Loading...
10-557-0100 TYPICAL X- 5RACING N.T.S. M i' m' K. r z.r V 02 SOUTHERN YELLOW E CROSS BRACING MEMBERS PTENED TO TRUSSES W/2 -trod LS EACH END :FER TO TRUSS NOTES AND TRUSS TOUT FOR LOCATION) 2'x4' CONT. LATERAL WOOD BRACING% NAILED TO BOTTOM CHORD MAXIMUM V -0' SPACING AND AS REQUIRED BY TRUSS MANUFACTURER (REFER TO TRUSS NOTES AND TRUSS LAYOUT FOR LOCATION) 1/2 (LI or L2, WHICHEVER 15 GREATER) + 'b' AA Fk A UP n 1 AM ='P=G? (2) 16d NAILS EACH MEMBER 2'x4' CONT. LATERAL WOOD BRACING NAILED TO BOTTOM CHORD MAXIMUM (V-0' SPACING AND AS REQUIRED BY TRUSS MANUFACTURER (REFER TO TRUSS NOTES AND TRUSS LAYOUT FOR LOCATION) n�r 24' o c (OvERLAP • SPLICES) PRE - ENGINEERED WOOD TRUSS PLAN VIEW TYPICAL LATERAL 5RACE &FLICE N T.S. 1/4 (L2) MIN, CLEAR SPAN CLEAR SPAN TYPICAL CONC T E 5EAM/GOLUMN REINFORCEMENT5 SCALE: N.T.S. 0 PROVIDE 2 -05 BARS TOP 4 BOTTOM OF EXISTING BEAM X36' LONG EMBEDED 6' MM w/HILTI HIT HY 150 EPDXY SYSTEM. PROVIDE: 2' COVER FOR DOWELS EXISTING CONCRETE TIE BEAM EXISTING MASONRY WALL NEW CONCRETE TIE BEAM SEE PLANS 4 SCHED FOR SIZE 4 RE INF. =3' -0' a =3' -0' ------------------- � s (D / i ----{-------------{--- a=3'-0' ZONE I - 50.03 PSF ZONE 2 - 59.29 PSF ZONE 3 - 5929 PSF a =3' -0' ROOF PLAN SHOWING- WIND PRESSURE ZONES_____1, 2 3- CONCIRRETE BEAM T EXISTING BEAM ATTACHMENT DETAIL SCALE: 3/4' = 1' -0' 1) EXTEND BOTTOM BARS W PAST ALL OPENINGS GREATER THAN V -0' ON BOTH SIDES. 2) TIE BEAMS SHALL BE CONTINUOUS REINFORCEMENT, PROVIDED BY LAPPING: SPLICES NOT LESS THAN 30'. CONTINUITY SHALL BE PROVIDED AT ALL CORNERS BY BENDING 2 BARS FROM EACH DIRECTION AROUND THE COMER 30' OR BY ADDING 20 5 BENT 30' EACH LEG. 3) CONTINUITY AT COLUMNS SHALL BE PROVIDED BY CONTINUING HORIZONTAL REBARS THRU COLUMNS OR BY BENDING HORIZONTAL REIN. INTO COLUMNS A DISTANCE OF 30'. 4) HOOK TOP OF VERTICAL BARS IN ALL TERMINATING COLU"N.S 2' BELOW TOP OF SLAB AND 3' BELOW TOP OF THE TIE BEAM. 5) RENFORCMG STEEL SHALL CONFORM TO ASTM A -615 GRADE 60. REINFORCING STEEL SHALL BE DETAILED AND FABRICATED ACCORDING TO THE 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES'. HOOK ALL DISCONTINUOUS TOP RENFORCMG. PROVIDE CORNERS w/ 2' 5 X 4' -0' BARS. CLEAR COVER FOR RENFORCMG BARS SHALL BE: FOOTINGS 3' LINFOR'1ED FACES - 3' SLABS 3/4' FORMED FACES IN BEAMS /COLUMNS — 11/2' CONTACT w/ EARTH_ 2' CONCRETE NOTES 1) STRUCTURAL CONCRETE SHALL CONFORM w/ ACI -301 IT SHALL REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI M 28 DAYS FOR SLABS 4 FOOTING. 