12-732-007TO CITY SEWER u u EXISTING GREASE INTERCEPTOR FROM PREVIOUS RESTAURANT TENANT. CURRENTLY NOT BEING UTILIZED EXISTING PLUMBING PLAN SCALE= 1/4"= P-0-' 2WAY C.O. TO CITY SEWER / 0 0 1 EXISTING GREASE INTERCEPTOR FROM PREVIOUS RESTAURANT TENANT. CURRENTLY NOT BEING UTILIZED PROP05ED PLUMBING PLAN SCALE= 1/4"= P -0" GENERAL PLUMBING NOTES I . ALL WORK REFLECTED ON THESE DOCUMENTS ARE IN COMPLIANCE WITH THE 2010 EDITION OF THE "FLORIDA BUILDING CODE - PLUMBING. 2. THE NATURE OF THI5 REMODELING TYPE PROJECT POSES SPECIAL UNFORESEEN CONDITIONS TO THE ARCHITECT AS WELL AS THE CONTRACTORS. EVERY EFFORT HAS BEEN MADE TO SHOW AND VERIFY THE LOCATION OF EXISTING PLUMBING SYSTEMS WHERE POSSIBLE. THE MAJOR PORTION OF THE PLUMBING SYSTEMS ARE SHOWN ON THESE DRAWINGS. HOWEVER DEVIATION MAY BECOME EVIDENT AND CHANGES MAY OCCUR AS THE JOB PROGRESSES. 3. EXISTING CONDITION DEPICTED ON THESE DRAWINGS WERE ESTABLISHED FROM LIMITED FIELD OBSERVATIONS. AS BUILT DRAWINGS WERE NOT AVAILABLE FOR THIS PROPERTY. CONTRACTORS SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO SUBMITTING THEIR BID AND BRING ALL DISCREPANCIES TO THE ATTENTION OF THE OWNER AND ARCHITECT OF RECORD. 4. CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING H15 WORK WITH OTHER TRADES AND TO PROTECT FROM DAMAGE EXISTING PIPES USED FOR PROPOSED CONNECTIONS. 5. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EXISTING PIPE AND UTILITIES BEFORE COMMENCING TO WORK AND MAKE MODIFICATIONS AS REQUIRED WITHOUT ADDITIONAL COSTS TO OWNER. G. EXISTING PIPE SERVING AREAS NOT COVERED BY THIS CONTRACT BUT IN SERVICE AT THI5 TIME SHALL NOT BE INTERRUPTED UNLESS IT 15 A TEMPORARY INTERRUPTION FULLY COORDINATED WITH THE OWNER 7. CONTRACTOR SHALL BE RESPONSIBLE FOR CORING, SAW CUTTING AND PATCHING FLOOR SLAB FOR THE INSTALLATION OF NEW PIPING. 8. ALL WASTE AND VENT PIPING SHALL BE SCHEDULE 40 DWV PVC. ALL SLOPES SHALL BE 1/4" P.L.F. FOR 3 "0 PIPES OR LE55 AND 1/8" P.L.F. FOR 4 "0 OR GREATER. 9. PROVIDE SCHEDULE 40 DWV PVC CONDENSATE DRAIN PIPING. TERMINATE ABOVE PERVIOUS AREA OR IN CONDENSATE DRY WELL. 10. ALL ABOVE GROUND DOMESTIC WATER PIPING SHALL BE COPPER TUBING TYPE T' WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS. 1 1 . ALL BELOW GROUND DOMESTIC WATER PIPING SHALL BE COPPER TUBING TYPE "K" WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS. 12. PROVIDE I" THICK MOLDED FIBERGLASS INSULATION WITH ALL SERVICE JACKET. K =0.2G@ 180 °F (A5TM C 335). RUNOUT5 TO INDIVIDUAL TERMINAL UNITS NOT EXCEEDING 12'-0" MAY HAVE .5" THICK. nth r-s U�—, I I ---- - - - - -- I� I W/H 3 G BREAK ROOM SINK I I I I �� - -- (E) CAPPED TOILET I I I I II II 1 (E) FLOOR DRAIN II II II II � 4" PVC 1/4" LF --- - - - - -- --------- II N) i i i3' -1 1 1/4" G' -G 112" E (N) �I --3'- i 1_112" �I3'- I I 1/2" 80 CFM GXG CD .� ---------- - - - - -- n —4 ,---- - - - - - — 80 CFM I I / REMOVE EXISTING / 12" STEPPED UP DISPLAY - / / PLATFORM � I I 1 `.I I I I I � I � II I I I I I C 9C AIR ADMITTANCE VALVE. FLOOR 51NK WITH z AIR GAP w O 3 COMPARTMENT SINK P 51 PROVIDE 3/4" CPVC DRAIN PIPE FROM DRAIN PAN TO EXTERIOR MIN 12" ABOVE GROUND. G 3 O 72x30 Fr Off 3 OC �U CV l \ \ �P s� s� Q- 0 � U N 3 �O WATER RISER DIAGRAM SCALE= 1/4"= P -0" 5VA- CFG745 ,,, C -17 O� o� l0 cm _ GO�e 3 02 G E AGXG 0 C M 4" PVC 1/8" LF v C -9 O WF -G D15P Oo C— I I WF -G D15F' AY \ AIR ADMI ANCE VALVE. 5TUDDOR VENT crnc-- � -➢-I N (P mo9� C- 14 PU� C- 12 0 -G N CV I\ G N 3 �3 3 Q I_ N 3 ` V .2 . 5 \19 Ol r SANITARY RISER DIAGRAM 3° I J / / I / / I \ G P l 1 �2 G�1 CON 4 I l2 G °' �U SCALE= 114"= P -0" 2+ 4" G O . 1 -1 /2" FANJUL & ASSOCIATES, LLC ARCHITECTURE, PLANNING & INTERIOR DESIGN AA26000725 ARTURO G. FANJUL, RA PRESIDENT 900 BAY DRIVE SUITE 208 MIAMI BEACH, FLORIDA 33141 PH. 305 726.8313 FAX 305 356.3686 arturo @fanjularchitects.com "A BETTER LIFE THROUGH DESIGN" f p • ' 1 PT ARTURO G. NJ AR0017585 STATE OF FLORIDA ISTERD ARCHITECT CONSTRUCTION DOCUMENTS FOR: LE MACARON CAFE' 581 1 SUNSET DRIVE SOUTH MIAMI FOLIO: 09- 4025 -030 -0070 PLUMBING PLANS AND NOTES REVISION NO. DATE: 6/18/2012 SCALE: AS NOTED DRAWN: AGF CHECKED: AGF JOB NO. 12-0410 PERMIT NO. OWNERSHIP OF THESE DOCUMENTS & SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT THEY ARE MADE FOR IS EXECUTED OR NOT. THEY SHALL NOT BE USED BY OWNER OR OTHERS ON OTHER PROJECTS OR FOR ADDITIONS TO THIS PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. r e f 4y + 4 . Y N l i r r d R' �q \4.y