10-1175-004•Ii LEGEND
ADDITIM, IM► COSWTION
FOLIO: M-4036-020-0010 ADDRESS: 5821 SW 11 TESS
•
5UBDIVISION: FAIRGLADE PA PLAT BOOK- 45-W PAGE:
ADJACENT GRADE
?owa U
LOW DENSITY 51NGLE FAMILY RESIDENCE
8Y DOL
ZONING: SINGLE FAMILY (RS -3)
FRONT (BUILDING LINE)
251-011
REQUIRED
PROPOSED
MINIMUM LOT 51ZE
SIDE - ♦ - EST)
101-011
NET AREA (5a FT.)
10g®0 SF.
10,800 SF.
FRONTAGE (FT)
15
15
OF LOT 2, 5LOCK2,
MINIMUM YARD 5ET5ACK5 (FT.)
FAIRCsLADE PARK',,
REQUIRED
PROPOSED
FRONT (SOUTH -11 TER)
25' -0"
25' -0"
REAR (NORTH)
25' -011
511 -611
SIDE (INTERIOR -WEST)
1' -6 "'
1' -6"
SIDE (INTERIOR -EAST)
11-611
11 -611
MAX. IBUILDING HEIGHT
COUNTY, FLORIDA.
STORIES
2
1
FEET (FROM GRADE)
25' -011
20' -211
MAX. BUILDING GOVERAGE W
FIRST FLOOR
3240 SF (3091.)
3232 SF (29%)
SECOND FLOOR
N.A.
N.A.
MAX. IMPERVIOU5 COVERAGE W
4320 5F `(409.)
4221 SF (399'.)
HOUSE
3232 SF
POOL AND DECK
5315F
DRIVEWAY (EDGING)
195 SF
DRIVEWAY (GRAVEL)
N.A.
PAVERS
269 SF
LAND5CAPE FRONTYARD
IMPERVIOUS
liffilLilij _M
NOTE: TE MITE PROTECTICpl
ALL BUILDINGS SHALL HAVE A PR.E- CONSTRUCTION TREATMENT PROTECTION
AGAINST SUBTERRANEAN TERMITES. THE RULES AND LAWS AS ESTABLISHED
BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES
SHALL BE DEEMED AS APPROVED WITH RESPECT TO PRECONSTRUCTION SOIL
TREATMENT FOR PROTECTION AGAINST SUBTERRANEAN TERMITES. A
CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING
DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE
FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE
TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT 15
IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA
DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."
GENERAL NOTES
ALL DIMENSIONS SHALL BE VERIFIED AT FIELD BY GENERAL CONTRACTOR
SHOULD THERE BE ANY INCONSISTENCY WITH PLAN DIMENSIONS,
ARCHITECT SHALL BE NOTIFIED (WRITTEN) FOR APPROVAL, BEFORE
PROCEEDING WITH WORK
PLANS PART OF THIS SET ARE COMPLIMENTARY. INFORMATION 15 NOT
LIMITED TO ONE PLAN. DRAWINGS AND SPECIFICTATONS ARE INSTRUMENTS
OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT
WI -ETHER THE PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT.
THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR
EXTENSIONS TO T14I5 PROJECT, EXCEPT BY AGREEMENT IN WRITING AND
WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. THESE PLANS WERE
PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AUTHORITIES
FOR REVISION TO COMPLIANCE WITH APPLICABLE BUILDING CODES AND IT
15 THE SOLE RESPONSIBILITY OF THE OWNER AND /OR CONTRACTOR TO
BUILD ACCORDING TO THE DRAWINGS. IF CONTRACTOR AND /OR
SUBCONTRACTOR FIND IT NECESSARY TO DEVIATE FROM THE ORIGINAL
APPROVED PLANS, THEN IT 15 THE CONTRACTOR'S AND THE SUBCONTRACTOR'S
RESPONSIBILITY TO PROVIDE THE ARCHITECT WITH FOUR COPIES OF THE
PROPOSED CHAWGES FOR ARCHITECT'S APPROVAL BEFORE PROCEEDING WITH
THE WORKK,
IN ADDITION THE CONTRACTOR AND SUBCONTRACTOR ARE RESPONSIBLE
FOR PROCURING ALL NECESSARY APPROVALS FOR THE BUILDNG
AUTHORITIES FOR THE PROPOSED CHANGES, BEFORE PROCEEDING
WITH THE WORK THE CONTRACTOR AND SUBCONTRACTOR ARE RESPONSIBLE
FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM THE BUILDING
AUTHORITIES DURING THE EXECUTION. CONTRACTOR TO VERITY ALL EXISTING
ELECTRICAL SERVICE AND COORDINATE WITH OWNER FOR NEW SERVICE
REQUIREMENTS AND CONTRACTOR SHALL INFORM ARCHITECT OF ANY
DISCREPENCIES BEFORE COMMENCING WITH WORK
OWNER / BUILDER AND /OR CONTRACTOR SHALL OBTAIN NECESSARY PERMITS,
LICENSES, AND CERTIFICATIONS AND PAY ALL FEES.
