10-938-003FLORIDA BUILDING CODE 2007 CHAPTER 10 - BUILDING CODE NOTES: 1003.3 PROTRUDING OBJECTS. PROTRUDING OBJECTS SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS THROUGH 1003.3.1 HEADROOM. PROTRUDING OBJECTS ARE PERMITTED TO EXTEND BELOW THE MINIMUM CEILING HEIGHT REQUIRED BY SECTION PROVIDED A MINIMUM HEADROOM OF 80 INCHES (2032 MM) SHALL BE PROVIDED FOR ANY WALKING SURFACE, INCLUDING WALKS, CORRIDORS, AISLES AND PASSAGEWAYS, NOT MORE THAN 50 PERCENT OF THE CEILING AREA OF A MEANS OF EGRESS SHALL BE REDUCED IN HEIGHT BY PROTRUDING OBJECTS. EXCEPTION: DOOR CLOSERS AND STOPS SHALL NOT REDUCE HEADROOM TO LESS THAN 78 INCHES (1981 MM). A BARRIER SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES (2032 MM) HIGH, THE LEADING EDGE OF SUCH A BARRIER SHALL BE LOCATED 27 INCHES (686 MM) MAXIMUM ABOVE THE FLOOR. 1003.3.2 FREE - STANDING OBJECTS. A FREE- STANDING OBJECT MOUNTED ON A POST OR PYLON SHALL NOT OVERHANG THAT POST OR PYLON MORE THAN 12 INCHES (305 MM) WHLRL THE LOWEST POINT OF THE LEADING EDGE IS MORE THAN 27 INCHES (686 MM) AND LESS THAN 80 INCHES (2032 MM) ABOVE THE WALKING SURFACE, WHERE A SIGN OR OTHER OBSTRUCTION IS MOUNTED BETWEEN POSTS OR PYLONS AND THE CLEAR DISTANCE BETWEEN THE POSTS OR PYLONS IS GREATER THAN 12 INCHES (305 MM), THE LOWEST EDGE OF SUCH SIGN OR OBSTRUCTION SHALL BE 27 INCHES (685 MM) MAXIMUM OR 80 INCHES (2030 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. EXCEPTION: THIS REQUIREMENT SHALL NOT APPLY TO SLOPING PORTIONS OF HANDRAILS SERVING STAIRS AND RAMPS. 1003.3.3 HORIZONTAL PROJECTIONS. ELEMENTS CANNOT PROJLCT OVER A WALKING SURFACE MORE THAN 4 INCHES (102 MM) WHEN THEY ARE LOCATED BETWEEN 27 AND 80 INCHES (686 AND 2032 MM) ABOVE THE FLOOR. HANDRAILS CAN PROJECT UP TO 41h INCHES (114 MM) FROM THE WALL. 1003.4 FLOOR SURFACE, WALKING SURFACES SHALL BE SLIP RESISTANT UNDER FORESEFABLE CONDITIONS. THE WALKING SURFACE OF EACH ELEMENT IN THE MEANS OF EGRESS SHALL BE UNIFORMLY SLIP RESISTANT ALONG THE NATURAL PATH OF TRAVEL. 1006.1 .2 ILLUMINATION OF MEANS OF EGRESS SHALL BE CONTINUOUS DURING THE TIME THAT THE CONDITIONS OF OCCUPANCY REQUIRE THAT THE MEANS OF EGRESS BE AVAILABLE FOR USE. ARTIFICIAL LIGHTING SHALL BE EMPLOYED AT SUCH PLACES AND FOR SUCH PERIODS OF TIME AS REQUIRED TO MAINTAIN THE ILLUMINATION TO THE MINIMUM CRITERIA VALUES HEREIN SPECIFIED. 1006.1 .3 THE FLOORS AND OTHER WALKING SURFACES WITHIN AN EXIT AND WITHIN THE PORTIONS OF THE EXIT ACCESS AND EXIT DISCHARGE DESIGNATED IN SECTION SHALL BE ILLUMINATED TO VALUES OF AT LEAST 1 FOOTCANDLE (10 LUX) MEASURED AT THE FLOOR. DURING CONDITIONS OF STAIR USE, THE MINIMUM ILLUMINATION FOR NEW STAIRS SHALL BE AT LEAST 108 LUX (10 FOOT- CANDLE), MEASURED AT THE WALKING SURFACE. GENERAL NOTES 1. THE CONTRACTOR IS TO VISIT THE SITE AND VERIFY ALL EXISTING BUILDING AND SITE CONDITIONS. SHOULD ANY DISCREPANCIES BE ENCOUNTERED, THE ARCHITECT /ENGINEER SHOULD BE NOTIFIED IN WRITING 7 DAYS PRIOR TO SUBMITTING HIS BID. 2. THE CONTRACTOR IS TO ACQUIRE ALL REQUIRED PERMITS FOR THE DEMOLITION, CONSTRUCTION AND OCCUPANCY OF THE PROJECT. 