Loading...
12-586R-0033350 MCM THIN (CU) 1 -1/2'C FO 3350 MCM THWN (CU) 2 -V2'C SEPARETELY NON - DERIVED 21--400A AUTOMATIC TRANSFER SWITCH (22AXPO AIC) 3350 MCM THIN (Cu) 2 -1/2'C O 8 x 8' 33/0 T" JI GRD. (CU) - 2'C 200 2200 2 150 FUTURE GENERATOR (BY OTHERS IN SEPARTATE PERM ) (22000 AJ.CJ TYPICAL (CU) - 3/4'C PNL B 30/0 THIN 116 GRD. (CU) - 2'C 33/0,1% OF0 THIN (CU) 2'C I -5/8' COFPERCLAD Cs�D ROD 'LAD (METAL) 10 FT. LONCs 5LDCs. STEEL FOUNDATION R15ER DIAGRAM NOTEt PROVIDE 08 BARE COPPER BOND WIRE FROM LIGHT TO POOL STEEL.WHERE A CONCRETE DECK IS NOT PROVIDED, PROVIDED A " 8 BARE COPPER BOND WIRE FROM THE POOL STEEL TO THE EQUIPMENT TO PANEL. WHERE A CONCRETE SLAB IS PROVIDED, THE BOND WIRE SHALL BE CONNECTED FROM THE POOL STEEL TO REINFORCING MESH CONTINUOUS TO THE 05 REINFORC- ING BAR IN THE PERIMETER SLAB FOOTING. A BOND WIRE SHALL THEN BE CONNECTED FROM THE PERIMETER STEEL TO THE EQUIPMENT TO THE ELECTRICAL PANEL. ELECTRICAL NOTES: I. ALLPOOL ELECTRICAL WORK SHALL BE ACCOMPLISHED IN COMPLIANCE WITH 2010 FLORIDA RESIDENCE BUILDING CODE. 2ALL ELECTRICAL GROUNDING AND BONDING MUST BE CONFORM WITH THE FLORIDA BUILDING CODE. 3. NO OVERHEAD WIRING SHALL BE LOCATED WITHIN 10' .0' OF POOL'S WATER EDGE. 4. SHOULD THE ELECTRICAL RISER DIAGRAM NOT ACCURATELY DEPICT REQUIRED WORK, A REVISED DRAWING SHALL BE SUB- MITTED AND APPROVED SHOWING EXPECTED AS BUILT CONFIGURATION WITH ADDITIONAL SERVICE AND LOAD CALCULATIONS, IF NECESSARY. 5ALL ELECTRICAL EQUIPMENT NOT SUITABLE FOR EXPOSURE TO THE ELEMENTS SHALL BE ENCLOSED IN A WEATHERPROOF CONTAINER ALL PUMPS, HEATERS AND RTELATEDPOOL EQUIPMENT SHOWN ON THESE PLANS ARE SATISFACTORY FOR EXPOSURE TO THE ELEMENTS. 111 w L1 WIRE " 8 COOPER Z TO POOL EQUIPMENT I8� ' -?'4' M 2 " 12 THHN IP 20 AMP. I's 12 THHN CU. GROUND. PNL C=FI RECEPTACLE 6' MIN. 20' MAX FROM WATER LINE 3 " 8 HEAT PUMP I-I F- 2P40A 40ASW •33 THLLN ,lab ORO. 2 " 12 THHN TRANSFORMS (CU) - II/1'C 2P 20 AMP. l PUMP ) 2012 THHN 15 W IF 20 AMP.IBLOWER 120 V.) TRANSFORMER 2" 12 THHN iP 15 AMP.ILIGTH) SW I " 12 THHN CU. GROUND. 1P -20 A. SW (LGHT) JB PROVIDE GFGI IF 20 AMP. SUK PUMP) JB 2P 20 AMP. BRAKER FOR POOL PUMP. 15 HP BLOWER 120 VOLT 2 HP PUMP VARIABLE SPEED (TWO SPEED PUMP) 300 W 12 V 15 W 12 V 230 V. POOL LIGHT SPA LIGHT 120/240V PANEL 'If=" 100A M.L.O. 1 PH, 3W (W, PROOF) SURFACE MTD CKT. NO. DESCRIPTION C/B TRIP LOAD WIRE CONDUIT REMARKS 1,3 C.U. -1 2P -60 6000 2 #6 -3/4 "C M 5,7 POOL PUMP 2P -25 2000 2 #10 -1/2 "C ON TIMER 2,4 RECEPTACLES 1P -20 900 #12 -1/2 "C 0 6 LANDSCAPE 1 P -20 1800 IN It M O ON TIMER 8,10 POOL LIGHT 1P-20 600 2'-0* C CLEAR PVC -PW, NON - THREADED, NSF APPROVED SUPPORTED CONTNUOSLY GFI 9 POOL HEATER 2P -60 6000 2 #6 -3/4 "C ON GROUND OR ON MAXIMUM 4' -0' CENTERS WITH CLEVIS HANGERS. 