OWNER / BUILDER AND /OR CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT
OF ANY THAT DIFFER OR INTERFERE WITH THOSE SHOWN ON T14I5 PLAN
BEFORE PROCEEDING WITH WORK ALL DIMENSIONS SUPERSEDE SCALED DRAWINGS.
OWNER / BUILDER AND /OR CONTRACTOR TO GUARD AGAINST ANY AND ALL
POSSIBLE HAZARDOUS CONDITIONS (EXPOSED HOT WIRING, ETC) WHICH
MIGHT OCCUR AS A RESULT OF CONSTRUCTION.
OWNER / BUILDER AND /OR CONTRACTOR SHALL BE RESPONSIBLE FOR
IMMEDIATE CLEANING AND REMOVAL. OF ALL DEBRIS UNTIL THE PREMISES
ARE ACCEPTED IN A CLEAN, HABITABLE CONDITION.
OWNER / BUILDER AND /OR CONTRACTOR TO CHALK UP ALL PARTITIONS IN THE FIELD
AND NOTIFY ARCHITECT PRIOR TO CONSTRUCTION. ALL NEW WALL [WILL$ SHALL
BE MADE TO MATCH THICKNESS AND MATERIALS OF ADJACENT CONSTRUCTION,
UNLESS OTHERWISE NOTED.
OWNER / BUILDER AND /OR CONTRACTOR TO NOTIFY ARCHITECT IF BASIC A/C
DUCT SYSTEM INTERFERES WITH INSTALLATION OF LIGHT FIXTURES.
OILIER / BUILDER AND /OR CONTRACTOR SHALL NOT PERMIT UNAUTHORIZED PERSONS
INSIDE THE. CONSTRUCTION AREA
OWNER / BUILDER AND /OR CONTRACTOR TO INSTALL BARRIERS AND DROP TARPAULINS
AS NECE55ARY AND REQUIRED AROUND PERIMETER OF CONSTRUCTION LIMITS TO
PROTECT THE PUBLIC. FINISHES MUST BE PROTECTED AND ANY FINISHES DAMAGES
SHALL BE REPLACED BY CONTRACTOR IMMEDIATELY. CONTRACTOR SHALL MAINTAIN
A DUMPSTER AT A SITE DETERMINED BY BUILDING MANAGEMENT FOR THE ENTIRE
DURATION OF CONSTRUCTION.
48 HOURS BEFORE ,016;aIN(S
CALL TOLL Ft e=_
1- 09/X/- 432-4770
UN.C.L.EE UNOFRI sROUNO UTIL l TIES
NOTIFICATION CENTER wo
TREE NOTE:
EXISTING TREES TO REMAIN UNDISTURBED. PROVIDE A 10' -0"
BARRIER AROUND ALL EXISTING TREES. NO MACHINERY,
CHEMICALS, MATERIALS, EQUIPMENT, FILL AND /OR PEOPLE TO BE
WITHIN PERIMETER OF BARRIER AT ANY TIME DURING
CONSTRUCTION-
DEMOLITION NOTES
CONTRACTOR SHALL PROVIDE PROTECTION OF MATERIALS DURING ALL
PHASES OF CONSTRUCTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR IMMEDIATE GLEANING AND
REMOVAL OF ALL DEBRIS UNTIL THE PREMISES ARE ACCEPTED IN A
CLEAN AND HABITABLE CONDITION BY THE ARCHITECT /
INTERIOR DESIGNER
CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL WORK OF
ALL TRADES SHALL COMPLY WITH THE FLORIDA BUILDING
CODES.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN
THE FIELD AND SHALL IMMEDIATELY NOTIFY THE ARCH. /DESIGNER
OF ANY THAT DIFFER OR INTERFERES WITH THOSE SHOWN
ON THIS PLAN BEFORE PROCEEDING WITH WORK ALL DIMENSIONS
SUPERSEDE SCALED DRAWINGS.
