Loading...
13-97-011d e 0 0 0 m 0 0 z e ' o t� o� ►L- °s `0c o � e E U 0 O O U) 3m° 0 I o �0 I t C\2 ; F n z S� Wo 2 w a e D e � 00 n» z°C to -C - 0 O1 z -` Ey 0 O U) �¢ V It �N >LL �e in 3 U e � o° b o rA a 00 t� CL m VIO N o� a� _$ t° r-3 CL 'b U 4 o 4� o � oe 0 Cv 0 C C E C c 0 �o �> V o9 oC a �0 4 t0 U � 3 s°. 0 a 0 ' U A, o N ~ cd .M .I 0 kn 0 U a� A U _z z w w z 0 z . w c5 z a . o U a STRUCTURAL NOTES: COORDINATION- -COORDINATE ALL DIMENSIONS, ELEVATIONS 4 OPENINGS WITH ARCHITECTURAL DRAWINGS. REPORT ANY DISCREPANCIES TO OUR OFFICE. - CONTRACTOR MUST VERIFY THE ACCURACY OF ALL EXISTING CONDITIONS WHICH MAY IMPACT THE AMOUNT AND SEQUENCE OF THE WORK EXISTNG CONDITIONS: - EXTREME CARE MUST BE USED DURING ALL NEW EXCAVATION, FOUNDATION AND DEMOLITION WORK SO AS NOT TO UNDERMINE ANY OF THE EXISTING FOUNDATION THAT MUST REMAIN. FOUNDATIONS: -SOIL STATEMENT- VISUAL INSPECTION OF THE SITE SHOWS A SOIL OF LIMESTONE WITH SANDY POCKETS AND WITH A LAYER OF TOPSOIL. THIS LIMESTONE HAS A SAFE BEARING CAPACITY IN EXCESS OF 2000 psF. AT THE TIME OF CONSTRUCTION A LICENSED ARCHITECT OR POFESSIONAL ENGINEER SHALL SUBMIT TO THE BUILDING OFFICIAL A LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATIONS CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED. BUILDING PAD PREPARATION: - TREES, BRUSH, ROOTS, TOPSOIL, RUBBLE, ORGANICALLY CONTAMINATED OR OTHERWISE OBJECTIONABLE MATERIALS ENCOUNTERED ARE TO BE REMOVED FROM STRUCTURAL AREAS OF THE SITE. FOR A MINIMUM DISTANCE OF FIVE FEET OUTSIDE STRUCTURE PERIPHERY. - EXISTING GROUND BENEATH STRUCTURE FOUNDATION SHALL PROOF ROLLED. AREAS EXHIBITING INSTABILITY ARE TO BE UNDERCUT AND BACKFIELD AND COMPACTED. -THE PROPOSED ENGINEERED FILL MATERIALS ARE TO BE PLACED IN LIFTS NOT EXCEEDING EIGHT (8) INCHES, LOOSE MEASURED THICKNESS IN UNCONFINED LIFTS OR 6" IN CONFINED AREAS. EACH LIFT IS TO BE COMPACTED AS FOLLOWS: I.- SLAB ON GRADE: MINIMUM OF 95% MAXIMUM DENSITY BY ASTM D1551. 2.- FOOTING BEARING: MINIMUM OF 95io MAXIMUM DENSITY BY ASTM D1551. TERMITE PROTECTION: AS PER F.B.G. 105.11 BUILDING COMPONENTS AND BUILDING SURROUNDINGS ARE REQUIRED TO BE - PROTECTED FROM TERMITE DAMAGE IN ACCORDANCE WITH 1503.4.4, 1804.6.2.1, 1916.1.5, 2304 OR 26033, OR REQUIRED TO HAVE CHEMICAL SOIL TREATMENT IN ACCORDANCE WITH 1816 SHALL NOT BE COVERED OR CONCEALED UNTIL THE RELEASE FROM THE BUILDING OFFICIAL HAS BEEN RECEIVED. ALL BUILDINGS SHALL HAVE PRE- GONSTRUGTION TREATMENT PROTECTION AGAINST - SUBTERRANEAN TERMITES AS PER F.B.G. 1816.1.1. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES ". CONCRETE: - COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON FILL: 3000 PSI ALL OTHER POURED -IN -PLACE CONCRETE: 3000 PSI GROUT: 3000 PSI - COVER: CONCRETE DEPOSITED AGAINST THE GROUND: 3" FORMED CONCRETE IN CONTACT WITH THE GROUND: -2" BEAMS AND COLUMNS: 1 -1/2" INTERIOR SLABS: 3/4" EXTERIOR SLABS. 