Loading...
09-589-011PROVIDE I HR. RATED PARTITION ON TOP OF EXISTING WALL (SEE SECTION "G) SHEET A -4.10 t PROPOSED ELECT. PANEL EXISTING AHU 'TO BE ENCLOSED N U N EXISTING ELECTRICAL BODY SI -IOP/ PANEL TO REMAIN AT / OTHER END OF BODY EXISTING TO REMAIN SHOP (SEE SP -2) EXISTING 3'x6' -10" OPENING EXISTING FIXED TO REMAIN. PROVIDE A WINDOWS (45MIP 45MIN. RATED METAL W/ SELF 5' -1 13/16" 5' -10 5/8' PROVIDE ELECTRIC WATER COOLER IIQi� EXISTING CONCRETE CANOPY TO REMAIN. I I I I I ~ __ �L_I L_LL L. _J EXISTING 3'x6' -8" Cp� FEN _ ALUM /GLASS DOOR AND PARTIALLY PROVIDE G.M.0 WALL WITH" GYP BUSINESS REP. Af�EA r - -- - - � STOREFRONT TO ♦ REMAIN BOARD ON 4 "X2" PT. FURRING OR ♦ �� o =� 17 1 MTL CHANNEL co) 16 "O.C. (INCLUDE �l r1 R -4.1 INSULATION INTO FURRING ♦ I I I I_ ♦ 5PAGE) ON THE INTERIOR AND ♦ -� = '�- -- �� PAINTED STUGGO ON THE ♦ 1 0 1/.2 EXTERIOR \ ♦ L (� _---- - - - - -- EXISTING DELOUSE -- N WINDOW TO REMAIN. ♦ O; D 2 / \\ SLOPE AREA OUTSIDE THE DOOR AT 2% TO ♦ 3 x--4.1 -- REACH NEW FINISH \ ♦ ' LOOR 2' -l0" 4" ♦ CUSTOMEQ WAITING APEA _ AREA:63292 SF -� _ _ � 5. J 1 TOP OF 101 1 r Cps ,h FINISH FLOOR _ , - _ -- -- + -- B I� STOPAGE - �r EXISTINE O4 103 �( C> U U U _LC[ _ — L - - =ILC - REPLAGE EXISTING WINDOW BY A N A 1\ B G t -\ ✓� - - -- = - - -Z \. o - �O GMU. PROVIDE "GYP BOARD ON - �' X2" PT. FURRING OR MTL 13 9 13/16 12'- 3' -O' 6' 4' 8" 8' -11 15/16" CHANNEL c-I Ib "O.G. (INCLUDE R -4.1 - - �- -- all - \ INSULATION INTO FURRING SPACE) -- - ' ✓�� - -__ , PROVIDE_ SAME GONSTRUGTION SYSTEM AT BATHROOM WINDOW. - - -- - - - - - -- - - - - - -- - - -- - - - - - -- - - - - - -- - --- - - - - -- - - - - -- _ SEC SHE T A -5.1 \ CONCRETE SIDEWALK TO GONNEGT TO EXISTING SIDEWALK PROVIDE PLANTER ANCHORED �- PROVIDE WALL OPENING TO TO THE CONCRETE REGEIVE NEW STOREFRONT 0 AND SWING DOOR. REMOVE - - - - - EXISTING WINDOW. -- - -_ Z EXISTINO'GATGH BASIN TO REMAIN PROVIDE B:^ EXH. GAP EXISTING b' HIGH IRON - -� FENCE TO BE RELOCATED - - -- EXISTING GREEN AREA - -- - TO REMAIN �y EXISTING PARKING AREA TO REMAIN (II PARKING SPACES TOTAL) PROVIDE NEW CONCRETE GOAT ON TOP OF EXISTING ASPHALT AND NEW PARKING STRIPING AS INDIGATED ON SHEET 5P -2 (G.G. TO PROVIDE PROPER 5LOPE5 AND DRAINAGE) A/C WALL UNIT OPENING TO BE FILLED. PROVIDE PAINTED STUCCO FINISH 5TRIPING AREA TO BE RE5URFAGED (SLOPE 2% MAX) PROVIDE 6" CONTINUOUS GONC.R -TE CURB -- . PROVIDE ACCESSIBLE PARKING STALL SIGNA6E ( SEE DTL ON SHEET 5P -2) �'l