13-1341-016GENERAL ELECTRICAL NOTES & SPECIFICATIONS t. THE "GENERAL. CONDITIONS OF THE CONTRACT ", CURRENT EDITION, PUBLISHED IN STANDARD FORM BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL BE PART OF THIS CONTRACT. 2. IT IS NOT THE INTENT OF THESE PLANS AND SPECIFICATIONS TO SHOW EVERY AND ALL DETAILS OF CONSTRUCTION. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE ELECTRICAL INSTALLATION IN PROPER WORKING ORDER. 3. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING CODE AND THE LATEST STATE AND LOCAL. CODES THAT APPLY. 4. THE CONTRACTOR SHALL TAKE OUT PERMITS, PROCURE CERTIFICATES AND PAY ALL FEES CONNECTED WITH HIS WORK. 5. BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS SURROUNDING THE WORK. IT SHALL BE THE RESPONSIBILITY OF THE BIDDERS TO VISIT THE SITE OF WORK AND ACQUAINT THEMSELVES WITH ALL AVAILABLE INFORMATION REGARDING THE EXISTING FACILITIES. FAILURE OF THE BIDDERS TO SO INFORM THEMSELVES OF EXISTING CONDITIONS AND TO INCLUDE IN THEIR PROPOSALS A SUM SUFFICIENT TO COVER SAME WILL NOT ENTITLE THEM TO AN EXTRA. 6. THE CONTRACTOR IS REFERRED TO THE ARCHITECTURAL PLANS AND SPECIFICATIONS. SUCH PLANS AND SPECIFICATIONS ARE CONTRACT DOCUMENTS. 7. DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCATIONS OF ALL ELECTRICAL ITEMS. EXACT CONDUIT ROUTING SHALL BE DETERMINED IN THE FIELD, UNLESS OTHERWISE NOTED (UQN). 8. CONTRACTOR SHALL SUBMIT REQUESTS FOR SUBSTITUTION IN WRITING TO THE ENGINEER, 10 WORKING DAYS PRIOR TO BIDDING DATE. 9. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL FOR ALL EQUIPMENT AND MATERIALS. SUBMIT A MINIMUM OF FOUR SETS TO THE A /E. 10. THIS CONTRACTOR SHALL TOUCH UP OR REFINISH THE FACTORY FINISH OF EQUIPMENT MARRED DURING DURING SHIPMENT OR INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR TO ORIGINAL CONDITIONS ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT, AND FURNISHING CAUSED DURING THE PERFORMANCE OF WORK. 11. THE ELECTRICAL. INSTALLATION SHALL MEET THE APPROVAL OF THE ENGINEER BEFORE ACCEPTANCE BY THE OWNER. 12. THE CONTRACTOR SHALL BE A STATE LICENSED CONTRACTOR. 13. THE ENTIRE INSTALLATION SHALL BE PERFORMED UNDER DIRECT SUPERVISION OF A LICENSED MASTER ELECTRICIAN IN A FIRST CLASS WORKMANLIKE MANNER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS SHOWN AND /OR NOTED ON THE DRAWINGS. 14. ELECTRICAL. WORK SHALL NOT INTERFERE WITH CLEARANCES REQUIRED FOR GENERAL AND MECHANICAL CONSTRUCTION. SHOULD ELECTRICAL WORK BE INSTALLED WHICH INTERFERES WITH THE WORK OF OTHER TRADES, SUCH WORK SHALL BE CORRECTED AT NO COST TO THE OWNER. THE CONTRACTOR SHALL SUBMIT (4 COPIES) EQUIPMENT LAYOUT OF ALL ELECTRICAL SPACES, ROOMS, ETC., TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING EQUIPMENT OR INSTALLING CONDUITS, ETC., LAYOUTS SHALL CONSIST OF PLAN VIEWS (SCALED AT 1/2" = 1' -0 ") AND ELEVATIONS (DIMENSIONED) FOR EACH SPACE, ROOM, ETC., AND SHALL INCLUDED EQUIPMENT FURNISHED BY OTHER TRADES. 