Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-589-031
SP ELECTRICAL NOTES: I. EXISTING ELECTRICAL METER AND MAIN PANEL SEE SITE PLAN FOR LOCATION 2. MAXIMUM NUMBER OF OUTLETS PER CIRCUIT SHALL COMPLY WITH F.B.C. 2004). J. OUTSIDE RECEPTACLES, SHALL BE G.F.I. 4. ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L. 6. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW MASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITABLE AREAS. LOCATION: VOLTAGE: 1201240V, 3P, 4W MOUNTING: SURFACE EXISTING PANEL "A" rn � V) o o < o N �N REMARKS ® QUADRUPLE RECEPTACLE EXISTING CU(NON COINCIDENT LOAD) J > x DUPLEX RECEPTACLE GROUND x FAULT INTERRUPTER 50 2 10000 314- 8 EXISTING AHU 1 91 G.L.(INTERIOR LIGHT) 12 Q WALL MOUNTED FIXTURE 1 3 20 1 * 112" 12 G.L.EXTERIOR LIGHT 5 20 1 * 112" 12 G.L.BATH,STORE 7 14 RECEP. WATER COOLER 12 112" * SPACE 9 20 1 * 1/2" 1 540 RECEPTACLE 11 1 e, RECEPT. GFI OIL PUMP 12 3/4" 1 540 1 13 20 RECEPT. GFI OIL PUMP) 12 3/4" r12 ROTARY LIFT 20 25 3 4800 314" S ACE.SEE SP 15 FORPARKING I FT 1 G SPACE SEE SP 21 TION ELECTRICAL SYMBOL LEGEND: MAIN BUS: 125 A NEUTRAL: 125A MAIN: MLO Al C: 22,000 o Y U TOGGLE SWITCH (36" A.F.F.) �N >y� THREE —WAY TOGGLE SWITCH ( +36" A.F.F.) << O> DUPLEX RECEPTACLE ( +18" A.F.F.) ® QUADRUPLE RECEPTACLE EXISTING CU(NON COINCIDENT LOAD) EXHAUST FAN x DUPLEX RECEPTACLE GROUND x FAULT INTERRUPTER '> FLUORESCENT FIXTURE 12 COMPUTER HARDWARE BOX * PHONE & SATELITE OTELEVISION 91 G.L.(INTERIOR LIGHT) 12 Q WALL MOUNTED FIXTURE 1 RECESSED CEILING FIXTURE MAIN BUS: 125 A NEUTRAL: 125A MAIN: MLO Al C: 22,000 o Y U REMARKS �N >y� oN UCn << O> � � a � Cn 2 4 EXISTING CU(NON COINCIDENT LOAD) 10 3/4" LOAD 2 40 '> GEN. LIGHTING(SIGN) 12 112" * 1 20 91 G.L.(INTERIOR LIGHT) 12 112.. * 1 20 10 RECEPTACLE 12 112" * 1 20 12 RECEPTACLE 12 112" * 1 20 14 RECEP. WATER COOLER 12 112" * 1 20 16 EXTERIOR RECEPT. GFI 12 3/4" 1 540 1 20 1 e, RECEPT. GFI OIL PUMP 12 3/4" 1 540 1 20 20 RECEPT. GFI OIL PUMP) 12 3/4" 540 1 20 SPACE SPACE LOAD CALCULATION 632.92 SQF f 3VA/SQF x 125 7 = 2,374 VA A/C LOAD 41007 = 10,000 VA OTHER LOAD 01007 = 11,220 VA TOTAL LOAD = 23,594 VA 1360 =66 AMPS 3" PVC SCHED(80) RGC TO POWER COMPANY TRANSFER PAD 41-1 EXISTING METER M 400 1#0 TW CU IN 314" COND. TO CWP. (UNDERGROUND) 1 #4 CONDUCTOR TO 20 FOOT SECTION OF FOUNDATION STEEL SP= SEE SITE PLAN FOR LOCATION OF PARKING SPACE * = PART OF THE 3 VA/SQF SERVICE: SEE RISER E EXISTING N NEW ❑-a DISCONNECT SWITCH © ELECTRIC PANEL MC1 ELECTRIC METER Q RED EXIT