Loading...
11-65-011r � J PA P1 ,,H�0�4 R ON t %REG�►,) P�f SOH X005 U0'� ° r 20 (N) 2 �1y z 3�k (0 i I 0kW. °'� $ DENOTE POINT OF CONINECTION' T WATIER i i'IETRIC M1 x 5 f^ ¢V folo h s 0) ) ), =;� I)LN6 T POINT OF CONNECTION 1-01* 115 y VIc SANITARY ISOMETRIC 3 "OS, TO B T STORAGE TANK EKH INSTALLED OVER CEILING 314' TO OL 2 1 5 314" MIN. RELEASE LINE TO DRAIN THRU WATER HEATER PAN DRAIN HEAT TRAP PER ENERGY CODE TO ABSURB THERMAL EXPANSION. HOT WATER SUPPLY LINE 112 "0 THERMAL EXPANSION DEVICE. EMBLEM AND RATING PLATE ELECTRICAL ACCESS PANELS GAL V STEEL (24 Go) WATER HEATER PAN (OMIT ON GROUND FLR.) 1 -112" DEEP 314 "0 CPVC MIN. PAN DRAIN TO RUN OUTSID UNDER SLAG TEMPERATURE AND PRES. RELIEF VALVE SHUTOFF VALVE UNION ELECTRICAL JUNCTION BOX ELECT. CONN. DRAIN VALVE HOSE y CONNECTION HOT WATER HEATER DE TAIL N.T.S. N. T S. EWH AQSMITH ELSC -20S 3000 WATTS CAPACITY 20 GALLONS ENERGY EFFICENCY 0.94 MIN. NOTE: ALL SANITARY PIPE 2 112 "0 OR SMALLER SHALL RUN 0 114" SLOPE PER L.FT. 3" AND LARGER 4 118" SLOPE PER L.FT. i \ i / 1 E: ALL TUB AND SHOWER SHALL BE ANTISCALDING VALVE 0 110; (TYPICAL) MAXIMUM FLOW RATE WATER PIPING :SI%E -'?. FOR PLUMBING FIX'T'URES, FIXTURE FITTINGS 1% "0 CWIHW a 112"0 CW Q 3/4 "0 CW,1 j2 "O HW Q 314"0 CW/HW 0.5 GPM 0 60 PSI 314 "0 C NOTE: ALL SANITARY PIPE 2 112 "0 OR SMALLER SHALL RUN 0 114" SLOPE PER L.FT. 3" AND LARGER 4 118" SLOPE PER L.FT. i \ i / 1 E: ALL TUB AND SHOWER SHALL BE ANTISCALDING VALVE 0 110; (TYPICAL) MAXIMUM FLOW RATE AND CONSUMPTION FOR PLUMBING FIX'T'URES, FIXTURE FITTINGS AND APPLIANCES. EDITION (FB.C.2007), FEDERAL ORDINANCES GOVERNING THE PLUMBING FTX'i`URE MAXBfU1i FLOW RATE OR FDUURE Fi =G OR QUANTffY LAVATORY, PRIVATE 1.0 GPM 0 60 PSI LAVATORY, PUBLIC, (METERING) 0.25 GALLON PER METERING CYCLE LAVATORY, PUBLIC 0.5 GPM 0 60 PSI (OTHER THAN METERING) ARCHITECT %ENGINEER. WILL THEN ISSUE INSTRUCTIONS AS SHOWER HEAD 1.5 GPM G) 80 PSI SINK FAUCET 1.0 GPM 0 60 PSI URINAL WATERLESS OR 0.5 GALLON PER �� SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FLUSHING CYCLE WATER CLOSET 1.28 GALLON PER FLUSHING CYCLE DISHWASHER (RESIDENTIAL) 6.5 GALLON PER CYCLE OR LESS 70. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL (ENERGY STAR /WATER SENSE CERTIFIED) DISHWASHER (COMMERCIAL) LESS THAN 1.2 GALLONS PER RACK SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS, FOR FILL AND DUMP MACHINES AND CLOTHES WASHER LESS THAN 0.9 GALLONS PER RACK 71., PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS FOR ALL OTHER TYPES OF MACHINES. UNDER THE COUNTER MACHINES 1.0 GALLONS OR LESS PER RACK FOR TO THE OWNER. HIGH- TEMPERATURE MACHINES AND FLOOR DRAINS 1.7 GALLONS PER RACK FOR LOW - 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL TEMPERATURE MACHINES, WASHING MACHINE WATER FACTOR OF 8 OR LO'rr'ER OF FINAL WORK ACCEPTANCE BY OW'N'ER. ANY BREAKDOWN (ENERGY STARIWATER SENSE CERTIFIED) FOR SI: 1 GALLON = 3.785 L. 1 GALLON PER MINUTE = 3.785 L1m 1 POUND PER SQUARE INCH = 6.895 kPa. o. A HAND -HELD SHOWER .SPRAY IS A SHOWER HEAD. b. CONSUMPTION TOLERANCES SHALL BE DETERMINED FROM