15. GROUNDING SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (ARTICLE 250) AND REQUIREMENTS OF THE INSPECTING AUTHORITY. ALL CONNECTIONS TO GROUND RODS SHALL BE MADE WITH UL APPROVED ACCESSIBLE GROUND CLAMPS, UNLESS OTHERWISE NOTED. 16. UPON COMPLETION OF WORK, THIS CONTRACTOR SHALL REMOVE ALL RUBBISH CAUSED BY HIS WORK AND SHALL THOROUGHLY CLEAN ALL ELECTRICAL EQUIPMENT. 17. ALL WORK SHALL BE GUARANTEED FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. 18. ALL ITEMS OF ELECTRICAL. EQUIPMENT ASSOCIATED WITH THE CONTROL OF ELECTRICAL CIRCUITS AND APPARATUS SHALL BE IDENTIFIED. 19. ALL POWER AND LIGHTING CIRCUIT WIRING SHALL BE COLOR CODED AS FOLLOWS: 120Z20$y, PHASE "A" - BLACK PHASE "B" - RED PHASE "C" - BLUE NEUTRAL - WHITE GROUND - GREEN 20. ALL CONDUCTORS SHALL BE COPPER, 60OV. 110 AND SMALLER, SOLID TYPE THWN /THHN; #8 AND LARGER, STRANDED TYPE THWN /THHN. 21. ALL CONDUCTORS FOR POWER LIMITED CABLES SHALL COMPLY WITH ARTICLES 725 & 760 OF N.E.C. LATEST EDITION. 22. NOMINAL MOUNTING HEIGHT OF DEVICES IN EXPOSED CONCRETE BLOCK, TILE OR BRICK WALLS SHALL ALL OCCUR WITHIN A STRUCTURAL COURSE. A MIN. AMOUNT OF BLOCK, TILE OR BRICK WALLS SHALL BE CUT. 23. ALL ELECTRICAL. EQUIPMENT AND DEVICES SHALL BE INDUSTRIAL GRADE, HEAVY -DUTY, AND U.L. LISTED UNLESS SPECIFIED OTHERWISE. ALL ELECTRICAL EQUIPMENT, DEVICES, WIRE, ETC., SHALL BE LISTED, FOR THE INTENDED USE, WITH UNDERWRITER'S LABORATORIES INC. (UL), WHERE STANDARDS HAVE BEEN ESTABLISHED BY UL. AS A MINIMUM, ALL EQUIPMENT SHALL MEET APPLICABLE STANDARDS, FOR THE TYPE OF EQUIPMENT AND THE INTENDED USE, OF THE FOLLOWING. A AMERICAN NATIONAL. STANDARDS INSTITUTE (ANSI) B. ILLUMINATING ENGINEERS SOCIETY (IES) C. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) D. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) NOTE: THESE STANDARDS ARE SUBORDINATE TO STANDARDS SET BY U.L. AND LOCAL CODES. 24. WIRING DEVICES SHALL BE SPECIFICATION GRADE. MINIMUM SIZE OF OUTLET BOXES SHALL BE 4" SO. TRADE. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURE FOR OTHER CLASSIFIED AREAS. 25 OR ELECTRICAL ED STEELS( GS) EXCEPT THAT: (A) POLYOVINYLSCHLOR DE (PVC)RCONDU TS IMAY BE USED IN CONCRETE SLABS AND UNDERGROUND PROVIDED THAT ELBOWS AND RISERS ARE RGS; (B) ELECTRICAL METALLIC TUBING (EMT) MAY BE USED IN WALLS OR CEILINGS OF FINISHED AREAS WHERE NOT SUBJECT TO MECHANICAL DAMAGE, OR CORROSIVE CONDITIONS; (C) LIQUID TIGHT FLEXIBLE CONDUIT WHERE REQUIRED IN WET OR DAMP LOCATIONS; (D) FLEXIBLE METALLIC CONDUIT WHERE REQUIRED IN DRY LOCATIONS. ALL CONDUITS IN HAZARDOUS LOCATIONS SHALL MEET THE REQUIREMENTS OF NEC CHAPTER 5. THE USE OF ENT CONDUIT IS PROHIBITED. 26. APPLY 2 COATS OF BITUMASTIC COATING TO ALL METALLIC CONDUITS INSTALLED UNDERGROUND. 