13-1341-027Lo 1. ALL PLUMBING SHALL BE DONE IN ACCORDANCE WITH THE STATE AND LOCAL CODES AND ORDINANCES. 2. PLUMBING CONTRACTOR SHALL PAY ALL FEES FOR PERMITS AND INSPECTION CHARGES REQUIRED. 3. ALL PIPING SHALL BE INSTALLED RECESSED IN FURRING SPACES, CHASES OR PARTITIONS. 4. EXISTING PIPES SERVING AREAS NOT COVER BY THIS CONTRACT BUT IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED UNLESS IS A TEMPORARY INTERRUPTION COORDINATED WITH THE OWNER. 5. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 6. COORDINATE NEW WORK WITH OTHER TRADES. 7. PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCES. 8. PROVIDE SHUTOFF VALVE FOR EACH GROUP OF FIXTURES. 9. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDE TO CONNECT BOTH TYPES OF PIPES. 10. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ROUGH INS WITH EQUIPMENT AND FIXTURE'S MANUFACTURER BEFORE MAKING ANY INSTALLATION. 11. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 12. INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY & PROPERTY DAMAGE FOR THE DURATION OF WORK. 13. VERIFY LOCATION, SIZE, INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVICE ENGINEER OF ANY DISCREPANCIES. 14. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND APPROPRIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. 15. EACH FIXTURE SHALL BE SEPARATELY TRAPPED UNLESS OTHERWISE INDICATED. 16. FURNISH & INSTALL APPROVED AIR CHAMBERS, AT EACH PLUMBING FIXTURE & P.D.I. APPROVED SHOCK ARRESTORS ON MAIN LINES ON RISERS (Z -1700 SERIES). 17. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING.) 18. ALL FIRE RATED FLOOR & WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE & WALL /FLOOR SLEEVES WITH FIRE RATED FOAM, CHASE TECHNOLOGY CORP. - CTC PR -855 OR 3M, CP -25 CAULKING OR 303 PUTTY, TO ACHIEVE SAME RATING AS WALLS OR FLOORS. 19. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES & ALL WATER HAMMER ARRESTERS. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING & MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. 20. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES WHERE USED AS RETURN AIR PLENUMS. 21. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCEABLE DIAGRAM LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNER /OPERATOR. 22. ALL FIXTURES TO HAVE ACCESSIBLE STOP VALVES. 23. ALL PIPING SHALL BE SUPPORTED IN AN APPROVED MANNER FROM BUILDING STRUCTURE. HANGERS FOR COPPER PIPING SHALL BE COPPER OR COPPER PLATED. 24. ALL METALLIC PIPING, FITTINGS AND HANGERS EXPOSED TO CORROSIVE CONDITIONS SHALL HAVE A PROTECTIVE COATING THAT RESIST CORROSION. 25. FASTENING TO SUPPORT HANGERS & SUPPORTS SHALL BE CAST -IRON INSERTS, EXPANSION TYPES OR THROUGH BOLTING ONLY. 26. ALL HOT & COLD WATER PIPES, STORM DRAIN & CONDENSATE PIPING SHALL HAVE IDENTIFICATION AND FLOW DIRECTIONS BANDS. 