15-310-007ELECTRICAL SYMBOL LEGEND BASIC MATERIALS SYMB ❑L DESCRIPTI ❑N DUPLEX RECEPTACLE, E 20 AMP. 125 , V., M.H. 18 A.F.F. ( ) TEW RECEPTACLE (16" A.F.F.) (EWC DENOTES ELECTRIC WATER COOLER. COORDINATE WITH EWC INSTALLER FOR MOUNTING HEIGHT TWO DUPLEX RECEPTACLES WITH COMMON COVER 20A., 125V.,(18" A.F.F.) SPECIAL PURPOSE OUTLET, CORRD. W/ EQUIPT. DUPLEX RECEPTACLE, 20 AMP,, 125V ", MOUNT ABOVE COUNTER 042 "AFF. GFCI DUPLEX RECEPTACLE, 20 AMP., 125V., (M.H.= 18 "A.F.F.) GFCI DUPLEX RECEPTACLE, 20 AMP., 125V., MTD. ABOVE COUNTER (VERIFY HEIGHT) ® DUPLEX RECEPTACLE, 20 AMP., 125V., MOUNTED IN BOTTOM OF CEILING SOFFIT FOR SHOW WINDOW LIGHTING ® FLOOR OUTLET BOX AND DUPLEX RECEPT. 20 AMP., 125V., WITH APPROPRIATE FLANGE. Q JUNCTION BOX, MOUNTING AS SHOWN ELECTRIC MOTOR, NUMBER INDICATES HORSEPOWER -# OF POLES ENCLOSURE TYPE: �r-° -- AMP RATING /FRAME NEMA 3R- FOR EXTERIOR NEMA 1- 1313 FOR INTERIOR - -R SE SIZE( • DENOTES AS PER MANUFACTURER) LIGHTING CONTROL TIME CLOCK PHOTOCELL, MOUNTED ON ROOF FACING NORTH ® SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS OTHERWISE NOTED ® PLUG -IN STRIP WITH RECEPTACLES, 18" O.C. U.O.N. ® CABLE TRAY 1I�-- GROUND OR GROUND ROD AS NOTED -0 CONDUIT TURNING UP 3 CONDUIT STUB -'� CONDUIT TURNING DOWN CONDUIT CONTINUED LIGHTING (REFER TO LIGHTING FIXTURE SCHEDULE FOR SPECS.) SYMBOL DESCRIPTION A LIGHT FIXTURE DESIGNATION. {- LIGHTING FIXTURE, SURFACE MOUNTED 0 LIGHTING FIXTURE (HID, FLUORESCENT OR INCANDESCENT), RECESSED MID. LIGHTING FIXTURE, WALL MOUNTED 1:81 EXIT LIGHT FIXTURE. DIRECTION ARROWS AS SHOWN WALL MOUNTED EXIT LIGHT FIXTURE (SHADED QUADRANT INDICATES FACE(S) OF FIXTURE) 2 X 2 FLUORESCENT LIGHT FIXTURE 2 X 4 FLUORESCENT LIGHT FIXTURE DIAGONAL SHADING DENOTES LIGHT FIXTURE CONNECTED TO EMERGENCY BRANCH CIRCUIT OR, W /EMERG. BATTERY PACK. 4� COMBINATION OF EXIT SIGN & EMERGENCY BATTERY WALL PACK WITH TWIN HEADS (REFER TO LTG. FIXTURE SCHEDULE FOR SPECS.) EMERGENCY BATTERY WALL PACK WITH TWIN HEADS TOGGLE SWITCH 120/277V. 20 AMP.,(M.H. =48" A.F.F.) $3 TOGGLE SWITCH 120/277V. 20 AMP. ,(M.H. = 48" A.F.F.) , 3 -WAY $w SINGLE PHASE MANUAL MOTOR STARTER, (M.H. =48" A.F.F.) $D DIMMER SWITCH (M.H. = 48" A.F.F.) OCCUPANCY SENSOR NOTES: o,b WALL MOUNTED - OCCUPANCY SENSOR SWITCH,(M.H.= 487A.F.F.) MFGR. /M# (SENSOR SWITCH / #WSD- PDT -1 P(2P) IF NEEDED) a,b INDICATES SWITCHING @ CEILING MOUNTED OCCUPANCY SENSOR - LIGHTING CIRCUIT CONTROLLER. MFGR. /MODEL# (SENSOR SWITCH /#CM -PDT) 1. COORDINATE AND VERIFY EXACT PLACEMENT OF ALL OCCUPANCY SENSORS WITH MANUFACTURER PRIOR TO COMMENCEMENT OF WORK. 2. OCCUPANCY SENSORS: ANY LOAD OVER 80OW 0120V AND 120OW 0277V CONTRACTOR SHALL UTILIZE LOW VOLTAGE OCCUPANCY SENSORS WITH REMOTE POWER PACKS AS REQUIRED BY MANUFACTURER. 