14-235-006,� • ! A, AMPS AMPERES AC,A /C ALTERNATING CURRENT, AIR CONDITIONING AFF. ABOVE FINISH FLOOR AFCI ARC FAULT CIRCUIT INTERRUPTER AHU AIR HANDLING UNIT AIC AMPERES INTERRUPTING CURRENT ANSI AMERICAN NATIONAL STANDARDS INSTITUTE ARCH ARCHITECT OR ARCHITECTURAL ATS AUTOMATIC TRANSFER SWITCH BFC BELOW FINISHED CEILING BLDG. BUILDING C CONDUIT CLG. CEILING CU COPPER, CONDENSING UNIT E EXISTING ELECTRICAL EQUIPMENT /DEVICE EF EXHAUST FAN ER EXISTING ELECTRICAL EQUIPMENT /DEVICE TO BE REMOVED. ERL EXISTING ELECTRICAL EQUIPMENT /DEVICE TO BE RELOCATED EWH ELECTRICAL WATER HEATER FBC FLORIDA BUILDING CODE FLA FULL LOAD AMPS, FLORIDA FT FEET G GROUND GFI GROUND FAULT INTERRUPT HP HORSEPOWER HZ. HERTZ (CYCLES) I.G. ISOLATED GROUND INC. INCANDESCENT KW KILOWATTS KWH KILOWATT HOUR LRA LOCKED ROTOR AMPS M MOTOR MCA MINIMUN CIRCUIT AMPAACITY MCB MAIN CIRCUIT BREAKER MLO MAIN LOAD ONLY MOCP MAXIMUN OVER CURRENT PROTECTION N NEW ELECTRICAL EQUIPMENT /DEVICE EQUIPMENT SHOWN WITHOUT ABBREVIATION IS TO BE CONIDERED AS NEW NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOC. NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NCL NON COINCIDENT LOAD NL NIGHT LIGHT NOM. NOMINAL N.T.S. NOT TO SCALE OSHA OCCUPATIONAL SAFETY & HEALTH ACT P POLE P.E. PROFESSIONAL ENGINEER PH. PHASE. P.O.S. POINT OF SALE PVC POLYVINYL CHLORINE R RELOCATED EXISTING EQUIPMENT DEVICE RECEP, REC. RECEPTACLE RLA RUNNING LOAD AMPACITY S/N SOLID NEUTRAL SWGR SWITCHGEAR XTR ELECTRICAL TRANSFORMER TYP. TYPICAL U.L. UNDERWRITERS LABORATORIES V VOLT VA VOLT AMPERES VP VAPOR PROOF W. WIRE, WATT, WIDE WP WATER PROOF RECOMEND CONDUCTOR COLOR CODE ELECTRICAL (PHASE 120/240V 120/208V 277/480V DELTA A BLACK BLACK YELLOW B ORANGE(Hgh Leg) RED ORANGE C BLUE BLUE BROWN NEUTRAL WHITE WHITE GREY GROUND GREEN GREEN GREEN GENERAL: 1. Lighting and power wiring system conductors shall be color coded at all locations where conduit is broken and at each conductor termination. I FUSE 2. Conductors #6 and smaller shall be color coded with colored insulation. 3. Conductors #4 and larger where not available in colors, shall be color coded with colored pressure sensitive tape at all termination and in junction and pull boxes. O 20 ELECTRICAL NOTES 1- ALL WORK SHALL BE PERFORMED TO MEET THE REQUIREMENTS OF THE GOVERNING EDITION OF THE NATIONAL ELECTRICAL CODE (N.E.C. 2008), FBC 2010, LOCAL AND STATE CODES AND ANY OTHER APPLICABLE CODES AND STANDARS. 2- THE ELECTRICAL DESIGN IS BASED UPON THE AVAILABLE INFORMATION AT DESIGN TIME AND THE CONTRACTOR SHALL REVIEW NAMEPLATE DATA AND MANUFACTURER SUPPLIED LITERATURE FOR ALL PIECES OF EQUIPMENT PRIOR TO ROUGH ELECTRICAL WIRING. THE CONTRACTOR SHALL CHECK ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE AND AMP RATING PRIOR TO INSTALLATION. THE CONTRACTOR SHALL CONTACT ENGINEER PRIOR TO ANY FIELD ADJUSTMENT. 3- PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CHECK NAMEPLATE DATA OF ALL EQUIPMENT FOR REQUIRED VOLTAGES, MINIMUM CIRCUIT AMPACITY, AND OVERCURRENT PROTECTION. 4- DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR EXACT LOCATION OF EQUIPMENT. THESE DRAWINGS ARE NOT INTENDED TO SHOW EVERY MINOR DETAIL. HOWEVER, THE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE AND ACCEPTABLE WORKING INSTALLATION PER CODE. 5- ALL MATERIAL SHALL BEAR UL LABEL WHERE APPLICABLE. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT FOR A COMPLETE INSTALLATION. ALL MOUNTING HARDWARE AND WIRING HARDWARE SHALL BE FURNISHED BY THE CONTRACTOR. 6- CIRCUITS SHOWN ON THESE PLANS ARE SYMBOLICALLY SHOWN TO DETERMINE LOAD DATA AND EQUIPMENT SIZES. THE CONTRACTOR SHALL PHYSICALLY PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDITIONS. THE LOADS SHALL BE BALANCED THROUGHOUT. THE CONTRACTOR SHALL ENSURE THAT NEUTRAL WIRES AND EQUIPMENT GROUND WIRES ARE INSTALLED WHERE EVER APPLICABLE. 7- ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ARCHITECT /OWNER TO FIELD VERIFY INSTALLATION FOR OUTLETS, LIGHTING FIXTURES AND ELECTRICAL EQUIPMENT. 8- THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 9- ALL WIRING SHALL BE COPPER (CU) THWN INSULATION. IF ALUMINUM WIRES ARE USED: A) TO PREVENT OVERHEATING AT CONNECTION POINTS USE OXIDE INHIBITING COMPOUND FOR STRIPPED PORTION OF CONDUCTORS INSIDE CONNECTORS. B) A PREVENTIVE MAINTENANCE PLAN IS NECESSARY TO ENSURE A RELIABLE SERVICE INCLUDING VISUAL INSPECTIONS AND TESTS FOR SPLICES AND CONNECTION POINTS (CORROSION AND TIGHTNESS PRINCIPALLY) INSPECTION INTERVALS OF 2 YEARS MAXIMUM ARE STRONGLY RECOMMENDED. 10- ALL CIRCUIT BREAKERS SHALL BE RATED AT MINIMUM OF 10,000 AIC. 11- ALL NEW CONDUCTORS SHALL BE RUN IN CONDUIT (METALLIC TYPE) UNLESS OTHER TYPES CAN BE USED AS PER NEC: A)- PVC SCH. 40 WHEN INSTALLED 12" UNDER SLABS ON GRADE OR WHEN EMBEDDED IN CONCRETE WALLS OR SLABS. B)- MC CABLE CAN BE INSTALLED ACCORDING TO NEC 330.10 AND 330.12. C)- IMC WHEN INSTALLED CONCELED IN MANSONRY WALLS, DRY WALLS OR SUSPENDED CEILINGS, ALSO WHEN INSTALLED IN INTERIORS EXPOSED UP TO 8' AFF. D)- EMT INTERIORS EXPOSED ABOVE 8' AFF AND AT ANY HEIGHT IN ELECTRICAL, MECHANICAL AND TELECOMMUNICATION ROOMS 12- IF PVC CONDUITS ARE USED FOR UNDERGROUND FEEDERS, AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250 - 122 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. 13- TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED REFLECTING ALL CHANGES AND ADDITIONS. 14- ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE MANUFACTURER CEILING, WALL OR POLE INSTALLATION SYSTEM. 15- CONTRACTOR TO VERIFY ADJUSTMENT FACTORS FOR MORE THAN THREE CURRENT - CARRYING CONDUCTORS IN A CCNDUIT ACORDING TO TABLE 310- 15(b)(2)(a) NEC. 16- CONTRACTOR TO PROVIDE SIGNS ON ELECTRICAL PANELS AND DISCONNECTS: "ELECTRICAL EQUIPMENT WITH POTENTIAL ELECTRIC ARC FLASH HAZARDS ". 17 - OUTLETS IN OPPOSITE SIDES ON FIRE RATED WALLS TO BE 24" HORZ. APART (MIN). AND FIRE PROTECTED. 18 - ALL SMOKE OR CARBON MONOXIDE DETECTORS TO BE LOCATED 3' APART MIN. FROM A/C OUTLETS AND INTERCONNECTED FOR SIGNALING PURPOSE. CARBON MONOXIDE DETECTORS TO BE LOCATED 10' MAXIMUM FROM ANY SLEEPING AREA. 19 - ELECTRICAL CONTRACTOR TO VERIFY ILLUMINATION LEVELS AT INTERIOR STAIRS (1 FOOTCANDLE MINIMUM ON TREADS AND LANDINGS) ACCORDING TO THE FLORIDA BUILDING CODE R303.6. NEW PANEL M.L.O. 200A 120/240V 3PH, 4W ELECTRICAL DEMOLITION NOTES 1. WHERE ELECTRIC LIGHTING FIXTURES, SWITCHES, RECEPTACLES, BOXES, CABINETS, DEVICES, ETC. ARE TO BE REMOVED, AND BOXES AND CONDUITS ARE TO REMAIN, ALL CONDUCTORS SHALL BE DE- ENERGIZED, DISCONNECTED AT BOTH ENDS, REVERSED INTO THE BOX, AND THE BOX PLUGGED WITH CEMENT PLASTER OR OTHER APPROVED MATERIAL AND THE WALL, FLOOR, CEILING AND THE LIKE, RESTORED TO MATCH THE SURROUNDING FINISH. 2. WHERE ELECTRICAL FIXTURES, SWITCHES, OUTLETS, RECEPTACLES, BOXES, CABINETS, DEVICES, ETC. ARE TO BE REMOVED, AND THEIR REMOVAL AFFECTS THE OPERATION OF THE EQUIPMENT, FIXTURE, RECEPTACLES, ETC., THAT IS TO REMAIN (INCLUDING ITEMS THAT MAY NOT BE SHOWN IN THE DRAWINGS BUT ARE PRESENTLY EXISTING IN PLACE) THE CONTRACTOR SHALL RE- CIRCUIT THEM (INCLUDING BOXES, CONDUIT, WIRES, ETC.) TO RESTORE THEM TO THE ORIGINAL OPERATING CONDITION. 3. UNUSED OPENINGS IN BOXES, CABINETS, PANELBOARDS, ETC., WHERE CONDUIT IS REMOVED OR PREVIOUSLY EXISTED, SHALL BE PLUGGED OR BLANKED OUT BY APPROVED METHODS, IF THE OPENING IS TO REMAIN. 4. ALL EXPOSED CONDUIT, WIRES, OUTLETS, ETC. NOT TO BE REUSED IN THE NEW REMODELED LAYOUT, SHALL BE REMOVED. 5. EXISTING CONDUIT RUNS, STUBBING UP THRU FLOORS IN AREAS WHERE WALLS ARE TO BE REMOVED, SHALL HAVE THEIR CONDUCTORS DE- ENERGIZED AND REMOVED, CONDUIT CUT -OFF GROUND FLUSH WITH FLOOR AND PLUGGED WITH CEMENT MORTAR OR ANY OTHER APPROVED MATERIAL. THE SAME APPLIES WITH EXISTING CONDUITS THAT ARE STUBBING OUT OF WALLS AND FLOORS. 6. WHERE PRACTICAL, EXISTING CONDUCTORS AND WIRES THAT ARE IN GOOD CONDITION, MAY BE REUSED IN PLACE AND INCORPORATED IN THE NEW REMODELED LAYOUT PROVIDED, IT IS OF PROPER SIZE, TYPE OF CONDUCTOR AND WITH THE APPROVAL OF THE OWNER. 7. ABANDONED CIRCUIT CONDUCTORS IN PANELBOARDS, SHALL BE DISCONNECTED, TAPED AND IDENTIFIED. 