3. ALL WORK DONE UNDER THE SUPERVISION OF THE CONTRACTOR SHALL BE IN A NEAT AND WORKMAN -LIKE MANNER AND IN ACCORDANCE WITH ALL GOVERNING AGENCIES, RULES AND REGULATIONS HAVING JURISDICTION. 4. THE CONTRACTOR IS TO PROVIDE ALL THE SUPPLEMENTARY MATERIALS REQUIRED TO PROPERLY INSTALL, SUPPORT, BRACE AND SHORE ALL BUILDING COMPONENTS WITHIN THE SCOPE OF THE PROJECT. 5. THE CONTRACTOR COORDINATE AND SCHEDULE THE WORK OF ALL TRADES TO INSURE THE WORK IS COMPLETED IN A TIMELY MANNER, COMPLYING WITH THE OWNER /CONTRACTOR AGREEMENT, 6. THE CONTRACTOR SHALL PROVIDE AN ON SITE DUMPSTER IN A LOCATION APPROVED BY THE OWNER FOR THE DISPOSAL OF REMOVED MATERIAL. THE DUMPSTER SHALL BE EMPTIED AT APPROPRIATE INTERVALS TO PREVENT OVERFLOW AND UNSIGHTLY CONDITIONS, 7. GENERAL CONTRACTOR SHALL SUBMIT A SCHEDULE FOR DEMOLITION AND CONSTRUCTION PROCEDURES AND OPERATIONAL SEQUENCE FOR REVIEW AND ACCEPTANCE BY THE ARCHITECT /ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT /ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE ENCOUNTERED BETWEEN THE DRAWINGS AND THE FIELD CONDITIONS, ANY DISCREPANCIEL SHALL BE RESOLVED BY ARCHITECT /ENGINEER PRIOR T PROCEEDING WITH THE WORK. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF HIS WORK, INCLUDING, BUT NO LIMITED TO VANDALISM, THEFT, ETC. 10. THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH RED -LINED AS -BUILT DRAWINGS FOR ANY AND ALL FIELD CHANGES AND /OR ADDITIONS TO THE WORK INCLUDED IN THE DRAWINGS. 11. THE CONTRACTOR SHALL PROVIDE AN ITLMIZED COST BREAKDOWN OF ALL ITEMS AND PHASES OF CONSTRUCTION. 12. THE ARCHITECT IS NOT RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES, PROCEDURES OR FOR PRECAUTIONS AND PROGRAMS RELATED TO THE PROJECT'S CONSTRUCTION. 13, ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED, ALL HEADERS ARE DOUBLE MEMBERS UNLESS OTHERWISE NOTED. 14. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR ES EXPECTED TO FURNISH AND INSTALL ALL ITEMS TO COMPLETE ALL BUILDING SYSTEMS AND PROVIDE ALL NECESSARY APPURTENENCES FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 15. CONTRACTOR SHALL SUBMIT PRODUCT CONTROL APPROVAL DATA FOR ALL PRODUCTS AND MATERIALS THAT FALL UNDER THE JURISDICTION OF THE METROPOLITAN DADE COUNTY BUILDING AND ZONING PRODUCT CONTROL DEPARTMENT. 16. ALL WORK TO BE TRUE TO LINE, PLUM AND SQUARE AND ADEQUATELY SUPPORTED. FILL ALL VOIDS BETWEEN COMPONENTS, ALL ITEMS THAT DO NOT MEET THE ARCHITECTS SATISFACTION AS TO GOOD TRADE PRACTICES AND QUALITY WORKMANSHIP WILL BE REPLACED AT THE CONTRACTORS EXPENSE. 17. ALL DESIGN LOADS ARE TO BE AT MINIMUM PER S.FB.C. AND AS OTHERWISE INDICATED IN THE CONTRACT DOCUMENTS. 18, CONTRACTOR TO MAINTAIN SITE SAFE AND CLEAR OF DEBRIS. ALL CONSTRUCTION DEBRIS IS TO BE REMOVED FROM THE WORK AREAS DAILY AND FROM THE SITE AT PROPER INTERVALS. 19. GENERAL CONTRACTOR AND ALL SUB - CONTRACTORS TO GUARANTEE THEIR WORK FOR A MINIMUM PERIOD OF ONE YEAR IN WRITING. 