3. CONTRACTOR SHALL PROVIDE ALL SWITCHPACKS AND CONDUCTORS AS REQUIRED FOR LAYOUTS AND CONTROLS SHOWN ON PLANS. B WALL MOUNTED LV NFP SWITCH (M.H.= 487A.F.F.) #B INDICATES NUMBER OF t�-ff BUTTONS SERVICE AND DISTRIBUTION SYMBOL DESCRIPTION ELECTRICAL BRANCH CIRCUIT PANELBOARD, RECESS MOUNTED. ------- ---- (SEE PANEL SCHEDULE FOR DETAILS) .... ELECTRICAL BRANCH CIRCUIT PANELBOARD, SURFACE MOUNTED. - -- - (SEE PANEL SCHEDULE FOR DETAILS) -------- EXISTING EQUIPMENT TO REMAIN NEW EQUIPMENT OR WORK OF THIS PROJECT LM CIRCUIT BREAKER, TYPE AND SIZE AS PER DRAWINGS. TELEPHONE /COMPUTER RACEWAY SYSTEM SYMBOL DESCRIPTION TELEPHONE /COMPUTER TERMINAL BOARD "TTB" INTERCOM SYSTEM SPEAKER COMPUTER/TELEPHONE OUTLET IN A SINGLE -GANG BOX MOUNTED AT 18" A.F.F. C = ABOVE THE COUNTER P = PUBLIC PAY (48" A.F.F.) W = WALL MOUNTED (18" A.F.F. FIRE ALARM /DETECTION SYSTEM SYMBOL DESCRIPTION 15P75 CD VISUAL SIGNALING UNIT- FLASHING STROBE LIGHT ONLY (80" TO BOTTOM)(NO AUDIO DEVICE) aw DUCT MOUNTED SMOKE DETECTOR, WITH SAMPLE TUBE, REMOTE TEST AND HEAVY DUTY CONTROL RELAY. GENERAL CONTRACTOR TO VERIFY MOUNTING HEIGHT OF ALL DEVICES WITH NOTE: ARCHITECT PRIOR TO DEVICE INSTALLATION. I GENERAL ELECTRICAL NOTES 1. THE ENTIRE INSTALLATION SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE 2008 NEC FLORIDA BUILDING N CODE 2010 FBC, 2010 FLORIDA FIRE PREVENTION CODE, NFPA 1 & NFPA 101 2006 EDITIONS AND THE LATEST EDITIONS OF ALL LOCAL CODES, RULES AND ORDINANCES HAVING JURISDICTION. 2. AS A MINIMUM, ALL EQUIPMENT SHALL MEET APPLICABLE STANDARDS, FOR TYPE OF EQUIPMENT AND INTENDED USE, OF THE FOLLOWING: a, AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). b. ILLUMINATING ENGINEERS SOCIETY (IES). c. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). d. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA). NOTE: THESE STANDARDS ARE SUBORDINATE TO CODES AND STANDARDS SET BY U.L 3. IT SHALL BE UNDERSTOOD THAT ALL WORK PERFORMED SHALL BE BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. SAID CONTRACTOR SHALL MEET ALL REQUIREMENTS SET FORTH BY ANY LOCAL ORDINANCE AND GOVERNING AUTHORITIES, 4" THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 5. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM DATE OF ACCEPTANCE, U.O.N. 6. IT SHALL NOT BE THE INTENT OF THESE PLANS AND /OR SPECIFICATIONS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR SHALL BE EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 7, THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING TO ORIGINAL CONDITIONS, ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT, ETC. CAUSED DURING THE PERFORMANCE OF WORK. 8. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE OR DELAYS AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 9. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. 10. THE CONTRACTOR SHALL NOT SCALE THE ELECTRICAL DRAWINGS, REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT UNLESS NOTED OTHERWISE. 11. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS SHOWN AND /OR NOTED ON THE PLANS. 12. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR FOR THE ADVANCE ORDERING OF LONG LEAD ITEMS, AS TO NOT INTEFERE WITH THE PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. THE CONTRACTOR SHALL NOT ORDER ANY ITEMS UNTIL APPROVED SHOP DRAWINGS ARE RETURNED TO HIM. 13. THE CONTRACTOR SHALL KEEP ALL AREAS WHERE WORK IS BEING PERFORMED FREE FROM DEBRIS AT ALL TIMES AND SAID AREAS SHALL BE LEFT BROOM CLEAN AT THE END OF EA. WORKING DAY. 14. ALL CONDUCTORS SHALL BE COPPER, TYPE THHN/THWN EXCEPT WHERE OTHERWISE REQUIRED BY U.L OR CODES. MINIMUM WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING. 15. ALUMINUM CONDUCTORS ARE NOT PERMITTED ANYWHERE. 16. ALL CONDUCTORS SHALL BE IN 1/2" MIN. CONDUITS. ALL CONDUITS SHALL BE GALVANIZED RIGID STEEL (GRS) EXCEPT THAT: (a) PVC CONDUITS MAY BE USED UNDERGROUND PROVIDED ELBOWS AND RISERS ARE GRS, WHERE SUBJECT TO PHYSICAL DAMAGE (b) ELECTRICAL. METALLIC TUBING (EMT) MAY BE USED IN OR ON WALLS OR CEILINGS WHERE NOT SUBJECT TO MECHANICAL DAMAGE, DAMP OR CORROSIVE CONDITIONS, (c) LIQUID TIGHT FLEXIBLE CONDUIT WHERE REQUIRED, (d) FLEXIBLE METALLIC CONDUIT WHERE REQUIRED IN DRY LOCATIONS ONLY. ALL CONDUITS IN HAZARDOUS AREAS (PER NEC) SHALL MEET THE REQUIREMENTS OF NEC CH. 5. 17. ALL CONDUIT RUNS ARE SHOWN DIAGRAMATICALLY. THE EXACT ROUTING SHALL BE DETERMINED IN THE FIELD. UNLESS NOTED OTHERWISE. 18. WHERE CORE DRILLING OF FLOORS/WALLS IS REQUIRED, THE CONTRACTOR SHALL SEAL OPENINGS WATERTIGHT AFTER UTILITIES HAVE BEEN INSTALLED. LOCATION OF CORED HOLES SHALL COORDINATE WITH LOCATION OF EQUIPMENT IN A MANNER THAT IS CLEAN AND FUNCTIONAL. THE CONTRACTOR SHALL INSTALL ONLY ONE CONDUIT PER HOLE AND SEAL THE OPENING AROUND THE CONDUIT. 19. PROVIDE FIRE RETARDANT U.L APPROVED SEALANT ON ALL PENETRATIONS, WALLS AND STRUCTURAL SLABS. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY PRIOR TO SUBMITTING BID, THE LOCATIONS OF ALL SUCH FIRE RATED PARTITIONS, WALLS, AND STRUCTURAL SLABS. 20. UNLESS NOTED AS EXISTING, ALL EQUIPMENT, WIRING, DEVICES, ETC. SHALL BE NEW. 21. ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC REQUIREMENTS TO ACCOMODATE EQUIPMENT SERVED, INCLUDING REQUIRED FUSES U.O.N. SWITCHES SHALL BE HORSEPOWER RATED FOR MAX. HORSEPOWER, HEAVY DUTY TYPE. 22. THE CONTRACTOR SHALL VERIFY CIRCUIT PROTECTIVE DEVICE RATINGS FOR EQUIPMENT PRIOR TO INSTALLATION. 