8. CONTRACTOR SHALL VISIT THE SITE, PRIOR BIDDING THIS WORK, TO FAMILIARIZE HIMSELF WITH THE STATUS OF THE SPACE. ALL THE REQUIRED DEMOLITION OR MODIFICATIONS (INCLUDING FIXTURES, OUTLETS, BOXES, PANELBOARDS, BREAKERS, TRANSFORMERS, ETC.) ARE TO BE INCLUDED IN THE WORK TO PERFORM IN ORDER TO HAVE A COMPLETE FINISHED INSTALLATION. 9. CONTRACTORS WORK SHALL BE FULLY COORDINATED WITH BUILDING SYSTEMS, AND ANY MODIFICATIONS, OR ADDITIONS THAT WILL ALTER THE BUILDING, SHALL BE MADE IN FULL COMPATIBILITY WITH THE SYSTEMS. WORK ON THE SYSTEMS AND WORK TO BE DONE IN NON- WORKING HOURS, IF REQUESTED, SHALL BE COORDINATED WITH THE BUILDING MANAGER, SPECIAL LIGHTING NOTES 1- REFER TO ARCHITECTURAL CEILING PLAN FOR EXACT LOCATION OF ALL LIGHT FIXTURES. 2- REFER TO ARCHITECTURAL ELEVATIONS FOR FINAL MOUNTING HEIGHTS OF ALL WALL MOUNTED LIGHT FIXTURES. UNLESS NOTED OTHERWISE, ARCHITECTURAL ELEVATIONS SHALL DICTATE MOUNTING HEIGHTS OF ALL FIXTURES. 3 COORDINATE FINAL PLACEMENT OF LIGHT FIXTURES IN ALL MECHANICAL SPACES WITH THE FINAL INSTALLED LOCATIONS OF ALL MECHANICAL DUCTWORK AND PIPING. 4- CONTRACTOR TO VERIFY FLUORESCENT LUMINARIES W /DOUBLE ENDED LAMPS TO BE PROVIDED W /INTERNAL DISCONNECTING MEANS TO DISCONNECT SIMULTANEOUSLY AL CONDUCTORS OF THE BALLAST, INCLUDING THE GROUNDED CONDUCTOR AS PER NEC 410.130 (Gi 5- CONTRACTOR TO VERIFY WITH OWNER ARCHITECT LIGHTING FIXTURE TYPE AND SPECIFICATIONS BEFORE INSTALLATION. 6- WIRE AHEAD OF ANY LOCAL SWITCHING FOR ALL EMERGENCY AND EXIT LIGHTS. 7- ADDITIONAL EXIT AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE FIELD FIRE INSPECTOR AT THE TIME OF THE FIRE FINAL. 8- INTERNALLY ILLUMINATED EXIST SIGN SHALL NOT EXCEED 5 WATTS PER SIDE AS PER FBC EC 505.4 9- RECESSED LUMINARIES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. ALL RECESSED LUMINARIES SHALL BE is -RATED AND LABELED AS MEETING ASTM E 283 (AIR TIGHT) AS PER FBC EC 502.3.8 10- EGRESS ILLUMINATION SHALL BE AT LEAST 1 FOOTCANDLE MEASURED AT THE FLOOR. F.B.C. EC 1006. 11- LIGHTING SYSTEM CONTROLS SHALL BE COMPLY WITH FBC EC 505 as] 0• Ikkkkammaki ZARA I • - - - -- DENOTES EXISTING EQUIPMENT /DEVICE/ OR CONDUIT 3 DENOTES NEW EQUIPMENT /DEVICE/ OR CONDUIT COLD WATER WIRING LEGEND PIPE 3 (D VERIFY MINIMUM OF 4 - #3/0 THWN CU 2" C. (2) 5/8" X 10' DRIVEN GROUND RODS, COPPERCLAD, TO BE BUILDING STEEL ® 4 - #3/0 THWN CU 2" C. SEPARATED 6' -0" MINIMUM FOUNDATION �i3, VERIFY MINIMUM OF 1 - #2 THWN CU GROUND 1/2" C. 2 ELECTRICAL - RISER GIAGRAM E -1 SCALE: NTS ELECTRICAL LEGEND r SWITCH ( +48" CL, AFF UNLESS OTHERWISE NOTED.) BLANK = SINGLE POLE 2 = DOUBLE POLE 3 = THREE -WAY 4 = FOUR -WAY D = DIMMER K = KEY OPERATED X = EXPLOSION PROOF Mo= OCCUPANCY SENSOR