15-310-010GRILLE, REGISTER & DIFFUSER SCHEDULE OUTSIDE AIR CALCULATIONS PLAN MARK MANUF. & MODEL NUMBER MODULE SIZE NECK SIZE FACE SIZE BORDER TYPE FINISH BLOW PATTERN MAT'L OPTIONS/NOTES A TITUS - CT480 SEE PLAN SEE PLAN SEE PLAN 1 01 1H ALU SBD / 1,2,3,4 B 11TUS - MCD -AA SEE PLAN SEE PLAN SEE PLAN 1 01 4 ALU OBD / 1,2,3 C TITUS - MCD -AA SEE PLAN SEE PLAN SEE PLAN 1 01 2C ALU OBD / 1,2,3 BORDER TYPE: 1 SURFACE BLOW PATTERN 1 1- WAY, FINISH 01 ALUMINUM OPTIONS SRA SQ. TO RD. ADAPT. EG EQUALIZING GRID T MOUNT 1H 1 -WAY, HORIZ. 04 MILL (STANDARD) PFA ALUM PLASTER FRAME TRV THROW RED. VANES 2 SNAP 1V 1 -WAY VERTICAL 2 2 -WAY, OPPOSITE 26 WHITE VD VOLUME DAMPER L FRONT BLADE LONG 3 LAY -IN 2C 2 -WAY, CORNER RD RADIAL DAMPER ORIENTATION 5. 4 SPLINE 3 3 -WAY MATERIAL ROBD RADIAL OBD S FRONT BLADE SHORT 5 DROPPED 4 4-WAY ST'L 22 GAUGE STEEL SBD SINGLE BLADE DAMPER ORIENTATION 6 BEVELED 5 RADIAL ALU ALUMINUM EQT EARTHQUAKE TABS C CONCEALED BORDER EACH EACH OBD OPPOSED BLD. DAMPER BO BLANK OFF NOTE 1. FOR BLOW PATTERN, REFER TO FLOW ARROWS INDICATED ON PLANS. ABSENCE OF FLOW ARROW INDICATES REMOVAL OF AIR PATTERN CONTROLLER UNLESS OTHERWISE SPECIFIED. 2. PROVIDE ADAPTER FOR DUCT CONNECTION TO DEVICE IF NECK SIZE AND DUCT SIZE DO NOT MATCH. /, AGE 3. CONFIRM BORDER TYPE AND FINISH WITH ARCHITECT /OWNER PRIOR TO PURCHASING. 4. SINGLE BLADE DAMPER (MODEL AG -30) TO BE SCREW DRIVER ADJUSTABLE FROM FACE OF DIFFUSER. 5. OPPOSED BLADE DAMPER (MODEL AG -95) TO BE ADJUSTABLE FROM THE DIFFUSER FACE BY REMOVING CORE MODULE. HVAC DESIGN REQUIREMENTS YES NO OUTSIDE AIR CALCULATIONS - �� ABLE TYPE/ - X 403,3a� APPLICATION X AREA PEOPLE/ NO. OF CFM/P CFM/ CFM CFM CFM PROVIDED BY SONES SMOKE CONTROL SO. FT. 1000 SQFT PEOPLE CAPACITY SO. FT. REQUIRED PROVIDED RETAIL MODEL NO. 490 15 8 7.5 0.12 119 130 CFM HP WEIGHT ENTERING AIR TEMP; TEF -1 GREENHECK SP -950 BATHROOM 50 0.1 0.5A PKU -1 (150 CFM) STORAGE DIRECT 163 - - 0 0.12 20 20 CFM 3. NOTES: 4. SEE GENERAL, AIR CONDITIONING, DUCTWORK, AND COORDINATION NOTES FOR OTHER FIELD SUPPLIED ITEMS. 5. 