Loading...
15-310-004A 11 B 11 C IC z 0 z z H W;li = E- 24 E- Cn Cn oa Es Q 0 Cz rz xw V5 0 CJ2 0 Aw Q �v ww Z C> Az �4 R Cn as z 0 ad WEn 22 o Z O AM 0 UT z C4 n rnrn ON rmq INW—D, a ER System No. HW-D-1052 February 24, 2005 Assembly Rating - 3 Hr L Rating at Ambient - Less than 1 CFM/Lin Ft EXTEND HEADER CHANNrl_ ABOVE- :, L Rating at 400 F - Less than I CFM/Lin Ft TOP JOINT SHALL BE CAULKED OR ADJACENT CEILING. ATTACH TO SHALL BE PER NOTE #6 OR #7 UNDER CONC. SLAB ABOVE, SEE DETAIL FOR Nominal Joint Width - 3-1/2 In. UL DESIGN #404 ON SHEET A-502 ATTACHMENT. Class 11 and III Movement Capabilities - 14 % Compression or Extension ATTACH STEEL RUNNER CHANNEL TO CONC. SLAB ABOVE USING HILTI X-DNI SPACE FURRING CHANNELS @24- O/C 0.145 DIA. X 3 /4" EMBED, (PER ES MAX. AT RIGHT ANGLES TO BAR JOISTS REPORT ER-2388) 2" FROM ENDS AND OR OTHER STRUCTURAL MEMBERS. 24" O/C STAGGERED. SEE NOTE #6. > SADDLE-TIE FURRING CHANNELS TO BAR Cn JOISTS W/ TRIPLE STRAND 18 GA. WIRE 0 AT EACH INTERSECTION. ALLOW 1" CLEAR SEE REFLECTED CEILING PLANS AND FROM ABUTING WALLS AND PARTITIONS. =i can FINISH SCHEDULES FOR DETAILS REFER TO ID-C-01 FOR SPAN LIMITS AND 4 .<4 SOUND BATTS SIZING. 4° 3 -5l8" DEEP GALVANIZED 25 GAUGE STEEL DRYWALL STUDS, AT 16 O.C. SEE REFLECTED CEILING PLANS AND U.N.0; REFER TO SPECIFICATIONS FINISH SCHEDULES FOR DETAILS AA 26oO2514 - III 26001404 11141 SE 6th TERRACE 4 FOR ADDITIONAL DETAILS 1� 4 d 4 5/8" GYPSUM WALLBOARD EACH FACE SOUND BATTS — — — — — — — — — - STEEL RUNNER CHANNEL W/ GALVANIZED STEEL DRYWALL STUDS, — — — — — — — — — - OPTIONAL 2X WOOD BASE STIFFINER AT 16" O.C. U.N.0; REFER TO E .}J o0o SPECIFICATIONS FOR ADDITIONAL T AS REQUIRED FOR BASE MOULDING DETAILS 3C INSTALLATION. WOOD BASE SHALL BE r (3A) TREATED WITH FIRE RETARDANT 5/8" GYPSUM WALLBOARD EACH FACE PROJECT N0. DRAWN BY BASE JOINT SHALL BE CAULKED BIB A=501 4 , .- - F_ OPTIONAL BASE, REFER TO FINISH SCHEDULES OR INTERIOR DESIGN >:< I IL ILI DRAWINGS FOR DETAILS 2 ATTACH STEEL RUNNER CHANNEL TO Tremco Incorporated 4 SECTION AT TOP SECTION AT FLOOR SLAB USING HILT[ X-DNI 0.145 Sealants & Waterproofing Division Integrated Technical Solutions Dept CLOSURE GAP DIA. X 3 }4" EMBED, (PER ES REPORT FLOOR AND ER-2388 2' FROM ENDS AND 24- O/C IL 3735 Green Rd., Beachwood, OH 44122 STAGGERED. SEE NOTE #6 Toll Free: 866-209-7055 CEILINGS WWWAremcofirestop.corn NOTE: FOR WALL HEIGHTS SECTION AT EXCEEDING 10' -0" IN HEIGHTAND NOT 1. Floor Assembly — Min 5-1/2 in. (140 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg1m3) structural concrete. 2. Wall Assembly —Min 5-1/2 in. (140 mm) thick reinforced lightweight or normal weight (100-150 pcfor 1600 -2400 kg/m3) structural concrete. Wall may NOTE: ATTACH RUNNER ENDS AT MORE THAN 20'-0"; PROVIDE CEILINGS also be constructed ofany UL Classified Concrete Blocks*, DOOR FRAMES AND CORNERS WITH FASTENERS 2" FROM ENDS AND 18" See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names ofmanufacturcrs. TWO FASTENERS. DO NOT MITER O/C, OR AS SPECIFIED BY THE STEEL 3. Joint System — Max width of joint (at time of installation of joint system) is 3-1/2 in. (89 mm). The joint system is designed to accommodate a max 14 'Ibejoint RUNNERS AT CORNERS OR STUD MANUFACTURER percent compression or extension from its installed width. system shall consist of the following: A, Forming Material* -- Min 4 pcf (64 kg/m3) mineral wool batt insulation installed in joint opening as a permanent form. Pieces ofbatt cut to min width INTERSECTIONS. of 5 in, (127 mm) and installed edge-first into joint opening, parallel with joint direction, such that ban sections are compressed min 56 percent in thickness and that the compressed batt sections are recessed from both surfaces of the wall as required to accommodate the required thickness of fill material. NOTES: Adjoining lengths of batt to be tightly- butted with butted seams spaced min 36 in. (914 mm) apart along the length of the joint FLBREX INSULATIONS INC — FBX Safing Insulation 1. ADDITIONAL REQUIRIEMENTS FOR GYPSUM BOARD AND INTERIOR STUDS CAN BE FOUND IN THE SPECIFICAITONS. NOTES: ROCK WOOL MANUFACTURING CO -- Delta Board 2. GAVANNEALED METAL STUDS ARE NOT ACCEPTABLE FOR USE ON THIS PROJECT. 