20. GENERAL CONTRACTOR SHOULD SUBMIT TO ARCHITECT (6) SET SIGN & SEAL TRUSS SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 21. GENERAL CONTRACTOR SHOULD SUBMIT TO ARCHITECT SHOP DRAWINGS OF METAL CONNECTIONS, WINDOWS, DOORS, ROOF SYSTEMS AND ALL OTHER APPLICABLE MATERIALS TO BE INCORPORATE INTO CONSTRUCTION, GENERAL NOTES: 1. ALL WOOD TO WOOD CONNECTIONS SHALL BE CONNECTED WITH GALV. METAL STRAP, MIN. 1 /E" x 1" WIDE STRAPPING. 2. ALL PLUMBING AND ELECTRICAL SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2007 CHAPTER 29 AND 27. 3. ALL CLOSET LIGHTS SHALL MEFT NEC. 410.8 4. SMOKE DETECTORS SHALL BE HARDWIRED TO KITCHEN OR BATH CIRCUITS, DO NOT USE SWITCHED OR GFI CIRCUITS. WITH BATTERY BACKUPS. NOTES: 1. A "SUPRA" KEY BOX WILL BE INSTALLED NEAR THE MAIN ENTRANCE AT A HEIGHT OF APROX. 5' 2. STORAGE ROOM TO COMPLY W/ SECTION 8.4 (FBC) 3. ALL SYSTEMS AND EQUIPMENT TO BE MANUFACTURED AND INSTALLED IN ACCORDANCE WITH NFPA, FBC 2007, FIRE PREVENTION BUREAU AND HEALTH DEPARTMENT STANDARDS, 4. ALL INTERIOR FINISH SHALL CBE IN ACCORDANCE WITH SECTION 10.2. INTERIOR WALL AND CEILING FINISH COMPLYING WITH 10.2.3 SHALL BE CLASS 'A' OR CLASS 'B'. - WALLS GWB . - CEILING ACOUSTICAL. 5. ALL PLUMBING AND ELECTRICAL SHALL COMPLY WITH THE F.B.C. (MECH), (ELECT), (PLUMB). FLORIDA BUILDING CODE 2007 CHAPTER 11- BUILDING CODE NOTES: 11-4.2.4 CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS. 11-4.2.4.1 SIZE AND APPROACH. THE MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED TO ACCOMMODATE A SINGLE, STATIONARY WHEELCHAIR AND OCCUPANT IS 30 INCHES BY 48 INCHES (760 MM BY 1220 MM) [SEE FIGURE (A)]. THE MINIMUM CLEAR FLOOR OR GROUND SPACE FOR WHLELCHAIRS MAY BE POSITIONED FOR FORWARD OR PARALLEL APPROACH TO AN OBJECT [SEE FIGURE (B) AND FIGURE (C)]. CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE PART OF THE KNEE SPACE REQUIRED UNDER SOME OBJECTS. 11-4.2.4.2 RELATIONSHIP OF MANEUVERING CLEARANCE TO WHEELCHAIR SPACES. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE FOR A WHEELCHAIR SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER WHEELCHAIR CLEAR FLOOR SPACE. IF A CLEAR FLOOR SPACE IS LOCATED IN AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF THREE SIDES, ADDITIONAL MANEUVERING CLEARANCES SHALL BE PROVIDED AS SHOWN IN FIGURE 4(D) AND FIGURE 4(E). 11 - 4.2.4.3 SURFACES FOR WHEELCHAIR SPACES. CLEAR FLOOR OR GROUND SPACES FOR WHEELCHAIRS SHALL COMPLY WITH SECTION 11-4.5. 11-4.2.5 FORWARD REACH. IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD APPROACH TO AN OBJECT, THE MAXIMUM HIGH FORWARD REACH ALLOWED SHALL BE 48 INCHES (1220 MM). THE MINIMUM LOW FORWARD REACH IS 15 INCHES (380 MM) [SEE FIGURE 5(A)]. IF THE HIGH FORWARD REACH IS OVER AN OBSTRUCTION, REACH AND CLEARANCES SHALL BE AS SHOWN IN FIGURE 5(B). 11-4.2.6 SIDE REACH_ IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACH ALLOWED SHALL BE 54 INCHES (1370 MM) AND THE LOW SIDE REACH SHALL BE NO LESS THAN 9 INCHES (230 MM) ABOVE THE FLOOR [SEE FIGURE 6(A) AND FIGURE 6(B)], IF THE SIDE REACH IS OVER AN OBSTRUCTION, THE REACH AND CLEARANCES SHALL BE AS SHOWN IN FIGURE 6(C). 