1 -1/2" SLAB ON FILL: (PLACED ACCORDING TO ACI 302) - JOINTS: ISOLATION JOINTS MUST BE USED AT JUNCTIONS WITH WALLS AND COLUMNS, USE 112" THICK PREMOLDED JOINTS FULL DEPTH OF SLAB. CONTROL JOINTS PLACED AT CENTERLINE OF COLUMN LINES PROVIDE INTERMEDIATE JOINTS IF COLUMN SPACING IS GREATER THAN 30'. IN SIDEWALKS PROVIDE TOOLED JOINTS SPACED AT INTERVALS EQUAL TO THE WIDTH OF THE SLAB. 4" 4 5" SLABS: P DEEP TOOLED JOINTS MUST BE SAWED BEFORE 24 HOURS AFTER CONCRETING. CONSTRUCTION JOINTS MUST BE PLACED IN THE SLAB WHERE BUILDING EXPANSION JOINTS ARE SHOWN AND WHERE CONTROL JOINTS ARE SHOWN. WHEN CONCRETING AND OPERATING ARE CONCLUDED FOR THE DAY, CONSTRUCTION JOINTS SHALL BE FORMED WITH BURKE KEYED KOLD METAL JOINT FORM OR APPROVED EQUAL. -VAPOR BARRIERS: WATERPROOF MEMBRANES (OVERLAPPED (o" AT JOINTS) WITH A PERMEANCE OF LESS THAN 03% PERMS IN ACCORDANCE WITH A.S.TM. E -98 SHALL BE PROVIDED UNDER INTERIOR SLAB. WHERE NO VAPOR BARRIER IS USED THE SUBGRADE MUST BE DAMPENED WITH WATER IN ADVANCE OF CONCRETING. NO FREE WATER STANDING ON THE SUBGRADE NOR ANY MUDDY OR SOFT SPOT IS PERMITTED. -ANY STRUCTURAL MEMBER PENETRATING SLAB ON FILL IS TO BE 1/2" PRE - MOLDED JOINT FILLER COMPLYING WITH A.S.TM. D -1152, TYPE I. - FINISHING: NO PREMATURE FINISHING SHALL BE ALLOWED. IMMEDIATELY FOLLOWING FLOATING TROWELING WITH STEEL TROWELS SHOULD BE COMMENCED IF REQUIRED BROOMING SHALL BE AFTER THE STEEL TROWELING OPERATION. -SLAB FINISHES: (UNLESS OTHERWISE NOTED BY THE ARCHITECT) BUILDING: STEEL TROWELED OUTSIDE SLAB: BROOMED REINFORCING STEEL: - REINFORCING BARS CONFORMING TO A.S.TM. A -615 GRADE 60, INCLUDING COLUMN AND BEAM TIES. - WELDED FIRE FABRIC CONFORMING TO A.S.TM. A -185 AND SUPPORTED ON SLAB BOLSTERS SPACED AT V -0" O /C. - FABRICATION AND DETAILING ACCORDING TO A.G.I. -315. -ALL ACCESSORIES TO HAVE UPTURNED LEGS AND PLASTIC DIPPED AFTER FABRICATION. TIMBER- -ALL JOISTS AND RAFTERS SHALL HAVE A MIN. STRESS GRADE OF Fb = 1200 PSI, E =1,700,000 PSI (SOUTHERN YELLOW PINE). -TRUSS MANUFACTURER TO SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL INDICATING ALL REACTIONS TO THE SUPPORTING STRUCTURE. PRE - FABRICATED WOOD TRUSSES : -SHALL BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTE (T.P.I.), LATEST EDITION. TRUSSES TO BE ERECTED FOLLOWING THE GUIDELINES OF THE T.P.I. PUBLICATION 50-16. SUBMIT LAYOUT PLAN AND INDIVIDUAL DRAWINGS FOR EACH DIFFERENT TRUSS, SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER, FOR APPROVAL BY STRUCTURAL ENGINEER PRIOR TO FABRICATION. - GENERAL CONTRACTOR TO PROVIDE PERMANENT LATERAL BRACING OF THE BOTTOM CHORD AND THE WEB MEMBERS IN ACCORDANCE WITH RECOMMENDATIONS OF T.P.I. 50-16 AND THE REQUIREMENTS OF THE INDIVIDUAL TRUSS DESIGNS. SUBMIT PERMANENT BRACING PLAN FOR APPROVAL BY ENGINEER PRIOR TO