2) AGGREGATES SHALL BE CLEAN AND GRADED MAX" SIZES 3/4' CONCRETE ASTM C -33 SHALL CONFORM TO ASTM C -94 3) CONCRETE TESTING IS REQUIRED AS FOLLOWS: 1 SET OF 5 CYLINDERS FOR EVERY 50 CU. YDS. OF CONCRETE AS PER ASTM C -94 4) MAXItW PERMISSIBLE SLUMP IS 5 -6' IN STRUCTURAL. CONCRETE w/ THE EXCEPTION BEING SAND CEMENT GROUT STRUCTURAL NOTES APPLICABLE CODES: A: F.B.C. DADE COUNTY 2001 EDITION. B: A.C.I. 319-05 REINFORCED CONCRETE C: REINFORCED MASONRY BY ACI.530 -05 AND THE MASONRY DESIGNERS GUIDE BY AC.I, TM, ASC.E. E: WIND ANALYSIS AND DESIGN PER ASCE.1 -05. MASONRY NOTES REINFORCING STEEL fy = 6000 PSI. Ts = 24OW PSI. Es = 29jdWOW PSI. Em = 1 50,000 P.S.I. N = Es/Em = 21.48 ALL BLOCK W ASTM C -90 HOLLOW UNIT MASONRY DESIGN M = 1,500 P.S.I. 4 f'c = 1,900 PS.I. (PER TABLE 2 ACI 5301) GROUT SHALL COMPLY w/ ASTM 0416, 28 DAYS MR COMP. STRENGTH = 3,000 PSI. GROUT SLU'1P REQUIRED - - - -- 8' TO II' PROVIDE C .EANOUT HOLES AT TOPj" MIDDLE AND BOTTOM OF FILLED CELL MORTAR SHALL COMPLY w/ A,STlt 210 MORTAR SLUMP REQUIRED - - - -- 5' TO W CONTRACTOR TO CONSOLIDATE GROUT LIFTS w/ 3/4' VIBRATOR PLYWOOD ROOF DIAPHRAGM L ROOF DIAPHRAGM SHALL COMPLY w/ THE DESIGN RECOMMENDATIONS OF 'APA DESIGN / CONSTRUCTION GUIDE - DIAPHRAGMS' AND THE LOCAL BUILDING CODE. 2. PLYWOOD ROOF DECKING SHALL BE 19/32' MNIMUM THICKNESS, AND SHALL BE CONTINUOUS OVER TWO OR MORE SPANS, w/ FACE GRAN PERPENDICULAR TO THE SUPPORTS. 3. CONNECT PLYWOOD DIAPHRAGM TO STRUCTURE w/ Sd RING SHANK NAILS, SPACED AT Vor- MAX AT EDGES AND AT 6'oa. ALONG INTERMEDIATE SUPPORTS. 4' o - a DIAPHRAM BOUNDARY AND Sd RNG SHANK NAILS * 4' oz 6 GABLE ENDS. 4. INSPECTIONS: SHALL. COMPLY w/ THE LOCAL BUILDING CODE REQUIREMENTS FOR INSPECTIONS (BY THE MUNICIPALITY, ARCHITECT OR ENGINEER) OF SPECIFIED COMPONENTS OF THE ROOF STRUCTURE REQUIRING INSPECTIONS. SOIL COMPACTION NOTES L REMOVE ALL VEGETATION, TOPSOIL, AND ORGANIC MATERIAL w/ IN THE BUILDING AREA PLUS FIVE (5) FEET OUTSIDE THE BUILDING FOOTPRINT. THE AREA UNDER FOOTINGS, FOUNDATIONS, AND CONCRETE SLABS ON GRADE SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO PLACEMENT OF FILL. 2. COMPACT THE CLEARED AREA TO A MINIMUM M COMPACTION OF 95 PERCENT OF THE DRY SOIL DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST -ASTM D -1551 PRIOR TO PLACEMENT OF ANY ADDITIONAL FILL REQUIRED. 