THE GENERAL CONTRACTOR, HIS SUB - CONTRACTOR, OR ANY OTHER
CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT
ANY COST CAUSED BY DEFECTIVE WORK, AS A RESULT OF, BUT NOT
LIMITED TO INFERIOR WORIC tANSHIP OR MATERIALS, IMPROPER
SCHEDULING OR DELINQUENT ORDERING SHALL BE BORNE BY PARTY
RESPONSIBLE.
ALL ITEMS DAMAGED WHILE IN DEMOLITION PHASE THAT ARE TO
REMAIN SHALL BE RESTORED OR REPLACED TO BE ACCEPTABLE
BY THE ARCHITECT / INTERIOR DESIGNER AT THE CONTRACTORS
EXPENSE.
ANY OTHER ITEMS OR MATERIALS ENCOUNTERED DURING THE
DEMOLITION PHASE SHALL BE REPORTED IMMEDIATELY TO THE
ARCHITECT / INTERIOR DESIGNER FOR EVALUATION.
NOTE : DRAINAGE
SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN
SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE
SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE FIRST 10
FEET (3048 MM).
EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL WITHIN
10 FEET (3048 MM), THE FINAL GRADE SHALL SLOPE AWAY FROM
THE FOUNDATION AT A MINIMUM SLOPE OF 5 PERCENT AND THE
WATER SHALL BE DIRECTED TO DRAINS OR SWALES TO ENSURE
DRAINAGE AWAY FROM THE STRUCTURE. SWALES SHALL BE
SLOPED A MINIMUM OF 2 PERCENT WHEN LOCATED WITHIN 10 FEET
(3048 MM) OF THE BUILDING FOUNDATION. IMPERVIOUS SURFACES
WITHIN 10 FEET (3048 MM) OF THE BUILDING FOUNDATION SHALL BE
SLOPED A MINIMUM OF 2 PERCENT AWAY FROM TE BUILDING.
`r I
MIN
i -
/ z
KEEP
i
WE
ooelw=c,•,• 1 I%J = 1500 1
SI.0 71TN 1"ERRACE
EXISTINumn SITE F LA �I� ��� •rte . -�� ��
SCALE : 3/32" = 1' -0"
U 7 11
6.W. 11TH i
logo lliilrlqq�
mmlo
8Y DOL
PROPOSED
FRONT (BUILDING LINE)
251-011
REAR (NORTH)
>
351-1011
SIDE - ♦ - EST)
101-011
0 o
SIDE (INTERIOR-EAST)
101-011
o it
NOTE: TE MITE PROTECTICpl
ALL BUILDINGS SHALL HAVE A PR.E- CONSTRUCTION TREATMENT PROTECTION
AGAINST SUBTERRANEAN TERMITES. THE RULES AND LAWS AS ESTABLISHED
BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES
SHALL BE DEEMED AS APPROVED WITH RESPECT TO PRECONSTRUCTION SOIL
TREATMENT FOR PROTECTION AGAINST SUBTERRANEAN TERMITES. A
CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING
DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE
FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE
TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT 15
IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA
DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."
GENERAL NOTES
ALL DIMENSIONS SHALL BE VERIFIED AT FIELD BY GENERAL CONTRACTOR
SHOULD THERE BE ANY INCONSISTENCY WITH PLAN DIMENSIONS,
ARCHITECT SHALL BE NOTIFIED (WRITTEN) FOR APPROVAL, BEFORE
PROCEEDING WITH WORK
PLANS PART OF THIS SET ARE COMPLIMENTARY. INFORMATION 15 NOT
LIMITED TO ONE PLAN. DRAWINGS AND SPECIFICTATONS ARE INSTRUMENTS
OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT
WI -ETHER THE PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT.
THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR
EXTENSIONS TO T14I5 PROJECT, EXCEPT BY AGREEMENT IN WRITING AND
WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. THESE PLANS WERE
PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AUTHORITIES
FOR REVISION TO COMPLIANCE WITH APPLICABLE BUILDING CODES AND IT
15 THE SOLE RESPONSIBILITY OF THE OWNER AND /OR CONTRACTOR TO
BUILD ACCORDING TO THE DRAWINGS. IF CONTRACTOR AND /OR
SUBCONTRACTOR FIND IT NECESSARY TO DEVIATE FROM THE ORIGINAL
APPROVED PLANS, THEN IT 15 THE CONTRACTOR'S AND THE SUBCONTRACTOR'S
RESPONSIBILITY TO PROVIDE THE ARCHITECT WITH FOUR COPIES OF THE
PROPOSED CHAWGES FOR ARCHITECT'S APPROVAL BEFORE PROCEEDING WITH
THE WORKK,
IN ADDITION THE CONTRACTOR AND SUBCONTRACTOR ARE RESPONSIBLE
FOR PROCURING ALL NECESSARY APPROVALS FOR THE BUILDNG
AUTHORITIES FOR THE PROPOSED CHANGES, BEFORE PROCEEDING
WITH THE WORK THE CONTRACTOR AND SUBCONTRACTOR ARE RESPONSIBLE
FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM THE BUILDING
AUTHORITIES DURING THE EXECUTION. CONTRACTOR TO VERITY ALL EXISTING
ELECTRICAL SERVICE AND COORDINATE WITH OWNER FOR NEW SERVICE
REQUIREMENTS AND CONTRACTOR SHALL INFORM ARCHITECT OF ANY
DISCREPENCIES BEFORE COMMENCING WITH WORK
OWNER / BUILDER AND /OR CONTRACTOR SHALL OBTAIN NECESSARY PERMITS,
LICENSES, AND CERTIFICATIONS AND PAY ALL FEES.
OWNER / BUILDER AND /OR CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS IN THE FIELD AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT
OF ANY THAT DIFFER OR INTERFERE WITH THOSE SHOWN ON T14I5 PLAN
BEFORE PROCEEDING WITH WORK ALL DIMENSIONS SUPERSEDE SCALED DRAWINGS.
OWNER / BUILDER AND /OR CONTRACTOR TO GUARD AGAINST ANY AND ALL
POSSIBLE HAZARDOUS CONDITIONS (EXPOSED HOT WIRING, ETC) WHICH
MIGHT OCCUR AS A RESULT OF CONSTRUCTION.
OWNER / BUILDER AND /OR CONTRACTOR SHALL BE RESPONSIBLE FOR
IMMEDIATE CLEANING AND REMOVAL. OF ALL DEBRIS UNTIL THE PREMISES
ARE ACCEPTED IN A CLEAN, HABITABLE CONDITION.
OWNER / BUILDER AND /OR CONTRACTOR TO CHALK UP ALL PARTITIONS IN THE FIELD
AND NOTIFY ARCHITECT PRIOR TO CONSTRUCTION. ALL NEW WALL [WILL$ SHALL
BE MADE TO MATCH THICKNESS AND MATERIALS OF ADJACENT CONSTRUCTION,
UNLESS OTHERWISE NOTED.
OWNER / BUILDER AND /OR CONTRACTOR TO NOTIFY ARCHITECT IF BASIC A/C
DUCT SYSTEM INTERFERES WITH INSTALLATION OF LIGHT FIXTURES.
OILIER / BUILDER AND /OR CONTRACTOR SHALL NOT PERMIT UNAUTHORIZED PERSONS
INSIDE THE. CONSTRUCTION AREA
OWNER / BUILDER AND /OR CONTRACTOR TO INSTALL BARRIERS AND DROP TARPAULINS
AS NECE55ARY AND REQUIRED AROUND PERIMETER OF CONSTRUCTION LIMITS TO
PROTECT THE PUBLIC. FINISHES MUST BE PROTECTED AND ANY FINISHES DAMAGES
SHALL BE REPLACED BY CONTRACTOR IMMEDIATELY. CONTRACTOR SHALL MAINTAIN
A DUMPSTER AT A SITE DETERMINED BY BUILDING MANAGEMENT FOR THE ENTIRE
DURATION OF CONSTRUCTION.