ERECTION. GIRDER TRUSSES TO BE BOLTED TOGETHER WITH 112" DIA. BOLTS AT 24" G/G AT TOP CHORD, BOTTOM CHORD, AND WEB MEMBERS. - CONTRACTOR TO SUBMIT SIGNED AND SEALED SHOP DRAWINGS BY A DELEGATED SPECIALTY ENGINEER FOR ALL TRUSS TO TRUSS CONNECTIONS. TRUSS MANUFACTURER TO VERIFY UPLIFT AND GRAVITY TRUSS REACTIONS SHOWN ON FRAMING PLANS. -ALL TRUSSES AND /OR JOIST SHALL BE SECURED TO THE BEARING PARTITIONS OR THE BEAMS WITH HURRICANE STRAPS AS INDICATED ON PLANS. STAGGER TRUSSES AS REQUIRED TO ACHIEVE PROPER BEARING (4" MIN.). - PROVIDE AN 18 GAGE METAL STRAP TO TIE DOUN ALL THE "PIGGY BACK" TRUSSES TO THE MAIN TRUSSES AT ALL THE BEARING POINTS. - TRUSSES SHALL BE DESIGNED FOR AW ADDITIONAL 200 LBS LOAD AT ANY BOTTOM CHORD PANEL POINT. -TRUSS SPECIALTY ENGINEER MAY OVERSTRESS WOOD FOR WIND DESIGN, NO OVERSTRESS PERMITTED IN METAL PLATES. OWNER ARCHITECT. AND CONTRACTOR NOTE. -CHECK FOR SHOP DRAWINGS AND INSPECTIONS OF REINFORCEMENT IN THE FIELD IS REQUIRED IF THIS OFFICE IS TO BE HELD RESPONSIBLE FOR THE STRUCTURAL ADEQUACY OF THE CONSTRUCTED BUILDING. MASONRY WALLS: - BEARING MASONRY SHOWN THUS IN PLAN SHALL BE ERECTED PRIOR TO THE STRUCTURE ABOVE HAS BEEN POU D. - NON - BEARING MASONRY SHOWN THUS IN PLAN SHALL BE ERECTED AFTER THE STRUCTURE ABOVE HAS BEEN POURED. - MORTAR CONFORMING TO A.S.T.M. C -210 TYPE "M" (2500 PSI). - PROVIDE 9 GAGE LADDER TYPE HORIZONTAL REINFORCEMENT AT 16" O/C (FOR REINFORCED WALLS). - PROVIDE 9 GAGE TRUSS TYPE HORIZONTAL REINFORCEMENT AT 16" O/C (FOR NON - REINFORCED WALLS) - WHENEVER ANCHOR BOLTS ARE TO BE SET IN MASONRY. TWO CELLS AT THE SETTING LOCATION SHALL BE FILLED WITH CONCRETE. -GROUT FOR MASONRY UNITS SHALL CONFORM TO ASTM 0476 -PRISM STRENGTH OF MASONRY UNITS SHALL BE A MINIMUM OF f'm = 1500 PSI. (F'c = 1900 PSI) - MAXIMUM POUR LIFTS FOR MASONRY UNITS AND GROUT POUR HEIGHTS SHALL BE 4' -0 ". -GROUT FOR FILLED CELLS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 3000 PSI WITH A SLUMP OF 9" TO 11 ". - CONCRETE BLOCKS SHALL BE C -90 TYPE, PLACED IN A RUNNING BOND PATTERN. DESIGN CRITERIA: (SUPERIMPOSED LOADS) -LIVE LOAD: 30 PSF (ROOF) -DEAD LOAD: 20 PSF -WIND LOAD: PER A.S.C.E. 1 -10 CATEGORY: IL EXPOSURE - "C" WIND VELOCITY: 115 MPH MEAN ROOF HEIGHT: 13.0' GcPI: 0.18 (ENCLOSED) 0.55 (PARTIALY ENCLOSED) /RI -ALL SHORING, RE- SHORING AND TEMPORARY BRACING REQUIRED IN THIS PROJECT IS TO BE DESIGNED BY FLORIDA PROFESSIONAL ENGINEER WHO SPECIALIZES IN FORM WORK/TEMPORARY BRACING DESIGN. AND WHO HAS BEEN HIRED BY THE GENERAL CONTRACTOR THE GENERAL CONTRACTOR IS THE ULTIMATE RESPONSIBLE PARTY FOR SHORING, RE- SHORING, AND TEMPORARY BRACING REQUIRED ON THIS PROJECT AND MUST SATISFY HIMSELF WITH THE ADEQUACY OF THE INSTALLATION OF THESE ITEMS AT ALL TIMES. SAF ETY OSHA AND LABOR LAWS. -THE STRUCTURE IS DESIGNED TO BE SELF - SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, TEMPORARY BRACING, ETC. THAT MAY BE NEGGESARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE PROJECT. -THE STRUCTURAL ENGINEER OF RECORD DOES NOT POSSES, NOR PRESUMES TO POSSES ANY KNOWLEDGE OR EXPERTISE IN MATTERS TO JOB SITE EMPLOYEE SAFETY, OSHA OR LABOR LAW REQUIREMENTS FOR A CONSTRUCTION PROJECT. SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS ARE THE ABSOLUTE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THOSE CONSULTANTS HE HIRES TO ADDRESS THESE MATTERS. THE STRUCTURAL ENGINEER OF RECORD SPECIALIZES IN STRUCTURAL DESIGN ONLY, AND THE BOARD OF PROFESSIONAL REGULATION FORBIDS HIM FROM ASSUMING RESPONSIBILITY OUTSIDE HIS AREA OF EXPERTISE APPLICABLE CODES: IN MY PROFESSIONAL JUDGEMENT AND THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE FLORIDA BUILDING CODE. - ALTHOUGH THE ENGINEER OF RECORD HAS STRIVED TO MEET ALL APPLICABLE CODES AND LOCAL ORDINANCE REQUIREMENTS, THE CONTRACTOR IS STILL RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND ORDINANCES IN THE EVENT OF CONFLICT OR OVERSIGHT IN THESE DRAWINGS. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER OF ANY CONFLICT OR DISCREPANCY ENCOUNTERED SO THAT APPROPRIATE REMEDIES MAY BE UNDERTAKEN. -THE APPLICABLE CODES ARE: FLORIDA BUILDING CODE, LATEST EDITION. (2010) A.G.I. 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. A.C.I. 530 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. (2008 EDITION) NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. (2005 EDITION) A.I.S.C. MANUAL, 13th EDITION. SHOP DRAWING SUBMITTALS: - SUBMIT FIVE PRINTS OF ALL SHOP DRAWINGS LISTED BELOW. IF SIGNED AND SEALED SHOP DRAWINGS ARE REQUIRED, THEN SUBMIT TWO ADDITIONAL SIGNED AND SEALED PRINTS FOR APPROVAL. -SHOP DRAWINGS: REINFORCING STEEL. STRUCTURAL STEEL. CONCRETE MIX DESIGN. ROOF TRUSSES ROOF OR COLUMN TERMINATION PT. DOUBLE TIES (3" G.G.) 1 JOINT J -2 EL. SEE PLAN VAPOR BARRIER SEE SPECS. WELL COMPACTED FILL STANDARD HOOK — 3 TIES 63" _ r,. OF COLUMN AND FOOTING (U.ON. IN PLAN) CONCRETE SLAB, SEE PLAN FOR THICKNESS AND REINFORCING � J n EL. SEE PLAN DOWELS SAME SIZE 4 NUMBER AS VERT. REINF. (SET TO CLEAR BARS 3" `— STANDARD ABOVE) CLR HOOK FOR FOOTING SIZE AND REINFORCING, SEE SCHEDULE I.- USE 03 TIES FOR 010 VERTICAL REINFORCING OR SMALLER. 2.- TIE SPACING SHALL BE: A - LEAST DIMENSION OF COLUMN B - 16 TIMES MAIN BAR DIAMETER G - 03 AT 18" OR 04 AT 24" WHICHEVER IS SMALLER TYPICAL CONCRETE COLUMN SPLICE DETAIL N.T.S. FOOTING SCHEDULE MARK SIZE W x L x 0 REINFORCEMENT REMARKS LONG. TRANS. WF -16 16 "xCONTx12" 2S - 11811 BARS TC -2 8" x 13" 4 05 03fie8" 4 SPACING EACH ENE) NOTE : 1. CONTRACTOR TO PROVIDE "5 CORNER BARS LAPPED MIN. 30" EACH WAY, FOR EACH BAR IN FOOTING. COLUMN SCHEDULE MARK SIZE REINFORCEMENT REMARKS VERTICALS OR BASE E TIES OR CAP IE TC -1 S" x 12" 