1) O/A EXCLUSION BASED ON DEFINITION OF OCCUPIABLE SPACE. PROVIDE FACTORY FAN MOUNTING SUPPORT -LEGS, CURBS, HANGING CUPS, ETC.. 7. HVAC DESIGN REQUIREMENTS YES NO FAN SCHEDULE - SELECTION BASED ON TYPE/ - X MOTOR DATA - X UNIT - MARK FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - CFM IN WG. DRIVE SONES SMOKE CONTROL NOTES X ELECTRICAL CAPACITY UNIT MAKE MODEL NO. SERVICE PKU HP RPM VOLTS-PH-HZ ESP HP WEIGHT ENTERING AIR TEMP; TEF -1 GREENHECK SP -950 BATHROOM 50 0.1 0.5A 594 115 -1 -60 DIRECT 1.1 11 LB 1 -8 gENERAL 1. FAN NOTES: PROVIDE MOTOR STARTERS, DISCONNECTS AND ALL ASSOCIATED CONTROLS ON ALL FANS. 2. PROVIDE BACKDRAFT DAMPER FOR ALL EXHAUST FANS. 3. COORDINATE WITH ELECTRICAL. CONTRACTOR BEFORE BIDDING OR ORDERING ANY EQUIPMENT. 4. SEE GENERAL, AIR CONDITIONING, DUCTWORK, AND COORDINATION NOTES FOR OTHER FIELD SUPPLIED ITEMS. 5. PROVIDE MOTOR HEATERS SIZED AS REQUIRED FOR FIELD CONDITIONS. 6. PROVIDE FACTORY FAN MOUNTING SUPPORT -LEGS, CURBS, HANGING CUPS, ETC.. 7. TEF -1 TO BE INTERLOCKED WITH PKU -1. 8. PROVIDE ALUMINUM GRULLE WITH WHITE ENAMEL FINISH. HVAC DESIGN REQUIREMENTS YES NO DUCT SMOKE DETECTOR - X FIRE DAMPER(S) - X SMOKE DAMPER(S) - X FIRE RATED ENCLOSURE - X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - X FIRE STOPPING - X SMOKE CONTROL - X DRAWING KEY NOTES Q 4 "0 TOILET EXHAUST FAN TO EXISTING WALL CAP. PROVIDE BACKDRAFT DAMPER. CONTRACTOR TO EXTEND EXISTING DUCTWORK AS NECESSARY IN ORDER TO CONNECT TO NEW TEF -1. SEPERATE 10' -0" MINIMUM FROM MECHANICAL INTAKE OPENING. PROGRAMMABLE THERMOSTAT AT 48" A.F.F. COORDINATE FINAL LOCATION WITH OWNER /ENGINEER FOR APPROVAL. CONTRACTOR TO PROVIDE SOFFIT TO ACCOMODATE DUCTWORK. COORDINATE EXACT LOCATION OF SOFFIT WITH ARCHITECT. REPORT ANY DISCREPENCY TO ENGINEER. �¢ NEW AIR - COOLED PACKAGED UNIT TO BE INSTALLED ON NEW WALL SUPPORT BRACKET. REFER TO STRUCTURAL ENGINEER FOR DETAILS. CONTRACTOR TO FIELD VERIFY REQUIRED BRACKET SIZE IN ORDER TO PROVIDE ADEQUATE CLEARANCE ABOVE CONDENSER FAN. REFER TO MANUFACTURERS SPECIFICATIONS. REPORT ANY DISCREPENCY TO ENGINEER. 18 "x12" MIAMI -DADE APPROVED HURRICANE RESISTANT LOUVER TO BE INSTALLED ABOVE WINDOW. PROVIDE PLENUM AND CORROSION RESISTANT INSECT SCREEN. MANUFACTURER - GREENHECK MODEL ESD -635D OR APPROVED EQUAL. RETURN PLENUM ABOVE CEILING. PLENUM ENCLOSURES SHALL BE CONSTRUCTED OF MATERIALS PERMITTED FOR THE TYPE OF CONSTRUCTION CLASSIFICATION PER FMC 602.2. ALL MATERIALS WITHIN PLENUM TO BE IN COMPLIENCE WITH FMC 602.2.1. CONTRACTOR TO TRANSITION AND EXTEND RETURN DUCT FAR ABOVE CEILING TO MECHANICALLY ATTACH INTAKE DUCT. FIELD VERIFY CLEARANCES AND CONSTRAINTS. REPORT ANY DISCREPENCY TO ENGINEER. 