Loading...
08-994-001i � • I Mil i 4 "STANDPIPE 1 I � I RETAIL SPACE NO. 2 SCALE: 1/4" = 1' -0" HANGER LOCATION DETAIL PIPE SIZE A B* C 1. 3' -0" MAX. 12' -0" MAX. 3" MIN. 1 " 4' -0" MAX. 12' -0" MAX. 3" MIN. 1\--8- 5' -0" MAX. 15' -0" MAX. 3" MIN. COMPANY, INC. AND /OR ITS SUBSIDIARIES AND IS LOANED UPON EXPRESS WIRING A B* C' HANGER STEEL PIPE SPRINKLER HEAD • MAXIMUM HANGER SPACING FOR THREADED UGHTWALL STEEL PIPE IS 12' -0' FOR ALL PIPE SIZES IMPORTANT CONTRACT RESPONSIBILITIES IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, IT IS THE OWNER'S ITEM RESP. RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT WET PIPE SPRINKLER SYSTEMS AREAS AND IN ENCLOSURES FOR DRY PIPE DELUGE AND OTHER CITY CONNECTION N . I . C. TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. UNDERGROUND N . I . C THIS DRAWING AND THE INFORMATION AND DESIGN APPLICATION HEREIN EXCAVATIONS N.I.C. CONTAINED IS THE PROPERTY OF GRINNELL FIRE PROTECTION SYSTEMS BACKFILL N.I.C. COMPANY, INC. AND /OR ITS SUBSIDIARIES AND IS LOANED UPON EXPRESS WIRING N.I.C. CONDITIONS THAT THE SAME BE RETURNED TO GFPS UPON REQUEST; ALL ' INFORMATION HEREIN CONTAINED SHALL BE TREATED AS SECRET, AND PAINTING N.I.C. CONFIDENTIAL. NO REPRODUCTION OF THIS DRAWING OR ANY PART NO.. DATE = THEREOF SHALL BE MADE WITHOUT WRITTEN CONSENT OF GFPS. DEsuff im CREATED BY THE GRINNELL DESIGN SYSTEM, "ALL RIGHTS RESERVED ". F ' COPYRIGHT BY GRINNELL CORPORATION 1990. 4 FIRE SPRINKLER DETAIL FP -1 z ofLL- III O �� Ar A R l g EXISTING SPRINKLER DEFLECTOR DETAIL - SECTION VIEW N.T.S. G1 URI EXISTING DROP TO BE REMOVED. ' SCHEDULE 2 1. EXISTING UPRIGHT TO BE REMOVED. 2. EXISTING BRANCHLINE. 3. NEW 11" ARMOVER 4. NEW 1" DROP 5. NEW FIRE SPRINKLER HEAD. U P�—o Q �• ARMOVERS GREATER THAN ® 24" IN LENGTH SHALL BE SUPPORTED BY A HANGER. Typical Rebcation Detail NJ SCALE SCHEDULE 1. EXISTING DROP T•1 BE REMOVED. 2. EXISTING BRANCHJNE. O 2 3. 1' ARMOVER.' 4. 1' DROP. 5. NEW FIRE SPRINKER HEAD 3 4 1 '• ARMOVERS GEATER THAN 24' IN LENGTH HALL BE ® SUPPORTED BY I HANGER. Typical Rel(cation Detail * *.ARMOVERS GREATER THAN 24 IN LENGTH SHALL BE a SUPPORTED BY A HANGER. � � INSPECTOR �� r VERIFY THAT THE PIPE SIZES ILLUST ON THIS SHOP DRAWING MATCHES THE PEE IN THE FIELD, r; N RESPONSEIFINISHI ESCUTCHEON O.R I CHi S.W. 73RD. STREET SITE PLAN NOT TO SCAE MANUF. MODEL STYLE NPT I K ORIFICE 0 CEILING FIT. ABOVE REF. ->*- GATE VALVE(SEE NOTES) Q. ELECTRIC BELL '13 C/L OF PIPE BELOW BOD EM FIRE HOSE ASSEMBLY � WATER MOTOR GONG (WMG) 2 -4 CA OF PIPE ABOVE REF. FLOW SWITCH (FS) FIRE UEPT.CONN.(STANDARD) 10 HYDRAULIC REF. POINT ❑M MONITOR SWITCH --41;- FIRE E)EPT.CONN.(FLUSH) 1 LINE DESIGNATION BUTTERFLY VALVE V FIRE E)EPT.CONN.(SIDEWALK) Al MAIN DESIGNATION ALARM VALVE (ALV) -- POST INDICATOR VALVE (PIV) -� HANGER # DRY PIPE VALVE KEY GATE SECTIONAL VALVE �h- UNION -DI WAFER CHECK VALVE WITH F!OADWAY BOX -0- GROOVED COUPLING (GC) fW SWING CHECK VALVE '9' FIRE HYDRANT (3 WAY) —3 SCREWED CAP ® SYSTEM RISER --6 THRUST BLOCK —� GROOVED CAP -1 INSPECTOR'S TEST ._. + 2&4 WAY SEISMIC BRACING —4 SCREWED PLUG GLOBE VALVE (LO IcH)ELEVA�TION CHANGE IN PIPE -@- FLANGED CONNECTION �' ANGLE VALVE (NOT THROUGH FLOOR) TYCO TY-FM FEM. 11T 5.8 11T TY00 Ty-FM OUT - 1 Z' 56 1 /Z• ' - R, E V I S I O N S r NO.. DATE = BY DEsuff im F ' M4 I FIRE SPRINKLER NOTES Iall piping, heads, hangers and system " TOTAL 19 components to be spaced and installed in f N RESPONSEIFINISHI ESCUTCHEON O.R I CHi S.W. 73RD. STREET SITE PLAN NOT TO SCAE IN ROD COUPLING- _ OWDER DRIVEN aTUID alts' ALL -1 HkiE -AD ROD 4" & SMALLER HANGER RING HANGER NO.1 - NO SCALE - CONCRETE TEE CONSTRUCTION .U�-- CTON— i QUICK BOLT �: EYELET BALL- THREAD ROD HANGER RING HANGER N 0.2 - NO SCALE - (�� SCHEDULE LgJ t 1. NEW BRANCHUNE. 