11-4.5 GROUND AND FLOOR SURFACES. 11-4.5.1 GENERAL. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES INCLUDING FLOORS, WALKS, RAMPS, STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM, SLIPRESISTANT, AND SHALL COMPLY WITH SECTION 11-4.5. 11-4.5.2 CHANGES IN LEVEL. CHANGES IN LEVEL UP TO 1/4 INCHES (6 MM) MAY BE VERTICAL AND WITHOUT EDGE TREATMENT [SEE FIGURE 7(C)]. CHANGES IN LEVEL BETWEEN 1/4 INCH AND Y2 INCH (6 MM AND 13 MM) SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 [SEE FIGURE 7(D)]. CHANGES IN LEVEL GREATER THAN M INCH (13 MM) SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH SECTION 11-4.7 OR 11-4.8. 11-4.5.4 GRATINGS. IF GRATINGS ARE LOCATED IN WALKING SURFACES, THEN THEY SHALL HAVE SPACES NO GREATER THAN 16 INCH (13 MM) WIDE IN ONE DIRECTION [SEE FIGURE 8(G)], IF GRATINGS HAVE ELONGATED OPENINGS, THEN THEY SHALL BE PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL [SEE FIGURE 8(H)] 11-4.27 CONTROLS AND OPERATING MECHANISMS, 11-4.27.1 GENERAL. CONTROLS AND OPERATING MECHANISMS REQUIRED TO BE ACCESSIBLE BY SECTION 11-4.1 SHALL COMPLY WITH SECTION 11-4.27. 11-4.27.2 CLEAR FLOOR SPACE. CLEAR FLOOR SPACE COMPLYING WITH SECTION 11-4.2.4 THAT ALLOWS A FORWARD OR A PARALLEL APPROACH BY A. PERSON USING A WHEELCHAIR SHALL BE PROVIDED AT CONTROLS, DISPENSFRS, RECEPTACLES AND OTHER OPERABLE EQUIPMENT. 11-4.27.3 HEIGHT. THE HIGHEST OPERABLE PART OF CONTROLS, DISPENSERS, RECEPTACLES, AND OTHFR OPERABLE EQUIPMENT SHALL BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES SPECIFIED IN SECTIONS 11-4.2.5 AND 11 -4.2.6 ELECTRICAL AND COMMUNICATIONS SYSTEM RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS THAN 15 INCHES (380 MM) ABOVE THE FLOOR. EXCEPTION: THESE REQUIREMENTS DO NOT APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE ELECTRICAL AND COMMUNICATIONS SYSTEMS RECEPTACLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS. 11 - 4.27.4 OPERATION. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERA13LL WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINSHING, OR TWISTING OF THE WRIST, THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 _BF (22.2 N). 11 -4.28 ALARMS. 11-4.28.1 GENERAL. ALARM SYSTEMS REQUIRED TO BE ACCESSIBLE BY SECTION 11-4.1 SHALL COMPLY WITH SECTION 11-4,28. AT A MINIMUM, VISUAL SIGNAL APPLIANCES SHALL BE PROVIDED IN BUILDINGS AND FACILITIES IN EACH OF THE FOLLOWING AREAS: RESTROOMS AND ANY OTHER GENERAL USAGE AREAS (E.G., MEETING ROOMS), HALLWAYS, LOBBIES, AND ANY OTHER AREA FOR COMMON USE. 11-4.28.2 AUDIBLE ALARMS. IF PROVIDED, AUDIBLE EMERGENCY ALARMS SHALL PRODUCE A SOUND THAT EXCEEDS THE PREVAILING EQUIVALENT SOUND LEVEL IN THE ROOM OR SPACE BY AT LEAST 15 DBA OR EXCEEDS ANY MAXIMUM SOUND LEVEL WITH A DURATION OF 60 SECONDS BY 5 DBA, WHICHEVLR IS LOUDER. SOUND LEVELS FOR ALARM SIGNALS SHALL NOT EXCEED 120 DBA. 11-4.25.3 