10-171-0011/16" S/S CABLE IN 1/2" EMT TO XV CONTROL BOX IN CABINET USE CORNER PULLEYS AT ALL— CHANGE OF DIRECTIONS 3/8 ""� " SCHD. 40 ED IRON SUPPLY VENT PLUG 1/4 " OD COPPER TUBE (2) WHDR -260 CYLINDEF 1/16" S/S CABLE IN 112" EMT TO XV CONTROL BOX IN CABINET USE CORNER PULLEYS AT ALL CHANGE OF DIRECTIONS 5 10 10 10 10 IfO N I / I I SEE PLAN VIEW �I FOR SPECIFIC 0 - - - - -- 7 -- 7 LOCATION OF 1 PULL STATION KIDDE (10 I O 12 13 13 I I I I I I I I I I I I I I MECHANICAL GAS VALVE FIELD LOCATE AND 9 _ - CONNECT TO FUSIBLE LINKS AND REMOTE PULL STATION /TO GAS VALVE ;V ,ONTROL 3OX CONTROL PANEL �— FIRE CABINET lil HOOD & LIGHT SWITCH 10 71 0„ NON COMBUSTIBLE 1" THICK STAINLESS STEEL END PANEL 11 SPLASH 11 SHIELD 0 H - �I II II O B C @D 'F-IRE SUPPRESS ON GOAT ON VIEW SCALE: 1/2" — V-0" CONTRDL PANEL & DOUBLE MICROSWITCH PROVIDED BY HOOD DEPOT. CONTROL PANEL PRE —WIRED TO LIGHT SWITCH, HOOD SWITCH, AND 1 POLE OF FIRE SYSTEM MICRO�WITCH. THE CONTROL PANEL IS PRE —WIRED TO SHUTDOWN MUA AND TURN ON EXHAUST IN CASE OF FIRE. ALL OTHER CONNECTIONS ARE TO BE MADE BY OTHEFS. THERE IS (1) NO /NC MICROSWITCH AVAILABLE IN TH. J —BOX FOR FIRE ALARM ACTIVATION. FOR OTHER REQUIREMENTS SUCH AS THE SHUTDOWN OF ELECTRIC APPLIkNCES AND RECEPTACLES UNDER HOOD, GAS SOLE ,OID ACTIVATION, AND ANY OTHER REQUIREMENTS BY NATIOIIAL, STATE, OR LOCAL AUTHORITIES HAVING JURI`:CTION USE TERMINALS NO AND NO AS REQUIRED. NC /I`0 HAVE 1 15V /1 PHASE AND ARE ACTIVATED UPON FIRE _NSTEM AC i l:A ETON. NOTE: IF THERE- IS NO BUILDING ALARM IT MAY BE `�_QUIRED TO PROVIDE A HORN TO BE SOUNDED JPON FIRE SYSTEM .ACTUATION. CONTACT YOUR ',UNICIPALITY FOP, THFIR REQUIREMENTS. EIRE CABINETFIRE SYSTEM DETAILS KIDDE NOZZLE DETAIL RING PPITEPN I DM ADP F GR'w' R LPF LPR 0 1 2 3 4 &.2- 0 RINGS RING RINGS R N ��INGS INGS RINGS �'�V DISC do CORE DUCT TEMPER,4TS °r- SEUSOR DETAIL DUCT TLMPERATURE SENSOR TEMPERATURE SENSOR TO BE PLACED IN THE GREASE EXHAUST DUCT TO ACTIVATE THE EXHAUST HOOD SYSTEM PER FLORIDA MECHANICAL CODE 507.2.1.1 OPERATION. WHICH STATES TYPE I HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR. THE ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES, BY MEANS OF HEAT SENSORS CR BY MEANS OF OTHER APPROVED METHODS. TO TERMiP,AL '4' IN THE HOOD DEPOT CONTROL PANEL TO TERMINAL '5' IN THE HOOD DEPOT CONTROL PANEL ) STEEL 10 7' -O" ill O O K IDGr: W H D R CHE