27. NO CONDUITS TO BE RUN IN DUCT WORK. A POLYESTER PULL CORD SHALL BE INSTALLED IN ALL EMPTY CONDUITS. 28. SIZE ALL WIREWAYS ACCORDING TO N.E.C. ARTICLE 376 AND 378 29. ALL RATED WALL /FLOOR PENETRATIONS ARE TO BE SEALED WITH A FIRE RATED SEALER, PER ASTM E814. 30. WHERE CORE DRILLING OF FLOORS /WALLS IS REQUIRED, CONTRACTOR SHALL SEAL OPENINGS AFTER UTILITIES HAVE BEEN INSTALLED. LOCATION OF CORED HOLES SHALL COORDINATE WITH LOCATION OF EQUIPMENT IN A MANNER TO BE CLEAN AND FUNCTIONAL. THE CONTRACTOR SHALL INSTALL ONLY ONE CONDUIT PER HOLE AND SEAL AROUND THE OPENING AS SPECIFIED ABOVE. 31. ANY VARIATION FROM THE PLANS ARE TO BE PREVIOUSLY APPROVED BY THE ENGINEER IN WRITING. 32. CONDUIT AND ELECTRICAL EQUIPMENT EXPOSED TO WEATHER MUST BE WEATHERPROOF (NEMA 3R). 33. FUSES SHALL BE BUSSMAN "FUSETRON" DUAL - ELEMENT FUSES FOR BRANCH CIRCUIT PROTECTION AND ALSO FOR MOTOR RUNNING PROTECTION IF REQUIRED, OR FUSES AS CALLED FOR ON DRAWINGS. 34. TERMINATIONS ARE TO BE MADE AS PER U.L. ARTICLE 486B. 35. THE GENERAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL SITE WORK. 36. ALL CIRCUIT BREAKERS SHALL BE INVERSE TIME TYPE (THERMAL MAGNETIC). MULTI -POLE CIRCUIT BREAKERS SHALL BE COMMON TRIP. NO TIE HANDLES PERMITTED. 37. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR THE ADVANCED ORDERING OF LONG LEAD ITEMS, AS NOT TO INTERFERE WITH THE PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. 38. THE CONTRACTOR SHALL VERIFY CIRCUIT DEVICE PROTECTIVE RATING FOR EQUIPMENT PRIOR TO CONSTRUCTION. 39. USE 3/4" EXTERIOR GRADE PLYWOOD BACKBOARDS FOR SURFACE MOUNTING GROUPED EQUIPMENT, PAINTED ON BOTH SIDES AND EDGES WITH TWO COATS OF NAVAL GRAY PAINT (FIRE RESISTANT). 40. NO CUTTING OR DRILLING OF STRUCTURAL ITEMS SHALL BE DONE WITHOUT PRIOR WRITTEN APPROVAL FROM A LICENSED STRUCURAL ENGINEER. NOTES ELECTRICAL LEGEND, AND DETAILS ELECTRICAL SYMBOL LEGEND LIGHTING FIXTURE (SEE LIGHTING FIXTURE SCHEDULE ALSO) 150c, CEILING LIGHT FIXTURE - UPPER CASE LETTER DESIGNATES FIXTURE TYPE, LOWER CASE LETTER DESIGNATES SWITCHING. C9 EXIT SIGN (LIGHT FIXTURE) CEILING MOUNTED DOUBLE SIDED SIGN- CONNECTED TO LIGHTING CIRCUIT. ROWS INDICATE DIRECTIONS. PROVIDE WITH BATTERY PACK. t__P EILING MOUNTED EXIT SIGN FIXTURE (UNLESS OTHERWISE NOTED) ° LED LIGHT FIXTURE (NORMAL POWER CKT.) LED EMERGENCY LIGHT FIXTURE CONNECTED TO EMERGENCY LIGHTING CIRCUIT AND WITH BATTERY PACK FOR MINIMUM OF 1200 LUMENS PER FIXTURE WHEN OPERATED ON BATTERY. DUAL HEAD EMERGENCY STAND -BY LIGHT, WITH BATTERY PACK, WALL MOUNTED. MT. UP 7 -6" A.F.F. TO CL OF OUTLET BOX. ® DUAL HEAD EMERGENCY STAND -BY LIGHT, WITH BATTERY PACK, CEILING MOUNTED 0M) WALL MOUNTED ELEVATOR PIT LIGHT FIXTURE. (VAPOR TIGHT) ON EMERGENCY KT. MT. MID -WAY BETWEEN PIT BOTTOM AND FLOOR LINE ABOVE. Q PENDANT LIGHT