VISUAL ALARMS. VISUAL ALARM SIGNAL APPLIANCES SHALL BE INTEGRATED INTO THE BUILDING OR FACILITY ALARM SYSTEM. IF SINGLE STATION AUDIBLE ALARMS ARE PROVIDED THEN SINGLE STATION VISUAL ALARM SIGNALS SHALL BE PROVIDED. VISUAL ALARM SIGNALS SHALL HAVE THE FOLLOWING MINIMUM PHOTOMETRIC AND LOCATION FEATURES: (1) THE LAMP SHALL BE A XENON STROBE TYPE OR EQUIVALENT. (2) THE COLOR SHALL BE CLEAR OR NOMINAL WHITE (I,E., UNFILTERED OR CLEAR FILTERED WHITE LIGHT). (3) THE MAXIMUM PULSE DURATION SHALL BE TWO- TENTHS OF ONE SECOND (0.2 SEC) WITH A MAXIMUM DUTY CYCLE OF 40 PERCENT. THE PULSE DURATION IS DEFINED AS THE TIME INTERVAL BETWEEN INITIAL AND FINAL POINTS OF 10 PERCENT OF MAXIMUM SIGNAL. (4) THE INTENSITY SHALL BE A MINIMUM OF 75 CANDELA. (5) THE FLASH RATE SHALL BE A MINIMUM OF 1 HZ AND A MAXIMUM OF 3 HZ. (6) - THE APPLIANCE SHALL BE PLACED 80 INCHES (2030 MM) ABOVE THE HIGHEST FLOOR LEVEL WITHIN THE SPACE OR 6 INCHES (152 MM) BELOW THE CEILING, WHICHEVER IS LOWER. (7) IN GENERAL, NO PLACE IN ANY ROOM OR SPACE REQUIRED TO HAVE A VISUAL SIGNAL APPLIANCE SHALL BE MORE THAN 50 FEET (15 M) FROM THE SIGNAL (IN THE HORIZONTAL PLANE). IN LARGE ROOMS AND SPACES EXCEEDING 100 FEET (30 M) ACROSS, WITHOUT OBSTRUCTIONS 6 FEET (2 M) ABOVE THE FINISH FLOOR, SUCH AS AUDITORIUMS, DEVICES MAY BE PLACED AROUND THE PERIMETER, SPACED A MAXIMUM 100 FEET (30 M) APART, IN LIEU OF SUSPENDING APPLIANCES FROM THE CEILING. (8) NO PLACE IN COMMON CORRIDORS OR HALLWAYS IN WHICH VISUAL ALARM SIGNALING APPLIANCES ARE REQUIRED SHALL BE MORE THAN 50 FEET (15 M) FROM THE SIGNAL. FIXTURES AND WALL CABINETS NOTES: FIXTURES AND WALL CABINETS SHALL BE NOT LESS THAN 2 "X4" (FIRE RETARDANT) WHERE SPACED NOT MORE THAN 16" O.C.; OR NOT LESS THAN 2 "X6" (FIRE RETARDANT), WHERE SPACED NOT MORE THAN 24" O.C. 2.- A MIN. 2 "X4" (FIRE RETARDANT) HORIZONTAL WOOD MEMBER, SECURED FASTENED TO NOT LESS THAN 2 SUCH STUDS, SHALL BE INSTALLED FOR THE ATTACHMENT OF EACH WALL HUNG PLUMBING FIXTURE AND WALL CABINET. I. Y U • Y • • • i • + Y • + V • `•" 'PROJECT N °: 10-233 G • • • • r • V V Y .Y.. • • Y � • •rr•y w 0 cl < Co 0 Co U u w °w= O aa~ cn < <LL •ii 1 o C N Tow z or - G,'II'I o�z N u V, in CO v < U Z a,`n`fl <0 rns`7ac S <� C�7 c 1 o O dl O W <NW (sI UE"w Uzi 5a x w Ow 0= m� a0 OF wr �n as Vl w o< a <Z w0 1.4 w a 10 W�: CE <z to w ` C� U v)z� W -0 < <o Uoa WIw�y V)Jof I� � < w < ► -+ m to -� o 0 «° Qom' I� zio O d��zz '. � ?w ONU III I UW5 aof m <juwi 2Z)lp U 9 oW� .� r ~z x=w aWOi 0 U I- Z LL f �I� Q Q O U C� C f Q I Zi HI 0 O U) 0 W rri III �`I UDI CONTRACT DATE: XX.XX.XX (-p BUILDING TYPE: K38 � PLAN VERSION: Jan 08 � SITE NUMBER: XXX -XXX J I TORE NUMBER: K478006 Q 0 KFC :E W 5826 SW 40 STREET SOUTH MIAMI, FLORIDA lu 0I U U IL K38 REMODEL C i I CODE RESEARCH Scale: N1'S I w 4 A o t LOT DATE: 08 -02 -10 N Y. i • • Y • • i V � PROJECT INFORMATION • • i Y • • •i • • Y • • Y Y • Y Y Y Y Y Y • ► V Y • • PROPOSED KFC RENOVATION. ,YYG •„ 5826 BIRD ROAD, MIAMI, FLORIDA. • r FLORIDA BUILDING CODE RESEARCH FLORIDA BUILDING CODE (2007): EXISTING BUILDING. THE PROPOSED WORK TO BE DONE TO THE EXISTING BUILDING HAS BEEN CLASSIFIED AS: ALTERATION -LEVEL 2 (SEE SECTION 404 BELOW) SECTION 404 ALTERATION -LEVEL 2 404.1 SCOPE. LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. 