4 05 03fie8" 11811 BARS TC -2 8" x 13" 4 05 03fie8" 4 SPACING EACH ENE) TC -3 8" x 24" 6 05 03fi -s8" 2S OI 8" x 12" 4 05 #36'08" *3 O2 8" x 16" 4 06 #3f,@8° m m Ly❑ ❑ O ago O Ld RTB -1 NOTE : Q DENOTES COLUMN START 0 DENOTES COLUMN END COL. (D g TC -2 1 -0' +fD TC -1 4 COL. IQ • a � • .a a TC -1, TC -2, COL. D ,COLOZ PETS. ., • •Qe G "3 HAIRPIN a 8 "O /C COL. TG-3 PET. BEAM SCHEDULE MARK TOP ELEV. SIZE (INCHES) BOTTOM. REItF. TOP REINFORCING STIRRUPS REMARKS W E) "All BARS 11811 BARS (ICI: BARS 'IT" BARS "Ell BARS SIZE SIZE 4 SPACING EACH ENE) T5-1 VARIES 8" 12" 2S 2S *3 4012" BAL o48" z O w Imo- m m Ly❑ ❑ O ago O Ld RTB -1 VARIES all 12" 2 05 Uj - 2S 03 4612" BAL 648" RAKED BEAM [L >n Z RB -1 8' -8" 8" 18" 2 06 2 "6 03 *3 'IT" BA GREATER OF 05 L I OR 0.3 L2 IIEII BARSJ I I \ "C" BA 4_1 IIAII BARS L L2 EMBED 12 BAR DIAM. NOTE 'IT" BAR 0.3 L IIBII BARS LENGTH L/3 2' -2" (TYP.) I "C" BARS I 2II ' "All BARS 441, L3 IIAII BARS MID BARS - L4 STIRRUPS GLASS "A" LAP SPLICE II II T BARS RUN CONTINUOUS OR LAP AS REQ'D. AT MID SPAN. 0.3 L "Ell BARS STD. NOOKS 1. "L" IS THE LONGER OF ADJACENT SPAN. 6. TOP AND BOTTOM REINFORCEMENT SHALL BE CONTINUOUS FOR ALL TIE BEAMS. 2. 8" WIDE BEAMS TAKE A MAXIMUM OF 2 BARS PER LAYER. I. AS PER ACI 315 -02, SECTION 1.13.2.2 IN EXTERIOR PERIMETER BEAMS PROVIDE 3. STIRRUPS TO BE CLOSED TYPE WITH 135° HOOK. ADDITIONAL BOTTOM REINFORCEMENT OVER THE SUPPORTS EQUAL TO AT LEAST 25% OF 4. MID BARS TO BE #5 012" E.F. WHENEVER BEAM DEPTH THE LARGER TOTAL BOTTOM REINFORCEMENT AREA CALLED OUT FOR THE MID -SPAN OF IS LARGER THAN 2' -0" ADJACENT BEAMS, AND IN ADDITION, AT LEAST 20% OF THE TOP REINFORCEMENT, BUT NO LESS THAN TWO BARS, SHALL BE CONTINUOUS OVER ALL SUPPORTS. THIS ADDITIONAL 5. CONTRACTOR TO PROVIDE 2 #5 CORNER BARS LAPPED REINFORCEMENT IS TO BE SPLICED WITH A TENSION "CLASS A" SPLICE BEGINNING AT THE MIN. 30" EACH WAY. FACE OF THE SUPPORT. TYPICAL BEAM BAR PLACING DIAGRAM i of South Miami N.T.S. C Building Dept, 6130 Sunset Drive South Miami, FL 33143 "C" BARS FOR 12" OR WIDER BEAMS. TOP BARS - X "C" BARS (FOR 8" BMS.) "MID" BARS (SEE NOTE 4) d`rQ "MID" BARS (SEE NOTE 4) Ci �+ X a:50TTOM w.. " BARS NOTE - QUANTITY OF "MID" BARS VARIES W/ BEAMS DEPTH. SEE BEAMS SEE NOTE -4 ON BAR PLACING DIAGRAM TYPICAL BAR PLACEMENT DETAIL N.T.S. Of SUUt�': CI�Buildin�'. oej5 , 61305 South hA%3n' .j BRAVO L L C architecture p l a n n i n g interior design AA 26000771 IB 26000638 250 catalonia, suite 403 coral gables, Florida 33134 telephone : 305 .567. 1977 facsimile 305 . 567 . 1125 0 AS NOTED DRAWN BY: Y. SOSA CHECKED BY: PM DATE: 11-05-12 z N FILE NAME: O LIJ o r�i� (D Q W w mil' z O w Imo- m m Ly❑ ❑ O ago O Ld w §� ,> Uj - O OD 'Q Fr W [L >n Z REVISIONS: 0 0 SCALE: AS NOTED DRAWN BY: Y. SOSA CHECKED BY: PM DATE: 11-05-12 PROJECT NO.: FILE NAME: SUBMITTAL SHEET NUMBER 13