DUPLEX RECEPTACLE, WALL. ( +18" CL, AFF UNLESS OTHERWISE NOTED.) "GFI" GROUND FAULT TYPE, "WP" WEATHER PROOF. TWO DUPLEX RECEPTACLES IN TWO GANG OUTLET BOX "D" DESIGNATION MEANSDEDICATED. ( +18" CL, AFF UNLESS OTHERWISE NOTED.) ® DUPLEX RECEPTACLE. FLOOR MOUNTED. - SINGLE RECEPTACLE, WALL MOUNTED. ( +18" CL, AFF UNLESS OTHERWISE NOTED.) DUPLEX RECEPTACLE. ( +48" CL, AFF UNLESS OTHERWISE NOTED.) SPECIAL PURPOSE RECEPTACLE. NEMA CONFIGURATION AS NOTED. WALL MOUNTED. 14 TELEPHONE OUTLET, WALL MOUNTED. DATA OUTLET, WALL MOUNTED. d COMB. DATA OUTLET- TELEPHONE OUTLET, WALL MOUNTED. ® TV OUTLET, WALL MOUNTED. Q JUNCTION BOX. a LIGHTING FIXTURE TYPE DESIGNATION. 2X4 FLUORESCENT LIGHTING FIXTURE. (THREE LAMPS 32 W (MAX) 120 V) CEILING MOUNTED (RECESSED) INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. -( - CEILING MOUNTED (SURFACE OR PENDANT) INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. Q-I WALL MOUNTED INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. �a DISCONNECT SWITCH. "a "= PHASE, "b "= AMP FRAME, "c "= AMP. FUSE "F "= FUSIBLE. C =0 NOT FUSED -z GROUND CONNECTION. \ BRANCH CKT HOME RUN. DENOTE NUM. OF UNGROUNDED SERVICE WIRE DENOTE NEUTRAL WIRE DENOTE GROUND WIRE ELECTRICAL PANEL r"I ELECTRICAL METER (=i CEILING MOUNTED EXIT LIGHT SIGN. (PROVIDE ARROWS AS INDICATED ON DRAWINGS.) WALL MOUNTED EXIT LIGHT SIGN. (PROVIDE ARROWS AS INDICATED ON DRAWINGS.) SELF - CONTAINED EMERGENCY LIGHTING UNIT, WALL. Qkf!j@ COMBO EXIT LIGHT SIGN AND SELF CONTAINED EMERGENCY LIGHTING UNIT. ELECTRICAL PANEL SCHEDULE FROM NEW FPL SERVICE WEATHER HEAD CONNECTION OPEN DELTA 120/24OV, 3PH, 4W I I 1 II MAINS: M.L.O. II 11 !I LL r 1 �EXISTING� 101 I I FUSE BUS 1 METER DISC. I I I 11 I L _ _ J 1-I I- O 20 VOLTAGE: ( A A A I L___ I NEW PANEL M.L.O. 200A 120/240V 3PH, 4W ELECTRICAL DEMOLITION NOTES 1. WHERE ELECTRIC LIGHTING FIXTURES, SWITCHES, RECEPTACLES, BOXES, CABINETS, DEVICES, ETC. ARE TO BE REMOVED, AND BOXES AND CONDUITS ARE TO REMAIN, ALL CONDUCTORS SHALL BE DE- ENERGIZED, DISCONNECTED AT BOTH ENDS, REVERSED INTO THE BOX, AND THE BOX PLUGGED WITH CEMENT PLASTER OR OTHER APPROVED MATERIAL AND THE WALL, FLOOR, CEILING AND THE LIKE, RESTORED TO MATCH THE SURROUNDING FINISH. 2. WHERE ELECTRICAL FIXTURES, SWITCHES, OUTLETS, RECEPTACLES, BOXES, CABINETS, DEVICES, ETC. ARE TO BE REMOVED, AND THEIR REMOVAL AFFECTS THE OPERATION OF THE EQUIPMENT, FIXTURE, RECEPTACLES, ETC., THAT IS TO REMAIN (INCLUDING ITEMS THAT MAY NOT BE SHOWN IN THE DRAWINGS BUT ARE PRESENTLY EXISTING IN PLACE) THE CONTRACTOR SHALL RE- CIRCUIT THEM (INCLUDING BOXES, CONDUIT, WIRES, ETC.) TO RESTORE THEM TO THE ORIGINAL OPERATING CONDITION. 