Loading...
13-97-010a U N O 0 0 z 0 ..o L � U Q y •N O F- 3 O C _ U C y N E c E 0 0 U C �m U_ U U +O+ N L n` 3F_ ��2 U X (n W � .0 .0 U o 0_ O U � T 0 C m¢ o c z :- > O O N 0 E 0 J Ln J � O 0 > L,. 0 M wEn 0 0 >1 N a� 0 y am C L Q cn.0 Q..) U L �o N C <.O N y .o 0 °a rw a •` N .9V N C U Q O Y N U U 0 O U N NOTES: SUBMIT WINDOWS, EXTERIOR DOORS, AND MULLIONS PRODUCT APPROVALS TO CITY FOR SEPARATE PERMIT. WINDOWS AND EXTERIOR DOORS WHICH ARE NON- IMPACT RESISTANT MUST PROVIDE PRODUCT APPROVED SHUTTERS UNDER SEPARATE PERMIT EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. GENERAL DOOR AND WINDOW NOTES: WINDOW AND DOOR ASSEMBLIES AND THEIR INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AS SET FORTH IN APPROVED PRODUCT CONTROL SUBMITTALS PER THE F.B.C. ALL FIXED GLASS PANELS SHALL BE 3116' OR THICKER AS REQ. TO MEET WIND LOADS AND IMPACT REWREMENTS. SAFETY GLASS. ALL GLASS USED INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C. EGRESS TYPE WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT, AND SHALL PROVIDE A CLEAR OPENING OF NOT LESS THAN 20' WIDE. 24' HIGH, AND 5.7 FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' ABOVE THE FLOOR, AND NO PART OF THE MECHANISM SHALL BE PLACED HIGHER THAN 54' ABOVE THE FLOOR. PROVIDE HURRICANE SHUTTERS APPROVED BY COUNTY PRODUCTS CONTROL AT ALL REQUIRED DOOR AND WINDOW OPENINGS. WITH NON— IMPACT WINDOWS. PROVIDE OPAQUE GLASS AT BATHROOM WIDOW AS PER F.B.C. PROVIDE SAFETY TEMPERED GLASS AS PER F.B.C. FOR WINDOW AND SHOWER ENCLOSURE. Contractor shall verify with window and doors manufacturer s required masonry opening for proper Installation before concrete block work Is started or tie columnS are poured. CAT. II SAFETY GLASS SHALL BE USED AT ALL SHOWER AND TUB ENCLOSURES INCLUDING WINDOWS WITH SILLS LOWER THAN 60' AND MIRRORS IN THE TUB. ALSO, IT SHALL BE USED ON OPENINGS WITHIN It OF DOORS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 I.B. APPLIED IN ANY MOVABLE DIRECTION IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN F.B.C. PANELS. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION DOORS AND WINDOWS SUBMIT SHOP DWG's FOR APPROVALS IN SEPARATE PERMIT ALL FIXED GLASS SIDELITES SHALL BE TEMPERED GLASS. =+vra�arr a �� �asu � aw w.�ays BURGLARY INTRUSION NOTES: 1. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING COMBINATIONS. IF KEY —IN- THE KNOB LOCK IS USED THERE SHALL BE AN AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT INSERTS. 2. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOOR. THE INACTIVE LEAF OF THESE PAIL OF DOORS SHALL HAVE MULTIPLE POINT LOCKS WITH 5/8' MIN. THROW BOLTS WITH INSERTS. 3. SLIDING GLASS DOORS SHALL BE PROVIDED WITH SLIDING DOOR DEAD BOLTS OR A BOLT OR PIN NOT REMOVABLE OR OPERABLE FOR EXTERIOR, AT THE JAMB, HEAD, SILL OR AT MEETING MULLIONS. THESE DOORS SHALL BE REINFORCED IN THE STRIKE AND LOCK ARE TO MAINTAIN BOLT STRENGTH EFFECTIVENESS, IF NECESSARY, AND SUCH DOORS SHALL HAVE NO SCREWS REMOVABLE FROM THE OUTSIDE WHICH WOULD FACILITATE READY ENTRY FROM OUTSIDE. 4. OVERHEAD DOORS SHALL BE PROVIDED WITH MULTIPLE POINT LOCKS OR BE LOCKED AT MORE THAN ONE POINT WITH HARDENED BOLT OR BOLTS WITH INSERTS ENGAGING AT LEAST TWO OPPOSITE POINTS A MIN. 5113'. OTHER LOCKING DEVICES SHALL NOT BE REQUIRED WHERE SUCH DOORS ARE CONTROLLED AND LOCKED BY ELECTRIC POWER. 5. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON REMOVABLE PINS. 6. JAMS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS BE RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF LOCKS AND LATCHES. 7. SINGLE SWINGING EXTERIOR DOOR IF WOOD, SHALL BE SOLID CORE OF NOT LESS THAN 1 1/8' THICK. B. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARDS INSTITUTES — STANDARD 297.1. 9. VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40' OF THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTES — STANDARD. 10. SLING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MANUFACTURER'S ASSOCIATION STANDARDS FOR FORCED ENTRY RESISTANCE 11. VENTS ON OVERHEAD GARAGE TYPE DOORS SHALL NOT BE INSTALLED CLOSER THAN 40' TO THE INSIDE LOCK ACTIVATING DEVICE. 12 SINGLE SWING DaMOZ AND SWING DOORS CONNECTING LIVING AREAS WITH GARAGE AREA SHALL BE A MIN. 1 3/8' THICK, SOLID CORE, AND SHALL BE SECURED WITH A LATCH AND SINGLE DEAD BOLT SETS WITH LATCH THROW MIN. OF 1/2' AND BOLTS HAVING A MIN. OF 1' THROW. I& FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANEL 14. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LBS APPLED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN METRO CODE/SOUTH FLORIDA BUILDING CODE. COMPONENTS OF MEANS OF ESCAPE (A) NO DOOR IN THE PATH OF TRAVEL OF MEANS OF ESCAPE SHALL BE LESS THAN 2' -8' WIDE, EXCEPT THAT BATHROOM DOORS MAY BE 24' WIDE UNLESS A LARGER DOOR OPENING IS REQUIRED TO SATISFY REQUIREMENTS (B) EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. (C) EVERY BATHROOM DOOR LOCK SHALL BE DESIGN TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. (D) DOORS MAY BE SWINGING OR SLIDING AND ARE EXEMPT FROM THE REQUIREMENTS (E) NO DOOR IN ANY MEANS OF ESCAPE SHALL BE LOCKED AGAINST EGRESS WHEN THE BUILDING IS OCCUPIED. ALL LOCKING DEVICES WHICH IMPEDE OR PROHIBIT EGRESS OR WHICH CANNOT BE EASILY DISENGAGED SHALL BE PROHIBITED. NOTE: ALL NEW WINDOWS TO BE PROVIDED W/ MIAMI —DADE APPROVED SHUTTERS. ALL SHUTTERS TO BE DESIGNED BY A QUALIFIED REGISTERED DELEGATE ENGINEER FOLLOWING PROCEDURES do GUIDELINES SET FORTH BY SECTION 2413 OF F.B.C. RESIDENTIAL 2010 ED NOTE: COORDINATE ALL MASONRY OPENINGS FOR WINDOWS & DOORS WITH WINDOWS & DOOR MANUFACTURER PRIOR TO TIE BEAM AND BLOC( ERECTION. WINDOW SCHEDULE NO. TYPE MODULAR SIZES REMARKS W H A HR 74' 38 -3/8' IMPACT RESISTANT (EGRESS) B HR 42' 24' 8' -0' C HR 37' 63' C 2 ENTRY 3' -0' W-80 1 3/4' RAISED PANEL METAL PAINTED 16' -0' DOOR SCHEDULE NO. LOCATION SIHE TYPE MATERIAL FINISH THRESHOLD JAMB REMARKS W AA 26000771 T 1 GARAGE 16' -0' 8' -0' 1 3/4' O.H. GARAGE METAL facsimile 305.567. 1125 C 2 ENTRY 3' -0' W-80 1 3/4' RAISED PANEL METAL PAINTED FLUSH METAL Mn'�. W LITES 3 GARAGE 3' -0' 6' -8' 1 3/8' SOLID CORE METAL PAINTED ° METAL SEE FINISH NOTES 4 GARAGE 3' -0' 6' -8' 1 3/8' SOUD CORE METAL PAINTED METAL EXI TED MTL THRESHOLD, AUTO CLOSE, 00 Ln :�E W L z NOTES: 1.— COORDINATE MASONRY OPENING W/ DOOR MANUFACTURER PRIOR TO WALL ERECTION (SUBMIT SHOP DRAWINGD FOR APPROVAL.) 2.— ALL EXTERIOR DOORS TO RECEIVE SILL TO MATCH FLOOR FINISH. • DOOR FRAME SHALL BE SOLID 2 x 4 RABBETED WOOD FRAME O O O O � HR DOOR TYPES SCALE: 3/8 " =1' -0" �37 "� co HR O O O WINDOWS TYPES SCALE: 3/8 " =1' -0" M�am� - Ot % t. G�t`1 of qep 63 Svset �r, 3A 43 south Mja�n`' 3 CITY 01 SOUTH MIAM?11 Ps'_UILD'ING DEPT. 5TR UCT!. R —CTION BRAVO L L C a r e h i t e e t u r e p I a n n i n g interior design FILE NAME: AA 26000771 SUBMITTAL IB 26000638 250 catalonia, suite 403 coral gables, florida 33134 telephone 305 .567. 1977 facsimile 305.567. 1125 o N DRAWN BY: A.P. z W DATE: 05 -23-1 O FILE NAME: SUBMITTAL � o Q C 0 w 16 0 ct:� Co z w C CD o g� W °O ° LLJ � Q � Q O 00 Ln :�E W L z REVISIONS: 0 A\ SCALE: AS NOTED DRAWN BY: A.P. CHECKED BY: P.B. DATE: 05 -23-1 PROJECT NO.: FILE NAME: SUBMITTAL I SHEET NUMBER A -9 FL' P. CARLOS BRdVO, RA FTA. REGISTRATION `NO.: 6226