09-1054-006O O 1 1 O O 1 1 0 O O 0 1 1 0 O O 0 1 1 0 O O 0 1 1 O O
PETER RO,�M � J
C -2 C,�
1 ii ii ii rte.
� C -I
- - - - - - RE"IOVE AND
- - - -- RELCCATE.
ELECT. F4NEL
EMERGENCY LIG14T c I
ExiT &CN - - - - - -J c -�
12X4 F=L, Uri-T
i i �-
L...W__--- - - - - -J
C -1
F4 c-1
C -1 C -1
J � J
EXISTING ELECTRICAL PLAN
ry
0
- - -- - ---- T ----------- I T - 1
C 2 o r-2 o C
JAL LEGEND
o \
0
0
0
------- DENOTE5 TO BE REMOVEID
DENOTE5 NEW P,,R T ITION5
DENOTES EXISTING TO REMAIN
DENOTE5 JUNCTION 80X, LIGHT AND OUTLET
TO BE REMOVED AND CIRCUIT TO REMAIN
0
FMERC5ENCY LICzI-
EXIT 51�N CCr150
m
C-L
�r J
I I
i
i
1
� 1
i i
L- - - - - -J
II N%,/ I vV4.4-/ } .�\.e" I \I ��I «.--, ,�_ I ,mow __�_,,_ „-, -- .. —, ,„
1/411 = 11.011 r3ENER ,4L. LIGHTING CIRCUIT
GDIERAL ELECol"RICAL NOTES
1, ALL WORK 5HALL BE DONE IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE, FLORIDA BUILDING CODE AND OTHER
APPLICABLE CODE5 AND 5TANDARD5.
2, THE CONTRACTOR 15 RE5PON5IBLE FOR EVALUATING FIELD
CONDI T IONS B'r' V151TING THE SITE PRIOR TO
COMMENCING /BIDDING WORK,
4, ALL MATERIAL REMOVED 5HALL BE 1)15PO5ED OF A5 DIRECTED Bar
OWNER,
5, WIRE 51ZE SHALL BE 012 THHN /THWN UNLE55 OTPERW15E NOTED
ON PLANS, CONDUCTOR5 '(o AND LARGER SHALL BE T HW,
(o. ALL CONDUCTOR5 5HALL BE COPPER,
1, ALL CONDUCTOR5 5HALL BE RUN IN CONDUIT (METALLIC T''PE).
IF PVC SCHEDULE 40 15 USED FOR UNDERGROUND FEEDER5 ONLY',
AN EQUIPMENT GROUND CONDUCTOR 51ZED IN ACCORDANCE WITH
N.E.C. 250 -122 MUST BE INSTALLED AND CONDUIT 51ZE
INCREA5ED AS REQUIRED,
S, ALL MATERIAL5 5HALL BE U.L. APPROVED.
�,A,L.L BRANCH CIRCUIT5 5HALL BE PROPERLY PHA5E BALANCED,
10.C:ONTRACTOR 5HALL 5EAL ALL FLOOR OPENING5 WITH A FIRE
5EAL 51MILAR TO 1021 FLAME5EAL.
11.41..E EMPTY' CONDUITS TO BE PROVIDED WITH N'-LON PULL 5TRING5,
12,FL15E5 5HALL BE DUAL ELEMENT, TIME DELAY' TYPE UNLE55
OTPERW15E NOTED.
13,CONTRACTOR SHALL COORDINATE ALL H15 WORK WITH OTHER
TRADE5 IN ORDER TO FURNI5H AND INSTALL ALL CONTROL WIRING
AND RACEWAY'51 ALL POWER CONTROL CIRCUIT5 WIRING AND
RACEWA''5 A5 SHOWN ON THE AIR CONDITIONING 1)RAWING5 OR
5PECIFICATION5.IF AIR CONDITIONING DRAWING5 REFER TO
MANUFACTURER15 WIRING DIAGRAM5, THE CONTRACTOR 5H4.LL
VERIFY WITH 5AID MANUFACTURER ALL REQUIREMENT 5 AND
INCLUDE ALL RELATED WORK IN H15 CONTRACT.
15,11'45 DRAWING 15 A GUIDE FOR THE INSTALLATION OF
ELECTRICAL 5ERVICE, THE ELECTRICAL CONTRACTOR 15
RE5PON515LE TO PROVIDE A FUNCTIONING 5'CSTEM.
1 (o,ALL CABLES SHALL BE RUN WITHOUT 6PLICE5 EXCEPT OTHERWISE
INDICATED.
11ALL PULL AND JUNCTION 5OXE5 5HALL BE ACCE55IBLE AT ALL
TIMES,
1a,EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED
IN FIELD,
19,ALL WORK 5HALL BE DONE IN A NEAT AND WORKMANLIKE MANNER,
20,61RANCH CIRCUIT BREAKER5 SHALL BE OF THE BOLT -ON T`�PE,
PLUG -IN CIRCUIT BREAKER5 WILL NOT BE ACCEPTED,
«
r.
. . . . . .....
y
Architect RubenTr vieso
AR 000 8229
2248 SW 57 AV., MIAMI, FL. 33155
786.260.7522 Cell - 786 -388 -0312 PHN
786.388.0366 FAX
E -MAIL: rubentravieso @bellsouth.riot
a
REVISIONS:
1
DATE
REMARK
COMMENTS BY FIRE
;
12 -10 -09
PROJECT:
PROPOSED INTERIOR
LAYOUT FOR:
5825 SUNSET DRIVE
SHEET CONTENT:
EXISTING ELECTRICAL
PROPOSED ELECTRICAL
SEAL:
,r.
f ,
_191
L
ALL IDEAS, DESIGNS, ARRANGEMENTS
AND PLANS INDICATED OR REPRESEN-
TED BY THIS DRAWING ARE OWNED
BY, AND THE PROPERTY OF THIS OF-
FICE AND WERE CREATED, EVOLVED
AND DEVELOPED FOR USE ON, AND
IN CONNECTION WITH THE SPECIFIED
k
PROJECT. NONE OF SUCH IDEAS, DE-
SIGNS, ARRANGEMENTS OR PLANS SHALL
BE USED BY OR DISCLOSED TO ANY
PERSON, FIRM OR CORPORATION FOR
ANY PURPOSE WHATSOEVER WITHOUT
THE EXPRESSLY WRITTEN PERMISSION
OF RUBEN TRAVIESO, ARCHITECT.
DATE:
DRAWN BY:
CHECKED BY:
FILENAME:
r
a
«
r.