AS SHOWN -SEE FIXTURE SCHEDULE ISURFACE /PENDENT MOUNTED INDUSTRIAL STRIP FLUORESCENT FIXTURE SEE PLAN FOR MOUNTING HGT. OF PENDENT FIXTURE. Q DOWNLIGHT-TYPE AS SHOWN -SEE FIXTURE SCHEDULE FQ -T WALL MOUNTED LIGHT -TYPE AS SHOWN -SEE FIXTURE SCHEDULE CEILING MOUNTED OCCUPANCY SENSOR. MODEL LOS -CDT SERIES OR EQUIVALENT. WIRE AS PER MANUFACTURER SPECS TOGGLE SWITCHES (SPECIFICATION GRADE - IVORY COLOR) ga SINGLE Pq�E TOGGLE SWITCH, 20 AMP, 120/277V. SPECIFICATION GRADE. LETTER DENOTES LIGHTS ON SWITCH 'A. MOUNT AT 48" A.F.F. TO q. OFF OUTLET BOX UNLESS NOTED. 2 TWO POLE TOGGLE §VTCH 20 AMP 120 -/27N. SPECIFICATION GRADE LETTER DENOTES LIGHTS ON SWITCH A . MOUNT AT 46" A.F.F. TO CL OF OUTLET BOX UNLESS NOTED. 3 �► THREE WAY SWITCH , 20 AMP, 1 ;0 27N., SPECIFICATION GRADE LETTER DENOTES LIGHTS SWITCHED. MOUNT AT 48 F.F. TO CL OUTLET BOX UNLESS NOTED. 4 % FOUR WAY SWITCH , 20 AMP, 170 277V., SPECIFICATION GRADE LETTER DENOTES LIGHTS SWITCHED. MOUNT AT 48 0 C OF OUTLET BOX A.F.F. UNLESS NOTED. So OCCUPANCY/VACANCY SENSOR SWITCH MSOPS2 OR EQUIVALENT. & SINGLE POLE SWITCH AND PILOT LIGHT. (PILOT LT. "ON" WHEN EQUIPMENT IS OPERATING.) gN, MOTOR RATED TOGGLE SWITCH WITH OVERLOAD PROTECTION KEY SWITCH, MOUNT AS DIRECTED ON PLAN. To DIMMER SWITCH. TYPE SEE SPECIFICATION -MT. AS DIRECTED ON PLAN. RECEPTACLES (SPECIFICATION GRADE - IVORY COLOR) DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. MOUNTED 18" A.F.F. TO CL OF OUTLET BOX. (EXCEPT AS NOTED). HUBBELL 52621 U.O.N. p0 DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. VERIFY MOUNTING HEIGHT. HUBBELL 52621 U.O.N. �@ DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. SWITCHED AS PER PLAN. co QUADUPLEX RECEPTACLE 20 A., 120 V., GROUNDING TYPE. MOUNTED 18" A.F.F.. HUBBELL 4151 U.O.N. F9 SINGLE RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. MOUNTED 18" A.F.F. TO J OF OUTLET BOX. F* DUPLEX RECEPTACLE MOUNTED HORIZONTALLY; 20 A.,120 V.,GROUNDING TYPE. MOUNTED AS NOTED ON PLANS (EXCEPT AS NOTED). DUPLEX GFI RECEPTACLE MOUNTED HORIZONTALLY; 20 A.,120 V.,GROUNDING TYPI. MOUNTED UP AS NOTED ON PLANS. EXCEPT IN RESTROOMS NEXT TO SINKS WHERE IT SHALL BE MOUNTED A 42" A.F.F. TO C OF OUTLE , F0 DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. MOUNTED 18" A.F.F. TO C OF OUTLET BOX. (EXCEPT AS NOTED). CONNECTED THRU EMERGENCY PANEL. (AN CEILING MOUNTED OUTLET BOX FLUSH WITH TILE. F-00 DRYER RECEPTACLE. MT. UP 42" TO � OF OUTLET BOX. � � DENOTES FLOOR OR ROOF MOUNT `% DENOTES CEILING MOUNT TELEPHONE SYSTEM TELEPHONE /DATA OUTLET 4- 11/16" X 4- 11/16" 2 -1/8" WITH BUSHED HOLE COVER PLATE- MOUNTED 18" A.F.F. TO C OF OUTLET(EXCEPT AS NOTED) PROVIDED 3/4" E.C. FROM EACH OUTLET TO PHONE (LOCAL) PULL BOX IN CL'G SPACE (EXCEPT AS NOTED.) TELEPHONE ROOM. CONDUITS �-` ARROW DESIGNATES "HOMERUN" TO PANEL,HASH MARKS DESIGNATE NUMBER OF WIRES. 