4"O FLEXIBLE DUCT TAPPED OFF TOP OF MAIN TRUNK. CONTRACTOR TO RUN ABOVE CEILING BETWEEN TRUSS WEBBING. (TYPICAL) MOTORIZED DAMPER (NORMALLY OPEN) INTERLOCKED WITH PKU -1 COMPRESSOR, TURN TO OPEN WHEN COOLING ENGAGED, RETURN TO CLOSED POSITION WHEN COMPRESSOR STOP. j p CONTRACTOR TO FIELD COORDINATE EXACT PLACEMENT OF UNIT IN ORDER TO PENETRATE EXISTING 40 "x19" EXTERIOR WALL PENETRATION WITH SUPPLY AND RETURN DUCTWORK. CONTRACTOR TO VERIFY ALL CLEARANCE AND CONSTRAINTS ON SITE IN ORDER TO ADEQUATELY CLEAR BEAM. CONTRACTOR TO TRANSITION ACCORDINGLY UNDER BAR JOIST'S INTO SOFFIT ALONG WEST EXTERIOR WALL. REPORT ANY DISCREPENCY TO ENGINEER. j j CONTRACTOR TO FIELD INSTALL ELECTRIC DUCT HEATER FROM MANUFACTURER ON DISCHARGE OF UNIT. REFER TO MANUFACTURERS SPECIFICATIONS FOR DETAILS. _12') CONTRACTOR TO PROVIDE 90' ELBOW OFF RETURN DIFFUSER. ENTIRE SHEET REVISED: OWNER REQUESTED REVISIONS 03.11.15 0 0 MECHANICAL CEILING PLAN SCALE:114 "=1' -0" c n )OM F.F. a 14 o� oa a w� �Q 4'4 w R f-'4� o� R ati o 2 w� o^ Q 2 0 w 2 c: w� �l c2 Q w� o� a� V. o a a z x z ° G p= c� 6 ads E� �El a ow �o 71 Tr5 N Ca r 1 AIR COOLED PACKAGED UNIT EQUIPMENT SCHEDULE MARK DESIGN MANUFACTURER CFM EVAPORATOR COMPRESSOR CONDENSER HEATER HEATER MAX UNIT MAX ELECTRICAL CAPACITY UNIT R/A FILTER PKU MODEL NO. TAR OUTSIDE ESP HP FLA ENTERING AIR TEMP; LEAVING R TEMP-, N0. R NO. (fA � KW NO. OF STAGES MCA FUSE MCA FUSE VOLTS -PH -HZ TMBH SMBH SEER TYPE REFRIGERANT OPERATING UNIT DIMENSIONS AND QUANTITY AREA SERVED LOCATION APPLICABLE NOTES F 8 F EACH EACH FAN (EA) /, AGE � DIMENSIONS PKU -1 BARD PA13362 -A 1,240 140 0.5" 1/2 3.3 80/67 - 1 - 12/74 PROP. 1 1/6 1.1 ELEC. 5 1/5 26 30 24 35 230 -1 -60 34,000 25,500 13.0 HORIZONTAL R -41 OA 410 x38.125 MERV� 6 PLAN - 1 -6 PLAN NOTES: 1) RATED AND CERTIFIED IN ACCORDANCE WITH ANSI /AHRI STANDARD 210/240 -2003 5) PROVIDE LIQUID LINE FILTER DRIER. 2) PROVIDE PROGRAMMABLE THERMOSTAT 6) PROVIDE FIELD INSTALLED ELECTRIC HEATER AS SPECIFIED. ELECTRIC HEATER REQUIRES INDIVIDUAL POWER CIRCUIT. 3) PROVIDE ECM INDOOR BLOWER MOTOR 4) PROVIDE ALUMINUM FINNED COPPER COILS. 0 0 MECHANICAL CEILING PLAN SCALE:114 "=1' -0" c n )OM F.F. a 14 o� oa a w� �Q 4'4 w R f-'4� o� R ati o 2 w� o^ Q 2 0 w 2 c: w� �l c2 Q w� o� a� V. o a a z x z ° G p= c� 6 ads E� �El a ow �o 71 Tr5 N Ca r 1