27. CONTRACTOR SHALL KEEP A SET OF AS -BUILT DRAWINGS ON THE JOB SITE AT ALL TIMES & DELIVER A SET OF UP TO DATE AS- BUILTS TO THE ENGINEER & OWNER AT THE COMPLETION OF THE PROJECT. 28. TEST AT SOIL, WASTE & VENT PIPING WITH A 10' HEAD WATER. IF WATER LEVEL REMAINS UNCHANGED FOR A 2 -HOUR PERIOD WITH SOURCES DISCONNECTED, SYSTEM SHALL BE CONSIDERED TIGHT. 29. APPLY A WATER PRESSURE TEST TO ALL PARTS OF THE WATER SUPPLY SYSTEM BEFORE THE PIPING IS CONCEALED & BEFORE THE FIXTURES & EQUIPMENT ARE CONNECTED. USE A HYDRO- STATIC PRESSURE OF NOT LESS THAN 200 PSIG , APPLIED TO THE SYSTEM FOR A PERIOD OF 2 HOURS. THERE SHALL BE NO LEAKS AT ANY POINT IN THE SYSTEM AT THIS PRESSURE. 30. PIPING MATERIALS SANITARY, GREASE WASTE, STORM AND CONDENSATE DRAINAGE: CAST IRON DRAINAGE PIPE AND FITTINGS: 1. HUB AND SPIGOT: SERVICE WEIGHT CENTRIFUGALLY SPUN CAST IRON, HUB AND SPIGOT, TAR COATED INSIDE AND OUT, ASTM A74. (BELOW GROUND) 2. NO -HUB: SERVICE WEIGHT CENTRIFUGALLY SPUN CAST IRON, NO HUB, TAR COATED INSIDE AND OUT, CISPI 301. (ABOVE GROUND) CAST IRON PIPE JOINT: A. NO HUB: 1. NEOPRENE GASKET: ASTM C564. 2. STAINLESS STEEL CLAMP AND SHIELD ASSEMBLY: 300 SERIES, CISPI 301 -69T. SWEAT PROOFING: SWEAT PROOF HORIZONTAL STORM DRAINAGE PIPING BETWEEN DRAIN AND VERTICAL LEADER RUNNING IN CONDITIONED AIR SPACE OR PLENUMS WITH 1/2" THICK GLASS FIBER SECTIONAL PIPE COVERING WITH FLAME RETARDANT VAPOR BARRIER JACKET. COPPER TUBING: (2" AND SMALLER) TYPE "K" OR" L ": SEAMLESS HARD DRAWN OR ANNEALED, ASTM B88. TYPE DWV: SEAMLESS HARD DRAWN, ASTM B306. DOMESTIC WATER SUPPLY PIPING: A. ABOVE GROUND: COPPER TUBING TYPE "L" WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS WITH 95/5 SOLDER. 30A. OTHER ACCEPTABLE PIPING MATERIALS SUBSTITUTIONS AS FOLLOW: SANITARY WASTE, CONDENSATE DRAIN & VENT: REFER TO F.B.C.2010, TABLE -702.1 (ABOVE - GROUND), TABLE -702.2 (UNDERGROUND), TABLE -702.3 (BUILDING SEWER) AND 702.4 (PIPE FITTINGS), FOR REQUIRED STANDARDS). (PVC PIPE- SCH -40 IS ACCEPTABLE AS PER OWNER REQUEST) DOMESTIC WATER SUPPLY PIPING: REFER TO F.B.C.2010, TABLE -605.3 AND TABLE -605.4 FOR REQUIRED STANDARDS).(CPVC AND COPPER PIPE - TYPE -M ARE ACCEPTABLE PIPING /FITTING MATERIALS, AS PER OWNER REQUEST) PLUMBING LEGEND SYMBOL DESCRIPTION EXISTING COLD WATER LINE (CW) CONNECTION SCHEDULE NEW COLD WATER LINE (CW) MARK /ITEM# CD NEW CONDENSATE DRAIN LINE CD EXISTING CONDENSATE DRAIN LINE CW FILTERED WATER LINE GREASE WASTE -GW HSK -1 EXISTING GREASE WASTE -GW SINK BOWL IS 10" X 14" X 5 ". EXISTING HOT WATER LINE (HW) NEW HOT WATER LINE (HW) RIGHT AND LEFT ---- -�- --- -�- INDIRECT SAFE WASTE (IW) PR PRESSURE & TEMPERATURE RELIEF LINE PD PAN DRAIN SPLASH EXISTING SANITARY LINE (SAN) DIMENSION OF 2" AND ARE RECTANGULAR IN DESIGN FOR NEW SANITARY WASTE LINE (SAN) EXISTING VENT LINE (V) INCREASED CAPACITY. SANITARY VENT LINE (V) EXISTING PIPE TO BE REMOVED OR ABANDONED. AIR CHAMBER BALANCING VLV. W/ INDICATOR { BALL VALVE