23. ALL FUSES SHALL BE CURRENT LIMITING, PER U.L. RATED 60OV. OR 250V. AS REQUIRED, WITH: (a) NON TIME DELAY FUSES IN MAIN SWITCHES AND SWITCHES FEEDING PANELS. (b) TIME DELAY FUSES FOR MOTOR AND HVAC CIRCUITS. 24. WIREWAYS SHALL BE SIZED AS REQUIRED, PER NEC, U.O.N. 25. ALL CIRCUIT BREAKERS SHALL BE INVERSE TIME TYPE (THERMAL - MAGNETIC). TWO AND THREE POLE CIRCUIT BREAKERS SHALL BE COMMON TRIP. TIE HANDLES ARE NOT PERMITTED. 26. ALL ELECTRICAL EQUIPMENT SHALL BE RAINTIGHT (NEMA 3R) WHERE EXPOSED TO THE WEATHER. ALL FLEX CONDUITS CONNECTED TO SUCH EQUIPMENT SHALL BE LIQUIDTIGHT. 27. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES AS REQUIRED FOR OTHER CLASSIFIED AREAS. U.O.N. 28. ALL CONNECTIONS TO GROUND RODS SHALL BE MADE WITH U.L APPROVED WELDED CONNECTIONS, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL FORM A GROUNDING ELECTRODE SYSTEM AS PER NEC 250 -50. 29. FOR EMERGENCY EXIT SIGNS AND EMERGENCY BATTERY PACKS MAKE CONNECTION AHEAD OF ALL SWITCHES. 30. PROPER PLASTER RINGS SHALL BE USED WITH OUTLET BOXES. PLASTER RINGS SHALL BE A MAXIMUM OF 1/8" FROM THE FINISHED SURFACE OF THE DRYWALL AFTER THE DRYWALL IS INSTALLED, PROPER COORDINATION BETWEEN THE ELECTRICAL CONTRACTOR AND THE GENERAL CONTRACTOR FOR RING INSTALLATION IS REQUIRED. NO "GOOF" RINGS WILL BE ALLOWED. ALL OUTLET BOXES SHALL BE SECURELY FASTENED. ANY AND ALL IMPROPERLY INSTALLED PLASTER RINGS OR OUTLET BOXES SHALL BE REMOVED AND A NEW RING OR OUTLET INSTALLED AT THE CONTRACTOR'S EXPENSE. 31. THE CONTRACTOR SHALL SUBMIT 6 COPIES OF EQUIPMENT SHOP DRAWINGS FOR ELECTRICAL EQUIPMENT TO THE ENGINEER FOR REVIEW, PRIOR TO ORDERING SUCH EQUIPMENT. 06]'0 ` f IM momp 1. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A D WILL ILL BE EVIDENCE THAT SUCH AN EXAMINATION A ON HAS BEEN MADE. LATER CLAIMS FOR LABOR EQUIPMENT, MATERIALS Q , 0 R ATER ALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. 2. THE CONTRACTOR SHALL NOT SCALE THE ELECTRICAL DRAWINGS, REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS SHOWN AND /OR NOTED ON THE PLANS. 4. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR FOR THE ADVANCE ORDERING OF LONG LEAD ITEMS, AS TO NOT INTEFERE WITH THE PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. THE CONTRACTOR SHALL NOT ORDER ANY ITEMS UNTIL APPROVED SHOP DRAWINGS ARE RETURNED TO HIM. 5. THE CONTRACTOR SHALL KEEP ALL AREAS WHERE WORK IS BEING PERFORMED FREE FROM DEBRIS AT ALL TIMES AND SAID AREAS SHALL BE LEFT BROOM CLEAN AT THE END OF EACH WORK -DAY. 6. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL WORK OUTSIDE LEASE SPACE WITH LANDLORD, ANY WORK OUTSIDE OF LEASE MUST BE PERFORMED AFTER 7 PM AND COMPLETE BY 7 AM. AREAS MUST BE CLEAN AND READY FOR BUILDING OCCUPANCY BY 6:00 AM EVERY MORNING. 