13-97-010a
U
N
O
0
0
z
0
..o
L �
U
Q y
•N O
F- 3
O C
_ U
C y
N E
c E
0 0
U
C
�m
U_
U
U +O+
N L
n`
3F_
��2
U
X (n
W �
.0 .0
U o
0_
O U
� T
0 C
m¢
o c
z :-
> O
O N
0 E
0
J Ln
J �
O 0
> L,.
0
M
wEn
0
0
>1 N
a�
0 y
am
C
L Q
cn.0
Q..)
U L
�o
N
C
<.O
N y
.o 0
°a
rw
a •`
N
.9V
N C
U Q
O Y
N U
U
0
O
U
N
NOTES:
SUBMIT WINDOWS, EXTERIOR DOORS, AND MULLIONS PRODUCT
APPROVALS TO CITY FOR SEPARATE PERMIT.
WINDOWS AND EXTERIOR DOORS WHICH ARE NON- IMPACT RESISTANT
MUST PROVIDE PRODUCT APPROVED SHUTTERS UNDER SEPARATE PERMIT
EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN
THE DOOR FROM INSIDE THE CLOSET.
EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE
OPENING
OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY.
GENERAL DOOR AND
WINDOW NOTES:
WINDOW AND DOOR ASSEMBLIES AND THEIR INSTALLATION SHALL BE IN
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AS SET FORTH
IN APPROVED PRODUCT CONTROL SUBMITTALS PER THE F.B.C.
ALL FIXED GLASS PANELS SHALL BE 3116' OR THICKER AS REQ. TO MEET
WIND LOADS AND IMPACT REWREMENTS. SAFETY GLASS. ALL GLASS USED
INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C.
EGRESS TYPE WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT
THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT, AND SHALL
PROVIDE A CLEAR OPENING OF NOT LESS THAN 20' WIDE. 24' HIGH, AND
5.7 FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE
THAN 44' ABOVE THE FLOOR, AND NO PART OF THE MECHANISM SHALL
BE PLACED HIGHER THAN 54' ABOVE THE FLOOR.
PROVIDE HURRICANE SHUTTERS APPROVED BY COUNTY PRODUCTS
CONTROL AT ALL REQUIRED DOOR AND WINDOW OPENINGS.
WITH NON— IMPACT WINDOWS.
PROVIDE OPAQUE GLASS AT BATHROOM WIDOW AS PER F.B.C.
PROVIDE SAFETY TEMPERED GLASS AS PER F.B.C. FOR WINDOW
AND SHOWER ENCLOSURE.
Contractor shall verify with window and doors manufacturer s
required masonry opening for proper Installation before concrete
block work Is started or tie columnS are poured.
CAT. II SAFETY GLASS SHALL BE USED AT ALL SHOWER
AND TUB ENCLOSURES INCLUDING WINDOWS WITH SILLS
LOWER THAN 60' AND MIRRORS IN THE TUB.
ALSO, IT SHALL BE USED ON OPENINGS WITHIN It
OF DOORS.
ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE
OF 300 I.B. APPLIED IN ANY MOVABLE DIRECTION IN ACCORDANCE WITH
RESISTANCE STANDARDS SET FORTH IN F.B.C.
PANELS.
FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE
OR VISION
DOORS AND WINDOWS
SUBMIT SHOP DWG's FOR APPROVALS IN SEPARATE PERMIT
ALL FIXED GLASS SIDELITES SHALL BE TEMPERED GLASS.
=+vra�arr a �� �asu � aw w.�ays
BURGLARY INTRUSION
NOTES:
1. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE
KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000
POSSIBLE KEY CHANGES OR LOCKING COMBINATIONS. IF KEY —IN-
THE KNOB LOCK IS USED THERE SHALL BE AN AUXILIARY SINGLE
DEAD BOLT WITH HARDENED BOLT INSERTS.
2. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL
HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING
DOOR. THE INACTIVE LEAF OF THESE PAIL OF DOORS SHALL
HAVE MULTIPLE POINT LOCKS WITH 5/8' MIN. THROW BOLTS
WITH INSERTS.
