10-557-011NT �m ug u- - 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE HVAC SYSTEM IN ACCORDANCE WITH THESE DRAWINGS. THE FLORIDA BUILDING CODE 2007 AND THE LATEST EDITION OF THE FOLLOWING PUBLICATIONS: ANS (C) SMACNA MECHANICAL REFRIGERATION (B) NFPA PAMPHLETS 90A & 91 2 ALL AIR CONDITIONING DUCTWORK SHALL BE 1 -112 "STANDARD DUTY FOIL REINFORCED F'BERGLASS (R-6) MANUFACTURED LOGO PRINTED ON THE VAPOR BARRIER WHEN IN UNCONDITIONED SPACE, AND 3/4 "STANDARD DUTY FOIL REINFORCED FIBERGLASS (R -4) MANUFACTURED LOGO PRINTED ON THE VAPOR BARRIER IN CONDITIONED SPACE OR RETURN PLENUM SPACE. 3. ALL EXHAUST DUCTWORK SHALL BE CODE GAGE GALVANIZED SHEET METAL. 4. DUCT SIZE SHOWN ARE NET FREE AREA INSIDE 5. ALL AIR DEVICES (DIFFUSERS, REGISTERS AND GRILLES) SHALL BEALL ALUMINUM CONSTRUCTION, WITH EXPOSED SURFACE CHEMICALLY TREATED TO RECEIVE PAINT TO MATCH COLOR OR AIR GUIDE OR APPROVED EQUAL. 6. PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS. Z THERMOSTATS SHALL BE COMBINATION COOLING 0 HEATING WITH SYSTEM COOL/ AUTO/ HEAT/ OFF AND FAN ON/ AUTO SELECTOR SWITCHES. 8. REFRIGERANT PIPING SHALL BE COPPER TYPE A" WITH 1/2°' ARMAFLEX. INSULATION SHALL BE PROVIDED FOR SUCTION LINES. 9. PROVIDE NEW FILTERS FOR FAN COIL BEFORE STARTING. THESE FILTERS MUST ALSO BE REPLACED PRIOR TO FINAL ACCEPTANCE BY OWNER. 10. GENERAL CONTRACTOR IS TO HIRE AN INDEPENDENT TEST AND BALANCE COMPANY WHICH SHALL PROVIDE 3 SET OF THE REPORT SIGN AND SEALED BY THE PROFESSIONAL ENGINEER FROM THE COMPANY PRIOR OF ACCEPTANCE OF WORK. 11. MECHANICAL CONTRACTOR ITS TO PROVIDE TURNING VANE AT ALL CHANGE OF DIRECTIONS OR TO PROVIDE TURNING RADIO, ALL OUTLETS SHALL HAVE EXTRACTORS OR SCUPPERS. AND SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE REGULATIONS. ® CEILING GRILLE SEE SIZE SCHEDULE SUPPLY DUCT TO MATCH NECK SIZE TYP. Q RETURN AIR GRILL MANUFAC. THERMOSTAT DISCHARGED SHALL BE AIR FLOW DIRECTION ( ARROWS DENOTE -- •-- l WAY, 2 WAY, ETC., SEE PLANS —J�• -- RETURN OR EXHAUST, SEE PLANS. OAL OUTSIDE AIR INTAKE CCs CEILING GRILL A J-V AIR HANDLER UNIT GU CONDENSING UNIT mi CUBIC FEET PER MINUTE DRILL BLOCKING TO FIT OUTSIDE OF REF. LINES CAULK WATER TIGHT METAL BOOT PAINTED TO MATCH EXTERIOR FACADE IN REF. LINES RUN IN ATTIC (MIN.) SUCTION CONNECTION j LIQUID CONNECTION 1 -112" LONG "HELT1' POWER ACTIVATED PIN INTO SLAB (TYPICAL OF 4) y 4" CONCRETE SLAB INSULATED SUCTION LINE (NO JOINTS ALLOWED) SEE FLOOR PLAN FOR PIPE SIZES LIQUID LINE (NO JOINTS ALLOWED] � �-�" � " ' ° - PROVIDE 4" PVC SLEEVE FOR 1.25 TO 3 TONS & 6" PVC SLEEVE FOR 3.5 TO 5 TONS IF REF, LINES RUN UNDER SLAB CONDENSING UNIT MOUNTING DETAIL N.T.S. f gfJ81 NJ I fool• r t 4" THICK CONCRETE BASE N.T.S. NOTE PROVIDE ANCHOR BOLT WITH A MINIMUM OF 500 POUND PULL -OUT RESISTANCE. SHALL SECURE THE AIR CONDITIONING CONNSER UNIT FROM WITHIN THE UNIT TO THE CONCRETE SLAB ON WHICH THE UNR RESTS FOR THEFT PREVENTION. ' POWER & CONTROL LOCATION 1' IN LIQUID LINE W/O INSULATION SUCTION LINE W/ 1 /2" ARMAFLEX INSULATION & VAPOR BARRIER NOTE UNITS SHALL BE CLEAR BY 3" MIN. FROM DRIP LINE. CU MOUNTING DETAIL 314" DEEP x 1/8" POWERED ACTUATED PINS FLEX DUCT UP TO 29 'WITH ORIG "DEEP N.T.S. O DUCT HANG DETAIL N.T.S. s RIGID DUCT UP TO 29" WITH OR T 6" DEEP 3" WIDEx 26 GA G.M. STRIP AT SUPPORT STUD I to A CG P2XP2 FAN-COIL