7. COORDINATION DETAILS OF ALL TRADES SHALL BE RESPONSIBILITY OF THE GENERAL CONTRACTOR. FBC CODE COMPLIANCE STATEMENTS: 1" AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, OPERATION AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE WITH CLEARLY IDENTIFIED REQUIRED ROUTINE MAINTENANCE ACTIONS, AND NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. FBC EC 505.7.4.2. 2" WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. FBC EC 505.7.4.1. 120\ LINE COIL CLEARING CONTACTS !I 2 A -7 1F ASW REC. 2 A -5 I-- I- SIGNAGE 3 -- f- ( SPARE -- 4 I SPARE L_ _ J 7 -DAY, 24 -HOUR PROGRAMMABLE TIME CLOCK 4 POLE, 30 AMP LIGHTING CONTACTOR MECHANICALLY HELD TIME SCHEDULE: LIGHTING TO BE TURNED ON VIA TIMECLOCK AT A TIME DETERMINED BY OWNER LIGHTS TO SWEEP OFF AT A TIME DETERMINED BY OWNER. TYPICAL LIGHTING CONTACTOR SCALE, N.T.S TENANT - McLAUGHLIN STORE NEW PANEL 'A' 120/240V 10 3W NEMA 1 EXISTING 4A DETAIL REFERENCE 1. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND Q SHEET NUMBER REFERENCE Project #: 150201 SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A BID C`7 E -3 MANUFACTURER: SquareD or Equal WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN %M BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. TO THIS PROJECT. 2. THE CONTRACTOR SHALL NOT SCALE THE ELECTRICAL DRAWINGS, REFER TO ARCHITECTURAL "ALL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT UNLESS NOTED OTHERWISE. EXISTING CONDITIONS NOTES 3. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL LABOR, O O O PHASE MATERIALS AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS SHOWN AND /OR 6 LIRYXALL FACE PLATE NOTED ON THE PLANS. MAIN LUGS: 100 AMPS 4. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR FOR THE ADVANCE 1. I PRIOR TO SUBMITTING BIDS, THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO LESS THAN 24' APART, OR WHERE BOX PLACEMENT IN 100 SQ. FT. OF ANY WALL ORDERING OF LONG LEAD ITEMS, AS TO NOT INTEFERE WITH THE PRODUCTION OF OTHER `VERIFY EXISTING ELECTRICAL EQUIPMENT CONDITIONS AND DIFFICULTIES THAT WILL cn z O TRADES RESULTING IN ANY DOWN OR LAG TIME. THE CONTRACTOR SHALL NOT ORDER ANY AFFECT EXECUTION OF THE WORK. FOLD VERIFY QUANTITIES OF EXISTING LIGHT ITEMS UNTIL APPROVED SHOP DRAWINGS ARE RETURNED TO HIM. FIXTURES, ELECTRICAL DEVICES, COMMUNICATION DEVICES, FIRE ALARM DEVICES, AND 5" THE CONTRACTOR SHALL KEEP ALL AREAS WHERE WORK IS BEING PERFORMED FREE FROM ELECTRICAL EQUIPMENT AS APPLICABLE. NOTIFY THE ARCHITECT AND ENGINEER OF 6 DEBRIS AT ALL. TIMES AND SAID AREAS SHALL BE LEFT BROOM CLEAN AT THE END OF EACH ANY EXISTING CONDITIONS, WHICH WILL