13-510-005i' (a) (a) 120/240V PANEL "A11 150 M.L.O. 1 PH,3W SURFACE MTD BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A COVERED TERR. #14 -1/2 "C * 1P -15 1 2 1P -20 1500 #12 -1/2 "C DINING REC. BEDROOM 6 RECEPTACLES 1500 900 #12 -1/2 "C 3 3 4 4500 1800 1500 BATH REC ON TIMER APPLIANCES BEDROOM 1P-20 600 5 6 GFI 11.12 5 6 BATH REC 1500 * SPACE APPLIANCES L. ROOM 8 FAN OJ FAN AND LIGHT(3 -WIRE CKT) SPACE WHIRPOOL 7 8 1500 TOTAL 1500 9 10 REFRIGERATOR FRONT PORCH 2#8 -3/4 "C W.H. No.2 BEDROOM #14 -1/2 "C * 1P -15 9 10 40 3000 1200 DISHWASHER BATH * 13 14 11 12 #14-1/2"C STAIRS /CORR. 800 G. DISPOSAL ENTRY 15 16 * 13 14 MASTER BED 1500 if MICROWAVE DINING 18 SPACE 15 16 2P 3000 2#8, 1 #10 OVEN KITCHEN 19 20 17 18 40 3000 1 910 GRD -3/4 "C FAMILY ROOM 21 22 19 20 2P 2000 3 #10 -1/2 "C DRYER FAMILY ROOM * 23 24 21 22 30 2000 BATH MAIDS * 25 23 24 2P 4500 2#8 -314 "C AHU 1 BATH REC. #12 -1 /2 "C 1 P -20 25 26 50 4500 (8 KW) LAUNDRY SPARE 1500 1P -20 27 28 2P 13150 3#3, 1#6 PNL "P" WASHER 1500 1P -20 29 30 100 13150 GRD:11, -'C GARAGE 900 33 34 31 32 2P 3000 2#8 -3/4 "C W. HTR G.OPENER 35 600 33 34 40 3000 No.1 G.OPENER if 600 35 36 1P -20 900 39 SPARE SPACE 37 38 41 42 * 1600 S.F. 39 40 SUBTOTAL 9,300 TOTAL = 24,300 41 42 * 2000 S.F. 6000 SUBTOTAL 11,100 TOTAL = 61,400 50,300 SUBTOTAL (a) AFC( C/B A/C @ 100 % = 4200 HEAT @ 65% =5850 DEMAND LOAD = 52.4 KW FIRST10KW @100% = 10.0 KW 42.4 KW @ 40 % = 16.96 KW A/C = 5.85 KW 32.81 KW (137A) (a) 120/240V PANEL "B" 150 M.L.O. 1 PH,3W SURFACE MTD BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V•A V•A FLOODS #12 -1/2 "C 1500 1P -20 1 2 2P 4500 2#8 -3/4 "C AHU No-2 FLOODS 6 RECEPTACLES 1500 900 #12 -1/2 "C 3 4 50 4500 1800 (8 KW) BATH REC ON TIMER 9 * 1P-20 600 5 6 GFI 11.12 SPARE SPACE BATH REC SAFETY DISCONNECT SWITCH * SPACE O 7 8 FAN OJ FAN AND LIGHT(3 -WIRE CKT) SPACE WHIRPOOL GFI GROUND -FAULT INTERRUPTER 1500 TOTAL T 9 10 2P 3000 2#8 -3/4 "C W.H. No.2 BEDROOM #14 -1/2 "C * 1P -15 11 12 40 3000 * 13 14 1p-15 * #14-1/2"C STAIRS /CORR. * 15 16 * SITTING MASTER BED * 17 18 SPACE * 19 20 * 21 22 BATH * 23 24 BATH * 25 26 SPARE 27 28 SPARE 11 29 30 31 32 33 34 35 36 37 38 39 40 41 42 * 1600 S.F. 4800 SUBTOTAL 9,300 TOTAL = 24,300 15,000 SUBTOTAL (a) AFCI C/B DEMAND LOAD = 15.3 KW (b) ON TIMER A/C @ 100 % = 4200 (c) GFI HEAT @ 65% =7150 FIRST 10 KW @ 100 % = 10.0 KW 5.3 KW @40% = 2.12 KW A/C = 5.85 KW 17.97 KW (75A) GENERAL NOTES: THE COMPLETE SET OF CONSTRUCTION DOCUMENTS CONSISTS OF DRAWINGS, DETAILS 8 SPECIFICATIONS. IN THE EVENT OF A DISCREPANCY, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEERS FOR CLARIFICATION. ANY DEVIATION FROM THESE DRAWINGS, WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT AND /OR ENGINEERS IS PROHIBITED. GENERAL CONTRACTOR OR SUBCONTRACTORS ASSUMES FULL RESPONSIBILITY FOR ANY UNAUTHORIZED DEVIATION FROM THE INFORMATION DEPICTED IN THE CONSTRUCTION DOCUMENTS. ENGINEERS ARE NOT RESPONSIBLE OR LIABLE FOR ANY DISCREPANCY BETWEEN THESE DRAWINGS AND TPE EXISTING CONDITIONS. ANY WORK PERFORM ON THE PROPERTY PRIOR THESE CONSTRUCTION DOCUMENTS AND WILL NOT MATCH WITH THE INFORMATION IN THE EXISTING CONSTRUCTION DOCUMENTS ON CITY RECORDS OR IT WAS NOT VISIBLE AT TIME OF INSPECTION OR THE WORK WAS DONE ILLEGALLY WITHOUT PERMIT BY OTHERS AND WILL CAUSE A DISCREPANCY WITH THE NEW DRAWINGS IS THE RESPONSIBILITY OF THE CURRENT OWNER OF THE PROPERTY AT HIS OWN EXPENSE TO PERFORM ALL THE NECESSARY CORRECTIONS IN ORDER THAT ALL WORK IS IN ACCORDANCE WITH THE CURRENT FLORIDA BUILDING CODE AND THE LOCAL ORDNANCE AND WILL MATCH WITH THE NEW CONSTRUCTION DOCUMENTS FOR WHICH WORK WILL BE PERFORM. a) a) 120/240V PANEL IPI 100A M.L.O. 1 PH, 3W (W. PROOF) SURFACE MTD CKT. NO. DESCRIPTION C/B TRIP LOAD WIRE CONDUIT REMARKS 1,3 C.U. -1 2P -60 6000 2 #6 -3/4 "C �8 5,7 C.U. -2 2P -60 6000 2 #6 -3/4 "C ® 2,4 POOL PUMP 2P -25 2000 2 #10 -1/2 "C ON TIMER 6 RECEPTACLES 1P -20 900 #12 -1/2 "C FUSE OR DISCONNECT SWITCH 8,10 LANDSCAPE 1P-20 1800 © TELEVISION OUTLET ON TIMER 9 POOL LIGHT 1P-20 600 CHIME GFI 11.12 SPARE 1P-20 FOUR WAY TOGGLE SWITCH SAFETY DISCONNECT SWITCH 13 -18 SPACE O F FAN OJ FAN AND LIGHT(3 -WIRE CKT) FL GFI GROUND -FAULT INTERRUPTER WP TOTAL SD 17,300 (72A) CARBON MONOXIDE ALARM W /BATTERY ELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POKIER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO. AND ANW/EIA/TIA -510 4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN N M COM- PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS. 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION, AS REQUIRED. 1. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK THE NECESSARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI- NEER AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER 8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED N OTHER SECTIONS, ANY ADJACENT OR ABUTTNG WORK TO BE PERFORMED BY OTHERS. GAS GENERATOR OF (21 KW) PROVIDE MAIN GENERATOR RAER SEPARETELY NON- DERIVED SYSTEM 30350 MCM THWN ^O lCU) IN 21/2' G G d ` A NOTE SHALL BE P05TED AT TRANSFER SWITCH THAT ALL ELECT. 5REAKER5 SHALL BE TURN OFF PRIOR U51NG TRANSFER 5WITCH AND TURNING OF GENERATOR 30350 MCM THIN (CU) 2 -1/2'C NOTES: 1- MAINTAIN 2 FT. CLEAR HORIZONTALLY ON FIRE WALLS. 2- MAINTAIN 41/2 FT. CLEARANCE BETWEEN BOXES IN GARAGE CEILING. 3 -IN ALL AREAS SPECIFIED IN 210 -52 ALL 125V -15A AND 20A RECEPTACLES SHALL BE LISTED TAMPER - RESISTANCE RECEPTACLES. 