3. UNUSED OPENINGS IN BOXES, CABINETS, PANELBOARDS, ETC., WHERE CONDUIT IS REMOVED OR PREVIOUSLY EXISTED, SHALL BE PLUGGED OR BLANKED OUT BY APPROVED METHODS, IF THE OPENING IS TO REMAIN. 4. ALL EXPOSED CONDUIT, WIRES, OUTLETS, ETC. NOT TO BE REUSED IN THE NEW REMODELED LAYOUT, SHALL BE REMOVED. 5. EXISTING CONDUIT RUNS, STUBBING UP THRU FLOORS IN AREAS WHERE WALLS ARE TO BE REMOVED, SHALL HAVE THEIR CONDUCTORS DE- ENERGIZED AND REMOVED, CONDUIT CUT -OFF GROUND FLUSH WITH FLOOR AND PLUGGED WITH CEMENT MORTAR OR ANY OTHER APPROVED MATERIAL. THE SAME APPLIES WITH EXISTING CONDUITS THAT ARE STUBBING OUT OF WALLS AND FLOORS. 6. WHERE PRACTICAL, EXISTING CONDUCTORS AND WIRES THAT ARE IN GOOD CONDITION, MAY BE REUSED IN PLACE AND INCORPORATED IN THE NEW REMODELED LAYOUT PROVIDED, IT IS OF PROPER SIZE, TYPE OF CONDUCTOR AND WITH THE APPROVAL OF THE OWNER. 7. ABANDONED CIRCUIT CONDUCTORS IN PANELBOARDS, SHALL BE DISCONNECTED, TAPED AND IDENTIFIED. 8. CONTRACTOR SHALL VISIT THE SITE, PRIOR BIDDING THIS WORK, TO FAMILIARIZE HIMSELF WITH THE STATUS OF THE SPACE. ALL THE REQUIRED DEMOLITION OR MODIFICATIONS (INCLUDING FIXTURES, OUTLETS, BOXES, PANELBOARDS, BREAKERS, TRANSFORMERS, ETC.) ARE TO BE INCLUDED IN THE WORK TO PERFORM IN ORDER TO HAVE A COMPLETE FINISHED INSTALLATION. 9. CONTRACTORS WORK SHALL BE FULLY COORDINATED WITH BUILDING SYSTEMS, AND ANY MODIFICATIONS, OR ADDITIONS THAT WILL ALTER THE BUILDING, SHALL BE MADE IN FULL COMPATIBILITY WITH THE SYSTEMS. WORK ON THE SYSTEMS AND WORK TO BE DONE IN NON- WORKING HOURS, IF REQUESTED, SHALL BE COORDINATED WITH THE BUILDING MANAGER, SPECIAL LIGHTING NOTES 1- REFER TO ARCHITECTURAL CEILING PLAN FOR EXACT LOCATION OF ALL LIGHT FIXTURES. 2- REFER TO ARCHITECTURAL ELEVATIONS FOR FINAL MOUNTING HEIGHTS OF ALL WALL MOUNTED LIGHT FIXTURES. UNLESS NOTED OTHERWISE, ARCHITECTURAL ELEVATIONS SHALL DICTATE MOUNTING HEIGHTS OF ALL FIXTURES. 3 COORDINATE FINAL PLACEMENT OF LIGHT FIXTURES IN ALL MECHANICAL SPACES WITH THE FINAL INSTALLED LOCATIONS OF ALL MECHANICAL DUCTWORK AND PIPING. 4- CONTRACTOR TO VERIFY FLUORESCENT LUMINARIES W /DOUBLE ENDED LAMPS TO BE PROVIDED W /INTERNAL DISCONNECTING MEANS TO DISCONNECT SIMULTANEOUSLY AL CONDUCTORS OF THE BALLAST, INCLUDING THE GROUNDED CONDUCTOR AS PER NEC 410.130 (Gi 5- CONTRACTOR TO VERIFY WITH OWNER ARCHITECT LIGHTING FIXTURE TYPE AND SPECIFICATIONS BEFORE INSTALLATION. 6- WIRE AHEAD OF ANY LOCAL SWITCHING FOR ALL EMERGENCY AND EXIT LIGHTS. 7- ADDITIONAL EXIT AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE FIELD FIRE INSPECTOR AT THE TIME OF THE FIRE FINAL. 