3. FILL AND COMPACT THE CLEARED AREAS IN LIFTS NOT GREATER THAN 12 INCHES OF LOOSE THICKNESS TO ELEVATE TO THE REQUIRED GRADE FILL MATERIAL FOR AREAS IN SUPPORT OF FOOTINGS 15 TO BE A MIXTURE OF LIMEROCK AND SAND, FREE OF VEGETATION, ORGANIC MATERIAL, CONSTRUCTION DEBRIS, AND LARGE ROCKS. IF SUFFICIENT COMPACTIBILITIES EXIST, SOILS MAY BE PLACED AND COMPACTED IN GREATER LIFT THICKNESSES. FILL MATERIAL FOR SLAB ON GRADE AREAS MAY BE CLEAN SAND, FILLED AND COMPACTED IN LIFTS NOT GREATER THAN 12 INCHES OF LOOSE MATERIAL 4. COMPACT EACH LIFT TO A MINIMUM COMPACTION OF 95 PERCENT OF THE DRY SOIL DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST - ASTM 0-1551 PRIOR TO PLACEMENT OF ANY ADDITIONAL FILL REQUIRED. PRIOR TO COMPACTION, THE MOISTURE CONTENT OF EACH LIFT OF FILL MATERIAL SHALL BE ADJUSTED TO w/N PLUS/MIdU5 2 PERCENT OF THE OPTIMUM MOISTURE AS DETERMINED BY THE MODIFIED PROCTOR TEST - ASTM D -1551. 5. COMPACTION OF BUILDING SITE SHALL BE VERIFIED BY MEANS OF ONE FIELD DENSITY TEST FOR EACH 2500 SQUARE FEET OR FRACTION THEREOF FOR EACH LIFT OF COMPACTED SOIL FOR BUILDING PAD OR SLAB AREA ONE FIELD DENSITY TEST WILL ALSO BE REQUIRED FOR EVERY 50 LINEAL FEET OF EXCAVATED SPREAD FOOTING, AND EVERY ISOLATED FOOTING EXCAVATION. FIELD DENSITY TESTS SHALL BE PERFORMED AS PER ASTM D -2922. STRUCTURAL STEEL L STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING GRADES= A ALL W=, ANGLE, BASE PLATES, C04K PLATES (UON)- - -ASTM A36 (Fu =36 KSU B. STRUCTURAL TUBE---------------- - -ASTM A500 GRADE B M046­1<51) C. STEEL PIPE--------------------- - -ASTM A53, iiAZE B (r-Y= KSO 2. GROUT VJC WAS MASTER FLOW 113, AS MANUUFFNON-METALLIC REED BY MQ5tIk SHRINK OR APRROVED EQUAL. 3. ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF 'THE STANDARD CODE FOR WELDING IN BUILDING CONSTRUCTION' OF THE AMERICAN WELDING SOCIETY. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS USING E10 -XX ELECTRODES. GENERAL NOTES 1) ALL POURED IN PLACE GROIJT FILL CELLS AND TIE BEAMS AND COLUMNS TO BE 3000 P51 AT 28 DAYS MR 2) ALL CONCRETE WORK IN ACCORDANCE w/ 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING' (ACI- 301 -99). 3) NO ADMIXTURES PERMITTED w/OUT WRITTEN APPROVAL OF ENGINEER 4) COMPACT INTERIOR FILL TO 95% OF MODIFIED PROCTOR MAX" DRY DENSITY AS PER ASTM D - 1551 AT OPTIMUM MOISTURE CONTENT. 5) PRIOR TO CONSTRUCTION PROVIDE TERMITE PROTECTION TREATMENT TO SOIL IN ACCORDANCE w/ NATIONAL PEST CONTROL ASSOCIATION' STANDARDS. SUBMIT TERMITE INSPECTION REPORT PRIOR TO CONSTRUCTION. 6) PROVIDE CLEANOUT OPENING AT THE BOTTOM OF REINFORCED MASONRY CELLS THAT ARE BEING FILLED TO ENSURE THAT THE CELL 15 FILLED. PROVIDE WEEP HOLES AT 113 AND 2/3 OF SPAN. 1) ALL REIN. STEEL SHALL CONFORM TO A.S.T.M. A -615 GRADE 60. REINFORCING STEEL SHALL BE DETAILED AND FABRICATED ACCORDING TO THE 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES' LAP CONTNOUS REINFORCING A MIN. OF 30' IN BEAMS 36 BAR DIAMETERS IN