3t INDICATES GREEN BOND WIRE - - - - -- INDICATES CONDUIT RUN EXPOSED. POWER DISTRIBUTION C9 VARIBLE FREO. DRIVE WITH LINE SIDE BRAKER FURNISHED BY DIV. 15 MT'D AND CONNECTED BY DIV. 16 t__P SAFETY SWITCH - HEAVY DUTY NEMA CLASS "A" IN NEMA 1 ENCLOSURE, OUTDOOR TYPE NEMA 3R. 3 220a DESIGNATES SWITCH RATING, "3" DESIGNATES POLES; "20" TIME DELAY FUSE; "30 "SWITCH AMPS. Ful MOTOR CONTROLLER FURNISHED BY DIV.15, INSTALLED AND CONNECTED BY DIV. 16 CONTRACTOR. MOTOR. (FURNISHED BY ARCH. DIV. 13, OR 15 CONNECTED BY DIV 16. OR ELEV./ESC. INSTALLER) ® T,20/208V., 30, 4W. PANEL BOARD. JUNCTION BOXES JD EQUIPMENT JUNCTION BOX, FURNISHED WITH EQUIPMENT. a�O WALL CEILING MOUNTED JUNCTION BOX. MINIMUM 4" X 4" X 1 1/2" WITH BLANK PLATE. MT. WALL BOX UP AS SHOWN ON PLAN. Vos WALL /CEILING MOUNTED J.BOX FOR SIGNAGE. MT. WALL BOX UP AS SHOWN ON PLAN. GENERAL ELECTRICAL NOTES - ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCES AND ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. - SUBMIT SHOP DRAWINGS FOR ACCEPTANCE BY THE ARCHITECT AND /OR ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF THE EQUIPMENT AND MATERIALS. NO FACSIMILES OR FACSIMILE COPIES SHALL BE ACCEPTED. - ALL CONDUCTORS SHALL BE THW OR THWN COPPER. ALL EXPOSED CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE. P.V.C. CONDUIT SHALL ONLY BE USED IN SLAB OR UNDERGROUND AT A MINIMUM DEPTH OF 24 INCHES. - ALL DEDICATED OUTLETS SERVING EQUIPMENT SUCH AS REFRIGERATORS, WATER COOLERS, COPIERS, FAXES, ETC. SHALL HAVE SEPARATE NEUTRAL CONDUCTORS TO EACH DEVICE OR APPLIANCE. - FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL VIBRATING EQUIPMENT SUCH AS MOTORS, ETC. - ALL WIRING DEVICES SHALL BE LEVITON COMMERCIAL GRADE OR EQUAL AS APPROVED BY ARCHITECT OR ENGINEER. - ALL RECEPTACLES SHALL BE INSTALLED AT 18" A.F.F. UNLESS OTHERWISE NOTED. - ELECTRICAL POWER AND CONTROL WIRING FOR H.V.A.C. AND MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. - ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEMS FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENTS OF THE FIXTURE. - ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THE ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES, SWITCHES AND EQUIPMENT FOR EXACT LOCATION. - ALL ELECTRICAL EQUIPMENT SHALL BE APPROVED AS SAFE FOR USE IN THE U.S. WORKPLACE, AS PER A "NRTL" RECOGNIZED ORGANIZATION. (U.L., C.S.A., ETC.) - ALL BRANCH CIRCUITS SHALL BE SIZED IN ACCORDANCE WITH N.E.C. 210 -19 REGARDLESS OF SIZES SHOWN ON PLANS OR PANEL SCHEDULES. PROVIDE EXPANSION JOINTS WHERE REQUIRED AS PER N.E.C. 300 -7(b). LIGHTING FIXTURE SCHEDULE NOTES: 1. ALL LIGHT FIXTURES SPECIFIED ABOVE, COULD BE SUBSTITUTED WITH LIGHT - FIXTURES OF EQUAL QUALITY PREVOIUSLY APPROVED BY THE ENGINEER OF RECORD. 