D U LE w NOZZLE APPLICATION COVERAGE COVERAGE LENGTH OF DUCT PER NOZZLE SPECIAL NOTES FOR COVERAGE FLOW PQINN�S (�1 TANK 1 No. F.P. ;TANK 2 ;No. F.P. (2) ADP Duct 100" Pi_RIMETER UNLIMITED (2) ADP nozzles req'd (f.p.) 0 0 O 4 NOZZLE APPLICATION COVERAGE, NOZZLE HEIGHT (in inchois) SPECIAL NOTES FOR COVERAGE FLOW PQI�TS (1 ) 1 No. F.P. 2 No. F.P. ADP Plenum 10' ': 4' N/A "V" Bank or Single (f.p.) 1 1 1 1 N O Z Z L_ E APPLICATION CC C O V Cw I N,� G E NOZZLE HEIGHT LiP.IITATION FROM SPECIAL NOTES POIDW 1 2 MANUFACTURER - KIDDE FIRE SYSTEMS car;NC SURFACE FOR CCiERCCs (f.p.) No. F.P. No. F.P. O TANK #1 = WHDR --260 F Single Vat Fryer (drip boards 1 to G) 18" X 18" 27" min/45" max 45 degree to 1I0 degree 2 1 2 0 0 ADP Upright Broiler 30.25" X 34" n/o within top 4" of 1 1 1 0 0 SUPPLY Salamanders FOR TANK I•roiler comportment NONE 40 TANK #4 = NONE SUPPLY R Four Burner Range 28" x 28" 20" min /42" max V radius from midpoint 1 2 2 0 0 GRW Radiant Charbroiler (Gas) 24" X 21° 24" min/4n" max 45 degree to �0 degree; 9 9 1 2 2 0 0 TOTAL FLOW POINTS g 5 MFG: KIDDE- FENWALL GENERAL NOTES MAXIMUM FLOW POINTS: For piping allowances and balances WHDR125: 4 Flow Points lJ L300 refer to KIDDE— FENWALL Technical WHDR260: 8 Flow Points _ Manual —U.L. File EX5559. WHDRA-00: 12 Flow Points �— The System installation shall conform WHDR600: 18 Flow Points to the requirements of NFPA #I7A do 96 DUAL WHDR400: 24 Flow Points (manifolded) and all applicable State and Local Codes. KIDDE PARTS LEC.3END SYMBOL DESCRIPTION KIDDE P/N APPLIANC'- NOZZLE GRW, R, F, ADP, DNI, LPF, LPR L PLENUNI NOZZLE ADP r 50TN PERIMETER DUCT NOZZLE ADP 100IN PERIMETER (8) ADP DUCT NOZZLE REMETE PULL STATI ❑N 8i- 120050 -001 1 GAS VALVE �a 2', 2.5% 3', FIRE SYSTEM DESIGN SCHEDULE FIRE SYSTEM COMPONENTS #1 SIZE = 7' -0 "x48" HOOD #2 SIZF MANUFACTURER - KIDDE FIRE SYSTEMS 12"x16" ACTUATION PER NEPA 17A ACTIVATION 3. SYSTEM TO HAVE AUDIBLE_ DEVICE TO 6- ALL MOTORS, LIGHTS AND OTHER O TANK #1 = WHDR --260 SUPPLY LINE FOR TANK SPECIFICALLY APPROVED FOR SUCH USE 20 TANK #2 = WHDR -260 SUPPLY LINE FOR TANK #2 OJ161 ' O TANK #3 = NONE SUPPLY LINE FOR TANK #3 NONE 40 TANK #4 = NONE SUPPLY LINE FOR TANK #4 NONE. `5 CONTROL BOX = XV MECHANICAL PULL STATION UJ 360' FUSIBLE LINK R 450' FUSIBLE LINK C) GAS VALVE = MECHANICAL 10' ADP NOZZLE 11 R NOZZLE 12 F NOZZLE 13 GRW NOZZLE 14 LPR NOZZLE 