIR SUPPLY _. GRILLE N AIR SUPPLY GRILLE TO BE REMOVED _ ..... EXISTING TRACK LIGHT _.........._- - -- - -- _ , FIXTURE TO ®R TRACK LIGHT FIXTURE TO BE REMOVED EXISTING RECESSED LIGHT FIXTURE RELOCATED RECESSED LIGHT FIXTURE RECESSED LIGHT FIXTURE TO BE RELOCATED EXISTING RECESSED LIGHT FIXTURE NEW EXIT LIGHT FIXTURE NEW EMERGENCY LIGHT FIXTURE EXISTING EXIT/ EMERGENCY LIGHT FIXTURE COMBO UL_THROUGH- PENETRATION FIRESTOP SYSTEM NO W -L -1222 F RATINGS - 1 T RATINGS - 1/4, AND 3/4 2 HR AND 1 (SEE ITEM HR (SEE 1) ITEM 2) 1. WALL ASSEMBLY- THE 1 OR 2 HOUR FIRE RATED GYPSUM BOARD /STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 B 4 IN LUMBER SPACED 16 IN O.C. STEEL STUDS TO BE MIN 3 -5/8" WIDE AND MAX SPACED 24" O.C. B. GYPSUM BOARD - THICKNESS, TYPE NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OF OPENING IS 10 -5/8 ". THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. 2. THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN THE PIPE, CONDUIT OR TUBE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 2 IN. PIPE, CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS AND TUBES MAY BE USED: A. STEEL PIPE- NOM 8 IN. DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE. B. IRON PIPE- NOM 8 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT- NOM 6 IN. DIAM (OR SMALLER) RIGID STEEL CONDUIT, NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT) OR NOM 4 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. D. COPPER PIPE- NOM 4 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. E. COPPER TUBE- NOM 4 IN. (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBE. TYPE OF PENETRANT MAX DIAM T RATING STEEL OR IRON PIPE, STEEL 2 IN. 1 HR CONDUIT OR EMT STEEL OR IRON PIPE, STEEL 8 IN. 3/4 HR CONDUIT OR EMT COPPER PIPE OR TUBE 4 IN. Y,4. HR 2A. THROUGH PENETRATION PRODUCT * - FLEXIBLE METAL PIPING - AS AN ALTERNATE TO ITEM 2, ONE NOM 1 Y4 IN. DIAM (OR SMALLER) STEEL FLEXIBLE METAL PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN THE PIPE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 2 IN. PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY. OMEGA FLEX INC TITEFLEX CORP A BUNDY CO WARD MFG INC 3. FILL, VOID OR CAVITY MATERIAL * - SEALANT- MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. AT POINT CONTACT LOCATION, MIN Y4 IN. DIAM BEAD OF FILL MATERIAL APPLIED AT METALLIC PIPE/ GYPSUM BOARD INTERFACE ON BOTH SURFACES OF WALL. SPECIFIED TECHNOLOGIES INC- SPECSEAL LCI SEALANT *BEARING THE UL CLASSIFICATION MARK 114. 1 REFLECTIVE CEILING PLAN__ SCALE: 1/4" - 1' -0" ........ . I 8000 NW 7 Street, Suite 101 Miami, Florida 33126 T. 3 0 5— 7 4 0 — 0 1 5 0 F. 305 - 740 -01 58 e —mail: tag— cibi ®tagdbi.com corporate license AAC 002228 Copyright Notice: These drawings, designs and ideas are the property of The Architects Group, Inc. and are protected under the copyright laws of Honda. No port thereof shall be copied, or used in connection with any work other than for the specific project for which they have been prepared without written consent of The Architects Group, Inc. w z 0 U w 0 o- U Z vJ ❑ c��o I � M � -0 A w N Z R LL �00 Ld H oo= E-4 W z L.1_ Q LL V z J W ❑ O 2 W ct 0. Q L.L W r— z N_ I.L.. D O U) Q 1 F_ F_ D LL. z0M 0 z 0 ``_ V Z V� W Lo L0o DATE: 11/17/10 JOB NO: 1018 -01 DRAWN: JI . CHECKED: PR REVISIONS: 1 MW OOMwEM 12/13/10 O� FL. 9Lic. "1'dF 9s a a �tVh SHEET TITLE-1.1, REFLE °e TED CEILING; PLAN SHEET NUMBER. A1:.02 N