SIGN AND /0 EMERGENCY LIGHT '> COMBO UNIT O W/ BATTERY BACK —UP EXISTING MAIN CONNECT AHEAD OF SILL (40 CIRC) MODEL LHQM S W 1 R LU RED EXIT SIGN 200 W/ BATTERY BACK —UP MLO CONNECT AHEAD OF SILL � � °o MODEL LHQM S W 1 R WEATHER PROOF JUNCTION e0X WITH GFI RECEPTAI,LE SP E-0 SP S P FLOOR EXTERIOR RECEPTACLE DETAIL SEE SITE PLAN FOR LOCATION N TS I I I I I I I I I I I I EXISTING FLAT ROOF TO REMAIN I I I I I I I I I I I I EXISTING A/C COMPRESSORS TO REMAIN (3 TONS.) I II I I I I L.----- - - - - -- - - - - -TI FT- -FT- - - --FT- T� -- ------ - - - --i L-- - - - - -- EXISTING ELECTRICAL RISER MLO EXISTING 3 X THW EXISTING EXISTING C PANEL MLO S.N. H 1 4 4 THW CU. . 200 AMP. ELECT. 3 # 1 THW CU. Q 3 # 1 THW CU. /0 2" COND. PANEL MLO S.N. 1 # 4 THW CU. O oM EXISTING MAIN z (40 CIRC) -2" COND. LU � o: 200 w 0 LL N u MLO MLO EXISTING � � °o /<I^ vJ w Q �w 125 AMP. ELECT. 1l PNL PNL PANEL MLO S.N. T 125 �U A B (24 CIRC) Z OPT. NEW UJ 200 125 D O EXISTING ELECTRICAL RISER MLO NEW PNL 125 AMP. ELECT. C PANEL MLO S.N. H (2.4 CIRC) 125 NEW Q 3 # 1 THW CU. /0 1 # 4 THW CU. I 2" COND. HOUSE CONCRETE FOUNDATION # 5 FOUNDATION REBAR #4 MIN. 20 FT. LONG N.T.S. FPL MAXIMUM AT METER = USE 22,000 A.I.C. MINIMUM AVAILABLE: AT LOADCENTER = USE 22,000 A.I.C. MINIMUM 26,194 A.I.C. SEE CALCULATIONS F.P.L. AKS MINIMUM 18,630 EXISTING FLAT CONCRETE CANOPY 2 /E� TO REMAIN r X11 1 T X11 5' -E" HGT WATER UI FOR TV COOLER _ _ 1 L _ _ — — �a ' ® 12 \ 12 CUSTOMER WAITING AREA I I j TOTAL AREA:632.92 SF 4�8 NEW ELECTRIC PANEL �. � I 3 10 8 11110 11 07 NEW BATHR00 NEW /FOR SIGNLIJ j 7' -6 "Hgt 6 EXISTING \ — �. EX1STfNG ,� -- EXISTING 5 5 �. —.� 5 ELECTRICAL PLAN 1 /4"= 1 ' .0 '001p %3 r ^� `ty1; j t1�r NO\ STORAGE 1 n '0.4" EF THRU WALL W/ BACKDRAFT DAMPER di: BIRDSCREEN (NEW) Z.ii � �y .4 117 �a6mamu6oa Pa0G9��m� �aa���06G1a P.E. No 53288 Jose Antonio Mendez. Professional Engineer R] poo�aa�uomoa 1385 Coral Way Suite #203 Miami, FL 33145 161 `} CONCEPT D E SIG N S T U D 1 0 ANA MARIA BEEBE DESIGN CONSULTANT 10773 NW 58TH ST, #115 MIAMI, FL 33178 TEL. (786)367.1371 ABEEBE ©CDESIGNSTUDIO.NET �n Z Lp z Z :30 UZ n ' 00 Z d 0 1 Z UN N 0 w H 1 Q L6 /0 LL ❑ N O oM z 0 LU � o: ' < w 0 LL N u It � � °o /<I^ vJ w Q �w cn Q Q 2w �U Z li UJ LL D O L,_ �n Z Lp z Z :30 UZ n ' 00 Z d 0 1 O UN N W w H 1 L6 /0 LL ❑ N oM °o 0 N � o: ' < w 0 LL N u � J � � °o /<I^ vJ t o N c7 Signed and Sealed by. GABRIEL SALAZAR AR # 0009297 l Job No 09 -004 Project Manager AMB Drawn by AMR Scale AS INDICATED Datf: FEB 2009 SHE