09-589-013PROVIDE I HR. RATED PARTITION ON TOP OF EXI5TING WALL (SEE — SEGTION "G) SHEET A -4.10 CA PROPOSED ELECT. PANEL EXISTING AHU TO BE -- O i cv EXISTING ELEGTRIGAL BODY SHOP PANEL TO REMAIN AT E OTHER END OF BODY EXISTING TO REMAIN SHOP (SEE SP -2) n EXISTING 3'x6-10" OPENING EXISTING FIXED GLASS TO REMAIN. PROVIDE A IND n/W (45MIN.)Tg D 45MIN. RATED METAL OO W/ SELF CLOSING OVIDE ELEGTRI TER GOOLER 8' -Q 13/16 I/4" 5' -10 5/8" ,10' -q 7/8" I E!HE41 I I I I I I I I I I I I I LII 1 1111 H I I I EXISTING 3'x6' -8" 001 F� N ALUM /GLASS DOOR A AND PARTIALLY BUSINESS REP. AREA r - --I STOREFRONT TO ` REMAIN ♦ n �n n 1= I ♦ I I/2" L ♦ BST M G ♦ 02 1 / ; 2' -10° 4" ; CUSTOMER WAITING AREA I I I II APEA:632.92SF TOP OF 101 E I I 1 I -- CJ FINISH FLOOR EXISTING ~► ( \1 ( 1 ( l ( \1 i - L °4nnUn NI N �\ 17-KI REPLACE EXISTING WINDOW BY A N 1� Ls [G GMU. PROVIDE � "1 GYP BOARD ON A 1 "X2" PT. FURRING OR MTL _ E5,1 13' -q 13/16" 12'- 3'-O" CHANNEL o 16 "O.G. (INCLUDE R -4.1 INSULATION INTO IFURRING 5PAGE) \ PROVIDE_ _SA_M_E_GONSTRUGTION - - - - -- --------------------------------------- --- - - - - -- SYSTEM AT BATHROOM WINDOW. GONGRETE SIDEWALK TO GONNEGT TO EXISTING SIDEWALK PROVIDE PLANTER ANCHORED PROVIDE WALL OPENING TO TO THE CONCRETE RECEIVE NEW STOREFRONT AND SWING DOOR. REMOVE — - - - - EXISTING WINDOW. - EXISTING CATCH BASIN TO REMAIN EXISTING CONCRETE CANOPY TO REMAIN. PROVIDE G.M.0 WALL WITH :2 GYP BOARD ON "X2" PT. FURRING OR MTL CHANNEL o 16 "O.G. (INCLUDE R -4.1 INSULATION INTO FURRING 5PAGE) ON THE INTERIOR AND PAINTED STUGGO ON THE \ EXTERIOR EXISTING DELOUSE WINDOW TO REMAIN SLOPE- AREA OUTSIDE \ THE DOOR AT 2% TO REACH NEW FINISH �LOOR JQ ti 1 -t\v Nil I I ' Q STORAGE 103 I I �I 13116" SEE 5HEI�T A -5.1 EXISTING PARKING AREA TO REMAIN (II PARKING SPACES TOTAL) PROVIDE NEW GONGRETE GOAT ON TOP OF EXISTING ASPHALT AND NEW PARKING STRIPING AS INDICATED ON SHEET 5P -2 (G.G. TO PROVIDE PROPER SLOPES AND DRAINAGE) A/G WALL UNIT OPENING TO BE FILLED. PROVIDE PAINTED 5TUGG0 FINISH STRIPING AREA TO BE RESURFACED (SLOPE 2% MAX) — PROVIDE BATHRO EXH. GAP J n. EXISTING 6 HIGH IRON - FENCE TO BE RELOCATED S EXISTING GREEN AREA TO REMAIN EXISTING METRO -RAIL ---------------------------------- - - - - -- TRACK PROJECTION EXISTING METRO -RAIL GONGRETE STRUCTURE U.S SOUTH FEDERAL NWY I I I I I I I I I I I I EXISTING FLAT ROOF TO REMAIN I I I I I I I I I I I I I