4- PROVIDE ARC -FAULT PROTECTION PER NEC 210.12(8) .SEE PANEL SCHEDULES. 5- STAIRS ILLUMINATION SHALL COMPLY WITH FLORIDA RESIDENTIAL CODE 8303.6 (MIN. IFC) 3 MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERWISE INDICATED. LADE ITEMS SHALL BE THE PRO- DUCT OF A SINGLE MANUFACTURER 10. ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIT. WIRE SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER NEC ARTICLE 250 -122. 11. LOCATION OR OULETS IN ELECTRICAL DRAWNGS IS DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS. 13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE NON - AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. (COMPLY WMEC 110 -26) 14. ALL SMOKE DETECTORS TO BE NTERCOMNECTED ON SAME CKT (AFCI PROTECTED) 15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL a GROUNDING WIRE PER NEC ARTICLE 250 -140. NOTE: ALL EX15TING CONDITION5 5HALL BE VERIFIED AT FIELD BY CONTRACTOR EXIST. O METER 22K AIC 303/0 THLLN ,N6 GRID. (CU) - 2'C (CU) - 3/4'C 30350 MCM THWN (CU) 2 -1/2'C LOAD TABULATION DEMAND A/C PNL 'A' = 52A 525 PNL 'B" = 153 5.85 TOTAL = 61.1 ill SFER SLUITCH 120/24 Gv 0 FIRST 10 KW io 1000 100 ATEDTING 22K 51.1 KW 40% =2328 A/C 30350 MGM THWN (CU) 2 -1/2'C 8' x 8' 2 200 1 150 200 2 150 WP WP (22 ,000 A.I.G.) TYPICAL TOTAL - 44.18 KW (186A) PNL 31/0 T" ,1'(o (CU) - 2'C 303/0, 1% GRID THILN (CU) 2'C TO A CONCRETE ENCASED )E BOND TO A 3/4' COPPER 'E STUB OUT AND TO A 5/8'x10' 1- D ROD GLAD GROUND ROD (o- - ■j-�o CWP (METAL) 10 FT. LONG - BLDG. STEEL FOUNDATION RISER DIAGRAM NTS NOTE COMBINATION CARBON MONOXIDE ALARM AND SMOKE DETECTOR SHALL BENR LISTED OR LABELED COMPLY WITH NEC 210.12(5) SMOKE DETECTOR­, SWITCH SWITCH LEG F LINE SIDE 120V OF SWITCH , PHASE CONDUCTOR PNL PNL 5MCKE DETECTOR P CONNECTION DETAIL NTS. NOTES: -303 THWN ,1'6 GIRD. 1 -5MOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE) (CU) - 11/2'C WITH BATTERY BACK -UP AND SHALL BE CONNECTED TO A BEDROOM CIRCUIT PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED(AFCI PROTECTED) 2 -SMOKE DETECTOR SHALL BE LOCATED AT LEAST 3FT. FROM ANY A/C DIFUSER,BATHROOM DOORS AND WITHIN 20FT. OF COOKING APPLIANCE BE OF A PHOTOELECTRIC TYPE. 3 -THE MOUNTING AND LOCATION OF UNIT SMOKE DETECTORS SHALL COMPLY WITH NFPA 12 SEC2 -52.Ib . CEILING MOUNTS NOT LE55 THAN 4' FROM A WALL AND WALL MOUNTS AT LEAST 4' FROM CEILING AND NOT MORE THA 12' TO TOP OF DETECTOR NOT : 1- LOCATION OF THE GENERATOR EXHAUST SHALL BE LOCATED EXHAUST FANS, APPL ANCE VENTS, ETG IN ACGOIRDAN�DOORS I THE REQUIREMENTS OF THE FLORIDA RESIDENTIAL CODE, SECTION RIC7022 2 -0/A INTAKE SHALL BE MINIMUM 10 FEET HORIZONTAL DISTANCE FROM i ALL VENTS. 