REFERENCED STANDARDS. c. WATER FACTOR IN GALLONS PEP. CYCLE PER CUBIC FOOT GENERAL PLUMBING NOTES ,I 1. ALL WORK SHALL CONFORM WITH FLORIDA BUILDING CODE 2001 PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR EDITION (FB.C.2007), FEDERAL ORDINANCES GOVERNING THE ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS RULES OR ORDINANCES WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, TUB THE CONTRACTOR SHALL REPORT IN WRITING TO THE 7. PROVIDE MEANS "FURNISH AND INSTALL ". ARCHITECT /ENGINEER. BEFORE SUBMITTING A BID. THE WHIRLPOOL ARCHITECT %ENGINEER. WILL THEN ISSUE INSTRUCTIONS AS 8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. POW TO PROCEED. BIDET 1 -114" 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT �� SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE FOR APPROVAL BY PROPER AUTHORITIES MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE KITCHEN SINK STRUCTURAL ARCHITECTURAL. AND SITE. CONDITIONS SHALL 70. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL GOVERN LOCATIONS: CONTRACTOR SHALL FOLLOW GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS WORK, CHECK DRAEXACT DRAWINGS IN LAYING OUT 1-'�INGS OF ALL SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS, TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED CLOTHES WASHER AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS 71., PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS AT ALL POINTS. WHERE HEAD ROOM, OR .SPACE .CONDITIONS REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE TO THE OWNER. NOTIFIED BEFORE PROCEEDING WfTH INSTALLATION. THIS FLOOR DRAINS CONTRACTOR SHALL, WTHOUT EXTRA CHARGE, MAKE FIELD 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE WITH WORK OF VARIOUS TRADES DR FOR PROPER EXECUTION OF FINAL WORK ACCEPTANCE BY OW'N'ER. ANY BREAKDOWN OF THE WORK .. OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. 13• PROVIDE BATHROOM FIXTURES AS SPECIFIED OR AS .SELECTED BY CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL ANDIOR OWNER AND TO COMPLY W/F.B.C.2007 SPECIALLY CHAPTER 11, COtJNLCT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS SHOWN ON ANY OF TLIE ARCHITECTURAL, AIR CONDITIONING, 14. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE. ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. DISCREPANCIES , CONFLICTS , 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DIELECTRIC INTERFERENCE INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, FIT77NG SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. NOTIFY IN WRITING THE ARCHITECT/ ENGINEER. IN AMPLE TIME TO PERMIT REVISIONS. BEFFORE THE BIDS ARE SUBMITTED. 