12-732-006EQ 125/f 2 1080 sf @ 3w /5f 1080 3,240 EXISTING PANEL VOLTAGE 120124011 PH 13W 3,000 W MAX RATED 1 25 RECESSED, INDOOR 4,800 W TYPE MAINS M.L.O. A/C PACKAGE UNIT HEATER 5,000 W LOAD A B AMPS POLE Wire SUBTOTAL LOADS Wire POLE AMPS A B LOAD KVA KVA CIRCUIT CIRCUIT KVA KVA A/C 2.50 50 100% #6 I 2 # 1 2 2 20 _ 2.40 WATER HEATER 2.50 - 2 3 4 2.40 TOTAL DEMAND LOAD SPARE - 15 #14 5 G #12 1 20 - SPARE SPARE 1.50 20 # 12 7 8 #12 1 20 GL LIGHTS /RECPT. GEN LIGHTS GL 20 # 12 9 10 # 12 1 20 GL GFI APPLIANCE -1 1.50 20 #12 1 1 12 # 12 1 20 GL LIGHTS /RECPT. LIGHTS GL 20 # 12 13 14 # 14 20 1.58 APPLIANCE - 2 EMERGENCY LIGHTS GL 20 # 12 15 1 G # 12 20 GL LIGHTS /RECPT. 51GN 20 #12 17 18 #12 20 GL LIGHTS /RECPT. SUBTOTAL KVA / 0 2.50 5.50 2.40 2.40 SUBTOTAL KVA / 0 SUBTOTAL ' 8.00 4.80 SUBTOTAL ' GENERAL LIGHTING (GQ 3 W /5F 1080 517 3240 WATTS PANEL SUBTOTAL GENERAL LIGHTING TOTAL LOAD 15T 10,000 WATT5 A/C LOAD 100% 12.80 3.24 I G.04 1 1 .04 5.00 I G.04 KVA KVA KVA KVA KVA KVA PANEL SUBTOTAL GENERAL LIGHTING TOTAL LOAD EXISTING 125 AMP SERVICE TO REMAIN UN- CHANGED I G.0 @ 240 V/ I/ GOHZ = G7 AMPS EXISTING LOAD CALCULATION 1080 sf @ 3w /5f 1080 3,240 W APPLIANCE REM. @ 1 500 2 3,000 W WATER HEATER 4,800 W A/C PACKAGE UNIT HEATER 5,000 W A/C CONDENSING UNIT' 1,800 W SUBTOTAL LOADS 1 6,040 W FIRST 10,000 W 100% 1 1 ,040 W AC Load 100% 5,000 W REMAINDER @ 40% _ W - 240 V TOTAL DEMAND LOAD G7 AMP5 ' NON SEQUENTIAL LOAD LE IVE DEMO GENERAL ELECTRICAL NOTES I . ALL WORK REFLECTED ON THESE DOCUMENTS ARE IN COMPLIANCE WITH 201 O EDITION OF THE "FLORIDA BUILDING CODE AND NEC 2008 (NFPA -70). 2. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR AND IN A FIRST CLA55 WORKMAN LIKE MANNER. 3. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL. CONTRACTOR TO PROVIDE LABOR, MATERIALS, PERMITS, FEES, INSPECTIONS, TESTS ETC. 4. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST LIABILITY AND PROPERTY DAMAGE FOR DURATION OF THE WORK. 5. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NO LE55 THAN ONE YEAR FROM DATE OF FINAL INSPECTION AND BUILDING DEPARTMENT APPROVAL. CORRECTION OF DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL C05T TO OWNER AND INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF INSTALLATION THAT MAY HAVE BEEN DAMAGED. G. IT IS NOT THE INTENT OF THESE DRAWINGS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL THE REQUIREMENTS NECESSARY FOR ALL THE EQUIPMENT FURNISHED BY HIM OR OTHER TRADES TO BE PLACED IN PROPER WORKING ORDER. 7. DO NOT SCALE THE DRAWINGS. FOR CLARIFICATIONS REFER TO MANUFACTURER CUT 5HEET5 FOR PRECISE LOCATIONS OF ELECTRICAL OUTLETS FOR UNDER CABINET MILLWORK EQUIPMENT. FOR OTHER INQUIRIES CONTACT OWNER OR ARCHITECT. 8. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED BY THE LATEST NEC CODE. 9. ALL 125 VOLT, 15 AND 20 AMP RECEPTACLES INSTALLED IN A RESIDENCE SHALL BE LISTED TAMPER RESISTANT RECEPTACLES. NO EXCEPTIONS FOR RECEPTACLES ON CEILINGS, ABOVE COUNTERS OR BEHIND APPLIANCES. NEC 40G. I I 10. PROVIDE ACCESSIBLE GFCI RECEPTACLE OUTLET WITHIN THE PERIMETER OF RESIDENTIAL BALCONIES, DECKS, OR PORCHES LARGER THAN 20 SQUARE FEET IN AREA. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN G V2 FEET ABOVE THE STANDING SURFACE. NEC 2 10.52 (E) (3) 1 1 . EQUIPMENT GROUNDING CONDUCTORS ARE REQUIRED TO BE INSTALLED WITH ALL BRANCH, CIRCUITS AND FEEDERS SUPPLYING SEPARATE BUILDINGS OR STRUCTURES. EXISTING INSTALLATIONS ARE ALLOWED TO REMAIN GROUNDED TO THE NEUTRAL CONDUCTOR IF THERE 15 NO GROUNDING CONDUCTOR, NO CONTINUOUS METAL PATH (METAL GAS PIPE, METAL WATER PIPE, OR METAL CONDUIT TO THE STRUCTURE) OR GROUND FAULT PROTECTED EQUIPMENT IN THE STRUCTURE. NEC 250.32 (B) 12. WHERE HOLES ARE BORED IN JOISTS, RAFTERS OR WOOD MEMBERS FOR CABLES OR RACEWAYS, THE EDGE OF THE HOLE MUST BE 1 I/4" FROM THE EDGE OF THE MEMBER OR IT MUST BE PROTECTED BY NAIL PLATES WITH A MINIMUM THICKNESS OF I I/ I G INCH. NEC 300.4 (A) 13. ROMEX 15 NOT ALLOWED IN WET OR DAMP LOCATIONS. THE INSIDE OF RACEWAYS (EMT 4 PVC) INSTALLED OUTDOORS ARE CONSIDERED WET LOCATIONS. OPEN 51DED PORCHES ARE CONSIDERED DAMP LOCATIONS. NEC 300.9 .334.12 14. GAPS AROUND ELECTRIC PANELS, CABINETS AND CUTOUT BOXES ARE LIMITED TO 1/8 ". ALL HOLES I I SI. -A 5 O I t 25 OR 5 0 VOLT RECEPTACLES U INSTALLED OUTDOORS OORSA N DAMP OR WET LOCATIONS MUST BE A LISTED WEATHER - RESISTANT TYPE. NEC 406.8 (A), (B) 16. ALL BREAKERS IN PANELS MUST BE MARKED CLEARLY FOR THE LOADS SERVED. SPARE BREAKERS MUST AL50 BE MARKED. NEC 408.4 17. LOAD DATA PROVIDED IS BASE ON INFORMATION SUPPLIED BY MANUFACTURERS OF VARIOUS EQUIPMENT COMPONENTS. ALL EQUIPMENT AND PANEL SIZES SHALL BE VERIFIED BEFORE ORDERING. 18. CIRCUITS SHOWN ON PLANS ARE USED TO DETERMINE LOAD DATA AND PANEL SIZE. THE CONTRACTOR SHALL PROVIDE CIRCUIT ROUTING TO SUITE THE JOB CONDITIONS. 19. FURNISH AND INSTALL ALL FIXTURES AS CALLED FOR ON THE PLANS OR SELECTED BY OWNER.ARCHITECT. 20. MINIMUM WIRE 51ZE SHALL BE # 14 AWG. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH A THHN INSULATION FOR 51ZE #8 AND SMALLER. CONDUCTORS LARGER THAN #8 SHALL HAVE TYPE THW INSULATION. ALL CONDUCTORS # 10 AND SMALLER MAY BE SOLID AND THOSE #8 AND LARGER SHALL BE STRANDED. ALUMINUM CONDUCTORS MAY BE ALLOWED FOR SERVICE ENTRANCE, IF SPECIFICALLY APPROVED BY ELECTRICAL INSPECTOR. 21. ALL PRIMARY SERVICE CONDUCTORS SHALL BE RUN IN CONDUIT. 22. ALL CONDUITS SHALL BE GALVANIZED RIGID EXCEPT AS FOLLOWS: 1 .1 . CARLON PVC CONDUIT, TYPE "A" U.L. LISTED (OR EQUAL) MAY BE USED WERE INSTALLED UNDERGROUND OUTDOORS, OR UNDER SLAB IN51DE THE BUILDING AS ALLOWED BY CODE. THE CONDUIT FITTINGS AND CEMENT SHALL BE PRODUCED BY THE SAME MANUFACTURER. 1.2. ELECTRICAL METALLIC CONDUIT MAY BE USED INDOORS, OUT OF 501L AND WHERE NOT SUBJECT TO PHYSICAL DAMAGE, IN INTERIOR PARTITIONS AND CEILINGS. 1.3. USE OF NON- METALIC TUBING (ENT) SHALL BE PERMITTED WHEN INSTALLED IN STRICT ACCORDANCE WITH REQUIREMENTS OF NEC ARTICLE 362 AND TUBING SYSTEM MANUFACTURE'S PRINTED INSTRUCTIONS. 1.4. USE OF METAL CLAD (MC) CABLE SHALL BE LIMITED TO BRANCH CIRCUIT AND BE INSTALLED IN STRICT ACCORDANCE WITH NEC ARTICLE 330, AND CABLE SYSTEM MANUFACTURERS PRINTED INSTRUCTIONS. EXCEPT, SHALL BE PROHIBITED FOR USE AS SERVICE CONDUCTOR. 