EFFECT THE SCOPE OF WORK AS SHOWN ON ;%•. ��; WORKING DAY. THE CONSTRUCTION DOCUMENTS. SUBMISSION OF A BID PROPOSAL WILL BE MOUNTING: RECESSED CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE AND LATER 7• IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL WORK OUTSIDE LEASE CLAIMS FOR MOBILIZATION, LABOR, EQUIPMENT, AND /OR MATERIALS REQUIRED SPACE WITH LANDLORD. ANY WORK OUTSIDE OF LEASE MUST BE PERFORMED AFTER 7 PM AN[ BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. COMPLETE BY 7 AM. AREAS MUST BE CLEAN AND READY FOR BUILDING OCCUPANCY BY 6:00 AM EVERY MORNING. 2. PROVIDE FIRE RETARDANT U.L. APPROVED SEALANT ON ALL PENETRATIONS, WALLS AA 26oO2514 - IB 26o01404 1141 SE 6th TERRACE AND STRUCTURAL SLABS. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL 8. COORDINATION DETAILS OF ALL TRADES SHALL BE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY PRIOR TO SUBMITTING BID, THE LOCATIONS OF ALL SUCH CONTRACTOR. FIRE RATED PARTITIONS, WALLS, AND STRUCTURAL SLABS. i W ° momp 1. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A D WILL ILL BE EVIDENCE THAT SUCH AN EXAMINATION A ON HAS BEEN MADE. LATER CLAIMS FOR LABOR EQUIPMENT, MATERIALS Q , 0 R ATER ALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. 2. THE CONTRACTOR SHALL NOT SCALE THE ELECTRICAL DRAWINGS, REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS SHOWN AND /OR NOTED ON THE PLANS. 4. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR FOR THE ADVANCE ORDERING OF LONG LEAD ITEMS, AS TO NOT INTEFERE WITH THE PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. THE CONTRACTOR SHALL NOT ORDER ANY ITEMS UNTIL APPROVED SHOP DRAWINGS ARE RETURNED TO HIM. 5. THE CONTRACTOR SHALL KEEP ALL AREAS WHERE WORK IS BEING PERFORMED FREE FROM DEBRIS AT ALL TIMES AND SAID AREAS SHALL BE LEFT BROOM CLEAN AT THE END OF EACH WORK -DAY. 6. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL WORK OUTSIDE LEASE SPACE WITH LANDLORD, ANY WORK OUTSIDE OF LEASE MUST BE PERFORMED AFTER 7 PM AND COMPLETE BY 7 AM. AREAS MUST BE CLEAN AND READY FOR BUILDING OCCUPANCY BY 6:00 AM EVERY MORNING. 7. COORDINATION DETAILS OF ALL TRADES SHALL BE RESPONSIBILITY OF THE GENERAL CONTRACTOR. FBC CODE COMPLIANCE STATEMENTS: 1" AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, OPERATION AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE WITH CLEARLY IDENTIFIED REQUIRED ROUTINE MAINTENANCE ACTIONS, AND NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. FBC EC 505.7.4.2. 2" WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. FBC EC 505.7.4.1. 