48 HOURS BEFORE ,016;aIN(S
CALL TOLL Ft e=_
1- 09/X/- 432-4770
UN.C.L.EE UNOFRI sROUNO UTIL l TIES
NOTIFICATION CENTER wo
TREE NOTE:
EXISTING TREES TO REMAIN UNDISTURBED. PROVIDE A 10' -0"
BARRIER AROUND ALL EXISTING TREES. NO MACHINERY,
CHEMICALS, MATERIALS, EQUIPMENT, FILL AND /OR PEOPLE TO BE
WITHIN PERIMETER OF BARRIER AT ANY TIME DURING
CONSTRUCTION-
DEMOLITION NOTES
CONTRACTOR SHALL PROVIDE PROTECTION OF MATERIALS DURING ALL
PHASES OF CONSTRUCTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR IMMEDIATE GLEANING AND
REMOVAL OF ALL DEBRIS UNTIL THE PREMISES ARE ACCEPTED IN A
CLEAN AND HABITABLE CONDITION BY THE ARCHITECT /
INTERIOR DESIGNER
CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL WORK OF
ALL TRADES SHALL COMPLY WITH THE FLORIDA BUILDING
CODES.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN
THE FIELD AND SHALL IMMEDIATELY NOTIFY THE ARCH. /DESIGNER
OF ANY THAT DIFFER OR INTERFERES WITH THOSE SHOWN
ON THIS PLAN BEFORE PROCEEDING WITH WORK ALL DIMENSIONS
SUPERSEDE SCALED DRAWINGS.
THE GENERAL CONTRACTOR, HIS SUB - CONTRACTOR, OR ANY OTHER
CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT
ANY COST CAUSED BY DEFECTIVE WORK, AS A RESULT OF, BUT NOT
LIMITED TO INFERIOR WORIC tANSHIP OR MATERIALS, IMPROPER
SCHEDULING OR DELINQUENT ORDERING SHALL BE BORNE BY PARTY
RESPONSIBLE.
ALL ITEMS DAMAGED WHILE IN DEMOLITION PHASE THAT ARE TO
REMAIN SHALL BE RESTORED OR REPLACED TO BE ACCEPTABLE
BY THE ARCHITECT / INTERIOR DESIGNER AT THE CONTRACTORS
EXPENSE.
ANY OTHER ITEMS OR MATERIALS ENCOUNTERED DURING THE
DEMOLITION PHASE SHALL BE REPORTED IMMEDIATELY TO THE
ARCHITECT / INTERIOR DESIGNER FOR EVALUATION.
NOTE : DRAINAGE
SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN
SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE
SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE FIRST 10
FEET (3048 MM).
EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL WITHIN
10 FEET (3048 MM), THE FINAL GRADE SHALL SLOPE AWAY FROM
THE FOUNDATION AT A MINIMUM SLOPE OF 5 PERCENT AND THE
WATER SHALL BE DIRECTED TO DRAINS OR SWALES TO ENSURE
DRAINAGE AWAY FROM THE STRUCTURE. SWALES SHALL BE
SLOPED A MINIMUM OF 2 PERCENT WHEN LOCATED WITHIN 10 FEET
(3048 MM) OF THE BUILDING FOUNDATION. IMPERVIOUS SURFACES
WITHIN 10 FEET (3048 MM) OF THE BUILDING FOUNDATION SHALL BE
SLOPED A MINIMUM OF 2 PERCENT AWAY FROM TE BUILDING.
`r I
MIN
i -
/ z
KEEP
i
WE
ooelw=c,•,• 1 I%J = 1500 1
SI.0 71TN 1"ERRACE
EXISTINumn SITE F LA �I� ��� •rte . -�� ��
SCALE : 3/32" = 1' -0"
U 7 11
6.W. 11TH i
logo lliilrlqq�
mmlo
SCALE — 3/32" = 1' -0"
t
': /
s�f
1
1
INE
VERIFY
R TO
SEE
TS FOR
'ION
LEGEND
8Y DOL
lllw.�
ul
GRAVEL
>
CONCRETE PAVER (SEE SHEET A -30 t A -IJ FOR INFORMATION
ON SIZE AND LOCATION.
THE EAST 20 FEET OF LOT
3 AND THE WEST 55 FEET
OF LOT 2, 5LOCK2,
FAIRCsLADE PARK',,
ACCORD NG TO THE PLAT
THEROF RECORDED IN
Q
PLAT BOOK 45 AT PAGE
d) it)
80 OF THE PUBLIC
RECORDS OF DADE
COUNTY, FLORIDA.
NOR114
t,17
SCALE — 3/32" = 1' -0"
t
': /
s�f
1
1
INE
VERIFY
R TO
SEE
TS FOR
'ION
LEGEND
8Y DOL
IMSCRIPTION
TO BE DEMOLISHED OR REMOVED
GRAVEL
El
CONCRETE PAVER (SEE SHEET A -30 t A -IJ FOR INFORMATION
ON SIZE AND LOCATION.
100% CONSTRUCT10N
DOCUMENTS
Revisions I