404.2 APPLICATION. LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF FOR LEVEL 1 ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 7. SCOPE OF WORK: 1. OCCUPANCY: PER SECTION 303 -ASSEMBLY GROUP A -2 (RESTAURANT), TO REMAIN. 2. AUTOMATIC SPRINKLER SYSTEM: EXISTING BUILDING TO REMAIN WITHOUT AUTOMATIC SPRINKLER SYSTEM. 3. DINING ROOM: TO BE REMODELED, REFER TO PROPOSED FLOOR PLAN FOR FURNITURE LAYOUT AND FINISH MATERIALS (BY OTHERS) 4. BATHROOMS: TO BE RECONFIGURED, REFER TO PROPOSED FLOOR PLAN FOR NEW LAYOUT. 5. KITCHEN /SERVING AREA: TO REMODELED, REFER TO PROPOSED FLOOR PLAN AND EQUIPMENT SCHEDULE. 6. EXTERIOR ELEVATIONS: TO BE REMODEL, REFER TO PROPOSED EXTERIOR ELEVATIONS. 7. EXISTING PARKING AREA AND DRIVEWAY: TO BE RESURFACED, REFER TO SITE PLAN. FBC 2007 - SECTION 426 PUBLIC FOOD SERVICE ESTABLISHMENTS 426.1 SCOPE, PUBLIC FOOD SERVICE ESTABLISHMENTS OR FOOD ESTABLISHMENTS SHALL COMPLY WITH DESIGN AND CONSTRUCTION STANDARDS AS DESCRIBED IN THE FOOD CODE, CHAPTER 509 PART I OR CHAPTER 500, FLORIDA STATUTES, AS APPLICABLE. NOTE: OTHER ADMINISTRATIVE AND PROGRAMMATIC PROVISIONS MAY APPLY. SEE DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION (DBPR) RULE 61C-4, FLORIDA ADMINISTRATIVE CODE CHAPTER 500 AND CHAPTER 509, FLORIDA STATUTES. 426.3 GENERAL SANITATION AND SAFETY REQUIREMENTS. THE FOLLOWING GENERAL REQUIREMENTS AND STANDARDS SHALL BE MET BY ALL FOOD SERVICE ESTABLISHMENTS: 426.3.1 WATER, PLUMBING, AND WASTE. EXCEPT AS SPECIFICALLY PROVIDED IN THIS SECTION, STANDARDS FOR WATER, PLUMBING AND WASTE SHALL BE GOVERNED BY , FOOD CODE, HEREIN ADOPTED BY REFERENCE. 426.3.1.1 GREASE INTERCEPTORS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. 426.3.2 PUBLIC BATHROOMS. 426.3.2.1 FOOD SERVICE ESTABLISHMENT SHALL BE PROVIDED WITH ADEQUATE AND CONVENIENTLY LOCATED BATHROOM FACILITIES FOR ITS EMPLOYEES AND GUESTS IN ACCORDANCE WITH PROVISIONS OF THE FLORIDA BUILDING CODE, PLUMBING. PUBLIC ACCESS TO TOILET FACILITIES SHALL NOT BE PERMITTED THROUGH FOOD PREPARATION, STORAGE, OR WARE WASHING AREAS. BATHROOM FIXTURES SHALL BE OF READILY CLEANABLE SANITARY DESIGN. 426.3.2.2 PUBLIC BATHROOMS SHALL BE COMPLETELY ENCLOSED AND SHALL HAVE TIGHT - FITTING, SELF CLOSING DOORS OR, IN PUBLIC LODGING ESTABLISHMENTS OR BATHROOMS LOCATED OUTSIDE A PUBLIC FOOD SERVICE, HAVE ENTRANCES AND EXITS CONSTRUCTED IN SUCH A MANNFR AS TO ENSURE PRIVACY OF OCCUPANTS. 426.3.3 VERMIN CONTROL. EFFECTIVE CONTROL MEASURES SHALL BE TAKEN TO PROTECT AGAINST THE ENTRANCE INTO THE ESTABLISHMENT, AND THE BREEDING OR PRESENCE ON THE PREMISES OF RODENTS, FLIES, ROACHES AND OTHER VERMIN. ALL BUILDINGS SHALL BE EFFECTIVELY RODENTPROOFED. ALL WINDOWS USED FOR VENTILATION MUST BE SCREENED, EXCEPT WHEN EFFECTIVE MEANS OF VERMIN CONTROL ARE USED. SCREENING MATERIAL SHALL NOT BE LESS THAN 16 MESH TO THE INCH OR EQUIVALENT, TIGHTFITTING AND FREE OF BREAKS. 