11,12 SPACE �a PROJECT NUMBER 13 -18 SPACE 0 "A).• l PRESSURE PIPING 1 1/2' DIAMETER UNLESS OTHERWISE NOTED. 3. POOL WATER DISPOSAL SHALL BE IN ACCORDANCE WITH LOCAL _r 0 TOTAL 17,300 (72.0 A) NOTE:PROVIDE LINT S SING BONDED IN FOUR 360') AROUND POOL < dJ POOL STEEL i NOTE: BOND WIRE TO BE SECU TO STEEL < GRID WITH APPROVED CLAMP. TO BE ENCASED IN DECK SLAB OR CONCRETE BOX PROVIDING MIN. 3' OF COVER AROUND CLAMP I' NON METALLIC CONDUI TO JUNCTION BOX POOL BOND 4 UNDERWATER LIGHT DETAIL NO SCALE STRUCTURAL NOTES: 1. ALL POOL CONCRETE SHALL DEVELOP A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 2. ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF 60 .000 PSI. 3. ALL DECK CONCRETE (WHEN INSTALLED UNDER THESE PLANS) SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI. 4. THE DESIGN OF THIS PROJECT HAS INCORPORATED A RATIONAL DESIGN APPROACH BASED ON ACCEPTED ENGINEERING PRINCIPALS. 5. ALL REINFORCING STEEL SPLICES SHALL BE 18' IN LENGTH UNLESS OTHERWISE INDICATED ON THESE PLANS. 6. ALL REINFORCING STEEL BENDS SHALL BE BY HAND WITHOUT THE APPLICATION OF NEAT TO THE STEEL. 501 L STATEMENT A VISUAL INSPECTION AT JOB SITE SHOWED A SOIL COMPOSED OF SAND AND ROCK. A BEARING CAPACITY OF 2000 P.S.F. HAS BEEN ASSUMED. FURTHER MORE, UPON BREAKINS OF GROUND, A LETTER SHALL BE 5UBMITED TO THE SUILDINS OFFICIAL VERIFY'INS AND ATTESTINS THAT THE SITE CONDITIONS ARE SIMILAR TO TH05E UPON THE DE51SN BASED. POOL WATER LINE 6• i � 0 L PROVIDE 03 119 10' HOR < VERT O`O`H � _ , M PROVIDE 03 a 10' EACH WAY (MIN. SPLICE 18' ) T`f= POOL SECTION NO WALE POOL D LOAD TABULATION DEMAND A/c FNL 'A' = 52.4 525 i�rlL 'B' = 153 5J3� TOTAL = 61.1 11.1 FIRST 10 KW 9 100% = 100 51.1 KW g 409. =23D6 A/G POOL C PING X ON 0 PROVIDE 03 g 10' HOR. : VERT ANTI VORTEX MANINDRAN , HYDROSTATIC RELIEF VALVE SET IN WASHED ROCK BED WATER LINE i L Q) U PROVIDE 03 a 10' / m HOR. t VERT v PROVIDE 03 A 10' EACH WAY WALL SECTION NO SCALE POOL POOL PROVIDE HOR 3/A BULL? CARTRIDGE QPOOL FILTER WITH 200 1 SQ.FT. OF SURFACE ARE NOTE: BALL VALVES MAY BE SUBSTITUTED FOR MULTIPORT VALVES TOTAL = 44.18 KW 086A) POOL COPING POOL DECK -\ I 1Si HEAT PUMP O01- Jti�g \ \�, gP P . ?00\.