16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST FOR LOCATION OF UNITS AND DRAINS. CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE 17. ALL SANITARY FITTINGS SHALL BE DIREC77ONAL TYPE. RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS W41CH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE 18. MATERIALS APPEARANCE. REMOVAL AND REPLACEMENT 1.S TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT A. COLD 4 "r'ATER PIPING DOWNSTREAM OF WATER b;EIER SHALL BE "L" THE SOLE EXPENSE OF CONTRACTOR. TYPE COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE. GROUND. B. COLD WATER PIPES INSIDE OF SLABS SHALL BE TYPE "K" SOFT COPPER 5. OF WORK CONTRACTOR SHALL CONSIDERED A5 INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB. CCEP I ACCEPTANCE $Y HIM OF ALL CLAIMS OR QUESTIONS AS TO E C. SANITARY WASTE AND VENT 4 "0 AND SMALLER SHALL BE CAST IRON PIPE. SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER D. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER, CONTRACTORS TO RECEIVE HIS WORK. THIS 'CONTRACTOR MIN. 3/4" DIA, SHALL REMOVE AND REPLACE AT HIS EXPENSE, ALL PLUMBING WORK K141CH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, I=LLS, PLRMITS ,. ASSOCIATION DUES, ROYALTIES AND TAXES OF WATEVER NATURE SHALL APPLY TO THIS WORK, HE SHALL ALSO SCOPE OF WORK: THIS IS AN EXISTING SPACE WITH AN INTERIOR ALTERATION (SEE ARCH. PLANS). THE EXISTING BATHROOM WILL BE REMODELED AS SHOWN AND 3 NEW SINKS ARE PROPOSED IN EXAM ROOM. ADJACENT TENANT r ...,�_, FLUM51NG FLAN SCALD: 1/4" = 1'-O" ADJACi -hT TENANT FIXTURE CONNECTION SCHEDULE ,I ITEM WASTE & SOIL WATER COLD HOT WATER CLOSET 3" 318" -- - TUB 2" 112" 112- WHIRLPOOL 2" ................ ....... -..... .... 112" 112" BIDET 1 -114" .318" 318" LAVATORY 1- 114" 318" 318" KITCHEN SINK 1 -112" 112" 112" DISHWASHER 1" hose _ _ 112 - CLOTHES WASHER 3" 112" 112" HOSE BIBB _ _ 112" _ FLOOR DRAINS 2" MIN. 112" - - SHOWER 2" 112" 112" REFRIGERATOR -- 318" -- - NOTE. PROVIDE ANTI SCALD VALVE 0 EACH SHOWER AND TUB NOTE: ALL TRAPS SHALL BE CONSISTENT W /FIXTURE OUTLET SIZE. HAMMER ARRESTOR: - AMTROL, MODEL 500 - INSTALL IN ACC. LOCATION. -- CONNECTION SIZE: 112" NPT - HEIGHT: 4-112" - DIAMETER: 3 -3/8" MAX. PRESSURE: 150 PSI MAX. TEMP: 200' F MAX. SHOCK PRESSURE. 200 PSI .TS., R N • ►,Z y C ,I tr 4 GIklClrfi �a�ma�la� I P.E. No 53288 Jose Antonio Mendez. Professional Engineer m 1 M ID 0 NA 1395 Corsi Way Suite *203 Miami. FL, 33145 �m��l&�II�Q�� ��� PH:(305454 -9924 FAX(3051856 -1797 J•se0119caaeLcim CA 00009324 ••Ii •lii • i oQueo • ••i • • • •• •u ti • •Ili • u • u • a. • • • • • �, • BLITSTEIN DESIGN to • age 0 & 0 •t+i• • Ns • L s • i • • • 1, 6`A tr 4 E- ._ _. molts; !ti it ■t ■i �E!/sNSE BLITSTEIN DESIGN to • age 0 & 0 •t+i• • Ns • L s • i • • • 1, 6`A ASSOCIATES Architecture Interior Design 28S Sevilla Avenue Coral Q"ek F 33134 (303) 4 -4433 Fax (3015) 444 -0181 imnlobehouduut EMAL- PETER BLITSTEIN LIC. No. - ARD007570 Y� I •�. i project name . New Store Br: SEE, INC., 5525 SUNSET DRIVE SOUTH MIAMI, Ff. 33143 project number date 01 -12 -11 revision drawn by M.S. sheet titie SCALE: AS SHOWN sheet number s i a a 1L tr 4 ASSOCIATES Architecture Interior Design 28S Sevilla Avenue Coral Q"ek F 33134 (303) 4 -4433 Fax (3015) 444 -0181 imnlobehouduut EMAL- PETER BLITSTEIN LIC. No. - ARD007570 Y� I •�. i project name . New Store Br: SEE, INC., 5525 SUNSET DRIVE SOUTH MIAMI, Ff. 33143 project number date 01 -12 -11 revision drawn by M.S. sheet titie SCALE: AS SHOWN sheet number s i a a 1L