CHECK VALVE CONNECT TO EXISTING Q END OF DEMOLITION 1 c_ FD 3 "FLOOR DRAIN `� W/ 1/2- TRAP RESEAL ---+� FCO FLOOR CLEAN OUT -I WCO WALL CLEAN OUT GATE VALVE GAS COCK VALVE �+ HB HOSE BIBB SOLENOID VALVE VALVE IN BOX --® Q RD ROOF DRAIN --- VN GATE VALVE IN VERTICAL y� WHA WATER HAMMER ARRESTOR r-- a "P" TRAP UNION - ---iI� ® FLOOR SINK FULL GRATE (FS) ® FLOOR SINK W/ HALF GRATE (FS) ® FLOOR SINK W/ 3/4 GRATE (FS) ABV. ABOVE BLW BELOW C.B. CATCH BASIN CEIL, CLG. CEILING G.W.H. GAS WATER HEATER FL FLOOR ` F.U. FIXTURE UNIT F.S. FLOOR SINK GD GUTTER DRAIN R.W.L. RAIN WATER LEADER TP TRAP PRIMER (UG) UNDERGROUND V.T.R. VENT THRU ROOF CW COLD WATER PIPE HW HOT WATER PIPE FW FILTERED WATER PIPE FF FINISHED FLOOR WF8 WATER FILTER BOOSTER EWH ELECTRIC WATER HEATER (TANK TYPE) MSK MOP SINK HSK HAND SINK GI GREASE INTERCEPTOR FC FLOW CONTROL GW GREASE WASTE PIPE IW INDIRECT WASTE PIPE S SANITARY PIPE V VENT PIPE 2 WAY F.CO TWO WAYS FLOOR CLEAN -OUT SD STORM DRAINAGE PIPE OSD OVERFLOW DRAINAGE PIPE CD CONDENSATE DRAIN PIPE PLUMBING FIXTURE SCHEDULE (ALL FIXTURES & FAUCETS TO COMPLY WITH MIAMI DADE ORDIANCE 8 -31) CONNECTION SCHEDULE MARK /ITEM# DESIGNATION FIXTURE DESCRIPTION ACCESSORIES WASTE CW HW HSK -1 HANDSINK MANUFACTURER SINK BOWL IS 10" X 14" X 5 ". RIGHT AND LEFT "ADVANCE TABCO" SINK BOWL HAS A LARGE LIBERAL RADII WITH A MINIMUM 11/2" 1/2" 1/2" SPLASH MN- 7- PS -EC -SP DIMENSION OF 2" AND ARE RECTANGULAR IN DESIGN FOR INCREASED CAPACITY. 7 3/4" HIGH SIDE SPLASHES. STAINLESS STEEL 1-1/2- BASKET DRAIN. 1-1/2" IPS. WALL MOUNT BRACKET. 4" O.C. ECONOMY SPLASH MOUNTED GOOSENECK FAUCET, CHROME PLATED & FURNISHED WITH AERATOR. JSK -1 JANITOR SINK MANUFACTURER "AERO." AFRO FLOOR - MOUNTED STAINLESS STEEL MOP SINK 21 X 15 AE -XMP -2116 X12MOP SINK SERVICE FAUCET (T &S), MODEL S -70 2" 1/2" 1/2" 3CSK -1 THREE COMPARTMENT MANUFACTURER 123" X 24" X 30" (3) COMPARTMENT SINK SINK "STAINLESS STEEL" BOWLS 18" X 18" X 14 ", (2) 18" DRAIN BOARDS 2" 1/2" 1/2" MN- MF3- 2424 -24LR (3) TWIST HANDLE LEVER DRAINS, INDIRECT T &S PRERINSE WALL MOUNT UNIT WITH ADD -A- FAUCET 12" SPOUT. 3CSK -2 THREE COMPARTMENT MANUFACTURER 100.25" X 30" X 35" (3) COMPARTMENT SINK SINK "STAINLESS STEEL" BOWLS 18" X 18" X 14 ", (2) 18" DRAIN BOARDS 2" 1/2" 1/2" MN -3F3- 2424 -24L (3) TWIST HANDLE LEVER DRAINS, INDIRECT T &S PRERINSE WALL MOUNT UNIT WITH ADD -A- FAUCET 12" SPOUT. PSK -1 PREP -SINK MANUFACTURER "STAINLESS 3F1 L DELUXE SERIES, NSF SINKS, ONE COMPARTMENT, ", 2" 1/2- 1/2" STEEL" LEFT DRAINBOARD. BOWLS 24" X 24" X 30 MATERIAL 3F - MN -3171- 2424 -24L 16 GAUGE 304 STAINLESS STEEL. INDIRECT WC -1 WALL -HUNG TOILET "AMERICAN STANDARD" AFWALLO FloWise@ ADA RETROFIT ELONGATED FLUSHOMETER FLUSH VALVE. NO. 2296.019EC TOILET VITREOUS CHINA WITH EVERCLEAN® 3" 1/2" OR APPROVED EQUAL. CLOSET CARRIER "JOSAM" No. 16123 LAV -1 HANDICAPPED "AMERICAN STANDARD" WITH CONTOURED SIDE