* gQ �\A�` 1' POOL RECIRCULATION PUMP VARIABLE SPEED 2.0 HP, 100 GPM AT 60' TDH SELF PRIMING ISOMETRIC 1 15 HP BLOWER 120 volt HEAT PUMP MOUNTING DETAIL AViERT1<1 clear PROVIDE HOP. I = WATER LINE 013 'g 10' EACH WAY W/ 18' MIN. SPLICE SWIMOUT SECTION NO SCALE 03 g 10' EACH WAY TYfm STEP SECTION NO SCALE ER LINE 4' CONC. SLAB / 6x6 010 /10WWM 2500 PSI CON .MIN. FIBEm' -saH CO MAY BE USED IN LIEU OF 6x6 010/1011 AS ALLOWED BY CODE � II �IIII L� II I�i�lll���ll�lll���lll���lll���lll���lll���ll�lll���lll���l _ rr WELL COMPACTED FILL I I- III -III I I -I I I i� RISERS AT 11= III= III= III = 111'' " EACH I THICKENED EDGE MIN. CLEA EACH WAY 3' Will 05 CONTINUOUS CONCRETE SLAB DETAIL scale: N.T.S TEE SAME SIZE AS PUMP SUCTION 450 F--- - --- M - •, 850 TURNOVER (HOURS) 3.9 0.14 all 90 �'� .�aa•C ��` M 325 kn 0 M PLUMBING NOTES: U 00 a WEIR 0 MAINTAIN �p vn 0 Lw M N kn Z O w En N t � 1' -0' CLEAR IN It M O W O REAR 2'-0* C CLEAR PVC -PW, NON - THREADED, NSF APPROVED SUPPORTED CONTNUOSLY 4. HEAT PUMP MOUNTING DETAIL AViERT1<1 clear PROVIDE HOP. I = WATER LINE 013 'g 10' EACH WAY W/ 18' MIN. SPLICE SWIMOUT SECTION NO SCALE 03 g 10' EACH WAY TYfm STEP SECTION NO SCALE ER LINE 4' CONC. SLAB / 6x6 010 /10WWM 2500 PSI CON .MIN. FIBEm' -saH CO MAY BE USED IN LIEU OF 6x6 010/1011 AS ALLOWED BY CODE � II �IIII L� II I�i�lll���ll�lll���lll���lll���lll���lll���ll�lll���lll���l _ rr WELL COMPACTED FILL I I- III -III I I -I I I i� RISERS AT 11= III= III= III = 111'' " EACH I THICKENED EDGE MIN. CLEA EACH WAY 3' Will 05 CONTINUOUS CONCRETE SLAB DETAIL scale: N.T.S TEE SAME SIZE AS PUMP SUCTION 450 Vf zi •,� •, 850 TURNOVER (HOURS) 3.9 0.14 all 90 �'� .�aa•C ��` DECK AREA ( SQFT) 325 kn 0 ADJUSTABLE LID PLUMBING NOTES: U 00 a WEIR 0 MAINTAIN �p vn BASKET ���p q� (Ml SQ.IN.) Lw M N kn Z O w CERAMIC TILE 1' -0' CLEAR IN I. ALL POOL EQUIPMENT PIPING SHALL BE SCHEDULE 40, W O REAR 2'-0* C CLEAR PVC -PW, NON - THREADED, NSF APPROVED SUPPORTED CONTNUOSLY 4. SKIMMER DETAIL SIDE ON GROUND OR ON MAXIMUM 4' -0' CENTERS WITH CLEVIS HANGERS. a �a PROJECT NUMBER 2. ALL SUCTION PIPING SHALL BE 2' DIAMETER AND ALL 0 "A).• l PRESSURE PIPING 1 1/2' DIAMETER UNLESS OTHERWISE NOTED. 3. POOL WATER DISPOSAL SHALL BE IN ACCORDANCE WITH LOCAL _r 0 a BUILDING DEPARTMENT REQUIREMENTS. I MAINTAIN 4. ANTI VORTEX MAINDRAINS SHALL HAVE ITS PLATE SECURELY FASTENED w W 3' -0' CLEAR WITH TAMPERPROOF SCREWS. N U FRONt 5. POOL VACUUM SHALL HAVE SPRING LOADED CAP IN ACCORDANCE WITH THE FLORIDA BUILDING CODE. O 6. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE- PLUMBING SECTION 309 AS IT PERTAINS W MAINTAIN r TO BOUYANCY. 