1.5. USE OF NONMETALLIC CABLE (NM) (NMC) 4 (NM5) CABLE SHALL BE USED ONLY WHERE SPECIFICALLY APPROVED BY OWNER 4 ARCHITECT AND ELECTRICAL INSPECTOR, AND SHALL BE LIMITED TO BRACH CIRCUITING AND BE INSTALLED IN STRICT ACCORDANCE WITH NEC ARTICLE 33G, AND CABLE SYSTEM MANUFACTURERS PRINTED INSTRUCTIONS. EXCEPT SHALL BE PROHIBITED FOR USE AS SERVICE CONDUCTOR. 23. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS AND 5HALLCONFORM TO NEMA STANDARDS. PLASTIC BOXES M AY BE USED WHERE PERMITTED UNDER APPLICABLE CODES AND ORDINANCES. 24. PROVIDE UL LISTED COMBINATION SMOKE / CARBON MONOXIDE DETECTORS WITH DISTINCT AUDIBLE ALARM AT LOCATIONS AS INDICATED ON PLANS AND TO SATISFACTION OF AUTHORITY HAVING JURISDICTION. CONNECT SMOKE DETECTORS AHEAD OF SWITCH OF THE AFCI PROTECTED CIRCUIT SERVING THE BEDROOMS. AT LEAST ONE LIGHT FIXTURE IN A BATHROOM OR THE KITCHEN SHALL AL50 BE SERVED FROM THIS CIRCUIT. ALL DETECTORS THROUGHOUT THE DWELLING SHALL BE INTERLOCKED 50 ACTIVATION OF ANY 5MOKE/CAR5ON MONOXIDE DETECTOR CAUSE CORRESPONDING ALARM TO SOUND IN ALL DETECTORS. DEVICES SHALL BE "NIGHTHAWK MODEL 900 -01 14 /KN- CO5M -I5 AS MANUFACTURED BY "KIDDIE" OR APPROVED EQUAL WITH BATTERY BACKUP, FLASHING LED LIGHTS, BEEP5, AND VERBAL WARNING MESSAGE. 25. QUANTITY AND LOCATION OF ELECTRICAL TELEPHONE, TV, DATA OUTLETS LIGHTS AND LIGHT CONTROLS SHALL BE ADJUSTED TO SUIT THE OWNERS REQUIREMENTS AS PER OWNER/ARCHITECT INSTRUCTIONS. THE SAID ARRANGEMENT SHALL NOT BE IN CONFLICT WITH APPLICABLE CODE. 2G. PROVIDE A MINIMUM OF ONE TELEPHONE, ONE DATA AND ONE TV CONNECTION IN EVERY BEDROOM, FAMILY ROOM, OFFICE AND KITCHEN. LOCATION TO BE DETERMINED BY OWNER. 27. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE AND LIGHTING FOR USE BY ALL TRADES AS REQUIRED FOR CONSTRUCTION AND AUTHORITIES HAVING JURISDICTION. FANJUL & ASSOCIATES, LLC ARCHITECTURE, PLANNING & INTERIOR DESIGN AA26000725 ARTURO G. FANJUL, RA PRESIDENT 900 BAY DRIVE SUITE 208 MIAMI BEACH, FLORIDA 33141 PH. 305 726.8313 FAX 305 356.3686 arturo @fanjularchitects.com "A BETTER LIFE THROUGH DESIGN" ARTURO STATE OF F %JUL AROO 17585 REGISTERD ARCHITECT CONSTRUCTION DOCUMENTS FOR: LE MACARON CAFE' 581 1 SUNSET DRIVE SOUTH MIAMI FOLIO: 09- 4025 -030 -0070 ELECTRICAL NOTES REVISION INO. DATE: 6/18/2012 SCALE: AS NOTED DRAWN: AGF CHECKED: AGF JOB NO. 12 -0410 PERMIT NO. OWNERSHIP OF THESE DOCUMENTS & SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECTTHEY ARE MADE FOR IS EXECUTED OR NOT. THEY SHALL NOT BE USED BY OWNER OR OTHERS ON OTHER PROJECTS OR FOR ADDITIONS TO THIS PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. E 2 IF �.. ,I l� � J - %JUL AROO 17585 REGISTERD ARCHITECT CONSTRUCTION DOCUMENTS FOR: LE MACARON CAFE' 581 1 SUNSET DRIVE SOUTH MIAMI FOLIO: 09- 4025 -030 -0070 ELECTRICAL NOTES REVISION INO. DATE: 6/18/2012 SCALE: AS NOTED DRAWN: AGF CHECKED: AGF JOB NO. 12 -0410 PERMIT NO. OWNERSHIP OF THESE DOCUMENTS & SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECTTHEY ARE MADE FOR IS EXECUTED OR NOT. THEY SHALL NOT BE USED BY OWNER OR OTHERS ON OTHER PROJECTS OR FOR ADDITIONS TO THIS PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. E 2 IF