L------------------------ EXIT SIGN. (� - - - -Fi a AND EXIT SIGN PROVIDE GRILLE FOR EXISTING FLAT CONCRETE A/G FRESH AIR GANOPY TO REMAIN PAPT I AL POOF PLAN I I I I I I I i I I EXISTING A/G GOMPRE5SOR5 TO I I REMAIN (3 TONS.) I I I I I I I I I - - -- -- - - - -J L--- - - - - -- FLOOR FLAN LEGEND: [^] WALL HUNG LAVATORY [B] TILT -IN MIRROR WALL MOUNTED GRAB BARS [5] CUSTOM -MADE WORK STATION NTEF I OR FINISHES FLAME SFRE-AL_,) CLASS I F I �ATI ON EXISTING INTERIOR FINISHES TO REMAIN AS P0551BLE * VYNIL FLOORING * PAINTED WALLS * VYNIL BASE BOARD * GYPSUM BOARD GEILING * TILE IN BATHROOM AS PER TABLE 803.5 PROVIDE GLASS "B" FOR EXITWAY5 AND GLASS "G" FOR ROOMS AND ENGLO5ED 5PAGE5. PROVIDE 6" CONTINUOUS GONGRETE CURB PROVIDE ACCESSIBLE PARKING STALL SIGNAGE ( SEE DTL ON SHEET 5P -2) — EXISTING LAND5GAF TO BE RELOCATED ONCE PENCE IS MO\, EXISTING LANDSGA TO REMAIN WALL 5YMF30L LECEN:�) : GENERAL NOTES: I. PROVIDE 2X1 WOOD BACKING AT BATHROOM AND OTHER CABINETRY. (SEE DTL o SHEET A -5.10 2. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOGKED DOOR FROM THE OUTSIDE IN AN AN EMERGENCY. (NFPA- 21.2.4.4) 5. SURROUNDING MATERIALS (SECTION 1210) 1210.1 FLOORS. IN OTHER THAN DWELLING UNITS, TOILET AND BATHING ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NON - ABSORBENT SURFACE THAT EXTENDS UPWARD ONTO THE WALLS AT LEAST 6 INCHES. 1210.2 WALLS. WALLS WITHIN 2 FEET OF URINALS AND WATER GL05ET5 SHALL HAVE A NON - ABSORBENT SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND EXGEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE 15 NOT ADVER5ALY AFFEGTED BY MOISTURE. ACGE550RIE5 5UGH A GRAB BARS, TOWEL BARS, PAPER DI5PEN5ER5 AND SOAP DISHES, PROVIDED ON OR WITHIN WALLS, SHALL BE INSTALLED AND SEALED TO PROTECT STRUCTURAL ELEMENTS FROM MOISTURE. 4. ALL EXTERIOR GLAZED OPENINGS TO BE PROTECTED WITH APPROVED STORM SHUTTERS, 5. TERMITE STATEMENT: ALL BUILDINGS SHALL HAVE PRE- GONSTRUGTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES. A GERTIFIGATE OF COMPLIANCE SHALL BE 155UED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN AGGORDANGE WITH THE RULES AND LAWS ESTABLISHED BT' THE FLORIDA DEPARTMENT OF AGRICULTURE AND GONSUMER SERVICES." OL1 -l�L EXISTING 8" GONG. BLOCK WALL W /STUCCO CO NEW DOOR DESIGNAT ON ONEW 8" GONG. BLOCK WALL W /STUCCO U NEW WINDOW DESIGNATION 12'1 ! 