15 DM NOZZLE 16 LPF NOZZLE 17 K TYPE EXTINGUISHER (BY OWNER) HOOD #1 SIZE = 7' -0 "x48" HOOD #2 SIZF = 7' 0 "x4.8" APPLIANCE LAYOUT APPLIANCE TYPE FRYER O SALAMANDER BROILER 6 BURNER RANGE RADIANT CHARBROILER 0 COUNTER TOP PIZZA OVEN O HOT SANDWICH PRESS FIRE SYSTEM, NOTES HOOD #1 EXHAUST DUCT SIZE = 12"x16" HOOD #2 EXHAUST DUCT SIZE = 12"x16" OVERALL SIZE 16"x2,3" 36 "x17" 36 "x28" 30 "x24" 41 "x35" 33 "x15" COOKING SURFACE 1 5 "x 1 4" 30 "x 17" 36 "x24" 27 "x21" NO PROTECTION REQ'D NO PROTECTION REQ'D 1. NO GALVANIZED PIPE TO BE USED ONLY 4. ALL HOOD PENETRATION'S TO BE WELDED USE SCHEDULE 40 BLACK IRON STEEL PER LIQUID TICHT OR SHALL USE A UL LISTED NFPA j 17A SEAL PER NEPA j 17A 2. SYSTEM TO HAVE REMOTE PULL STATION 5. ALL ELECTRIC AND FUEL TO ALL FOR MANUAL MEANS OF ACTUATION AND EQUIPMENT AND RECEPTACLES UNDER HOOD FUSIBLE LINKS FOR AUTOMATIC MEANS OF TO SHUT DOWN UPON EIRE SYSTEM ACTUATION PER NEPA 17A ACTIVATION 3. SYSTEM TO HAVE AUDIBLE_ DEVICE TO 6- ALL MOTORS, LIGHTS AND OTHER SOUND UPON ACTUATION OF FIRE ELECTRICAL DEVICES INSTALLED IN TYPE I SUPPRESSION SYSTEM. (INSTALLED AND DUCTS OR HOODS OR LOCATED IN THE PATH PROVIDED BY ELECTRICIAN) OF TRAVEL OF EXHAUST PRODUCTS ARE SPECIFICALLY APPROVED FOR SUCH USE HOOD AND FANS OPERATIONS NOTES 1. SUPPLY AND EXHAUST FANS ARE INTERLOCKED "WITH PILOT LIGHTED SWITCH IN KITCHEN AREA, 2. FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN .STOPS. 3. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE FIRE EXTINGUISHING SYSTEM IS ACTIVATED (EVEN WHEN HOOD SWITCH IS IN OFF POSITION). 4. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL_ BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST. J 5. ALARM OR INDICATOR INTERCONNECTS WITH FIRE SYSTEM MICROSWITCH TO SOUND UPON ACTUATION OF FIRE SYSTEM TO BE PROVIDED AND INSTALLED BY OTHERS. (IF REQUIRED). 6. PENETRATIONS FOR PIPING AND CONDUITS TO HOOD WILL BE ACCOMPLISHED BY APPROVED UL. DEVICES OR WELDED. I C) Q� O OG`7Cs . _ REVISIONS NUMBER DESCRIPTION 770 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 JOSEPH POTTS, P, E. E -MAIL: HOODDE- POTOAOL. COM PHA' 800 - 322--8730 LICENSE j 22656 DATE A ERE EQUIPMENT 2759 19TH STREET POMPANO BEACH, FL L/�[GAfREDO ZANETT EXPRESSO 5800 SW 73RD ST SOUTH MIAMI, FL I N -- 2471 SCALE. • DRAWN BY,- CHECK BY: DATE. - NOTED M. C. R. 7, 10,/29/09 TITLE.- FIRE SUPPRESSION SYSTEM 1 OF 2