426.3.4 FIRE SAFETY. ALL FIRE SAFETY, PROTECTION AND PREVENTION EQUIPMENT MUST BE INSTALLED, APPROVED, MAINTAINED AND USED IN ACCORDANCE WITH CHAPTER 509, FLORIDA STATUTES, CHAPTER 69A -55, UNIFORM FIRE SAFETY STANDARDS FOR PUBLIC FOOD SERVICE ESTABLISHMENTS, FAC, AND THE UNIFORM FIRE SAFETY STANDARDS AS ADOPTED BY THE STATE FIRE MARSHAL 426.3.5 ELECTRICAL WIRING. TO PREVENT FIRE OR INJURY, DEFECTIVE ELECTRICAL WIRING SHALL BE REPLACED AND WIRING SHALL BE KEPT IN GOOD REPAIR. ONLY A WALL SWITCH OR APPROVED PULL CORD SHALL BE PERMITTED IN BATHROOMS. ELECTRICAL WIRING SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF FLORIDA BUILDING CODE, BUILDING,. 426.3.6 GAS APPLIANCES, 426.3.6.1 ALL APPLIANCES, INCLUDING WATER HEATERS USING GAS, SHALL BE PROPERLY VENTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, FUEL GAS. ALL APPLIANCES SHALL HAVE A NATIONALLY RECOGNIZED TESTING LABORATORY SEAL SUCH AS AGA OR UL SEAL. 426.3.6,2 HEATING APPLIANCES SHALL BE PROPERLY SIZED IN BTU INPUT FOR ROOM AIR SPACE. PROPER SIZING OF HEATING APPLIANCES SHALL BE DETERMINED IN ACCORDANCE WITH THE PROVISIONS OF THE FLORIDA BUILDING CODE, FUEL GAS, CITY OF SOUTH N111AI' 'v1t BUILDING DEPT. STRUCTURAL ECTIONI ',;'PROVED BY:. �;, 1 , • � • Yu Yu Y i• • Y r • U • • • • W • • Y • • i V � PROJECT INFORMATION • • i Y • • •i • • Y • • Y Y • Y Y Y Y Y Y • ► V Y • • PROPOSED KFC RENOVATION. ,YYG •„ 5826 BIRD ROAD, MIAMI, FLORIDA. • r FLORIDA BUILDING CODE RESEARCH FLORIDA BUILDING CODE (2007): EXISTING BUILDING. THE PROPOSED WORK TO BE DONE TO THE EXISTING BUILDING HAS BEEN CLASSIFIED AS: ALTERATION -LEVEL 2 (SEE SECTION 404 BELOW) SECTION 404 ALTERATION -LEVEL 2 404.1 SCOPE. LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. 404.2 APPLICATION. LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF FOR LEVEL 1 ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 7. SCOPE OF WORK: 1. OCCUPANCY: PER SECTION 303 -ASSEMBLY GROUP A -2 (RESTAURANT), TO REMAIN. 2. AUTOMATIC SPRINKLER SYSTEM: EXISTING BUILDING TO REMAIN WITHOUT AUTOMATIC SPRINKLER SYSTEM. 3. DINING ROOM: TO BE REMODELED, REFER TO PROPOSED FLOOR PLAN FOR FURNITURE LAYOUT AND FINISH MATERIALS (BY OTHERS) 4. BATHROOMS: TO BE RECONFIGURED, REFER TO PROPOSED FLOOR PLAN FOR NEW LAYOUT. 5. KITCHEN /SERVING AREA: TO REMODELED, REFER TO PROPOSED FLOOR PLAN AND EQUIPMENT SCHEDULE. 6. EXTERIOR ELEVATIONS: TO BE REMODEL, REFER TO PROPOSED EXTERIOR ELEVATIONS. 7. EXISTING PARKING AREA AND DRIVEWAY: TO BE RESURFACED, REFER TO SITE PLAN. FBC 2007 - SECTION 426 PUBLIC FOOD SERVICE ESTABLISHMENTS 426.1 SCOPE, PUBLIC FOOD SERVICE ESTABLISHMENTS OR FOOD ESTABLISHMENTS SHALL COMPLY WITH DESIGN AND CONSTRUCTION STANDARDS AS DESCRIBED IN THE FOOD CODE, CHAPTER 509 PART I OR CHAPTER 500, FLORIDA STATUTES, AS APPLICABLE. NOTE: OTHER ADMINISTRATIVE AND PROGRAMMATIC PROVISIONS MAY APPLY. SEE DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION (DBPR) RULE 61C-4, FLORIDA ADMINISTRATIVE CODE CHAPTER 500 AND CHAPTER 509, FLORIDA STATUTES. 