OOF-P, FLAN LEGEND: WALL HUNG LAVATORY TILT -IN MIRROR WALL MOUNTED GRAB BARS LD] CUSTOM -MADE WORK STATION NTEF,I OR F 1 N I SHE-S FL/�ME SFREAD CLASSIFICATION EXISTING INTERIOR FINISHES TO REMAIN AS POSSIBLE: VYNIL FLOORING PAINTED WALLS * VYNIL BASE BOARD GYPSUM BOARD GEILIN6 * TILE- IN BATHROOM AS PER TABLE 805.5 PROVIDE GLASS "B" FOR EXITWAYS AND GLASS "G" FOR ROOMS AND ENCLOSED SPACES. - -J _7 �w _�ss < j' CJ C l / �- -- EXISTING LANDSGAF TO BE RELOCATED ONCE FENCE 15 MOB -- - EXISTING LANDSGA TO REMAIN EXISTING METRO -RAIL - -- - - - - - TRACK PROJECTION \ - ----------------------- - - - - -- --------------------- - - - - -- - - - - - -- - - -- - - -- ---- - - - --- - - -- -- - - -- U.S SOUTH EEDEQAL HWY I I I I 1 I I I I I I I I EXISTING FLAT ROOF TO REMAIN 11 I I I I 1 � I I I I I I z O II IPROVIDE GRILLE FOR A/C FRESH AIR PAQT I AL POOP PLAN I I I I I I I EXISTING A/C, COMPRESSORS TO I I REMAIN (5 TONS.) I I I I I I I FF - rF — — — — ,� - LI - -1 L LL _ Ll_ — -- -- - - - -- -- EXISTING FLAT GONGRE-TE = CANOPY TO REMAIN ^ALL I$ 5YME50L LE (5ENE�: O- ENERAL NOTES: I PROVIDE 2X1 WOOD BACKING AT BATHROOM AND OTHER CABINETRY. (SEE DTL * SHEET A -5.0 2. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN AN EMERGENCY. (NFPA- 21.2.4.4) E3. SURROUNDING MATERIALS (SECTION 1210) 210.1 FLOORS. IN OTHER THAN DWELLING UNITS, TOILET AND BATHING ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NON - ABSORBENT 5URFAGE THAT EXTENDS UPWARD ONTO THE WALLS AT LEAST b INCHES. 1210.2 WALL5. WALLS WITHIN 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A NON - ABSORBENT SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE 15 NOT ADVERSALY AFFECTED BY MOISTURE. ACCESSORIES SUCH A GRAB BARS, TOWEL BARS, PAPER DISPENSERS AND SOAP DISHES, PROVIDED ON OR WITHIN WALLS, SHALL BE INSTALLED AND SEALED TO PROTECT STRUCTURAL ELEMENTS FROM MOISTURE. 4. ALL EXTERIOR GLAZED OPENINGS TO BE PROTECTED WITH APPROVED STORM SHUTTERS. 5. TERMITE STATEMENT: ALL BUILDINGS SHALL HAVE PRE- GONSTRUGTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES. A CERTIFIGATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT GONTAINS THE FOLLOWING STATEMENT: THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT 15 IN AGGORDANGE WITH THE RULES AND LAW5 ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRIGULTURE AND CONSUMER SERVICES." DE VAL Lsyos ,{ Yµ 1t C000 - � A 111 LifE 5AF r'{ HOC► ,'�rl`�.