DESIGNATION SUPPLY MBTUH ENTERING 7EM AIR DUCT MANUFAC. MODEL DISCHARGED SHALL BE TOTAL ATTIC MECHANICAL ATTACHED DB SPACE TO AHU HTNG KW PROVIDEA MIN. OF 4"SPACE _ I q UQ. OF AHU SIDE TO ASSURE ADEQUATE ACCESS FOR CEIUN WALLS AHU -3 CONSTRUCTION & CLEANING ` 19.6 14,8 1{ REF. UN 240 T PROVIDE CAP -OFF W/ 1 125 COIL/HEAT SECTION I 1 /4" PERFORATED FOR VENT RHLLHM2417JA FAN SECTION t a 12"MIN. 314" FILTER ACCESS — a � I PROVIDE E.Z. TRAP FLOW SWITCH NO COMBUSTIBLE MATERIALS ON SECON�ARY C.D. DRAIN TO B SHUT DOWN THE UNIT IN CASE OF ALLOWED IN PLENUM OVER FLOI�V. PREFAB M L. FRAME i F.F. A.H.0 - 1 CLOSET INSTALLATION DRILL BLOCKING TO FIT OUTSIDE OF REF. LINES CAULK WATER TIGHT METAL BOOT PAINTED TO MATCH EXTERIOR FACADE IN REF. LINES RUN IN ATTIC (MIN.) SUCTION CONNECTION j LIQUID CONNECTION 1 -112" LONG "HELT1' POWER ACTIVATED PIN INTO SLAB (TYPICAL OF 4) y 4" CONCRETE SLAB INSULATED SUCTION LINE (NO JOINTS ALLOWED) SEE FLOOR PLAN FOR PIPE SIZES LIQUID LINE (NO JOINTS ALLOWED] � �-�" � " ' ° - PROVIDE 4" PVC SLEEVE FOR 1.25 TO 3 TONS & 6" PVC SLEEVE FOR 3.5 TO 5 TONS IF REF, LINES RUN UNDER SLAB CONDENSING UNIT MOUNTING DETAIL N.T.S. f gfJ81 NJ I fool• r t 4" THICK CONCRETE BASE N.T.S. NOTE PROVIDE ANCHOR BOLT WITH A MINIMUM OF 500 POUND PULL -OUT RESISTANCE. SHALL SECURE THE AIR CONDITIONING CONNSER UNIT FROM WITHIN THE UNIT TO THE CONCRETE SLAB ON WHICH THE UNR RESTS FOR THEFT PREVENTION. ' POWER & CONTROL LOCATION 1' IN LIQUID LINE W/O INSULATION SUCTION LINE W/ 1 /2" ARMAFLEX INSULATION & VAPOR BARRIER NOTE UNITS SHALL BE CLEAR BY 3" MIN. FROM DRIP LINE. CU MOUNTING DETAIL 314" DEEP x 1/8" POWERED ACTUATED PINS FLEX DUCT UP TO 29 'WITH ORIG "DEEP N.T.S. O DUCT HANG DETAIL N.T.S. s RIGID DUCT UP TO 29" WITH OR T 6" DEEP 3" WIDEx 26 GA G.M. STRIP AT SUPPORT STUD I to A CG P2XP2 FAN-COIL DESIGNATION CFM MBTUH ENTERING 7EM ELECTRICAL DATA MANUFAC. MODEL OBS TOTAL SENSIBLE WB DB VOLTS PHASES HTNG KW 240 FUSES UQ. SUC. COND. AHU -3 600 19.6 14,8 67 75 240 T 5.0 1 125 20 RHEEM RHLLHM2417JA 318" 314" 314" + LOAD AT 125% AS PER MANUFACTER SPECS. CONDENSING UNIT DESIGNATION MBTUH TEMP. ENT. CONDENSER ELECTRICAL DATA MANUFAC. MODEL OBS OR SEER AREA SERVED VOLTS I PHASES IWIREAMP4 FUSES CU -3 19.6 95 240 1 15 20 RHEEM i3AJM 18A01 14.5 SHOWN 12 3 1 > YES NO DUCT SMOKE DETECTOR X FIRE DAMPERS) X SMOKE DAMPERS X FIRE RATE ENCLOSURE X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY X FIRE STOPPING Q SMOKE CONTROL X THERMOSTAT (PROGRAMMABLE) X qq 0 ¢N I, C NEO F L CL I a — i ENTRY /f 314. CD & TRAP REF: UN NO A/C SPACE NEW ATTIC ACCESS PANEL PERFORATED VENT CAP. SLOPE 1/8" /FT Z N RTU UNIT 2" MIN. FOR 2-112 TONS OR LESS, 3" MIN. FOR 3 TONS OR MORE. CONDENSATE TRAP DETAIL N.T.S. l 1 t z d t i 4 i C 9° k! II �I i€,_ K.I T r ti rr „jE i 0 CU -3 SCALE: 114 = 1 ' —O t` ..n cA DTu 6- VIA HVAC DESIGN RECZLJ►RE: YES NO DUCT SMOKE DETECTOR X FIRE DAMPERS) X SMOKE DAMPERS X FIRE RATE ENCLOSURE X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X THERMOSTAT (PROGRAMMABLE) X R.EVBM BY U. W V3 z DATE 06 -07 -10 SCALE A5 5HOM DRAWN OM13 JOB 1014 SHM7 14850 B.W. 26 ST SUITE #212 MIAMI, FLA. 33175 OFFICE (305) 552 -B538 FAX (305 ?.552 -8462'" E-MAIL rma@rmE3ENr..com ° , "¢4Pa�"�' L.C. No. 28544 EDMUNDO.LARCiAESP / i,DA � ����® 7'tf� '�° MECHANICAL. ENGINEER . a'� ?"- P.E.. t