2. MOUNTING HEIGHT FOR EXIT -SIGNS SHALL BE AS FOLLOWS: WALL - MOUNTED IN OFFICE 6" ABOVE THE DOOR. PENDANT MOUNTED IN CORRIDOR (OFFICE) 7' -6" A.F.F. 3. CONTRACTOR SHALL ORDER ALL LIGHT- FIXTURES WITH THE REQUIRED HARDWARE FOR A COMPLETE INSTALLATION. THIS INCLUDES WIRING WHIP, FUSES, ETC. 4. EMERGENCY BATTERY LIGHT SHALL BE CONNECTED TO THE SAME BRANCH CIRCUIT FEEDING THE NORMAL LIGHTS IN THE AREA AND AHEAD OF ANY LOCAL SWITCH. 5. ALL FIXTURES PROVIDED WITH BATTERY PACKS SHALL BE ABLE TO PROVIDE A MINIMUM OF 80% OF TOTAL FIXTURE LUMEN OUTPUT FOR 1.5 HOURS MINIMUM 1 or 2 Hour Fire Rated SS If/. Through Penetration Firestop Una �a for Single Metal Pine through GYM walls using TREMstop WBM. St WL1051 F- RATING = 1 and 2 Hr. T- RATING = 1 and 2 Hr. F =T 1 3 3 2 2 DRAWING NOT TO SCALE (D 1 OR 2 HOUR FIRE RATED GYPSUM WALLBOARD /STUD WALL ASSEMBLY. 1� STEEL PIPE: 6" DIAMETER (OR SMALLER) SCHEDULE 40 (OR HEAVIER) CONDUIT: 4" STABETER (OR SMALLER) EMT OR RIGID STEEL CIRCULARCOOVIV DIAMETER (OR SMALLER) 26 GAUAGE (OR HEAVIER) GALVANIZED STEEL VENT DUCT. Q TREMstop WBM: FILL MAXIMUM 3/4" ANNULUS WITH A THICKNESS OF 1 1/4" (2 HOUR F- RATING) OR 3/4" (1 HOUR F- RATING). DETAIL -B GYPSUM WALL PENETRATION DETAIL ass °f: �a St CAJ 1144 F- RATING = 1, 2 and 3 Hr. T- RATING = 1, 2 AND 3 Hr. F =T IDRAWING NOT TO SCALE ® FLOOR OR WALL ASSEMBLY = 4" TO 6" THICK CONCRETE. Q STEEL PIPE: 6" DIAMETER (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL. Q Max. Pipe Min. Forming Min. Fill F T Diameter Matt. Thkns Matt. Thkns Rating Rating (inches) (inches) (inches) (Hour) (Hour) 6 4 0.5 1 0 4 3.5 1 2 0.5 6 1.25 2.375 3 0 x ANNULAR SPACE IS 3/4` A. 4.0 pcf MINIMUM DENSITY MINERAL WOOL INSULATION, 5RI(WMMUFATTq&- THICKNESS OF TREMstop WBM. N❑TE: FOR WALLS APPLY TREMstop WBM TO BOTH SURFACES OF WALL. DETAIL -A CONCRETE WALL OR SLAB PENETRATION DETAIL ISSUE DATE: 12.05.13 PERMIT SET No. I DATE TI ESCalPT116N All ideas, designs, arrangements, plans and specifications indicated or represented by this drawing are owned by and are the property of Borges +Associates, P.A., and were created, evolved and developed for use on and in connection with the specified project, No copies, transmissions, reproductions, or electronic manipulation of any portion of these drawings in whole or in part are to be made without the express written permission of Borges +Associates, P.A. All copyrights reserved © 2005 bor ges+ associates architecture urban - planning interior - design 200 S. Biscayne Blvd., Suite 800 ■ Miami, Florida 33131 305.374.9216 phone ■ 305.374.9217 fax Project Team :A) a 4 .xgam IfY1{'° t /j���. /�•. t / � v M.E. Engineering Consultants, Inc. Ph:(305 )9054652 CA 29121 R I C E HOUSE OF KABOB -SOUTH MIAMI 5818 SOUTH DIXIE HIGHWAY Miami, FL 33143 Project Number 130220 Drawing Name ELECTRICAL LEGEND, NOTES AND DETAILS Drawing Number AS SHOWN I E-000