�p' •�� �� L �� I EXISTING 8" GONG. BLOCK WALL W/STUGGO CU l NEW DOOR DESIGNATION NEW 8" GONG. BLOCK WALL W /STUCCO �J NEW WINDOW DESIGNATION NEW NON -RATED 3 5/8" MTL. STUD PARTITION —� A REFER TO NEW FLOOR PLAN LEGEND \,✓ DESIGNATION (SEE DTL I/A -6.0 REFER TO NEW ROOM EXISTING AREA TO REMAIN WITHOUT ANY MODIFICATION LIFE SAFETY LEGEND - - - - - PATH OF TRAVEL. EXIT SIGN. I ' EMERGENCY LIGHTS. BATTERY BACKUP AND EXIT SIGN ABC, PORTABLE FIRE EX7ING1JI51HER NOTE_ SEE LABEL INDIGATING N =NEW OR R= RELOCATED OR TO BE RELOCATED * INSTALL PORTABLE FIRE EXTINGUISHER IN ACCORDANCE WITH NFPA 10. L__L NO�_'TH A J DESIGNATION SHEET > REFER TO NEW ROOM INTERIOR ELEVATION T' DESIGNATION (SEE ID. DWGS) EXISTING BUSINESS USE TO REMAIN IN BLDGS. UNPROTECTED WITH AN AUTOMATIC, SPRINKLER SYSTEM " COMMON PATH OF TRAVEL ALLOWED: 75' -0" (NFPA. 3x.2.5.33) PROVIDED: (AS SHOWN) < 75' -0" ' COMMON PATH OF TRAVEL SHALL NOT BE LIMITED IN A SINGLE TENANT SPACE WITH AN OCCUPANT LOAD NOT EXCEEDING 30 PEOPLE (NFPA. 5' 1.253.2) MAX. TRAVEL DI5TANGE ALLOWED: 200' -0" (NFPA. 3- 1.26.2) PROVIDED: INDICATED < 200' -0" * MAX. DEAD END ALLOWED 50' -0" (NFPA. 3- 1.2.5.2) OR 20' -0" (FBG2007) PROVIDED: 16' -0" < 50'- 0720' -0" FLOO�,' PLAN REVISIONS — BY j j FIRE DEBT COMMENTS 7--21 -09 PAD 3 FIRE DEP1 COMMENTS 10 -31 -09 AMI3 G CONCEPT D E SIG N S T U D 1 0 ANA MARIA BEEBE DESIGN CONSULTANT 10773 NW 58TH ST,#115 MIAMI, FL 33178 TEL. (786)367.1371 ABEEBE @CDESIGNSTUDIO.NE_ � -- �� T. Job No oa -oo4 _ Project Manager AYE Drawn by AMB - -- c c a I e AS INDICATED � — — __ - - -- Date FEB 200Q -- SHEET No. I A-/1 I 1 i z O U 0 z Z CVO 0 Q 0 z W V z W Q �W Q) m J � uj ->_ 111 U D Z LL S CY ° W LL �. LC) lif) G CONCEPT D E SIG N S T U D 1 0 ANA MARIA BEEBE DESIGN CONSULTANT 10773 NW 58TH ST,#115 MIAMI, FL 33178 TEL. (786)367.1371 ABEEBE @CDESIGNSTUDIO.NE_ � -- �� T. Job No oa -oo4 _ Project Manager AYE Drawn by AMB - -- c c a I e AS INDICATED � — — __ - - -- Date FEB 200Q -- SHEET No. I A-/1 I 1 i O�tttt � O U z Z CVO �0) Q 0 Q V z Q Q) m J 4-1 D � U W H w - I r- ' �W Q C" -, Q ri ,`.' 7 '1 Q y Q c' =` ; c� :rt- r' 11y - -_ - -- Signed and Sealed by: #�;•;' t�-- ;'..l. GABRIEL SALAZAR AR #0009297 UL;A G CONCEPT D E SIG N S T U D 1 0 ANA MARIA BEEBE DESIGN CONSULTANT 10773 NW 58TH ST,#115 MIAMI, FL 33178 TEL. (786)367.1371 ABEEBE @CDESIGNSTUDIO.NE_ � -- �� T. Job No oa -oo4 _ Project Manager AYE Drawn by AMB - -- c c a I e AS INDICATED � — — __ - - -- Date FEB 200Q -- SHEET No. I A-/1 I 1 i