1. THE 2' -0' CLEAR WATER VELOCITY THOUGH ALL SUCTION PIPING SHALL BE LESS SIDE THAN 8 FEET PER SECOND. r S. THE WATER VELOCITY THROUGHT ALL PRESSURE PIPING SHALL BE LESS THAN 10 FEET PER SECOND. O S. ALL PIPING SHALL BE SUITABLE FOR EXPOSURE TO ULTRA VIOLET Z RADIATION AND NORMAL OPERATING TEMPERATURES. 1' h'1 00 v 00 PROVIDE FACTORY ANCHORS CLAMPS CONCRETE BASE WITH IN X 3' STAINLESS STEEL TAPCON 4' THICKNESS MINIMUM 3' -0' MINIMUN SCREWS AT EACH ANCHORS CLAMP TO CONCRETE SLAB UNIT MUST BE INSTALLED TO WITHSTAND NOTE: (C: ANTI X 116 MPH HURRICANE FORCE WINDS UNIT THIS HEAT PUMP WAS PROVIDED WITH ANCHOR CLAM S DESIGNED MANDRAIN COVERS TO HOLD THE UNIT TO THE EQUIPMENT PAD IN HIGH WI D COND TIONS. HEAT PUMP MOUNTING DETAIL AViERT1<1 clear PROVIDE HOP. I = WATER LINE 013 'g 10' EACH WAY W/ 18' MIN. SPLICE SWIMOUT SECTION NO SCALE 03 g 10' EACH WAY TYfm STEP SECTION NO SCALE ER LINE 4' CONC. SLAB / 6x6 010 /10WWM 2500 PSI CON .MIN. FIBEm' -saH CO MAY BE USED IN LIEU OF 6x6 010/1011 AS ALLOWED BY CODE � II �IIII L� II I�i�lll���ll�lll���lll���lll���lll���lll���ll�lll���lll���l _ rr WELL COMPACTED FILL I I- III -III I I -I I I i� RISERS AT 11= III= III= III = 111'' " EACH I THICKENED EDGE MIN. CLEA EACH WAY 3' Will 05 CONTINUOUS CONCRETE SLAB DETAIL scale: N.T.S TEE SAME SIZE AS PUMP SUCTION O \°J \ 1 1/2' HYDROSTATIC RELIEF TUBS. ONLY ONE REQUIRED 450 Vf zi •,� •, 850 TURNOVER (HOURS) 3.9 0.14 all 90 O \°J \ 1 1/2' HYDROSTATIC RELIEF TUBS. ONLY ONE REQUIRED 450 r. (. lie 13100 850 TURNOVER (HOURS) 3.9 0.14 MANDRAIN DETAIL NO SCALE 90 �'� .�aa•C ��` DECK AREA ( SQFT) 325 kn 0 ADJUSTABLE LID U 00 a WEIR M WATER LEVEL CTRETE �p vn BASKET ���p q� (Ml SQ.IN.) Lw M N kn Z O w CERAMIC TILE U POOL WALL S TION LINE W O �3 yr SOUTH PA ay E?fJii_%iNG DEP SKIMMER DETAIL JLfcruRaL SECT( Nn SCALE �a PROJECT NUMBER )VED By "A).• l POOL DAT,4 _r SURFACE AREA (SQFT-) 450 49 VOLUME (GALLONS) 13100 850 TURNOVER (HOURS) 3.9 0.14 PERIMETER (FEET) 90 28 DECK AREA ( SQFT) 325 HYDROSTATIC UPLIFT ELEV. TOP OF POOL WALL 9b0' DEPTH OF POOL 4B3' ELEV. TOP OF MAINDRAIN 411' FLOOD CRITERIA 8�0 ELEV. TOP OF MAINDRAIN 4.11' POOL IN FLOOD CRITERIA 323' LESS 2' .0' HYDROST VALVE 123' SLAB THICKNESS REQUIRED 6" NOTE: IF THE POOL IN FLOOD CRITERIA IS LESS THAN 6.1 FEET THEN THE FLOOR SLAB SHALL TAPER FROM 6' AT THE SHALLOW END TO THAT INDICATED ABOVE AS SLAB THICKNESS REQUIRED. APPROVED INDICATED DATE SCALE SHEET NO: 3 OF : 3 r y• , „w •. a .- kill N a