3. SLIDING GLASS DOORS SHALL BE PROVIDED WITH SLIDING DOOR
DEAD BOLTS OR A BOLT OR PIN NOT REMOVABLE OR OPERABLE
FOR EXTERIOR, AT THE JAMB, HEAD, SILL OR AT MEETING
MULLIONS. THESE DOORS SHALL BE REINFORCED IN THE STRIKE
AND LOCK ARE TO MAINTAIN BOLT STRENGTH EFFECTIVENESS, IF
NECESSARY, AND SUCH DOORS SHALL HAVE NO SCREWS REMOVABLE
FROM THE OUTSIDE WHICH WOULD FACILITATE READY ENTRY FROM
OUTSIDE.
4. OVERHEAD DOORS SHALL BE PROVIDED WITH MULTIPLE POINT
LOCKS OR BE LOCKED AT MORE THAN ONE POINT WITH HARDENED
BOLT OR BOLTS WITH INSERTS ENGAGING AT LEAST TWO OPPOSITE
POINTS A MIN. 5113'. OTHER LOCKING DEVICES SHALL NOT BE
REQUIRED WHERE SUCH DOORS ARE CONTROLLED AND LOCKED
BY ELECTRIC POWER.
5. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON
REMOVABLE PINS.
6. JAMS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS BE
RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT
DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF
LOCKS AND LATCHES.
7. SINGLE SWINGING EXTERIOR DOOR IF WOOD, SHALL BE SOLID
CORE OF NOT LESS THAN 1 1/8' THICK.
B. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN
NATIONAL STANDARDS INSTITUTES — STANDARD 297.1.
9. VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING
WITHIN 40' OF THE INSIDE LOCKING ACTIVATING DEVICE OF
LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN
NATIONAL STANDARDS INSTITUTES — STANDARD.
10. SLING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND
CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE
TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY
WITH THE ARCHITECTURAL ALUMINUM MANUFACTURER'S
ASSOCIATION STANDARDS FOR FORCED ENTRY RESISTANCE
11. VENTS ON OVERHEAD GARAGE TYPE DOORS SHALL NOT BE
INSTALLED CLOSER THAN 40' TO THE INSIDE LOCK ACTIVATING
DEVICE.
12 SINGLE SWING DaMOZ AND SWING DOORS CONNECTING LIVING
AREAS WITH GARAGE AREA SHALL BE A MIN. 1 3/8' THICK,
SOLID CORE, AND SHALL BE SECURED WITH A LATCH AND SINGLE
DEAD BOLT SETS WITH LATCH THROW MIN. OF 1/2' AND BOLTS
HAVING A MIN. OF 1' THROW.
I& FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR
SCOPE OR VISION PANEL
14. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF
RESISTING A FORCE OF 300 LBS APPLED IN ANY MOVABLE
DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS
SET FORTH IN METRO CODE/SOUTH FLORIDA BUILDING CODE.
COMPONENTS OF MEANS OF ESCAPE
(A) NO DOOR IN THE PATH OF TRAVEL OF MEANS OF ESCAPE SHALL BE LESS THAN 2' -8' WIDE,
EXCEPT THAT BATHROOM DOORS MAY BE 24' WIDE UNLESS A LARGER DOOR OPENING IS REQUIRED
TO SATISFY REQUIREMENTS
(B) EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE
THE CLOSET.
(C) EVERY BATHROOM DOOR LOCK SHALL BE DESIGN TO PERMIT THE OPENING OF THE LOCKED DOOR
FROM THE OUTSIDE IN AN EMERGENCY.
(D) DOORS MAY BE SWINGING OR SLIDING AND ARE EXEMPT FROM THE REQUIREMENTS
(E) NO DOOR IN ANY MEANS OF ESCAPE SHALL BE LOCKED AGAINST EGRESS WHEN THE BUILDING IS
OCCUPIED. ALL LOCKING DEVICES WHICH IMPEDE OR PROHIBIT EGRESS OR WHICH CANNOT BE EASILY
DISENGAGED SHALL BE PROHIBITED.