SLABS, HOOK ALL D15CONTMZ TOP REMFORCMG. PROVIDE AT ALL CORNERS 25 60' LONG BENT. 8) CLEAR COVER FOR REINFORCING SHALL BE: SLABS: 3/4' FORMED FACES IN CONACT w/ EARTH _ 2' UNFORMED FACES 3' 9) ALL BLOCK MASONRY WALLS SHALL HAVE HORIZONTAL REINFORCEMENT ' DUR -O -WALL LADDER TYPE SPACED 16' ON CENTER USE PREFABRICATED CORNERS AND TEES BY TVR -O -WALL AT CORNERS AND JUNCTIONS OF WALLS MASONRY WITS SHALL BE 2 CELL HOLLOW UNITS CONFORMING TO ASTM C -90 w/ COMPRESSIVE STRENGTH OF tWO PS.I. ON THE NET CROSS- SECTIONAL AREA AND SHALL BE LAID IN RUNNING BOND. MORTAR SHALL BE TYPE 'S' w/ f'm = 1500 PSI. 10) THE USE OF A SCALE TO OBTAIN DIMENSIONS NOT SHOWN ON THE PLANS IS STRICTLY FORBIDDEN. THE ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS RESULTING FROM SUCH ACTIONS. 11) CONTRACTOR TO LOCATE ALL EXISTING UTILITIES PRIOR TO EXCAVATION. 12) USE CONCRETE MASONRY UNITS CONFORMING TO ASTM C90: DESIGN Pc =1900 PSI. WHERE ANCHOR BOLTS ARE SET IN MASONRY WALL, FILL BLOCK CELLS w/ GROUT FOR BOLTED COURSE ADD ONE GROUTED CELL ABOVE AND TWO GROUTED CELLS BELOW ANCHOR ELEVATION. 13) GROUT USED IN THE WORK SHALL CONFORM TO ASTM C416 w/ A SLUMP MIIX OF 8' TO 11, PROVIDE CLEANOUT AND INSPECTION HOLES AT FILLED CELLS AT BOTTOM COURSE. ALL MORTAR SHALL CONFORM w/ ASTM 0210. 14) POUR GROUT IN LIFTS NOT TO EXCEED 4% 15) GROUT USED IN THE WORK SHALL OBTAIN A MINIMUM COMPRESSIVE STRENGTH OF 3000 P51 IN 28 DAYS. GROUT SLUMP REQUIRED - - - -- 8' TO 11' PROVIDE CLEANOUT HOLES AT TOP, MIDDLE. WO A SPECIAL INSPECTION BY A FL CERTIFIED ENGNEER OR SPECIAL. INSPECTOR, WILL BE REQUIRED FOR ALL ENGNEERED MASONRY CONSTRUCTION, SOIL COMPACTION AND ROOF TRUSSES OVER 35' LONG OR (W-0' HIGH. 11) ALL SPECIFIED MATERIALS AND CONNECTORS CAN BE SUBSTITUTED w/ EQUAL OR BETTER. w/ THE APPROVAL OF ENGINEER OF RECORD. 18) ALL STRUCTURAL LUMBER TO BE SOUTHERN PINE Na 2 OR BETTER MINIMUM BENDING STRESS, Fb = 1200 PSI. YOUNG'S MODULES, E =1,500,000 PSI. WIND DESIGN LOADS WND DESIGN PER ASCE 1 -05 MEAN ROOF HEIGHT a 14' -11' WIND DESIGN SPEED 146 MPH EXPOSURE C STRUCTURAL CATEGORY II Kd 1.0 GROSS PREP PER ASCE COMPONENTS AND CLADDING ZONES I, 2, 4 3: ZONE I - 5003 PSF ZONE 2 - 59.29 PSF ZONE 3 - 5929 PSF SHOP DRAWING NOTES -WOOD TRUSMS PRIOR TO ANY FABRICATION, SHOP DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL CITY Off" rr. r �' r�r r 7'RUCT'.l L F rrra.. PGVO,q t D Alex Kondrat & Associates, �Vil : gt •°,° '; Alex Kondrai - P.E. #58086, C.A. #00009717 12900 S`V 128 Street, Suite 104 = • c�c,�G �`° = Miami, Florida 83186 Ph. (786) 293 -2888 Fax. (786) 293 -2878 /K i' qA ,�P�satt;dr