3- CAR50N MONOXIDE ALARM RECOMMENDED FOR SLEEPING AREAS. 3 -SLAB FOR GENERATOR SHALL BE ABOVE FLOOD LEVEL. :A - 1 HISTORY OF DRAWING ISSUED DESCRIPTION DATE OF ISSUED LEGEND LEGEND ® SPECIAL RECEPTACLE OUTLET DRAWING M.A.S. DUPLEX RECEPTACLE OUTLET 15A, 125V g- SIMPLEX RECEPTACLE OUTLET 15A, 125V O DUPLEX FLOOR RECEPTACLE, 15A, 125V EXHAUSTFAN �8 COMBINATION FAW LIGHT CEILING LIGHTING FIXTURE FLUORESCENT LIGHTING FIXTURE- SURFACE MTD. ® WALL MOUNTED LIGHTING FIXTURE F-O -i UNDER CABINET FLUORESCENT LIGHTING FIXTURE Q � FLOOD LIGHT 0 CEILING MOUNTED LIGHTING FIXTURE O LIGHTING PANEL �W/ FUSE OR DISCONNECT SWITCH 0 TELEPHONE OUTLET W� TELEPHONE OUTLET © TELEVISION OUTLET ❑O HI -HAT OPB PUSHBUTTON CHIME WALL SWITCH 15A, 1.25V $3 THREE WAY TOGGLE SWITCH $4 FOUR WAY TOGGLE SWITCH SAFETY DISCONNECT SWITCH O JUNCTION BOX O F FAN OJ FAN AND LIGHT(3 -WIRE CKT) FL GFI GROUND -FAULT INTERRUPTER WP WEATHERPROOF SD SMOKE DETECTOR O CARBON MONOXIDE ALARM W /BATTERY NOTE COMBINATION CARBON MONOXIDE ALARM AND SMOKE DETECTOR SHALL BENR LISTED OR LABELED COMPLY WITH NEC 210.12(5) SMOKE DETECTOR­, SWITCH SWITCH LEG F LINE SIDE 120V OF SWITCH , PHASE CONDUCTOR PNL PNL 5MCKE DETECTOR P CONNECTION DETAIL NTS. NOTES: -303 THWN ,1'6 GIRD. 1 -5MOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE) (CU) - 11/2'C WITH BATTERY BACK -UP AND SHALL BE CONNECTED TO A BEDROOM CIRCUIT PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED(AFCI PROTECTED) 2 -SMOKE DETECTOR SHALL BE LOCATED AT LEAST 3FT. FROM ANY A/C DIFUSER,BATHROOM DOORS AND WITHIN 20FT. OF COOKING APPLIANCE BE OF A PHOTOELECTRIC TYPE. 3 -THE MOUNTING AND LOCATION OF UNIT SMOKE DETECTORS SHALL COMPLY WITH NFPA 12 SEC2 -52.Ib . CEILING MOUNTS NOT LE55 THAN 4' FROM A WALL AND WALL MOUNTS AT LEAST 4' FROM CEILING AND NOT MORE THA 12' TO TOP OF DETECTOR NOT : 1- LOCATION OF THE GENERATOR EXHAUST SHALL BE LOCATED EXHAUST FANS, APPL ANCE VENTS, ETG IN ACGOIRDAN�DOORS I THE REQUIREMENTS OF THE FLORIDA RESIDENTIAL CODE, SECTION RIC7022 2 -0/A INTAKE SHALL BE MINIMUM 10 FEET HORIZONTAL DISTANCE FROM i ALL VENTS. 3- CAR50N MONOXIDE ALARM RECOMMENDED FOR SLEEPING AREAS. 3 -SLAB FOR GENERATOR SHALL BE ABOVE FLOOD LEVEL. :A - 1 HISTORY OF DRAWING ISSUED DESCRIPTION DATE OF ISSUED Q PROGRESS SCALE PERMIT DRAWING M.A.S. Q CONSTRUCTION REVISION BY SHEETS 3 �U ..J J II W "¢ U� W W W Lu Q � H �0N �W/ 0 co W� co n z co Lo r �" r. V O Z M C17 O Z LL V Z Q � r ^J 0) C6 C6 ll�_ I 00 Lo N O � M W w 1- O M W � Lo �p M Lo U O M co Lu Z O w 0 co T_ M J -ll)H M ._ QQ o M N 0. w,Q ur Lo , C7 V zi CD U) ' CD ti DATE 09 -19 -11 SCALE AS NOTED DRAWING M.A.S. JOB SHEET OF 3 SHEETS 3 >.a'r f ':,i w �• M N J; LY.ti y t' 'A °x1 , a,I._'�.