NOTE:
ALL NEW WINDOWS TO BE PROVIDED W/ MIAMI —DADE
APPROVED SHUTTERS.
ALL SHUTTERS TO BE DESIGNED BY A QUALIFIED
REGISTERED DELEGATE ENGINEER FOLLOWING
PROCEDURES do GUIDELINES SET FORTH BY SECTION
2413 OF F.B.C. RESIDENTIAL 2010 ED
NOTE:
COORDINATE ALL MASONRY OPENINGS FOR WINDOWS
& DOORS WITH WINDOWS & DOOR MANUFACTURER
PRIOR TO TIE BEAM AND BLOC( ERECTION.
WINDOW SCHEDULE
NO.
TYPE
MODULAR SIZES
REMARKS
W
H
A
HR
74'
38 -3/8'
IMPACT RESISTANT (EGRESS)
B
HR
42'
24'
8' -0'
C
HR
37'
63'
C
2
ENTRY
3' -0'
W-80
1 3/4'
RAISED PANEL
METAL
PAINTED
16' -0'
DOOR SCHEDULE
NO.
LOCATION
SIHE
TYPE
MATERIAL
FINISH
THRESHOLD
JAMB
REMARKS
W
AA 26000771
T
1
GARAGE
16' -0'
8' -0'
1 3/4'
O.H. GARAGE
METAL
facsimile 305.567. 1125
C
2
ENTRY
3' -0'
W-80
1 3/4'
RAISED PANEL
METAL
PAINTED
FLUSH
METAL
Mn'�.
W LITES
3
GARAGE
3' -0'
6' -8'
1 3/8'
SOLID CORE
METAL
PAINTED
°
METAL
SEE FINISH NOTES
4
GARAGE
3' -0'
6' -8'
1 3/8'
SOUD CORE
METAL
PAINTED
METAL
EXI TED
MTL THRESHOLD, AUTO CLOSE,
00
Ln
:�E
W
L
z
NOTES:
1.— COORDINATE MASONRY OPENING W/ DOOR MANUFACTURER PRIOR TO WALL ERECTION (SUBMIT SHOP DRAWINGD FOR APPROVAL.)
2.— ALL EXTERIOR DOORS TO RECEIVE SILL TO MATCH FLOOR FINISH.
• DOOR FRAME SHALL BE SOLID 2 x 4 RABBETED WOOD FRAME
O O O O
� HR
DOOR TYPES
SCALE: 3/8 " =1' -0"
�37 "�
co
HR
O O O
WINDOWS TYPES
SCALE: 3/8 " =1' -0"
M�am�
- Ot % t.
G�t`1 of qep
63 Svset �r, 3A 43
south Mja�n`'
3
CITY 01 SOUTH MIAM?11
Ps'_UILD'ING DEPT.
5TR UCT!. R —CTION
BRAVO
L L
C
a r e h i t e
e t u r e
p I a n n
i n g
interior
design
FILE NAME:
AA 26000771
SUBMITTAL
IB 26000638
250 catalonia,
suite 403
coral gables, florida
33134
telephone 305
.567. 1977
facsimile 305.567. 1125
o
N
DRAWN BY:
A.P.
z
W
DATE:
05 -23-1
O
FILE NAME:
SUBMITTAL
�
o
Q
C
0
w
16
0
ct:�
Co
z
w
C
CD
o
g�
W
°O
°
LLJ �
Q
�
Q
O
00
Ln
:�E
W
L
z
REVISIONS:
0
A\
SCALE:
AS NOTED
DRAWN BY:
A.P.
CHECKED BY:
P.B.
DATE:
05 -23-1
PROJECT NO.:
FILE NAME:
SUBMITTAL
I SHEET NUMBER
A -9
FL'
P. CARLOS BRdVO, RA
FTA. REGISTRATION `NO.: 6226