77 +�•'� ./ REFER TO NEW FLOOR PLAN LEGEND OC NEW NON -RATED 3 5/8" MTL. STUD PARTITION EA DESIGNATION (SEE DTL I /A -6.1) 110 REFER TO NEW ROOM DESIGNATION SHEET 1 REFER TO NEW ROOM INTERIOR ELEVATION T' DESIGNATION (SEE ID. DWGS) EXISTING AREA TO REMAIN WITHOUT ANY MODIFICATION LIFE SAFETY LEGEND - - - - - PATH OF TRAVEL NOTE: * SEE LABEL INDIGATING N =NEW OR R= RELOCATED OR TO BE RELOCATED * INSTALL PORTABLE FIRE EXTINGUISHER IN ACCORDANCE WITH NFPA 10. 1 EXISTING BUSINESS USE TO REMAIN IN BLDGS. UNPROTECTED WITH AN AUTOMATIC- 5PRINKLER SYSTEM * GOMMON PATH OF TRAVEL ALLOWED: 75' -O" (NFPA. 38.2.5.3.1) PROVIDED: (AS 5HOWN) < 75-0" * MAX. TRAVEL D15TANGE ALLOWED: 200' -0" (NFPA. 38.2.6.1) PROVIDED: INDICATED < 200' -0" * MAX. DEAD END ALLOWED 50' -0" (NFPA. 38.2.5.2.1) OR 20' -0" (FBG2007) PROVIDED: N/A < 50'- 0"/20' -0" FLOOQ PLAN G CONCEPT D E SIG N S T U D 1 0 ANA MARIA BEEBE DESIGN CONSULTANT 10773 NW 58-1-H ST,#115 MIAMI, FL 33178 TEL. (786)367.1371 ABEEBE @CDESIGNSTUDIO.NE � REVISIONS- BY� /1\ FIRE DEPT COMMENTS 7 -21 -09 AMB EXIT SIGN. (� EMERGENCY LI6HT5. BATTERY BACKUP a AND EXIT SIGN FE ABC- PORTABLE FIRE EXTINGUISHER NOTE: * SEE LABEL INDIGATING N =NEW OR R= RELOCATED OR TO BE RELOCATED * INSTALL PORTABLE FIRE EXTINGUISHER IN ACCORDANCE WITH NFPA 10. 1 EXISTING BUSINESS USE TO REMAIN IN BLDGS. UNPROTECTED WITH AN AUTOMATIC- 5PRINKLER SYSTEM * GOMMON PATH OF TRAVEL ALLOWED: 75' -O" (NFPA. 38.2.5.3.1) PROVIDED: (AS 5HOWN) < 75-0" * MAX. TRAVEL D15TANGE ALLOWED: 200' -0" (NFPA. 38.2.6.1) PROVIDED: INDICATED < 200' -0" * MAX. DEAD END ALLOWED 50' -0" (NFPA. 38.2.5.2.1) OR 20' -0" (FBG2007) PROVIDED: N/A < 50'- 0"/20' -0" FLOOQ PLAN G CONCEPT D E SIG N S T U D 1 0 ANA MARIA BEEBE DESIGN CONSULTANT 10773 NW 58-1-H ST,#115 MIAMI, FL 33178 TEL. (786)367.1371 ABEEBE @CDESIGNSTUDIO.NE � REVISIONS- BY� /1\ FIRE DEPT COMMENTS 7 -21 -09 AMB Job No 01 -004 Project Manager AMB Drown by - -- -- AMB. -- -- Scale AS INDICATED Date FEB 200q SHEET No. A 2.1 z a z Z Q O Q J d a In 0 z V z W Q c7 � m ui ui rn V ? 11 nF" S uj v X Q Q n 0/ LL Z W �- O "- > W OQ to c Q Job No 01 -004 Project Manager AMB Drown by - -- -- AMB. -- -- Scale AS INDICATED Date FEB 200q SHEET No. A 2.1 � � z Z O Q J d .�� In 0 V z Q c7 � m +� ? 11 nF" o U" c� W W F- I � U W E C o� (� o t < ¢ u w o N Q � , n Signed and Sealed by: GABRIEL SALAZAR AR # 0009297 I i r r. I� Job No 01 -004 Project Manager AMB Drown by - -- -- AMB. -- -- Scale AS INDICATED Date FEB 200q SHEET No. A 2.1