09-589-001Department of Environmental Resources Management Plan Review Services Division 11305 SW 26th Street Suite 124 MIAMI•DADE Miami, Florida 33175-2464 T 736- 315 -2 800 F 736- 315 -2921 miamidade. =ov Paving and Drainage Plan Review —� Date: 11/24/09 Project Name: Dent Master Address: 5795 S. Dixie Hwy., South Miami Review Engineer: Bill Gallo Proximity Info DERM Process No.: M2009007185 Folio Number #: 0940250281091 Section - "township -Range Wetland Area of Concern Location within WPA N/A N/A Flood Info 25 -54 -40 Contamination N/A Dade County Flood Criteria (N.G.V.D.) October Water Elevation (N.G.V.D.) Average Crown of Road (N.G.V.D.) 6.4 3.0 9.09 Permit Info ERP /General Permit X N/A Cut & Fill Approval li N/A Class 11 /III /VI Permit N Tentative Plat * N/A STOMWATER DRAINAGE SYSTEM SPECIFICA'T'IONS N/A 1. Catch Batch Rim Elevation (ft) 8.75 N.G.V.D. 2. Catch Basin Type ❑ Type P ❑ Type J ® Othcr 3. French Drain Length Proposed (L.F.) 90 4. Pipe Invert Elevation (ft) 3.0 N.G.V.D. REQUIREMENTS: • Compliance with Sections 24.12.1, 24.12.2 of Miami -Dade County Code / Aquifer Protection Requirement • Oil & Grease Interceptors at all Catch Basins preceding French Drains, as per STD Details (on reverse) • Oil & Grease Interceptors at Structures Nos. • All French Drains shall have perforated pipe invert elevation at a minimum of the Average October Groundwater Level 3.0 N.G.V.D. or higher. ® Property site shall be graded to provide total on -site stormwater retention. Drainage calculations and percolation test to show full onsite retention of the 5 -year, I -day storm. COMMENTS: 1. French Drain shall be as per SD l .1 or SD 1.1 (modified) 2. Catch Basin shall be as per SD 2.2, 2.6 or larger, with baffles preceding all French Drains 3. Site's property lines shall be graded to indicate that stormwater does not runoff to adjacent properties. 4. French Drain serving covered parking garages shall be as per SD 1.1 modified or preceded by an oil a c�greae trap — 5. No built -up structure shall be constructed over or upon an approved Drainage System. 1 I 6. Deviations from approved design shall be submitted to Plan Review's P & D Section for reapproval. 7. All French Drain lengths, widths, and depths shall be a minimum of 25 ft, 3 ft, and 15 ft respectivcl The length may be 15 feet provided that it provides twice the minimum required length for full onset leterftion 9. Stormwater Drainage system shall not be installed in a Contaminant Plume. - Paae 1 of