120\ LINE COIL CLEARING CONTACTS !I 2 A -7 1F ASW REC. 2 A -5 I-- I- SIGNAGE 3 -- f- ( SPARE -- 4 I SPARE L_ _ J 7 -DAY, 24 -HOUR PROGRAMMABLE TIME CLOCK 4 POLE, 30 AMP LIGHTING CONTACTOR MECHANICALLY HELD TIME SCHEDULE: LIGHTING TO BE TURNED ON VIA TIMECLOCK AT A TIME DETERMINED BY OWNER LIGHTS TO SWEEP OFF AT A TIME DETERMINED BY OWNER. TYPICAL LIGHTING CONTACTOR SCALE, N.T.S TENANT - McLAUGHLIN STORE NEW PANEL 'A' 120/240V 10 3W NEMA 1 EXISTING EXISTING SUB -PANEL PANEL 0 Q ".Z> Project #: 150201 v; s: C`7 F -2 ?0/240V 10 3W NEMA 1 F -1 ELECTRICAL DRAWING INDEX DRAWING DESCRIPTION 1 EO.1 ELECTRICAL GENERAL NOTES, SYMBOLS AND DETAILS, RISER, SCHEDULES ..........._ ...... .... .......... ......... .. .... .. ... . ...... .._...,.._..._ ._............_.._- ..._...._... --------- - - - - -- _ ......._......_....._.- .._. -... -...-.....- ....._.................._..... 2 E1 "1 ELECTRICAL FLOOR PLAN, NOTES AND LIGHTING FIXTURE SCHEDULE K '�• ke7% i I AREA 0 WORK 120/240v 1 PH 3W /� 1 1 #5 EXISTING LOAD WIREWAY TO TENANTS TO TENANTS _________ __ _- ----- ------------- 1 _ ----------- - ___ -_ --1 HOUSE 1 ' f' - - --'1 PARTIAL EXISTING ELECTRICAL RISER N,T,S, A B ll C �n Sf .� uj r l Ftia V Y.; .,r rx f >4� s r �4 W 1"r1 ry rte - U W) 4 0"_ !,4 w r, NEW Panel Name: A ".Z> Project #: 150201 v; s: C`7 MANUFACTURER: SquareD or Equal 24' MIOIUM SEP11RAli0N %M _w INTERIOR MODIFICATIONS N "ALL MtfTAI TIP 4' X 4' ElECTtaCAL BOX ' STUD 7 O O O PHASE : MUD ROIL 6 LIRYXALL FACE PLATE = ".. MAIN LUGS: 100 AMPS APPLY 1/4' OF U.L. RATED INTUMESCENT COMPOUND INHERE BOXES ARE INSTALLED Yi LESS THAN 24' APART, OR WHERE BOX PLACEMENT IN 100 SQ. FT. OF ANY WALL s EXCEEDS 100 SQ. INCH.) ON ALL SIDES TOP AND BOTTOM OF BOX. cn z O WIRE A.I.C.: TO MATCH EXISTING FED FROM: METER CENTER E 1 BACK TO BACK ELECT. BOX MOUNTING DETAIL v FOR RATED WALLS NOT TO SCALE ;%•. ��; '�• ke7% i I AREA 0 WORK 120/240v 1 PH 3W /� 1 1 #5 EXISTING LOAD WIREWAY TO TENANTS TO TENANTS _________ __ _- ----- ------------- 1 _ ----------- - ___ -_ --1 HOUSE 1 ' f' - - --'1 PARTIAL EXISTING ELECTRICAL RISER N,T,S, A B ll C �n Sf .� uj r l Ftia V Y.; .,r rx f >4� s r �4 W 1"r1 ry rte - U W) 4 0"_ !,4 w r, NEW Panel Name: A Project #: 150201 Q C`7 MANUFACTURER: SquareD or Equal %M _w INTERIOR MODIFICATIONS � ONLY (ANY EXTERIOR NIODIFICATION NIAY REQUIRE ' A BOARD APPEARANCE) 7 PHASE MAIN LUGS: 100 AMPS '�• ke7% i I AREA 0 WORK 120/240v 1 PH 3W /� 1 1 #5 EXISTING LOAD WIREWAY TO TENANTS TO TENANTS _________ __ _- ----- ------------- 1 _ ----------- - ___ -_ --1 HOUSE 1 ' f' - - --'1 PARTIAL EXISTING ELECTRICAL RISER N,T,S, A B ll C �n Sf .