426.3 GENERAL SANITATION AND SAFETY REQUIREMENTS. THE FOLLOWING GENERAL REQUIREMENTS AND STANDARDS SHALL BE MET BY ALL FOOD SERVICE ESTABLISHMENTS: 426.3.1 WATER, PLUMBING, AND WASTE. EXCEPT AS SPECIFICALLY PROVIDED IN THIS SECTION, STANDARDS FOR WATER, PLUMBING AND WASTE SHALL BE GOVERNED BY , FOOD CODE, HEREIN ADOPTED BY REFERENCE. 426.3.1.1 GREASE INTERCEPTORS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. 426.3.2 PUBLIC BATHROOMS. 426.3.2.1 FOOD SERVICE ESTABLISHMENT SHALL BE PROVIDED WITH ADEQUATE AND CONVENIENTLY LOCATED BATHROOM FACILITIES FOR ITS EMPLOYEES AND GUESTS IN ACCORDANCE WITH PROVISIONS OF THE FLORIDA BUILDING CODE, PLUMBING. PUBLIC ACCESS TO TOILET FACILITIES SHALL NOT BE PERMITTED THROUGH FOOD PREPARATION, STORAGE, OR WARE WASHING AREAS. BATHROOM FIXTURES SHALL BE OF READILY CLEANABLE SANITARY DESIGN. 426.3.2.2 PUBLIC BATHROOMS SHALL BE COMPLETELY ENCLOSED AND SHALL HAVE TIGHT - FITTING, SELF CLOSING DOORS OR, IN PUBLIC LODGING ESTABLISHMENTS OR BATHROOMS LOCATED OUTSIDE A PUBLIC FOOD SERVICE, HAVE ENTRANCES AND EXITS CONSTRUCTED IN SUCH A MANNFR AS TO ENSURE PRIVACY OF OCCUPANTS. 426.3.3 VERMIN CONTROL. EFFECTIVE CONTROL MEASURES SHALL BE TAKEN TO PROTECT AGAINST THE ENTRANCE INTO THE ESTABLISHMENT, AND THE BREEDING OR PRESENCE ON THE PREMISES OF RODENTS, FLIES, ROACHES AND OTHER VERMIN. ALL BUILDINGS SHALL BE EFFECTIVELY RODENTPROOFED. ALL WINDOWS USED FOR VENTILATION MUST BE SCREENED, EXCEPT WHEN EFFECTIVE MEANS OF VERMIN CONTROL ARE USED. SCREENING MATERIAL SHALL NOT BE LESS THAN 16 MESH TO THE INCH OR EQUIVALENT, TIGHTFITTING AND FREE OF BREAKS. 426.3.4 FIRE SAFETY. ALL FIRE SAFETY, PROTECTION AND PREVENTION EQUIPMENT MUST BE INSTALLED, APPROVED, MAINTAINED AND USED IN ACCORDANCE WITH CHAPTER 509, FLORIDA STATUTES, CHAPTER 69A -55, UNIFORM FIRE SAFETY STANDARDS FOR PUBLIC FOOD SERVICE ESTABLISHMENTS, FAC, AND THE UNIFORM FIRE SAFETY STANDARDS AS ADOPTED BY THE STATE FIRE MARSHAL 426.3.5 ELECTRICAL WIRING. TO PREVENT FIRE OR INJURY, DEFECTIVE ELECTRICAL WIRING SHALL BE REPLACED AND WIRING SHALL BE KEPT IN GOOD REPAIR. ONLY A WALL SWITCH OR APPROVED PULL CORD SHALL BE PERMITTED IN BATHROOMS. ELECTRICAL WIRING SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF FLORIDA BUILDING CODE, BUILDING,. 426.3.6 GAS APPLIANCES, 426.3.6.1 ALL APPLIANCES, INCLUDING WATER HEATERS USING GAS, SHALL BE PROPERLY VENTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, FUEL GAS. ALL APPLIANCES SHALL HAVE A NATIONALLY RECOGNIZED TESTING LABORATORY SEAL SUCH AS AGA OR UL SEAL. 426.3.6,2 HEATING APPLIANCES SHALL BE PROPERLY SIZED IN BTU INPUT FOR ROOM AIR SPACE. PROPER SIZING OF HEATING APPLIANCES SHALL BE DETERMINED IN ACCORDANCE WITH THE PROVISIONS OF THE FLORIDA BUILDING CODE, FUEL GAS, CITY OF SOUTH N111AI' 'v1t BUILDING DEPT. STRUCTURAL ECTIONI ',;'PROVED BY:. �;, 1 ,