AND BACK SPLASH SHIELDS, 4" 1 1/4" 1/2" 1/2" LAVATORY NO. 0355.012 PUNCHING, 20 x 18 VITREOUS CHINA; FURNISH OFFSET GRID "LUCERNE" LAVATORY DRAIN 7723.018 AND TAIL PIECE. FURNISH SYMMONS -SCOT OR APPROVED EQUAL. S- 20 -FR, 4" CENTER SET FAUCET , 0.5 GPM FLOW WITH ROSE SPRAY OUTLET. MOUNT AT ADA HEIGHT. UR -1 WALL -HUNG URINAL "AMERICAN STANDARD" 0.5 GPF EXPOSED TOP SPUDURINAL AND FLUSH VALVE. NO. 6590.505 SELECTRONIC@ URINAL FLUSH VALVECLOSET 2" 1/2" OR APPROVED EQUAL. CARRIER "JOSAM" NO. 16123 FCO FLOOR CLEANOUT "ZURN" Z -1400 FLOOR CLEANOUT ADJUSTABLE HEAVY DUTY CAST IRON W /NICKEL 3" OR 4" -- OR APPROVED EQUAL. BRONZE TOP. TP -1 TRAP PRIMER "JAY R.SMITH ", PRIME -EZE WATER SAVER TRAP PRIMER SATIN CHROME PLATED -- 1/2" -- (AUTOMATIC) 2698 -ADA OR CAST BRONZE P- TRAPWITH GROUND JOINT CONNECTION, APPROVED EQUAL.. THREADED WALL TUBE, SLIP JOINT NUTS, WASHERS ANDESCUTCHEONS, 1/2" (13) PRIMER TUBE WITH COMPRESSION FITTING CONNECTION AT WALL TP -2 TRAP PRIMER "ZURN" Z1022 SANI -GARD AUTOMATIC TRAP PRIMER, ALL BRONZE BODY WITH -- 1/2" (AUTOMATIC) OR APPROVED EQUAL. INTEGRAL VACUUM BREAKER, NON -LIMING INTERNAL OPERATING ASSEMBLY WITH,GASKETED BRONZE COVER. PLUMBING DRAINAGE DESIGNATION FIXTURE DESCRIPTION ACCESSORIES MAXIMUM CONNECTION SCHEDULE WASTE CW HW FLOW RATE FS -1 FLOOR SINK FOR "ZURN INDUSTRIES." HEAVY DUTY FLOOR DRAIN 12" SQUARE WITH INDIRECT WASTE MN -ZN 1900 COATED CAST -IRON BODY ___ 3" - _ GRATE AND SLOTTED SEDIMENT BUCKET FD // FLOOR DRAIN "ZURN INDUSTRIES." HEAVY DUTY ENAMELED CAST IRON FLOOR DRAIN -11 FD_2. (GENERAL PURPOSES) MN- ZN- 415 -6 -P W /6" ROUND NICKEL BRONZE STRAINER, TRAP --- 2 "/3" - - PRIMER CONNECTION. FURNISH DRAINS IN MECHANICAL ROOMS WITH CONE OVAL SHAPED FUNNEL GAS TANKLESS WATER HEATER DESIGNATION FIXTURE DESCRIPTION DESCRIPTION MAXIMUM CONNECTION SCHEDULE WASTE CW HW FLOW RATE 1GWH -1 GAS TANKLESS "RINAL" REFER TO GAS EQUIPMENT SCHEDULE WATER HEATER MN- REU- VC2025FFU -US - -- - 3/4" 3/4" NOTE: -ALL FIXTURE AND FAUCETS SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2010- PLUMBING, TABLE 604.4 (WATER CONSERVATION REQUIREMENTS). -ALL WALL HANG PLUMBING FIXTURES SHALL COMPLY WITH F.B.C. 2517.5.1.1 -ANTI -SCALD VALVE: ALL SHOWERS & BATH /SHOWER COMBINATIONS SHALL BE PROTECTED WITH A CONTROL VALVE OF THE PRESSURE BALANCE, THERMOSTATIC MIXING OR COMBINATION TYPE SET. HANDLE POSITION STOPS PER MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120" F. TABLE-604.412010 FBC (PLUMBING) MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS PLUMBING FIXTURE OR FIXTURE FITTING LAVATORY, PRIVATE LAVATORY, PUBLIC, (METERING) LAVATORY, PUBLIC (OTHER THAN METERING) SHOWER HEAD A SINK FAUCET URINAL WATER CLOSET MAXIMUM FLOW RATE OR QUANTITY *B 2.2 GPM AT 60 PSI 0.25 GALLON PER METERING CYCLE 0.5 GPM AT PSI 2.5 GPM AT 80 PSI 2.2 GPM AT 60 PSI 1.0 GALLONS PER FLUSHING CYCLE 1.6 GALLONS PER FLUSHING CYCLE m