Loading...
13-1330-007ICI I INTAKE LOUVER EXHAUST LOUVER 24 "X12" 24 °X12" SECOND FLOOR CONCRETE W X H SF -1 EF -1 W X H A ,5 4... 'd a . , Q s f HOOD SCHEDULE HOOD # MFG. MODEL # LENGTH TYPE EXHAUST COLLAR MATERIAL WGT SIZE S.P. CFM 1 #1 5' -6" 12" 20" x 8" 1/4" 440 1 HOOD DEPOT VHH- 0664224112 I 5' -6" I TYPE II I HOOD 14" x 14" 1/4- 550 430 S/S 250 LBS MUA PLENUM SCHEDULE PLENUM # HOOD # LENGTH WIDTH SUPPLY COLLAR AREA of MUA PERF VELOCITY THRU MUA PERF WGT SIZE S.P. CFM 1 #1 5' -6" 12" 20" x 8" 1/4" 440 5.5 SQFT 80 FPM 40 LBS FAN SCHEDULE HOOD # FANS MFG. MODEL # CFM S. P. HP VOLTAGE RPM AMPS WGT # 1 EF -1 ' JENCO TD -315 550 1 °' 335W 115V/10- 1550 2.8 35 LBS #1 SF -1 JENCO TD -315 440 1" 335W 115V/1 1450 2.8 35 LBS HVAC DESIGN CRITERIA YES NO FIRE DAMPER 550 X SMOKE DAMPER X FIRE RATED CEILING TOTAL AIR VOLUME - X DUCT SMOKE DETECTOR X FIRE RATED ENCLOSURE X AIR , BALANCE SCHEDULE EX CFM SUPPLY CFM AIR EXHAUSTED FROM HOODS 550 AIR SUPPLIED TO HOODS 440 TOTAL AIR VOLUME - 550 440 3/8 "0 ALL THREADED ROD FASTENED TO GENERAL NOTES: TOP CORE OF EXISTING BAR JOIST W/ BEAM CLAMPS AND TO 1 5/8" UNISTRUT OR 1. HEAT HOOD: 2 "X2 "Xi" ANGLE IRON W/ 3/8 "0 MATERIAL: 18 GAUGE STAINLESS STEEL CONSTRUCTION BOLTS , WASHERS AND NUTS. ALL CONTINUOUS EXTERNAL LIQUID TIGHT WELDS, POLISHED. ALL IN COMPLIANCE WITH NFPA #96 AND LOCAL BUILDING CODES. Q BAR JOIST 2. HEAT HOOD EXHAUST DUCTS: MATERIAL: 24 GALVANIZED SHEET METAL. GAUGES, 3 /8" ALL — THREAD ROD TO HANGING AND REINFORCING PER SMACNA STANDARDS. 12 GA. HANGER WITH WASHERS c� AND NUTS, TOP & BOTTOM. 3. HEAT HOOD SUPPLY DUCTS: b TOP OF HOOD MATERIAL: GALVANIZED SHEET METAL GAUGES, HANGING AND REINFORCING PER SMACNA STANDARDS. 4. HEAT HOOD EXHAUST FAN: 12 GA. HANGER AS SPECIFIED ON DRAWINGS AND CONFORMING TO WELDED TO TOP A NATIONAL TESTING AUTHORITY FOR PERFORMANCE OF HOOD CERTIFICATION AND UL LISTED SUBJECT BULLETIN 705. 5. HEAT HOOD SUPPLY FAN: HOOD HANGING DETAIL AS SPECIFIED ON DRAWINGS AND CONFORMING TO A NATIONAL TESTING AUTHORITY FOR PERFORMANCE N.T.S. CERTIFICATION. TO BE LOCATED A MINIMUM OF 10' -0" FROM ANY EXHAUST FAN, PLUMBING VENT AND FLUE STACKS. „ 6. ELECTRICAL: c ENS • 1 4 ELECTRICAL HOOK UP AND EQUIPMENT SUCH AS':• �x MOTOR STARTERS, SWITCHES, CONTROLS AND ; Na. 72500 7 COMPONENTS OTHER THAN WHAT IS SPECIFICALLY .-o• '�` '� „ MENTIONED ON DRAWINGS IS BY OTHERS. O.T;• STATE ()P•�; 7. COMPLIANCE: '^'"� '�'''�.`,r, /ONAI.• ° '� „ SYSTEM TO BE MANUFACTURED AND INSTALLED IN \0-;L543 ln111111u��`` O 12" ACCORDANCE WITH NFPA #96, LOCAL FIRE ° PREVENTION BUREAU MECH. AND HEALTH DEPT. =-) I e STANDARDS 7(3,-v Q 710 SOUTH POWERLINE ROAD CHIEF ENGINEER 13