2 2. NEW NIPPLE 3. NEW FIRE SPRINKLER HEAD. 3 FIRE SPRINKLER DETAIL FP -1 N.T.S. I I J l , _. t CO FirC & y .5imp/exGrinne// Security oM.LE VMHLV .u.RgM6RE9ENID LOCAL OFFICE: SimplexGrinne 10550 Commerce Pc Miramar, Florida a Ph: 954- 431 -3100 Fax ABBREVIATIONS BOB BOTTOM OF BEAM BOO BOTTOM ,OF DECK, BOP,,..', BOTTOM OF PIPE' -` c` k 'FDC FIRE DEPL:CONNECTION• HV \'. • HOSE, VALVE H&C ' NIPPLE `AND'CAP " NIC NOT .IN. CONTRACT , NTS ' • NOT. TO SCALE , - ' OBJ OPEN BAR JOIST PRV PRESSURE RED. VALVE RM ROOF MANIFOLD SP STANDPIPE TOB TOP OF BEAM TOP TOP OF PIPE TOS TOP OF STEEL LINO UNLESS NOTED OTHERWISE APPROVALS SPKR PKR. I.D. SYMBOL QTY. O 3 ; OUT" IN ' f OUT IN OUT - YM 5 ' - R, E V I S I O N S r NO.. DATE = BY DEsuff im F ' M4 I FIRE SPRINKLER NOTES Iall piping, heads, hangers and system " TOTAL 19 components to be spaced and installed in f with N.F.P.A.13 IN ROD COUPLING- _ OWDER DRIVEN aTUID alts' ALL -1 HkiE -AD ROD 4" & SMALLER HANGER RING HANGER NO.1 - NO SCALE - CONCRETE TEE CONSTRUCTION .U�-- CTON— i QUICK BOLT �: EYELET BALL- THREAD ROD HANGER RING HANGER N 0.2 - NO SCALE - (�� SCHEDULE LgJ t 1. NEW BRANCHUNE. 2 2. NEW NIPPLE 3. NEW FIRE SPRINKLER HEAD. 3 FIRE SPRINKLER DETAIL FP -1 N.T.S. I I J l , _. SYSTEM INFO NAME/N0. SYSTEM V. ". SYSTEM HAZARD CLASSIFICATION WATER SUPPLY INFORMATION: TEST LOCATION: RETAIL SPACE #2 5829 SW 73rd STREET MIAMI, FLORIDA 33143. CONTRACT NTH: DESCRIPTION: FORE PROTECTION PLAN. DENSITY AREA OF I HOSE SO. FT. TOTAL SYSTEM GPM /SO.FT. APPUC. ALLOW. /1-11). GPM PSI PSI. PSI. GPM BY: MIAN— DADE FIRE TEST DATE: ece* AS NOTE I -alp a° DRAWN BY: ; J.Q,J. ; CHECKED BY- I3.0 L THESE PLANS PREPARED AT: MIF-ZAMAF2. FL ENGINEERING DEPARTMENT ; CONTRACT NO: a <� DATE: 8/13/08 . DRAWING NO' FP-01 OF 1 10 i I " 1 J M4 I FIRE SPRINKLER NOTES Iall piping, heads, hangers and system " components to be spaced and installed in f with N.F.P.A.13 Iaccordance ABTA OF WORK provisions shall be made to drain all porti6hs-- of the system. ITHIS PERMIT aboveground piping 1"— 2" to be threaded,; XL pipe with cast iron fittings(or approved.,;- acceptable equal). , I piping 2 1/2" and above to be grooved sah. 10 w/ grooved, fit or welded fittings (or';%, Iapproved ,. acceptable equal). layout in finished areas to be coordinated�in I the field with regard to soffit and ceiling conditions. ; sprinkler heads to be spaced at 130 sq. ft.� max. for ordinary hazard areas, 225 sq. ft. max. for light hazard areas. s existing piping -- new piping , M Tdenotes new mech tee. •� I„I denotes exist. sprinkler head to remdin.', denotes new sprinkler hds. BY APPROVED MI COM FIRE DEPARTM Etff �'�I denotes exist.sprinkler hds. to be relocated. T-DADS N.-SITE �� I enotes exist.sprinkler hds. to be removed. SPK_ - -- _-BLDG. PERMIT WATER I EX SI DATEPi 09 BY SYSTEM INFO NAME/N0. SYSTEM V. ". SYSTEM HAZARD CLASSIFICATION WATER SUPPLY INFORMATION: TEST LOCATION: RETAIL SPACE #2 5829 SW 73rd STREET MIAMI, FLORIDA 33143. CONTRACT NTH: DESCRIPTION: FORE PROTECTION PLAN. DENSITY AREA OF I HOSE SO. FT. TOTAL SYSTEM GPM /SO.FT. APPUC. ALLOW. /1-11). GPM PSI PSI. PSI. GPM BY: MIAN— DADE FIRE TEST DATE: ece* AS NOTE I -alp a° DRAWN BY: ; J.Q,J. ; CHECKED BY- I3.0 L THESE PLANS PREPARED AT: MIF-ZAMAF2. FL ENGINEERING DEPARTMENT ; CONTRACT NO: a <� DATE: 8/13/08 . DRAWING NO' FP-01 OF 1