� uj r l Ftia V Y.; .,r rx f >4� s r �4 W 1"r1 ry rte - U W) 4 0"_ !,4 w r, NEW Panel Name: A Project #: 150201 Q C`7 MANUFACTURER: SquareD or Equal LOCATION: BACK OF HOUSE 1 PHASE MAIN LUGS: 100 AMPS 3 cn z O WIRE A.I.C.: TO MATCH EXISTING FED FROM: METER CENTER DISCONNECT 120/240V VOLTAGE MOUNTING: RECESSED ENCLOSURE: NEMA 1 AA 26oO2514 - IB 26o01404 1141 SE 6th TERRACE SUITE i FT. LAUDERDALE, FL 33316 Phone (754) 300 -7770 bbuEock @sustainable - logic.net F"ry i W ° CKT C O BRANCH CRCUrr BREAKER LOADIPNASE URCUfBREAKER BRANCH C O IDENTIFICATION CKT N o rT� V1 IDENTIFICATION FEEDER L ° w 17 � . �� MO --•ao q�&" ® �mM FEEDER o mw w Cr ua w o J 0 i � 2 LU <, Lu W z w E NO. 07 z D PROJECF NO. DRAWN BY 15 -008 t BIB ELECTRICAL GENERAL NOTES, SYMBOLS AND DETAILS, RISER, SCHEDULES EO. 1 D No, E E WRE GIRD, CONIXJrr TRIP POLES KVA A C KVA TRIP POLES WIRE GRID, CONDUT s E E s 1 LIGHTING L 12 12 1/2" 20 1 0,80 t4 0.40 30 2 10 10 3/4" M PKU -1 (FAN -only; COND.- non - conc.) 2 1,2 3 LIGHTING L 12 12 1/2" 20 1 0,80 0.40 M 4 3 5 SIGNAGE L 12 12 1/2" 20 1 1.20 A 1.00 20 1 12 12 1/2" R GENERAL RECEPTACLE 6 3 7 ABOVE SHOW WINDOW L 12 12 112" 20 1 1.20 C.,:;:;.,, 1,00 20 1 12 12 1/2" R GENERAL RECEPTACLE 8 9 BATHRM /B.O.H. LTS L 12 12 1/2" 20 1 0.80 A 1.00 20 1 12 12 1/2" R POS 10 11 O 2.4 C 0.50 20 1 12 12 1/2" R TBB RECEPTACLE 12 2 TWH -1 12 12 314" 20 2 13 O 2.4 0.80 20 1 12 12 1/2" R DRINKING FOUNTAIN GFI 14 15 CASE LIGHTS L 12 12 112" 20 1 0.80 >~... 0.50 20 1 S SPARE 16 17 CASE LIGHTS L 12 12 1/2" 20 1 0.80 2.50 30 2 10 10 3/4" M PKU -1 (HEATER 5kw) 1$ 1,2 SPACE 19 C. .:. 2.50 M 20 21 SPACE SPACE 22 23 SPACE SPACE SPACE 24 11.7 10.1 NOTES: _ CONNECTED DEMAND 1. HACR Type Circuit Breaker LOAD LOAD 2. Verify CB Size With Equipment Name Plate LTG./CONTLOAD @125 %(L) 6A 8.0 TOTAL CONNECTED LOAD: 21.8 KVA 3. Lighting Circuits VIATime Clock RECEPTACLES (per NEC) [R] 4 -3 4.3 TOTAL LOAD DEMAND: 23.4 KVA MOTOR @I00°h(M) 5 -8 5.8 TOTAL LOAD DEMAND: 97 AMPS LARGEST MOTOR @125 ° /4LM) 0.0 0.0 KITCHEN @65 %(K) 0.0 0.0 NEW TENANT LOAD WILL NOT IMPACT EXISTING ELECTRICAL SERVICE / METES SPARES (S) 0,5 0.5 OTHER LOAD (0) 4.8 4.8 NON- CONCURRENT LOAD (N) 00 0.0 '�• ke7% i I AREA 0 WORK 120/240v 1 PH 3W /� 1 1 #5 EXISTING LOAD WIREWAY TO TENANTS TO TENANTS _________ __ _- ----- ------------- 1 _ ----------- - ___ -_ --1 HOUSE 1 ' f' - - --'1 PARTIAL EXISTING ELECTRICAL RISER N,T,S, A B ll C �n Sf .� uj r l Ftia V Y.; .,r rx f >4� s r �4 W 1"r1 ry rte - U W) 4 0"_ !,4 w r, Q C`7 w Cn ? cn z O Q, Cn WSTUDIO AA 26oO2514 - IB 26o01404 1141 SE 6th TERRACE SUITE i FT. LAUDERDALE, FL 33316 Phone (754) 300 -7770 bbuEock @sustainable - logic.net F"ry i W I � Tom boo • V1 rT� V1 `M L ° w 17 � . �� MO --•ao q�&" ® �mM o mw w Cr ua w o J 0 i � 2 LU <, Lu W z w / w F p n..oe: z M m a o 07 z /0, 1 V ` PROJECF NO. DRAWN BY 15 -008 t BIB ELECTRICAL GENERAL NOTES, SYMBOLS AND DETAILS, RISER, SCHEDULES EO. 1