8- INTERNALLY ILLUMINATED EXIST SIGN SHALL NOT EXCEED 5 WATTS PER SIDE AS PER FBC EC 505.4 9- RECESSED LUMINARIES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. ALL RECESSED LUMINARIES SHALL BE is -RATED AND LABELED AS MEETING ASTM E 283 (AIR TIGHT) AS PER FBC EC 502.3.8 10- EGRESS ILLUMINATION SHALL BE AT LEAST 1 FOOTCANDLE MEASURED AT THE FLOOR. F.B.C. EC 1006. 11- LIGHTING SYSTEM CONTROLS SHALL BE COMPLY WITH FBC EC 505 as] 0• Ikkkkammaki ZARA I • - - - -- DENOTES EXISTING EQUIPMENT /DEVICE/ OR CONDUIT 3 DENOTES NEW EQUIPMENT /DEVICE/ OR CONDUIT COLD WATER WIRING LEGEND PIPE 3 (D VERIFY MINIMUM OF 4 - #3/0 THWN CU 2" C. (2) 5/8" X 10' DRIVEN GROUND RODS, COPPERCLAD, TO BE BUILDING STEEL ® 4 - #3/0 THWN CU 2" C. SEPARATED 6' -0" MINIMUM FOUNDATION �i3, VERIFY MINIMUM OF 1 - #2 THWN CU GROUND 1/2" C. 2 ELECTRICAL - RISER GIAGRAM E -1 SCALE: NTS ELECTRICAL LEGEND r SWITCH ( +48" CL, AFF UNLESS OTHERWISE NOTED.) BLANK = SINGLE POLE 2 = DOUBLE POLE 3 = THREE -WAY 4 = FOUR -WAY D = DIMMER K = KEY OPERATED X = EXPLOSION PROOF Mo= OCCUPANCY SENSOR DUPLEX RECEPTACLE, WALL. ( +18" CL, AFF UNLESS OTHERWISE NOTED.) "GFI" GROUND FAULT TYPE, "WP" WEATHER PROOF. TWO DUPLEX RECEPTACLES IN TWO GANG OUTLET BOX "D" DESIGNATION MEANSDEDICATED. ( +18" CL, AFF UNLESS OTHERWISE NOTED.) ® DUPLEX RECEPTACLE. FLOOR MOUNTED. - SINGLE RECEPTACLE, WALL MOUNTED. ( +18" CL, AFF UNLESS OTHERWISE NOTED.) DUPLEX RECEPTACLE. ( +48" CL, AFF UNLESS OTHERWISE NOTED.) SPECIAL PURPOSE RECEPTACLE. NEMA CONFIGURATION AS NOTED. WALL MOUNTED. 14 TELEPHONE OUTLET, WALL MOUNTED. DATA OUTLET, WALL MOUNTED. d COMB. DATA OUTLET- TELEPHONE OUTLET, WALL MOUNTED. ® TV OUTLET, WALL MOUNTED. Q JUNCTION BOX. a LIGHTING FIXTURE TYPE DESIGNATION. 2X4 FLUORESCENT LIGHTING FIXTURE. (THREE LAMPS 32 W (MAX) 120 V) CEILING MOUNTED (RECESSED) INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. -( - CEILING MOUNTED (SURFACE OR PENDANT) INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. Q-I WALL MOUNTED INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. �a DISCONNECT SWITCH. "a "= PHASE, "b "= AMP FRAME, "c "= AMP. FUSE "F "= FUSIBLE. C =0 NOT FUSED -z GROUND CONNECTION. \ BRANCH CKT HOME RUN. DENOTE NUM. OF UNGROUNDED SERVICE WIRE DENOTE NEUTRAL WIRE DENOTE GROUND WIRE ELECTRICAL PANEL r"I ELECTRICAL METER (=i CEILING MOUNTED EXIT LIGHT SIGN. (PROVIDE ARROWS AS INDICATED ON DRAWINGS.) WALL MOUNTED EXIT LIGHT SIGN. (PROVIDE ARROWS AS INDICATED ON DRAWINGS.) SELF - CONTAINED EMERGENCY LIGHTING UNIT, WALL. Qkf!j@ COMBO EXIT LIGHT SIGN AND SELF CONTAINED EMERGENCY LIGHTING UNIT. 01 AMEN a LOAD CALCULATION PANEL ' NOTE: 3 PHASE LOAD PROVIDE SIGNS ON ELECTRICAL PANELS : "CAUTION: B Phase has 208 Volts to ELECTRIC FURNACE 15,000 VA Ground" STEAM HUMIDIFIER 13,500 VA TOTAL DEMANDED LOAD = 28,500 VA TOTAL DEMAND AMPS PER PHASE = 69 AMPS 1 PHASE LOAD TOTAL DEMANDED