11-1120-001BRING E THE RE( SUPPOR BUILDING ADDRESS: 5811 S.W. 56 TERRACE, MIAMI. FLORIDA 33156 PROJECT LOCATION N.T.S. K� NC)RTH ST, HANDRAIL BE LEGALIZED G V v Vv VJ U U U U J V U V V U V U V U V V J V V ll V V V U U U ALUMINUM STOREFRONT/RAILING NOTE: V V V J V V 1 . ALL ALUMINUM SHALL BE TYPE 6061 —T6, UNLESS NOTED OTHERWISE (U.N.O.) 2. BOLTS & OTHER FASTENERS DIRECTLY IN CONTACT WITH ALUMINUM MEMBERS SHALL BE ALUMINUM, STAINLESS STEEL OR ELECTRO GALVANIZED STEEL, DOUBLE CADMIUM PLATED STEEL BOLTS MAY BE ALLOWED UPON WRITTEN REQUEST TO THE ENGINEER OF RECORD. 3. ALUMINUM PARTS SHALL BE WELDED WITH AN INERT —GAS SHIELDED ARC OR RESISTANCE WELDING PROCESS. FLUX WELDING IS NOT ALLOWED. FILLER ALLOYS SHALL BE AS AMERICAN WELDING SOCIETY SPECIFICATIONS A5.10 -69. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS. 4. DURING ERECTION, ALUMINUM STRUCTURES SHALL BE ADEQUATELY BRACED AND 6. FASTENED TO RESIST DEAD, WIND AND ERECTION LOADS. 5. ALUMINUM IN CONTACT WITH NON — COMPATIBLE METALS SUCH AS STEEL SHALL BE PROTECTED AS PER FBC 2003.8.4.2, g ALUMINUM IN CONTACT WITH CONCRETE SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING. ALUMINUM IN CONTACT WITH WOOD SHALL BE PROTECTED WITH TWO COATS OF ALUMINUM METAL -- AND— MASONRY PAINT, ALL CONECTIONS TO BE WELDED. USE Yle" MINIMUM WELD SIZE, TYPICAL U.N.O. R V V U UVVUV CONSULTING ENGINEERS, INC 4705 S.W. 143RD AVENUE pAGE MIAMI, FLORIDA 33175 PHONE: 786 -351 3663 FERNANDO AZCUE P.E. Lip NSE C}�165521 11 STRUCTURAL `r lz �f• c� 0�C�,�ys CONSULTANTS I �' V V GENERAL NOTES: 1, ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENT. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO START OF WORK AND NOTIFY ARCHITECT /ENGINEER OF ANY DISCREPANCY IN THE DRAWINGS AND OBTAIN HIS APPROVAL BEFORE PROCEEDING WITH WORK. 3. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 4. CONTRACTOR TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED 5, DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 6, NOTIFY ENGINEER 24 HOURS IN ADVANCE PRIOR TO INSPECTION. 7. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER, FOLLOWED BY A CHANGE ORDER. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL , BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS OPROTECT ADJACENT PROPERTIES. 9. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER /ENGINEER. 10. CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD OF CHANGE ORDERS AND VARIATIONS THROUGHOUT THE PROGRESS OF THE WORK. USE ONE SET OF DOCUMENTS EXCLUSIVELY FOR THIS JOB. 11.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, AND FORTHE SEQUENCES AND PROCEDURES TO BE USED. WOOD NOTES: 1, PRIMARY WOOD FRAMING MEMBERS SHALL BE No. 2 SOUTHERN PINE OR BETTER; SURFACE DRY USED AT MAX. 19% M.C. WITH THE FOLLOWING STRESS RATINGS UNLESS NOTED OTHERWISE: Fb (SINGLE MEMBERS) = 1,200 PSI Fb (REPETITIVE MEMBERS) = 1,400 PSI Fv = 90 PSI Fc (PERPENDICULAR TO GRAIN) = 565 PSI ; E = 1,600 KSI 2. METAL STRAPS, CLIPS AND HARDWARE SHALL BE GLAVANIZED TREATED. ` 3, ALL WOOD IN CONTACT KITH CONCRETE SHALL BE PRESSURE TREATED. 4. DECKING DESIGNED FOR A SUPERIMPOSED LOAD OF: 60 PSF. ,, {! 5, SHEATHING: USE 3/4" PLYWOOD APA RATED SHEATHING EXPOSURE I. INSTALL WITH THE LONG DIMENSION ORAL¢. STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS, AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS, PANEL END JOINTS SHALL OCCUR OVER FRAMING, NAIL Q 6" O.C. ALONG SUPPORT PANEL EDGES AND AT INTERMEDIATE SUPPORTS, NAIL @ 4" O.C. ALONG THE PERIMETER OF TEH ROOF. THIS IS BASED ON MAXIMUM SUPPORT SPACING OF 24" O.C. NAILS SHALL BE 8D NAILS WITH 1 3/4" MIN, PENETRATION ON MAIN MEMBER. PROJECT NAME: MR.ANDRES RODRICU RESIDENCE SUN ROC IT Y �.aO0 -r- d MIA ; r UC7'(ldv �� ;EC -1140N IVEO f3Y. STOEERONT LEOAEIZATI'( AS PER CURRENT � 5811 S.W. 56 TERRACE AAMI, FLORIDA 33143 COMM, NO: 11 --0032 l SCALE: AS NOTED DATE: SEPT 2011 I DRAWN: YD CHECKED: FA DRAWING TITLE: — SCOPE OF WORK — LOCATION OF PROJECT — GENERAL NOTES — STRUCTURAL NOTES SHEET NO: GN of 3 I i II i I 7 s vl BC. P "