10-938-014FRONT TOWER ELEVATION 3/4"
717.2 FIREBLOCKING.
IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE INSTALLED TO CUT
OFF CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND
SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY
AND A ROOF OR ATTIC SPACE. FIREBLOCKING SHALL BE INSTALLED IN THE
LOCATIONS SPECIFIED IN SECTIONS THROUGH .
717.2.1 FIREBLOCKING MATERIALS.
FIREBLOCKING SHALL CONSIST OF 2 --INCH (51 MM) NOMINAL LUMBER OR TWO
THICKNESSES OF 1-INCH (25 MM) NOMINAL LUMBER WITH BROKEN LAP JOINTS
OR ONE THICKNESS OF 0.719 -INCH (18.3 MM) WOOD STRUCTURAL PANEL WITH
JOINTS BACKED BY 0.719 -INCH (18.3 MM) WOOD STRUCTURAL PANEL OR ONE
THICKNESS OF 0.75 -INCH (19 MM) PARTICLEBOARD WITH JOINTS BACKED BY
0.75 -INCH (19 MM) PARTICLEBOARD. GYPSUM BOARD, CEMENT FIBER BOARD,
BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER OR OTHER APPROVED
MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN
PLACE SHALL BE PERMITTED AS AN ACCEPTABLE FIREBLOCK. BATTS OR
BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED NONRIGID
MATERIALS SHALL BE PERMITTED FOR COMPLIANCE WITH THE 10 —FOOT (3048
MM) HORIZONTAL FIREBLOCKING IN WALLS CONSTRUCTED USING PARALLEL ROWS
OF STUDS OR STAGGERED STUDS. LOOSE —FILL INSULATION MATERIAL SHALL NOT
BE USED AS A FIREBLOCK UNLESS SPECIFICALLY TESTED IN THE FORM AND
MANNER INTENDED FOR USE TO DEMONSTRATE ITS ABILITY TO REMAIN IN PLACE
AND TO RETARD THE SPREAD OF FIRE AND HOT GASES. THE INTEGRITY OF
FIREBLOCKS SHALL BE MAINTAINED.
osf• rf•
•Yf • ti
• • •
r • G •
• f •GOf• uGl'i
i• cc w • •
U ! U G V
• f • c:Gf1vG
! • r { U
f 4 Yi•• f u •
717.2.1.1 DOUBLE STUD WALLS. • • Gf •
U Y Y U
r Y G h • Y, G• ! • •
BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER 1APF1POVrDt, :•: •,'
I,iONRIGID MATERIALS SHALL BE ALLOWED AS FIREBLOCKING IN•VALLS
CONSTRUCTED USING PARALLEL ROWS OF STUDS OR STAGGERED STUDS.
Off• i•ucv e,or rt• S
• w • • r
fell* r i • •
717.2.2 CONCEALED WALL SPACES. •
Vrlr • G•f •r • •!• U if'
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND
PARTITIONS, INCLUDING FURRED SPACES, AND PARALLEL ROWS OF STUDS OR
STAGGERED STUDS, AS FOLLOWS:
A. VERTICALLY AT THE CEILING AND FLOOR LEVELS.
B. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET (3048 MM).
717.2.3 CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES.
FIREBLOCKING SHALL
BE
PROVIDED
AT INTERCONNECTIONS BETWEEN CONCEALED
VERTICAL
STUD WALL
OR
PARTITION
SPACES AND CONCEALED HORIZONTAL
SPACES
CREATED BY
AN
ASSEMBLY
OF FLOOR JOISTS OR TRUSSES, AND
BETWEEN
CONCEALED
VERTICAL AND
HORIZONTAL SPACES SUCH AS OCCUR AT
SOFFITS,
DROP CEILINGS,
COVE CEILINGS AND SIMILAR LOCATIONS.
FLORIDA BUILDING CODE
3
X21' -2"
T.O.P. —
AIN A MIN
A'X 1:1
:N TOP OF
AND
VIDTH.
,1
T.Q.P.
(EXIST)
T.O. WINDOW
EXIST ELEV
SOUTH FliIAMI!
DING DEPT.
1'URAL SECTION,,
PROJECT N°: 10 - 233
c °'
U w
co aw=
o mmr
cn <<w
cn ko co '00
c � o Lo ~<w
�i
co o 0 cat s En (G I c) z
.-, i <o
v in to
5 a ZOW
rn 4-)�soo S
.,
r- o L � 0<�
to
J (n
►D i`- OW <Nw
Ga r+ E- Fs, U z L
5a
x
ow
0_
a�
Dr
m:D
LL
OZ
CIO
w�
am
w a n`.
a
J?
1 w 0
ELI J
wJ
TO
ff W�
<Z
VI w
00
()ZO
F�❑
<`°
mo
W a�
H `rj m
Z < 0
SZZ
(ngw
O(f)U
aw>
mom
� w
m - Ul
4-1
ago
U
oWf�fl
.N
F-L-Z
= =w
O
I-
oQf� �
�<
a_
}�
°1Z
U
UF—
LL
0
LL
75
Q
°
°
w
_W
°
°
I-
o
U)
o
0
o
CONTRACT DATE: xxxxXX
(c)
BUILDING
TYPE: K38
N
co
PLAN VERSION: Jan 08
L0
SITE NUMBER: XXX -XXX
.r.l
W
TORE NUMBER: K478006
0
KFC
2
W
5826 SW 40 STREET
SOUTH MIAMI, FLORIDA
Z
0
co
U
LL
K38 REMODEL
'
TOWER
ELEVATIONS
FIN. FL I A4,2
t_
PLOT DATE.
RIGHT SIDE TOWER ELEVATION 3/4"
OC 1 0 5 "lulu
08 -02 -1(
w
ti
0