1. ADDITIONAL REQUIRIEMENTS FOR GYPSUM BOARD AND INTERIOR STUDS CAN BE FOUND IN THE SPECIFICAITONS. B. Fill, Void or Cavity Material* — Min 1/4 in. (6 mm) thickness of fill material applied within thejoint� flush with exterior side ofwall. 3. GYPSUM BOARD WITH ORIGIN OF MANUFACTURE IN CHINA IS NOT ACCEPTABLE FOR USE ON THIS PROJECT. 2, GAVANNEALED METAL STUDS ARE NOT ACCEPTABLE FOR USE ON THIS PROJECT. TREMCO INC -- Dymeric 240FC C. Fill, Void or Cavity Material* — When Fyrc-Sil or Dymeric 240FC is used, min 1/4 in. (6 mm) thickness of fill material applied within the joint, flush 4. IN SOME CASES, DRYWALL MAY BE REQUIRED ON ONLY ONE SIDE OF THE STUDS, SEE PLANS 3. GYPSUM BOARD WITH ORIGIN OF MANUFACTURE IN CHINA IS NOT ACCEPTABLE FOR USE ON THIS PROJECT. with interior side of wall. When TREMstop Acrylic SP is used, min 1/8 in. (3 mm) (wet) thickness offill material spray or brush applied to completely FOR LOCATIONS. 5. REFER TO TABLE ID-A-011 FOR STUD DEPTH, SPACING REQUIREMENT, AND MAXIMUM HEIGHT. 4. IN SOME CASES, DRYWALL MAYBE REQUIRED ON ONLY ONE SIDE OF THE STUDS, SEE PLANS cover bottom surface of mineral wool and to lap min I in. (25 mm) onto each edge of concrete. TREMCO INC -- Fyre-Sil, TREMstop Acrylic SP or Dymeric 240FC MAXIMUM DEFLECTION SHALL BE LIMITED TO L/240. FOR LOCATIONS. 5. REFER TO TABLE ID-A-01 FOR STUD DEPTH, SPACING REQUIREMENT, AND MAXIMUM HEIGHT. *Bearing the UL Classification Mark 6. FASTRAK PINS OF SAME SIZE MAY BE USED AS AN ALTERNATE TO HILTI X-DNI. MAXIMUM DEFLECTION SHALL BE LIMITED TO 1_1240. TREMCO FIRE-STOP DETAIL TYPICAL INTERIOR PARTITIONS TYPICAL HANGING CEILING DETAIL NOT DRAWN TO SCALE F-TFSD NOT DRAWN TO SCALE ID-A NOT DRAWN TO SCALE ID-C OPTIONAL WALL MOUNT LIGHTING SCONCE (WS) OPTIONAL MIRROR BORDER is MIRROR (MIR) SCHEDULED FINISH ELEC. HAND DRIER (HDRY) At 1' -8" RECESSED TOWEL DISPENSER (TWDSP) 4. (TYP.) OPTIONAL WALL RECESSED SOAP DISPENSER (SDP) SCONCE (WS2) INTERIOR i'VIODIFICATIONS ONLY ADA GRAB RAILS (ADH) (ANY EXTERIOR MODIFICATION MAY REQUIRE WOOD BASE A BOARD APPEARANCE) WOOD OR METAL 4" L BLOCKING AS NECESSARY TOILET PAPER W FOR FASTENING OF BASE DISPENSER (TP) LAVATORY (SINK) AND FAUCET (FAU) TOP OF SCHEDULED All. FLOORING i TOILET (WC), WALL MOUNT SHOWN, r REFER TO SCHEDULES FOR ACTUAL FIXTURE, MAY BE FLOOR MOUNTED I ........ .. !� SUBSTRATE CV IS C? NOTES: r NOTES: 1. WHERE BASE IS INDICATED AS -NONE, BASE IS NOT REQUIRED AND THIS DETAIL SHALL NOT BE USED. 1. REFER TO FIXTURE OR ACCESSORY MANUFACTURERS SPECIFICATIONS TO VERIFY ADA MOUNTING HEIGHTS. 2. LOCATE BLOCKING OR BACKING AS REQUIRED TO SUPPORT GRAB BARS, FIXTURES AND ACCESSORIES AS REQUIRED. WOOD BASE DETAIL TYPICAL MOUNTING HEIGHTS NOT DRAWN TO SCALE ID-WDB NOT DRAWN TO SCALE I1D-TMH A 11 B 11 C IC z 0 z z H W;li = E- 24 E- Cn Cn oa Es Q 0 Cz rz xw V5 0 CJ2 0 Aw Q �v ww Z C> Az �4 R Cn as z 0 ad WEn 22 o Z O AM 0 UT z C4 n rnrn ON rmq INW—D, a ER COO z 0 Cn 8 0 O 0­4 COO =i can 0. 2-STUD010 AA 26oO2514 - III 26001404 11141 SE 6th TERRACE i SUITE i FE. LAUDERDALE, FL 33316 € Phone (754) 300-7770 bbu I Hock@sustainable-logic.net 0 rM4 •� C) b�0 r--4 E .}J ARCHITECI"S SEAL NN BRIAN BbIl h� -ARC ITECfi AR 9I5754 PROJECT N0. DRAWN BY 15-08 BIB A=501