LOAD = 28,525 VA TOTAL DEMAND AMPS = 119 TOTAL AMPS PHASE "A" = 187 TOTAL AMPS PHASE "B" = 69 TOTAL AMPS PHASE "C" = 187 3 ELECTRICAL -PANEL SCHEDULE E -1 scALE: WS M c 0 V 1 w Of w a ~ Z W r`' Z E4 Q�-d- � � f W ►�- W 0000 a � � F_ QLn W z Q o a LL wLd z M Q D DO7d w Z J :z O -�-� pr) CD < > w �? J U I O w f�� LL_ OJ L� u7 o V J0 op O S u7 :2 i2 CD CD Lo Q 'd- Q W PO � U Q GT] W Q V) O f Q CN Q DRAWN M.C.S.R. CHECKED M.E.S. PROYEC MANAGER O.R. DATE FEBRUARY 2014 SCALE SHOWN JOB No. 2014 SHEET E -1 1 OF 2 SHEETS ELECTRICAL PANEL SCHEDULE 'A' TYPE: PANEL BOARD MAINS: M.L.O. MOUNTING: SURFACE 25,000 A.I.C. BUS RATING: 200 AMPS ENCLOSURE: NEMA 1 VOLTAGE: 120 /240- 3PHASE -4WIRE DESCRIPTION WIRE & LOAD POL CKT. PHASE LOAD KVA CKT. POLV LOAD WIRE & DESCRIPTION COND. SIZE (V.A.) TRIP NO- A *B C No. TRIP (V.A.) COND. SIZE 3 1 9,500 2 ELECTRIC FURNACE #8 -3/4" 15,000 3 9,500 4 /40 13,500 #8 -3/4" ELECTRIC FURNACE 50 5 9,500 6 SIGN #12 -1/2" 1,000 1 20 7 1,900 8 2 1,$00 #12 -1/2" EXISTING MINI SPACE(HIGH -LEG) 9 900 10 15 SPLIT SYSTEM LIGHTS #12 -1/2" 700 1 20 11 2,500 12 LIGHTS RECEPTION #12 -1/2" 700 1 20 13 2,500 4 X30 4,500 #10 -1/2" EWH SPACE(HIGH -LEG) 15 2,500 16 LIGHTS YOGA RM #12 -1/2" 1,300 1 20 17 3,800 18 ;X30. 5,000 #10 -1/2" DRYER LIGHTS CORRIDOR #12 -1/2" 900 1 20 1 19 2,400 20 1 1 20 1,500 #12 -1/2" WASHER SPACE(HIGH- LEG) 21 250 22 2 RECEP. RECEPTION #12 -1/2" 800 1 20 23 650 24 15 500 #12 -1/2" A H.U. RECEP. CONTROL RM #12-1/2" 600 j,--2'0 25 1,600 26 2 SPACE(HIGH -LEG) 27 1,000 28 15 2,000 #12-1/2 C.U. RECEP. OFFICE #12 -1/2" 800 1 20 29 1,800 30 1 20 1,000 #12 -1/2" WATER FOUNTAIN MAINTENANCE RECEP. #12-1/2" 400 2,,--2'0 31 1,900 32 1 20 1,500 # 12 -1 /2" BATH RECEPT. SPACE(HIGH -LEG) 33 0 34 SPACE(HIGH -LEG) GENERAL RECEP. #12 -1/2" 1,000 1 20 35 1,000 36 SPACE SPARE 1,500 1 20 37 1,500 38 SPACE SPACE(HIGH -LEG) 39 40 SPACE(HIGH -LEG) SPACE 41 42 SPACE 01 AMEN a LOAD CALCULATION PANEL ' NOTE: 3 PHASE LOAD PROVIDE SIGNS ON ELECTRICAL PANELS : "CAUTION: B Phase has 208 Volts to ELECTRIC FURNACE 15,000 VA Ground" STEAM HUMIDIFIER 13,500 VA TOTAL DEMANDED LOAD = 28,500 VA TOTAL DEMAND AMPS PER PHASE = 69 AMPS 1 PHASE LOAD TOTAL DEMANDED LOAD = 28,525 VA TOTAL DEMAND AMPS = 119 TOTAL AMPS PHASE "A" = 187 TOTAL AMPS PHASE "B" = 69 TOTAL AMPS PHASE "C" = 187 3 ELECTRICAL -PANEL SCHEDULE E -1 scALE: WS M c 0 V 1 w Of w a ~ Z W r`' Z E4 Q�-d- � � f W ►�- W 0000 a � � F_ QLn W z Q o a LL wLd z M Q D DO7d w Z J :z O -�-� pr) CD < > w �? J U I O w f�� LL_ OJ L� u7 o V J0 op O S u7 :2 i2 CD CD Lo Q 'd- Q W PO � U Q GT] W Q V) O f Q CN Q DRAWN M.C.S.R. CHECKED M.E.S. PROYEC MANAGER O.R. DATE FEBRUARY 2014 SCALE SHOWN JOB No. 2014 SHEET E -1 1 OF 2 SHEETS